CA-558-2 Interlock Cable

8010 High Power Device Test Fixture:
The 8010 High Power Device Test Fixture provides safe and easy connections for testing packaged high-power devices at up to 3000 V or 100 A. The 8010 provides connections for a high voltage SourceMeter SMU instrument (2657A), one or two high current SourceMeter SMU instruments (2651A), and three low power SourceMeter SMU instruments (other Series 2600B or 4200A-SCS source measure unit (SMU) instruments). This allows devices with two terminals (diodes) or three terminals (transistors) or even four or five terminals to be characterized safely and accurately. The 8010 has full interlock capability for up to six SourceMeter SMU instruments. The 8010 has integrated protection circuits that protect the low voltage SourceMeter SMU instruments from high voltages the 2657A can output should a device fault occur. The 8010 includes both a high current (100 A) and a high voltage (3000 V) test socket. Various replacement test socket modules are available, including TO-247, TO-220, axial lead, and a blank socket module that allows the building of a custom socket. In addition to standard banana jumpers, the 8010 has the rear-panel scope and thermal probe ports to simplify system integration.

Accessories Supplied

3 ea. CA-558-2: Three-Pin Interlock Connector Cables (2 m)
12 ea CA-560-x: Banana to Banana Jumper Cables (203 mm)
2 ea. CA-562-x: Safety Banana to Banana Jumper Cables (254 mm)
6 ea. CA-563: BNC to Banana cables (241 mm)
2 ea. CA-568-120: Earth Safety Ground Cables (305 cm)
1 ea. 8010-317: Socket Insulating Plug Card
1 ea. 8010-CTB: Customizable Test Board
2 ea. 8010-DTB: Device Test Board for TO-247 Devices (3 kV, 100 A)
For use with: 2651A, 2657A, 4200A-SCS, 26xxB, 2600-PCT-x, 4200-PCT-x

KEITHLEY CA-558-2 Interlock Cable - Fig 1

KEITHLEY CA-558-2 Interlock Cable - Fig 2

8009 Resistivity Chamber: The 8009 is a guarded test fixture for measuring volume and surface resistivities. It assures good electrostatic shielding and high insulation resistance up to 1100 V. The 8009 is designed for safe operation with 6517A or 6517B. Opening the lid of the 8009 au to the mat cal ly turns off the 6517A or 6517B voltage source. The 8009 ac com mo dates sheet samples from 64 mm to 102 mm (2½ to 4 in) in diameter and up to 3.2 mm (1⁄8 in) thick. It maintains good sample contact with uniform pressure (from 6 to 10 lbs depending on thickness) on smooth parallel samples.
With the front panel switch on the 8009, toggle between volume and surface re sis activity, with the 6517A or 6517B configured to calculate and display the appropriate result automatically. The 8009 permits direct measurement of volume resistivity up to 1018 Ω-cm (on samples 0.1 cm thick) and surface resistivity up to 10 17 Ω/square, in accordance with ASTM procedures.

Accessories Supplied
6517-ILC-3: Interlock Cable for 6517A
6517B-ILC-3: Interlock Cable for 6517B
7078-TRX-3: Triax Cable
8007-GND-3: Safety Ground Wire
8607: Source Cable Set

Environmental Limits: Operating: –30° to +85°C, 65% R.H. up to 35°C, derate 3% R.H./°C above 35°C. Stor age: –25° to +85°C.
Dimensions: 108 mm high × 165 mm wide × 140 mm deep (41⁄4 in × 6½ in × 5½ in).
Weight: 1.45 kg (3.19 lbs).
For use with: 6487, 6517A, 6517B SourceMeter

KEITHLEY CA-558-2 Interlock Cable - Fig 3

8101-PIV: DC and pulse I-V demo fixture that is a metal case with four female Triax connectors, two SMA connectors, and a latch. Inside the test, fixtures are two 4-pin device holders (transistor sockets) and two plungers for parts with two leads.
For use with: 4200A-SCS, Series 2600B, 6482, and 40 V-rated triaxial or SMA instrument

Contact Information:
Australia 1 800 709 465
Austria 00800 2255 4835
Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777
Belgium
00800 2255 4835
Brazil +55 (11) 3530-8901
Canada 1 800 833 9200
Central East Europe / Baltics +41 52 675 3777
Central Europe / Greece +41 52 675 3777
Denmark +45 80 88 1401
Finland +41 52 675 3777
France 00800 2255 4835
Germany
00800 2255 4835
Hong Kong 400 820 5835
India 000 800 650 1835
Indonesia 007 803 601 5249
Italy 00800 2255 4835
Japan 81 (3) 6714 3086
Luxembourg +41 52 675 3777
Malaysia 1 800 22 55835
Mexico, Central/South America and Caribbean 52 (55) 88 69 35 25
Middle East, Asia, and North Africa +41 52 675 3777
The Netherlands 00800 2255 4835
New Zealand 0800 800 238
Norway 800 16098
People’s Republic of China 400 820 5835
Philippines 1 800 1601 0077
Poland +41 52 675 3777
Portugal 80 08 12370
Republic of Korea +82 2 565 1455
Russia / CIS +7 (495) 6647564
Singapore 800 6011 473
South Africa +41 52 675 3777
Spain
00800 2255 4835
Sweden 00800 2255 4835
Switzerland
00800 2255 4835
Taiwan 886 (2) 2656 6688
Thailand 1 800 011 931
United Kingdom / Ireland* 00800 2255 4835
USA 1 800 833 9200
Vietnam 12060128

  • European toll-free number. If not
    accessible, call: +41 52 675 3777

Find more valuable resources at TEK.COM
Copyright © Tektronix. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges are reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks or registered trademarks of their respective companies. 100622 SBG 1KW-4674-1

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

KEITHLEY User Manuals

Related Manuals