Zhongshan Zhonghua Intelligent Technology TY198 Device Instruction Manual
- June 5, 2024
- Zhongshan Zhonghua Intelligent Technology
Table of Contents
Zhongshan Zhonghua Intelligent Technology TY198 Device
Function
- Bluetooth unlock on phone
- Remote Distribution of electronic keys
- password unlock
- Fingerprint unlock
- Lock-picking records Surveillance
Performance parameter
Bluetooth Standard
- Bluetooth4.1 BLE
Supported Cell phone system
- Android4.3/1087.0AE
Power supply mode
- 4 Alkali-saving dry yellow Electricity alarm voltage:4.8V
Voltage range
- 4.59ViStandby Current:65 microamperes
Operating Current
- Less than 200 Mallock-picking time:1.5 s
Operating temperature range:-20-70 CI touch key Types
- Capacitive touch key
Number of passwords
- Custom and permanent passwords:150
Other dynamic passwords
- 150
Lock pick mode:
- APP, passwords, fingerprints, mechanical keys
Motor interface output voltage
- Battery voltage reduetion0.3V
Fingerprint head type
- Semiconductor fingerprint head
Fingerprint capacity
- 50 fingerprints
False Accept Rate
- <0.0016\False Reject Rate,<1.0%
Open lock
- Verify success green light, and “drip” a voice.
- Failure to verify red light, and a continuous urgent: Drip, drip, drip”voice.”
OFF Lock
- After the lock is opened, the lock is closed by 5s.
Low Electricity Quantity Reminder
- When the battery is low, after the success of the lock will be issued a continuous rapid: Di, di, di” voice.”. There is a battery indicator on the phone APP, and a low battery indicator appears when the phone is unlocked using Bluetooth.
- Can Still Open the lock 100 times after appearing the low electricity prompt. Please replaces the batteries to avoid affecting their normal use.
Fingerprint setup and user management
- Search for the “TTLOCK” APP on your phone, download it and open it on your phone.
- 0pen the phone Bluetooth, in the “lock all” APP, Click the ” number, select the “lock” , touch wake up the door lock, the phone will jump out of the door lock name, click add to become the door lock administrator.
- You can open the doordirectly by clicking on the”unlock icon”
- Click on the “fingerprint icon” and Click on the option in the upper right corner, you can add fingerprints, ACCording to the screen display operation.
- Click “send the key” and grant administrator” to add users and administer ators, according to this screen prompt for action.
- Set paswords and delete passwords Click “get password” on the APP, select the password type: custom selection validity period, click to set the password to enter the need to add the password., ac cording to the screen display operation. Click password management” on the APP, click the password to be deleted, click delete, according to the screen operation.
Remove fingerprints and devices
- Click on the fingerprint on the APP, Click on the fingerprint to be deleted, and click on delete according to the prompt on the screen.
- Select the lock in the APP that requires you to remove the phone’s administrator, click Settings, and click delete. Follow the instructions on the screen.
Check Lock picking records
- Select the lock on the APP, Click on the operating record to view,click on the APP a fingerprint, Password, click on the operating record, view the fingerprint and Password of all records.
Normally open mode switch
- After press the handle of the normally open key loosen after 1 second, long drops” Which is set as normally open mode, repeat operation can be switched into automatic locking or normally open mode again.
Restore factory settings
- Four seconds after long-pressing the reset button on the lock, two clicks are heard.
- The lock has been reset to factory settings, and all fingerprints, passwords, and phone administrators are cleared out.
FCC STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Any changes or
modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.