User Manual
AC1200 Dual Band XPON Terminal
Model: X122
X122 AC1200 Dual Band XPON Terminal
Package Content:
- X122 *1
- Power Adapter *1
- Quick Installation Guide *1
DECLARATION
This manual mainly introduces the function, use, operation method and so on of
the products. This manual is only used as a user guide, not as a service
basis. Due to continuous improvement of products, design and specifications
are subject to change without notice. Products in kind prevail. For details,
please check with the dealer.
PROMPT
Pictures used in this manual are for reference only. The information provided
in this manual may be amended without notice, and Micronet Union reserves the
right of final explanation of the said information.
Warnings and Precautions
- Before using and operating the equipment, please read and follow the following precautions to ensure that The standby performance is stable and dangerous or illegal situations are avoided.
- To reduce the risk of fire or electric shock, do not expose this device to rain or moisture. The device shall not be exposed to dripping or splashing and that objects filled with liquids, such as vases, shall not be placed on apparatus.
- The direct plug-in adaptor is used as disconnect device, the disconnect device shall remain readily operable.
- To reduce the risk of electric shock, do not remove cover (or back) as there are no user-serviceable parts inside. Refer servicing to qualified personnel.
- Use only the AC adapter which is included in the product package. Any other adapter may cause damage to the device. Such damage is not covered under warranty.
- The power adaptor is used as the power interrupting device. Please pay attention to safety plug and pull and convenient operation.
- Do not expose the appliance to naked flame sources (for example, lighted candles).
- Do not install the appliance in a confined space, such as a bookcase or built-in cabinet.
- Only accessories approved by the equipment manufacturer and compatible with this type of equipment can be used. If used Other types of accessories that may violate the warranty of the equipment and the country in which the equipment is located Relevant regulations and may lead to security incidents. To obtain approved accessories, please contact the authorization Contact the service center.
- Please use and store the equipment and its accessories within the temperature range of 0~55. When the temperature is over If the value is too high or too low, device faults may occur.
- Correct Disposal of this product. This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer or service operator where the product was purchased. They can take this product for environmental safe recycling.
Introduction
X122 is a gateway ONT that uses GPON/EPON technology to achieve ultra- broadband access for users. It supports 802.11ac dual-band WiFi, provides four GE Ethernet ports, one POTS voice port, and one USB port, and provides high- performance forwarding function to ensure high-quality voice, Internet, and high-definition video services.
Product Features
- EPON/GPON dual-mode access
- Dual band WIFI, with a physical air port speed of up to 1167Mbps
- Supports multiple services such as internet, WiFi, voice
- 2.5G downlink and 1.25G uplink compliant with ITU-T G.984 standard
- Compliant with IEEE802.3ah protocol standard, supports 1.25G symmetric rate
Technical Parameters
Module | Parameters |
---|---|
Product Size: | 186mm(L)x115mm(W)x39mm(H) |
Weight: | 340g |
Interfaces: | 4*10/100/1000M RJ45 port |
1POTS
1USB
2.4G Wi-Fi
5G Wi-Fi
PON:| EPON&GPON mode adaptive
Interface Type: SC-UPC/SC-APC
Security: ONU authentication mechanism Network Coverage Radius: 20KM
GPON: upstream 1.25Gbps/downstream 2.5Gbps
Optical Receive Sensitivity: -7dBm–28dBm
Continuous Light Power: 0.5dBm-SdBm
EPON: upstream 1.25Gbps/downstream 1.25Gbps
Optical Receive Sensitivity: -7dBm–27dBm
Continuous Light Power: OdBm-4dBm
Ethernet:| 4*10/100/1000M auto-negotiation
Full/half duplex mode
RJ45 connector
Auto MDI/MDI-X
100M Distance
WiFi:| Compliant with IEEE802.11b/g/n/ac
2.4GHz 2×2, 5.8GHz 2×2, 5dBi antenna
Rate up to 1.167Gbps
Rated Power Input:| 12VDC, 1A
Power Consumption| <12W
Operating Temperature &Humidity:| Operating Temperature: 0℃~55℃
Operating Humidity: 5%-95%(non-condensing)
Storage Temperature &Humidity &Humidity:| Storage Temperature: -10℃~70℃
Storage Humidity: 5%-95% (non-condensing)
Buttons:| Power ON/OFF,WPS,WLAN,RESET
LED Indicators:| Power,LOS,PON,LAN1-LAN4,NET,2.4G,5G,USB, VOIP
Interface and Button
Installation
- Take out the power adapter, plug the power connector into the device, and press the ON/OFF button to power on the device.
- Connect the optical Fiber cable to the PON port.
- Connect one end of the Ethernet cable to the LAN port, and the other end to your personal computer.
Configuration
- Use the SSID and Wireless password provided on the device label to establish a wireless connection. Locate the SSID on your smartphone or notebook, and enter the Wireless password when prompted to connect.
- Press the WPS button on the device, and observe the 2.4G indicator and 5G indicator blinking alternately. Subsequently, press the WPS button on the client device. In the event of a WPS method failure, utilize the SSID and wireless password to establish a WiFi connection.
- Open a web browser and navigate to http://192.168.1.1. Enter the default User Name and Login Password, then click Login. After successfully logging in, you can configure the settings on the web page.
LED Description
LED Status | Description |
---|---|
POWER | On |
Off | The power is off or faulty. |
LOS | Blinking |
Off | Optical signal is detected. |
PON | On |
Blinking | The ONT attempts to set up a connection with its upper-layer device. |
Off | The ONT is not connected to fibers or does not receive optical signals. |
LAN1
– LAN4| On| LAN port is properly connected.
Blinking| Data are being transmitted.
Off| LAN port is not connected.
NET| On| At least one WAN connection is up.
Off| All WAN connections are down.
2.4G| On| 2.4GHz Wi-Fi is turned on.
Blinking| 2.4GHz Wi-Fi data are being transmitted.
Off| 2.4GHz Wi-Fi is turned off.
5G| On| 5GHz Wi-Fi is turned on.
Blinking| 5GHz Wi-Fi data are being transmitted.
Off| 5GHz Wi-Fi is turned off.
USB| On| External device is connected.
Blinking| Data are being transmitted.
Off| No external device is connected.
VOIP| On| The VOIP server has been registered.
Blinking| The voice service is in use.
Off| The VOIP server is not registered.
Button Description
Button | Description |
---|---|
ON/OFF | Turn on/off the device. |
Reset | Press the button for 3 to 5 seconds to reboot the device. |
Press the button for more than 5 seconds to restore the factory settings.
WLAN| Press the button for 1 to 3s to enable or disable the WLAN function.
WPS| Press the button for more 1s to connect the device through WPS.
Manufacture Information
Manufacturer: Micronet Union Technology (Chengdu) Co., Ltd.
Address: Room 502, Building 5, No. 528, Yuefei Road, Shibantan Street, Xindu
District, Chengdu, Sichuan
Micronet Union Technology (Chengdu) Co., Ltd.declares that the AC1200 Dual
Band XPON Terminal is in compliance with Directive 2014/53/EU. The full text
of the EU declaration of conformity is available at the following internet
address: https://www.micronet-union.com
FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.