Continental Edison CEHD6065B Black Decorative Hood Installation Guide
- June 16, 2024
- Continental Edison
Table of Contents
Warnings and installation
CEHD6065B Black Decorative Hood
CEHD6065B
CEHD9065B
The product is designed for the extraction of cooking fumes and steam and it
is for domestic use only.
Strictly observe the instructions in this manual. No liability shall be
accepted for any inconvenience, damage or fire caused to the product as a
result of not following the instructions given in this manual.
The device may have different aesthetic features with respect to the
illustrations in this handbook, however the operating, maintenance and
installation instructions remain the same.
-
It is important to keep all the manuals accompanying the product so that they can be consulted at all times.
If sold, transferred or moved, make sure it remains with the product. -
Read the instructions carefully: they contain important information on installation, operation and safety.
-
Check the integrity of the product prior to its installation.
Otherwise, contact the dealer and do not continue with the installation.
NOTES
***** : the items marked with this symbol are optional accessories supplied
only with some models or items that cannot be supplied but can be purchased.
SAFETY AND REGULATIONS
GENERAL SAFETY
- Do not make electrical or mechanical changes on the product or on the exhaust pipes.
- Before doing any cleaning or maintenance work, disconnect the product from the mains power supply by removing the plug or turning off the mains switch.
- For all installation and maintenance operations, always wear work gloves.
- The product can be used by children over the age of 8 and by people with reduced physical, sensory or mental capabilities or without experience or the necessary knowledge, as long as they are properly supervised or have been instructed on how to safely use the device and understand the inherent dangers.
- Children must be supervised to make sure that they do not play with the product.
- Cleaning and maintenance must never be performed by children unless they are properly supervised.
- The room must have sufficient ventilation when the product is used at the same time as other appliances burning gas or other fuels.
- The product must be cleaned frequently both inside and out (AT LEAST ONCE A MONTH); always follow the instructions given in the maintenance manual.
- Failure to comply with the rules indicated for cleaning the product and replacing/cleaning the filters may result in the risk of fire.
- It is strictly forbidden to cook food on the flame under the product.
- WARNING: When the hob is on, the accessible parts of the product may become hot.
- Do not connect the product to the electrical power supply until the installation is complete.
- The regulations laid down by local authorities must be strictly followed with regard to the technical and safety measures to adopt for fume extraction.
- The extracted air must not be conveyed through the same ducts used to extract the fumes generated by gas combustion or other types of combustion products.
- Do not use or leave the product without appropriately installed lamps, as this may result in the risk of electric shock.
- The product must NEVER be used without the grille correctly fitted.
- The product must NEVER be used as a support surface unless expressly indicated.
- Range hoods and other cooking fume extractors may adversely affect the safe operation of appliances burning gas or other fuels (including those in other rooms) due to back flow of combustion gases. These gases can potentially result in carbon monoxide poisoning. After installation of a range hood or other cooking fume extractor, the operation of flued gas appliances should be tested by a competent person to ensure that back flow of combustion gases does not occur.
- To replace the lamp, only use the lamp indicated in the maintenance/lighting system section of this manual.
- Using a naked flame may damage the filters and cause a fire hazard, and must therefore be avoided under all circumstances.
- Extra care must be taken when frying to prevent the oil from overheating and catching fire.
- In case of doubt, contact the authorised service centre or similar qualified personnel.
INSTALLATION SAFETY
- All installation work must be carried out by a competent person or a qualified electrician.
- This appliance must be installed correctly by qualified personnel, strictly following the manufacturer’s instructions.
- Check for accessories (e.g. bags containing screws, warranty certificates, etc.) inside the product (placed there for transport reasons). If there are any, remove them and keep them safe.
- WARNING: Failure to install screws and fasteners in accordance with these instructions may result in electrical hazards.
- The exhaust pipe is not supplied and must be purchased.
- The diameter of the exhaust pipe must be equivalent to the diameter of the connecting ring.
- For installation of the product on the hob, respect the height indicated in the drawings
- The minimum distance between the surface of the container supports on the cooker and the lowest part of the range hood must not be less than 50 cm (not less than 65 cm only for Australia and New Zealand) for electric cookers and 65 cm for gas or mixed cookers.
- If the installation instructions of the gas cooker specify a greater dis- tance, take it into account.
ELECTRICAL CONNECTION SAFETY
- The mains voltage must correspond to the voltage indicated on the label found inside the product.
- If it features a plug, connect the product to a socket that complies with current standards, located in an area accessible even after installation.
- If it does not feature a plug (direct connection to the mains) or the plug is not located in an accessible area, even after installation, apply a standard double pole switch that ensures complete disconnection from the mains in category III overvoltage conditions, in accordance with the installation rules.
- Warning! The power cable must be replaced by the authorised technical support service or by a person with similar qualifications.
- Please note! Before reconnecting the circuit to the mains power supply, make sure that it is working correctly, always check that the power cable is correctly installed.
Please note! Do not use with a programmer, timer, separate remote control or any other device that activates automatically.
RECOMMENDATIONS FOR USE
Recommendations for correct use in order to reduce the impact on the
environment: When cooking begins, the device should be turned on at minimum
speed, and left on for a few minutes even after cooking is complete. Increase
the speed only if there is a large quantity of fumes and steam, using the
Booster function only in extreme cases. To keep the odour reduction system
running efficiently, replace the carbon filter/s when necessary. To ensure the
high performance of the grease filter, clean it when necessary. To improve
efficiency and minimise noise, use the maximum duct diameter indicated in this
manual.
END-OF-LIFE DISPOSAL
This appliance is marked with the separate collection symbol for waste
electrical and electronic equipment (WEEE).
This means that this product must be taken care of by a separate collection
system in accordance with the European Directive 2012/19/EC in order to be
disassembled or recycled, and thus reduce the impact on the environment.
For more information, you can contact the local administration (municipality)
or regional.Electronic products that have not undergone selective sorting are
potentially dangerous for the environment due to the presence of hazardous
substances.
IMPORTANT: Under no circumstances should you dispose of your device or
battery on public roads.
REGULATIONS
Equipment designed, tested and manufactured in compliance with safety
regulations: EN/IEC 60335-1; EN/IEC 60335-2- 31, EN/IEC 62233. Performance:
EN/IEC 61591; ISO 5167-1; ISO 5167-3; ISO 5168; EN/IEC 60704-1; EN/
IEC 60704-2-13;EN/IEC 60704-3; ISO 3741; EN 50564;
IEC 62301. EMC: EN 55014-1; CISPR 14-1; EN 55014-2;
CISPR 14-2; EN/IEC 61000-3-2; EN/IEC 61000-3-3.
USE
The extraction system can be used in the duct-out version with external
evacuation, or in the recirculating version with filtering and internal
recirculation.
Duct-Out Version:
Vapours are evacuated outside through an exhaust pipe attached to the
connecting flange.
CAUTION! If the product features one or more carbon filters, they must be
removed.
Connect the product to wall-mounted exhaust pipes and holes with a diameter
equivalent to the air outlet (connecting flange).
The use of pipes and outlet holes in the wall with a smaller diameter will
reduce the extraction performance and drastically increase the noise level.
All responsibility in this regard is therefore denied.
- Use a ducting pipe with the shortest length necessary.
- Use a ducting pipe with the least number of bends possible (maximum bend angle: 90°).
- Avoid drastic changes in the ducting pipe diameter.
Recirculating Version:
The suctioned air will be degreased and deodorised before it is sent back into
the room. To use the product in this version, it is necessary to install an
additional activated carbon filter system.
ASSEMBLY BEFORE INSTALLATION
-
Check that the product is the right size for the installation area.
-
Remove the activated carbon filter(s) if supplied (see also relevant paragraph).
-
It(they) must be reinstalled if the product is used in the filter version.
-
If there are panels and/or walls and/or wall units on the sides, make sure that there is enough space to install the product and that it is always possible to access the control panel easily.
-
Do not make any modifications to the device or its mounting bracket on the wall!
-
Ask a professional to fix the hood to the wall.
-
The wall on which the hood will be fixed must be in good condition and must not show any damage (cracks, subsidence, humidity, etc.). It must also be strong enough to support the weight of the hood.
-
Do not drill a hole close to old holes, even filled ones.
-
It is essential to consult a building professional to use the anchoring system (screws, dowels, etc.) appropriate to the material that makes up your wall, as well as to the weight of the appliance. Respect the diameter of the fixing screws indicated in this manual.
Note: The fixing screws and dowels supplied with the product can only be used if they are suitable for your wall type. If the screws and dowels provided are not suitable for the type of your wall, it is essential to use an appropriate system recommended by the professional installer. -
The holes intended for fixing the appliance or its mounting bracket to the wall must not be modified.
-
The wall must be drilled using a drill of the correct size for the anchoring system.
-
Regularly check the fixing points of the appliance on the wall. Tighten them if necessary.
OPERATION
To select the functions of the hood just touch the commands.
T1= Motor key OFF (stand by) – excludes the electronics reset wash/replace
filters signals.
MOTOR OFF
Press briefly to switch the motor off.
RESET FILTERS SIGNALS
In functioning mode, after carrying out filter maintenance, press the key
until hearing the sound signal. The flashing LED 1 (grease filter) or 2
(carbon filter) stops flashing.
EXCLUDING THE ELECTRONICS
Press the key for 3 seconds. The hood command electronics will be excluded.
This function can be useful during the product cleaning operations. Just
repeat the operation to reinsert the electronics.
T2= Low-speed selection key (suction power) — when flashing it indicates the
need to wash the fats filter.
T3= Medium-speed selection key (suction power) – when flashing it indicates
the need fo wash or replace the carbon filter. This signal is normally
deactivated. To activate the alarm, disable the electronic by pressing the 0
button for 3 seconds. Next, simultaneously press buttons 1 and 2 for 3
seconds; at first, only button 1 will flash, then both buttons 1 and 2 will
flash to indicate activation. Repeat the procedure to deactivate the alarm; at
first buttons 1 and 2 will flash and subsequently only button 1 to indicate
deactivation.
T4= High-speed selection key (suction power).
T5= Intensive speed selection key (suction power) – duration 5 minutes: the
hood sets this power and at the end of the 5 minutes returns to the previous
setting.
T6= Light key ON/OFF
If the hood fails to operate correctly, briefly disconnect it from the mains
power supply for almost 5 sec. by pulling out the plug. Then plug it in again
and try once more before contacting the Technical Assistance Service.
MAINTENANCE WARNINGS
-
Cleaning: For cleaning, simply use a cloth moistened with neutral liquid detergents. Do not use cleaning tools or instruments.
For product maintenance, see the images at the end of the installation marked by this symbol. -
Anti-Grease Filter: The metallic anti-grease filter must be cleaned once a month with non-aggressive detergents, manually or in a dishwasher on a short wash at low temperatures.
To remove the anti-grease filter, pull the spring release handle. -
The Anti-Grease Filter traps the grease particles produced during cooking. When cleaned in the dishwasher, the metal grease filter may discolour, but its filtering characteristics remain unchanged.
-
Carbon filter (for filter version only): The cartridge must be replaced at least every four months. It CANNOT be washed or regenerated. As indicated in the drawings section: remove the anti-grease filters, apply a carbon filter on each side and attach it to the product. Put the anti-grease filters back in place.
-
The carbon filter retains any unpleasant odours produced during cooking.
-
The saturation of the carbon filter can occur after somewhat prolonged use depending on the type of cooking and how regularly the grease filter is cleaned.
Illumination
- The lighting system is based on LED technology. LEDs provide optimal illumination, last up to 10 times longer than conventional lamps and save 90% of electricity.
- Lighting system : The lighting system cannot be replaced by the user, contact Customer Service in case of malfunction.
Model: CEHD6065B – CEHD9065B
Product Fiche compliant to commission delegated regulation (EU) No 65/2014
| Value| Unit
---|---|---
Annual Energy Consumption – AEChood| 47.| kWh/a
Energy Efficiency Class| A|
Fluid Dynamic Efficiency – FDEhood| 32.| %
Fluid Dynamic Efficiency class| A|
Light Efficiency – LEhood| 76.| lux/W
Lighting Efficiency Class| A| lux
Grease Filtering Efficiency – GFEhood| 45.| %
Grease Filtering Efficiency class| F|
Minimum Air Flow in normal use| 270.0| m3/h
Maximum Air Flow in normal use| 490.0| m3/h
Air Flow at intensive/boost setting| 640.0| m3/h
A-waighted Sound Power Emission at minimum speed| 49.0| dB(A) re 1pW
A-waighted Sound Power Emission at maximum speed| 62.0| dB(A) re 1pW
A-waighted Sound Power Emission at intensive or boost speed| 68.0| dB(A) re
1pW
Power consumption off mode – Po| NA| W
Power consumption in standby mode – Ps| 0.49| W
Additional Product Information compliant to commission regulation (EU) No 66/2014 and UK SI 2019 No. 539
| Symbol| Value| Unit
---|---|---|---
Time increase factor| f| 0.9|
Energy Efficiency Index| EElhood| 51.0|
Measured air flow rate at best efficiency point| QBEP| 355.0| m’/h
Measured air pressure at best efficiency point| PBEP| 440.0| Pa
Maximum air flow| Qmax| –| m’/h
Measured electric power input at best efficiency point| WBEP| 138.| W
Nominal power of the lighting system| WL| 3.| W
Average illumination of the lighting system on the cooking surface| Emiddle|
198.0| lux
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>