KEITHLEY 2601B Pulse System Source Meter User Guide
- June 1, 2024
- KEITHLEY
Table of Contents
- KEITHLEY 2601B Pulse System Source Meter
- Product Information
- Product Usage Instructions
- GENERAL INFORMATION
- SUPPORTED OPERATING SYSTEMS
- INSTALL ACS BASIC
- UPDATE PREVIOUS VERSIONS OF ACS BASIC FILES
- SUPPORTED MODELS AND TEST CONFIGURATIONS
- SUPPORTED COMMUNICATION INTERFACES
- SOFTWARE LICENSE
- ACS BASIC VERSION 3.3
- RESOLVED ISSUES
- SOFTWARE COMPATIBILITY
- USAGE NOTES
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
KEITHLEY 2601B Pulse System Source Meter
Product Information
Specifications
- Product Name: ACS Basic Edition
- Version: 3.3
- Release Date: November 2023
- Manufacturer: Keithley Instruments
- Operating System Compatibility: Refer to supported operating systems section
Product Usage Instructions
Install ACS Basic
- Log in to your computer as an Administrator.
- Open the ACS Basic executable file.
- Follow the software installation instructions.
- Select Yes if you have an older version of ACS Basic installed.
- Follow the instructions to specify how you want to install the software on your system.
- For backup or restore from a previous version, see Update previous versions of ACS Basic files.
Install ACS Basic on a 4200A-SCS Parameter Analyzer
If installing on a 4200A-SCS Parameter Analyzer, follow the specific dialog
box instructions provided.
Update Previous Versions of ACS Basic Files
- Go to C:ACS_BASICUpgradeTool.
- Double-click UpgradeTool.exe.
- Choose the items in the folder you want to update.
- Select Copy to update the files.
Manually Copy Projects and Libraries
- Copy and paste projects and libraries from the previous version by following the provided steps.
Frequently Asked Questions (FAQ)
-
Q: Can ACS Basic files before version 3.0 be converted using UpgradeTool.exe?
A: No, ACS Basic files before version 3.0 cannot be converted using UpgradeTool.exe. -
Q: What should I do if I have ACS Basic version 2.1.5 or later?
A: If you have ACS Basic version 2.1.5 or later, you must manually copy the projects and libraries following the provided steps.
ACS Basic Edition
Version 3.3 Release Notes
Keithley Instruments
28775 Aurora Road Cleveland, Ohio 44139
1-800-833-9200
tek.com/keithley
GENERAL INFORMATION
- This document describes the features added to the Keithley Instruments Automated Characterization Suite (ACS) Basic Edition software (version 3.3).
- The Keithley Instruments ACS Basic Edition software supports component characterization testing of packaged parts and wafer-level testing using a manual probe station. ACS Basic Edition software can be installed on any computer, including Keithley Instruments Model 4200A-SCS Parameter Analyzer, or Model 4200 Semiconductor Characterization System (4200-SCS).
SUPPORTED OPERATING SYSTEMS
ACS Basic Edition software is supported on the following operating systems:
- Microsoft® Windows® 11, 64-bit
- Microsoft Windows 10, 64-bit
- Microsoft Windows 10, 32-bit
- Microsoft Windows 7, 64-bit (with Service Pack 1)
- Microsoft Windows 7, 32-bit (with Service Pack 1)
ACS BASIC EDITION REVISION HISTORY
Version | Release date |
---|---|
3.3 | November 2023 |
3.2.1 | March 2023 |
3.2 | November 2022 |
3.1 | March 2022 |
3.0 | August 2021 |
2.1.5 | November 2017 |
2.1 | November 2015 |
2.0 | September 2012 |
1.3 | July 2011 |
1.2 | September 2010 |
INSTALL ACS BASIC
To install ACS software on a personal computer:
- Log in to your computer as an Administrator.
- Open the ACS Basic executable file.
- Follow the software installation instructions.
- Select Yes if you have an older version of ACS Basic installed, as shown in the following figure.
- Follow the instructions to specify how you want to install the software on your system.
- If you have projects you need to backup or restore from a previous version of ACS Basic, see Update previous versions of ACS Basic files.
Note
If you are installing ACS on a Model 4200A-SCS Parameter Analyzer, see the
following information.
Install ACS Basic on a 4200A-SCS Parameter Analyzer
If you are installing ACS Basic on a 4200A-SCS Parameter Analyzer, the
following dialog box displays indicating that the applications identified are
needed for installation. Make sure you select Do not close applications and
Next to install (see the following figure). Note
If you are installing Clarius+ and ACS Basic on the same system, Clarius+ must
be installed first.
UPDATE PREVIOUS VERSIONS OF ACS BASIC FILES
Note
Once ACS Basic is installed, you can use UpgradeTool.exe to convert your ACS
Basic version 3.0 files or later to the present version, which includes
projects, libraries, and settings from previous versions. ACS Basic files
before version 3.0 cannot be converted using this method.
To update previous software files:
- Go to C:\ACS_BASIC\UpgradeTool\.
- Double-click UpgradeTool.exe.
- Choose the items in the folder you want to update (see the following figure).
- Select Copy.
When the updated version of ACS Basic is installed, the previous version is renamed. You can copy the projects and libraries from the previous version using the following steps.
Note
If you have ACS Basic version 2.1.5 or later, you must manually copy the
projects and libraries by following the steps below.
To copy and paste folders:
- Find the C:\ACS_BASIC_DDMMYYYY_HHMMSS\Projects\ folder.
- Copy and paste to the present C:\ACS_BASIC\Projects\ folder.
- Find the C:\ACS_BASIC_DDMMYYYY_HHMMSS\library\pyLibrary\PTMLib\ folder.
- Copy and paste to the present C:\ACS_BASIC\library\pyLibrary\PTMLib\ folder.
- Find the C:\ACS_BASIC_DDMMYYYY_HHMMSS\library\26library\ folder.
- Copy and paste to the present C:\ACS_BASIC\library\26library\ folder.
Note
ACS Basic 3.3 is based on the Python 3.7 programming language. If you
customized your projects in a previous version of ACS Basic you may need to
change the projects created in the older version of ACS Basic, which includes
the Python language test module (PTM) script libraries. You can go to this
site to review the Python changes for more detail:
https://docs.python.org/3/whatsnew/3.7.html#porting-to-python-37
Install ACS Basic after installing NI-488.2 drivers
If you are installing ACS Basic on a system that contains NI-488.2 drivers,
the following dialog box displays indicating that the applications identified
are needed for installation. Make sure you select Do not close applications
and Next to install (see the following figure).
SUPPORTED MODELS AND TEST CONFIGURATIONS
- ACS Basic Edition software is used to characterize semiconductor devices with a variety of Keithley Instruments products in a variety of different configurations. The ACS Basic Reference Manual (part number ACSBASIC-901-01) contains detailed information about the supported hardware and test configurations.
- The following table summarizes the instruments supported in the ACS Basic test libraries.
Instrument type | Supported models |
---|---|
SMU Instruments | 2600B Series: 2601B, 2602B, 2604B, 2611B, 2612B, 2614B, |
2634B, 2635B, 2636B
2600A Series: 2601A, 2602A ,2611A, 2612A, 2635A, 2636A
2400 Graphical Series SMU (KI24XX): 2450, 2460, 2460-NFP, 2460-NFP-RACK,
2460-RACK, 2461, 2461-SYS, 2470
2400 Standard Series SMU: 2401, 2410, 2420, 2430, 2440
2650 Series for High Power: 2651A, 2657A
Parameter Analyzers| 4200A and supported cards/modules: 4210-CVU, 4215-CVU,
4225-PMU/4225-RPM, 4225-RPM-LR, 4200-SMU, 4201-SMU, 4210-SMU, 4211-SMU,
4200-PA, 4200A-CVIV
DMMs| DMM6500, DMM7510, 2010 Series
Ultra-sensitive Current Sources and Nanovoltmeter| 6220,6221, 2182A
Switching and data acquisition systems| DAQ6510, 707A/B, 708A/B, 3700A
Pulse Generators| 3400 Series
Note
- The graphical interactive test module (ITM) supports 24xx Graphical Series SMU instruments and 26xx instruments at the same time. The 24xx instrument should be connected as the primary instrument, and the 26xx connected as the subordinate.
- You can control any Test Script Processor (TSPTM) instrument using a script test module (STM) script.
- You can control any instrument using a Python language test module (PTM) script, including instrumentation from other vendors.
- Existing ACS Basic STM and PTM libraries support specific instruments based on the library definition.
SUPPORTED COMMUNICATION INTERFACES
- GPIB
- LAN (Auto Scan and LAN)
- USB
- RS-232
Note
If you are using an RS-232 connection, the instrument is not automatically
added to the hardware configuration. Add instruments connected with RS-232
manually and change the hardware configuration file that is in the following
directory on your computer to the following:
C:\ACS_BASIC\HardwareManagementTool\HWCFG_pref.ini. In this file you can
change the baud rate, parity, byte, and stopBit settings. Review the following
figure for details.
SOFTWARE LICENSE
ACS Basic allows you to create tests, manipulate settings, and view previous
data without a license. However, you must have a license for ACS Basic in to
control and retrieve data from a physical instrument. You can launch a one-
time, 60-day trial for ACS Basic after the initial installation. Once the
license expires, you need to purchase a full license to use the software.
LICENSE MANAGEMENT
The ACS Basic software license is managed using the Tektronix Asset Management
System (TekAMS).
To generate a license file:
- You must submit your Host ID to TekAMS. For more information on TekAMS, see tek.com/products/product-license .
- To find the host ID, open the License Manager dialog box from the ACS Basic Help menu. Select License > Host ID, then Click to copy to copy the Host ID.
- Select Install.
ACS BASIC VERSION 3.3
ENHANCEMENTS
Hardware configuration
Issue number:
Enhancement:
| ACS-784, CAS-209266-Y5K4F1
Support for the Keysight E4980A added.
Issue number:
Enhancement:
| ACS-716
Support for TSP-Link connections to the DMM6500 and DMM7510.
Issue number: Enhancement:| ACS-677
Add Hardware Scan Tool support scanning for:
- 6221 through GPIB and ethernet
- 6220 through GPIB
- 2182 and 2182A through RS232 or Trigger Link cable to the 6220 or 6221
ACS Basic software and libraries
Issue number:
Enhancement:
| ACS-766, CAS-199477-J6M6T8
Switching speed when switching between PTMs and ITMs has been optimized.
Issue number:
Enhancement:
| ACS-762
Support added for saving data to the Excel ® format, .xlsx.
Issue number: Enhancement:| ACS-724
Shared-Stress App: Added an example library and project to show how to use the
built-in shared stress functions.
Issue number: Enhancement:| ACS-718
DMM7510 and DMM6500 support: Added TSP library DMM_SMU_lib.tsp including the
functions FIMV_Sweep and FIMV_Sample.
Issue number:
Enhancement:
| ACS-717
2601B and DMM7510 support: Added LIV_Lib.tsp library.
Issue number:
Enhancement:
| ACS-713, ACS-712
Added test library VTH_SiC under device PowerMosfet for ACS Basic.
Issue number:| ACS-690, ACS-689
Enhancement:| Added the standard PTM KI622x_2182_Lib.py library to support
delta and differential measurements using the Keithley Instruments Model 6220
or 6221 used with a Model 2182A.
Issue number:| ACS-681, ACS-680, ACS-679
Enhancement:| Added Shared-Stress App: Added python library
Share_Stress_App.py and shared_Stress_Demo.py.
Issue number:| ACS-676
Enhancement:| Add a PTM demo script to run a UTM library remotely on the
4200A-SCS through KXCI.
Issue number:| ACS-664, CAS-143278-Z7L7T3
Enhancement:| Added support for generalized Shared-Stress testing.
Issue number:| ACS-653, CAS-124875-V3W1G7
Enhancement:| UpgradeTool.exe was added to help convert your ACS 6.0 files or
later to the present version, including projects, libraries, and settings from
previous versions.
ACS Basic manual updates
Issue number:
Enhancement:
| ACS-757, ACS-744, ACS-743, ACS-733, ACS-711
Automated Characterization Suite (ACS) Basic Software Reference Manual
update.
Issue number:
Enhancement:
| ACS-790, ACS-785, ACS-719, ACS-715, ACS-714, ACS-711
Automated Characterization Suite (ACS) Basic Edition Libraries Reference
Manual update.
Issue number:
Enhancement:
| ACS-711
ACS Basic Software Quick Start Guide update.
RESOLVED ISSUES
Issue number:
Enhancement: Resolution:
| ACS-763, CAS-198461-L5X8W7
---|---
When ACS Formulator formula VTCI returns #REF, the data cannot be saved to an
.xls file. This issue has been corrected.
Issue number: Enhancement: Resolution:| ACS-758
ITM 2461 Pulse mode incorrectly reached compliance at current lower than the
limiti setting.
This issue has been corrected.
Issue number:
Enhancement: Resolution:
| ACS-755
---|---
Formulator from the last device-level running file is copied to all ITMs. This
issue has been corrected.
Issue number:
Enhancement: Resolution:
| ACS-753, CAS-191970-C6C2F3
ACS Basic graph problem: Fixed Scale applied incorrectly to Y2. This issue has
been corrected.
Issue number:
Enhancement: Resolution:
| ACS-752, CAS-191977-V4N4T0
ACS Basic graph problem with Log Scale. This issue has been corrected.
Issue number:
Enhancement: Resolution:
| ACS-751, CAS-191987-Q2T8Q5
ACS Basic graph scale format error (scientific linear). This issue has been
corrected.
Issue number:
Enhancement: Resolution:
| ACS-750, CAS-191988-X7C2L0
ACS Basic graph scale format error (scientific LOG). This issue has been
corrected.
Issue number:
Enhancement: Resolution:
| ACS-740
The 2450, DMM6500, and DAQ6510 report errors when starting ACS Basic. This
issue has been corrected.
Issue number:
Enhancement: Resolution:
| ACS-737, CAS-183556-J8P1L6
Cannot enable High C mode in an ITM when connected to a Model 2657A. This
issue has been corrected.
Issue number:
Enhancement: Resolution:
| ACS-732
Cannot enable High C mode in an ITM when connected to a Model 2657A. This
issue has been corrected.
Issue number:
Enhancement: Resolution:
| ACS-706
sintgv() is missing in TSPLPT. This issue has been corrected.
Issue number: Enhancement:
Resolution:
| ACS-705
The Combine SMU button is disabled in configure demo mode in the Hardware
Management Tool.
This issue has been corrected.
Issue number: Enhancement:
Resolution:| ACS-704, CAS-168192-R6R9C0
When measuring a CF sweep (from 10 kHz to 100 kHz) on a sample that has a
capacitance value of about 100 pF, inaccurate data was shown at 10 kHz
frequency.
This issue has been corrected.
Issue number: Enhancement:
Resolution:| ACS-699
When a customer enters a pattern, subsite, or device name that starts with a
number, the project is damaged.
This issue has been corrected by displaying a message if the user tries to use
a name that starts with a number.
Issue number:
Enhancement: Resolution:| ACS-695
TSPLPT delcon command is not working correctly. This issue has been corrected.
Issue number: Enhancement:
Resolution:| ACS-688
ACS Basic cannot scan a Model 707B Switching System that contains a 7072B
cards in the Hardware Management Tool.
This issue has been corrected.
Issue number:
Enhancement: Resolution:
| ACS-687, CAS-157136-K7R9R0
---|---
High Open Offset Capacitance issue on PCT HVCV Test. This issue has been
corrected.
Issue number:
Enhancement: Resolution:
| ACS-686
Added ACSLPT sweepX, bsweepX functions for 4200A SMU. This issue has been
corrected.
Issue number:
Enhancement: Resolution:
| ACS-685
Y1/Y2 min/max scale in the plot setting is automatically changed when running
a test. This issue has been corrected.
SOFTWARE COMPATIBILITY
Issue number: Resolution: | N/A |
---|
When you start ACS Basic on a 4200A-SCS that has Clarius software version 1.4 or later (with the Windows 10 operating system), a warning message may appear indicating that KXCI did not start successfully. Select Cancel to dismiss the warning.
To manually configure the compatibility settings:
- Right-click the ACS Basic icon and select Properties.
- Open the Compatibility tab.
- Select Run this program as an administrator and select OK to save.
USAGE NOTES
Issue number: Resolution: | N/A |
---|
If you install a KUSB-488B GPIB driver, the following message displays. You must select the Keithley Command Compatible option. Select Next to continue the installation.
Issue number: Resolution: | ACS-691, CAS-162126-B3Y7Y6 |
---|
Microsoft ® Windows® mapped network drive error.
When installing ACS Basic on a personal computer, Microsoft policy settings
can limit ACS Basic from accessing mapped network drives in its file windows.
Modifying the registry fixes this issue. To modify the registry:
- Run regedit.
- Navigate to HKEY_LOCAL_MACHINE/SOFTWARE/Microsoft/Windows/CurrentVersion/Policies/ System.
- If one does not exist, create a new DWORD (32-bit) entry named EnableLinkedConnections.
- Set the value to 1.
- Restart the computer.
References
- Keithley Instruments & Products | Tektronix
- Product License | Tektronix
- What’s New In Python 3.7 — Python 3.12.2 documentation
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>