- Models 52, T52, 252, 552 Vertical Deadbolt Component Change- Retainer Clip 306111
- Impact Change in Spindle Length Requirement for Installation Change in Installation Instructions
dormakaba is pleased to share this technical update with our valued customers and service partners. Effective immediately a revision to installation hardware component 306111 (Retainer Clip , Push on- .186, Heat Treat, RoHS). A new version of this clip will be included in all Auditcon vertical deadbolt models. This change will impact the installation instructions for these locks. The new version of this retainer clip has been released to replace an end of life component.
PLEASE BE AWARE:
When installing a lock with the new retainer clip, mark and cut the spindle to
allow 1 3/8” (34.9mm) from the outside of the container door. (plus or minus
1/8” or 3.2mm) Previous Revisions of this clip required 1 ¼” (31.8mm) from the
outside of the container. This change in installation procedure is documented
in the installation instructions (3045.025) .
PLEASE TAKE ACTION:
Please update any documentation for your organization and notify service
personnel.