Mammoth P6SD-X Air Conditioner Packaged Owner’s Manual
- June 15, 2024
- MAMMOTH
Table of Contents
Mammoth P6SD-X Air Conditioner Packaged
Single Packaged Air Conditioning, 13 SEER
3, 4, 5 Ton Units
The P6 Series single-packaged air conditioners are high-efficiency self- contained cooling units that can be installed on a roof or on a slab. The convertible unit design makes installations simple in all applications. Units are ETL and ETLc listed.
FEATURES and BENEFITS
- State-of-the-art Copeland Scroll compressor is standard equipment.
- Proven, Industry Standard Components Easier service and availability.
- TXV Externally Equalized Provides precise refrigerant control under varying load conditions.
- High and Low Pressure Switches Added compressor protection.
- Liquid Line Filter Drier Ensures clean and dry refrigeration system.
- Externally Accessible Service Ports Quick access to the refrigerant system without disrupting operation.
- Compact Footprint/Low Profile Easy to handle and transport.
- Convertible Air Delivery Horizontal or downflow to accommodate rooftop or horizontal application.
- Heavy-gauge, Full Perimeter Base Rails Facilitate forklift handling and curb mounting.
- The Galvanized Steel Cabinet Polyurethane finish provides 950 hours of salt spray protection.
- Wire Guard Coated with Earth-Friendly Epoxy and Mesh Hail Guard Will never rust and protects the coil from being damaged by balls, lawnmowers, hail etc.
- Corrosion-Resistant Drain Pan Quickly drains away evaporator condensate.
- Quiet Operation and Vibration 20″ fan blade combined with custom venturi condenser fan.
- Access to Controls and Major Components Easy in and out service.
- Service Access Panels Allow easy access to all major components and the compressor. Designed to make servicing easier for the Contractor.
- Easy to Install Electric heat strip provides up to 20 KW of heat output.
- Accessories Roof curbs, economizers, fresh air dampers and more.
MODEL IDENTIFICATION CODE
DIMENSIONS
DIMENSIONS (Continued)
SPECIFICATIONS
Model Number | P6SD |
---|---|
X36K | X48K |
Performance | |
Capacity -Cooling BTUH | 34,200 |
Efficiency – SEER | 13.3 |
EER (Btuh/watt) | 11.2 |
Electrical Rating – 60 Hz | |
Phase | 1 |
Operating Voltage Range | 187 – 253 |
Compressor Data | |
Volts | 208 / 230 |
Rated Load Amps | 18.6 |
Lock Rotor Amps | 79 |
Indoor Blower | |
Type / No. of Speeds | DD / 3 |
Motor – HP / RPM | 1/4 – 1075 |
Motor – Amps | 1.3 |
Outdoor Fan | |
Motor – HP / RPM | 1/4 – 1100 |
Motor – Amps | 1.2 |
Fan Diameter / CFM | 20/3600 |
Refrigerant Charge – Oz. | 110 |
Shipping Weight | 415 |
BLOWER PERFORMANCE
Model Number | External Static Pressure Drop – inches water column |
---|---|
P6SD- | 0.1 |
0.7 | 0.8 |
X36
| High| 1610| 1562| 1504| 1442| 1365| 1295| 1214| 1109
Medium| 1367| 1320| 1271| 1205| 1138| 1065| 968| 845
Low| 1153| 1102| 1043| 990| 912| 831| 731| 618
X48
| High| 2361| 2278| 2218| 2141| 2066| 1976| 1870| 1758
Medium| 2026| 1982| 1935| 1889| 1822| 1744| 1660| 1554
Low| 1584| 1568| 1532| 1489| 1445| 1387| 1322| 1236
**X60 ***
| Tap T1| 1515| 1450| 1380| 1350| 1280| 1250| 1200| 1160
Tap T2| 1580| 1520| 1460| 1400| 1300| 1280| 1260| 1230
Tap T3| 1740| 1690| 1650| 1600| 1360| 1500| 1460| 1390
Tap T4| 1960| 1910| 1840| 1820| 1540| 1740| 1700| 1600
Tap T5| 2090| 2050| 2010| 1975| 1780| 1900| 1850| 1790
- Denotes factory-set cooling speed
- Denotes factory-set electric heating speed
- NOTE: Airflow performance is with a dry coil
MODEL IDENTIFICATION CODE
HEATER APPLICATION MATRIX
ELECTRICAL DATA
P6SD SERIES – 208/230V – SINGLE PHASE MODELS
MODEL NUMBER P6SD-
| ****
HEATER INSTALLED NOMINAL KW
| SINGLE CIRCUIT| MULTIPLE SUPPLY CIRCUIT OPTION
mCA
| ****
mOP
| CIRCUIT A
(C ompressor & F an )
| CIRCUIT B
(B lower & H eater )
mCA
| ****
mOP
| ****
mCA
| ****
mOP
X36K
| 0| 25.8| 40| –| –| –| –
5| 26.5| 40| –| –| –| –
8| 41.2| 45| –| –| –| –
10| 51.6| 60| –| –| –| –
15| 76.6| 80| 50.0| 60| 26.6| 30
X48K
| 0| 32.9| 50| –| –| –| –
5| 32.9| 50| –| –| –| –
8| 41.2| 50| –| –| –| –
10| 51.6| 60| –| –| –| –
15| 76.6| 80| 51.6| 50| 26.6| 30
20| 101.6| 110| 50| 50| 51.6| 60
MODEL NUMBER P6SD-
| ****
HEATER INSTALLED NOmINAL KW
| SINGLE CIRCUIT| MULTIPLE SUPPLY CIRCUIT OPTION
mCA
| ****
mOP
| CIRCUIT A
(C ompressor , B lower , & F an )
| CIRCUIT B
(H eater o nly )
| CIRCUIT C
(H eater o nly )
mCA
| ****
mOP
| ****
mCA
| ****
mOP
| ****
mCA
| ****
mOP
X60K
| 0| 43.8| 70| –| –| –| –| –| –
5| 43.8| 70| –| –| –| –| –| –
8| 43.8| 70| –| –| –| –| –| –
10| 51.5| 70| 43.8| 70| 50| 60| –| –
15| 76.5| 80| 51.5| 70| 25| 30| –| –
20| 101.5| 110| 43.8| 70| 50| 60| 50| 60
NOTE: P6SD 3 & 4-ton models have PSC motors. Since the power wires run through the heater plug, keep the blower and heater on different circuits when adding a heater kit.
COPPER WIRE SIZE — AWG
(1% Voltage Drop)
Supply Wire Length-Feet| Supply Circuit Ampacity
200| 150| 100| 50
6| 8| 10| 14| 15
4| 6| 8| 12| 20
4| 6| 8| 10| 25
4| 4| 6| 10| 30
3| 4| 6| 8| 35
3| 4| 6| 8| 40
2| 3| 4| 6| 45
2| 3| 4| 6| 50
Wire Size based on N.E.C. for 60° type copper conductors.
ACCESSORIES
Description | Part Number |
---|---|
Roof Curb (8”) | 547830 |
Roof Curb (14”) | 547831 |
Roof Curb (18”) | 547850 |
Roof Curb (24”) | 547851 |
Supply/return transition, 16” | 547834 |
Supply/return transition, 18” | 547835 |
Concentric diffuser, flush, 16” | 547836 |
Concentric diffuser, flush, 18” | 547837 |
Concentric diffuser, step down 16” | 547838 |
Concentric diffuser, step down 18” | 547839 |
Manual Fresh Air Damper | 547832 |
Motorized Fresh Air Damper | 547840 |
Economizer, downflow w/filter (does not require filter kit) modulating | 558870 |
Economizer, horizontal modulating | 547841 |
Power Exhaust, downflow economizer (special order) | 547842 |
Power Exhaust horizontal economizer (special order) | 547843 |
Hood Type Hail Guard 34” X 76” P6SD-X36, P6SD-X48 | 547846 |
Hood Type Hail Guard 38” X 76” P6SD -X60 | 547847 |
Duct Smoke Detector Photo Elec | 558863 |
Multi Signal Control | 558866 |
Sampling Tube DST5, 2-4′ | 558864 |
Sampling Tube DST5, 4-8′ | 558865 |
Filter Rack, All Downflow Applications (not required with economizer) | 547885 |
Filter Kit (not required with economizer) P6SD-X36, P6SD-X48 | 547887 |
Filter Kit (not required with economizer ) P6SD-X60 | 547888 |
Universal Hard Start Kit | 912933 |
Low Ambient Kit | 918837 |
Skirt Trim Kit | 919729 |
Heater Kit – 4-Pole single circuit adaptor | 913350 |
Heater Kit – 6-Pole single circuit adaptor | 913556 |
Heater Kit – Circuit breaker single phase (2-pole) | 913554 |
Freezestat Kit | 917108 |
Outdoor Tstat Kit | 913852 |
Duct Adapter, 12″ Round (2 each) | 913811A |
Duct Adaptor, 14″ Round (2 each) | 913812A |
Control, CO2 sensor, wall mount | 547848 |
COOLING EXPANDED RATINGS
P6SD-X36
O.D.T | 85°F | 95°F | 105°F | 115°F |
---|---|---|---|---|
CFm | E.D.B. | E.W.B. | T.C. | S.C. |
T.C. | S.C. | K.W. | T.C. | S.C. |
S.C. | K.W. |
900
| 80| 62| 32.7| 26.3| 2.67| 31.2| 26.4| 2.95| 29.6| 27.2| 3.27| 27.9| 26.8|
3.64
80| 67| 35.6| 21.3| 2.70| 33.9| 20.7| 2.98| 32.1| 20.2| 3.30| 30.1| 19.5| 3.67
80| 72| 38.9| 16.3| 2.75| 37.1| 15.8| 3.03| 35.2| 15.2| 3.34| 33.1| 14.7| 3.71
75| 63| 33.1| 21.0| 2.68| 31.5| 21.1| 2.95| 29.8| 21.0| 3.28| 28.0| 20.6| 3.64
1000
| 80| 62| 33.5| 28.0| 2.68| 31.9| 29.0| 2.96| 30.3| 29.0| 3.28| 28.7| 28.7|
3.65
80| 67| 36.2| 22.5| 2.71| 34.4| 22.0| 2.99| 32.6| 21.4| 3.31| 30.7| 20.9| 3.67
80| 72| 39.6| 17.1| 2.76| 37.8| 16.6| 3.04| 35.8| 16.0| 3.35| 33.7| 15.5| 3.72
75| 63| 33.7| 23.1| 2.68| 32.0| 22.9| 2.96| 30.4| 22.8| 3.28| 28.6| 22.2| 3.65
1100
| 80| 62| 34.7| 31.2| 2.69| 33.1| 31.3| 2.97| 31.6| 31.6| 3.30| 29.9| 29.9|
3.66
80| 67| 37.3| 24.5| 2.73| 35.5| 23.9| 3.00| 33.6| 23.2| 3.32| 31.6| 22.6| 3.69
80| 72| 40.7| 18.2| 2.77| 38.8| 17.7| 3.05| 36.7| 17.2| 3.37| 34.5| 16.6| 3.73
75| 63| 34.8| 26.0| 2.70| 33.1| 25.6| 2.97| 31.3| 24.9| 3.29| 29.4| 24.2| 3.66
P6SD-X48
O.D.T | 85°F | 95°F | 105°F | 115°F |
---|---|---|---|---|
CFm | E.D.B. | E.W.B. | T.C. | S.C. |
T.C. | S.C. | K.W. | T.C. | S.C. |
S.C. | K.W. |
1250
| 80| 62| 44.1| 35.7| 3.45| 42.2| 36.0| 3.84| 40.0| 37.1| 4.27| 37.8| 36.6|
4.77
80| 67| 47.9| 28.8| 3.50| 45.5| 28.0| 3.87| 43.1| 27.2| 4.31| 40.6| 26.7| 4.80
80| 72| 52.1| 21.9| 3.54| 49.5| 21.2| 3.92| 46.9| 20.5| 4.35| 44.2| 19.8| 4.85
75| 63| 52.1| 16.3| 3.54| 49.5| 16.7| 3.92| 47.0| 16.7| 4.35| 44.2| 16.4| 4.85
1400
| 80| 62| 45.2| 38.2| 3.46| 43.1| 39.5| 3.85| 41.0| 39.5| 4.29| 39.0| 39.0|
4.78
80| 67| 48.7| 30.6| 3.51| 46.3| 29.8| 3.88| 43.9| 29.4| 4.32| 41.4| 28.6| 4.81
80| 72| 52.9| 23.1| 3.54| 50.4| 22.4| 3.93| 47.7| 21.6| 4.36| 44.9| 20.9| 4.86
75| 63| 53.1| 18.2| 3.55| 50.5| 18.2| 3.93| 47.7| 17.9| 4.36| 45.0| 17.4| 4.86
1550
| 80| 62| 46.2| 41.8| 3.47| 44.2| 41.9| 3.86| 42.2| 42.2| 4.30| 40.1| 40.1|
4.80
80| 67| 49.6| 32.7| 3.51| 47.1| 32.0| 3.89| 44.6| 31.2| 4.33| 42.0| 30.4| 4.82
80| 72| 53.8| 24.2| 3.55| 51.1| 23.5| 3.95| 48.4| 22.8| 4.37| 45.5| 22.0| 4.86
75| 63| 53.8| 20.3| 3.55| 51.1| 19.8| 3.95| 48.4| 19.2| 4.37| 45.5| 18.4| 4.87
P6SD-X60
O.D.T | 85°F | 95°F | 105°F | 115°F |
---|---|---|---|---|
CFm | E.D.B. | E.W.B. | T.C. | S.C. |
T.C. | S.C. | K.W. | T.C. | S.C. |
S.C. | K.W. |
1600
| 80| 62| 56.7| 45.9| 4.53| 54.1| 46.1| 5.02| 51.3| 47.5| 5.57| 48.4| 46.7|
6.19
80| 67| 61.2| 37.4| 4.62| 58.1| 36.4| 5.09| 55.0| 35.3| 5.65| 51.7| 34.2| 6.26
80| 72| 66.6| 28.6| 4.72| 63.1| 27.7| 5.20| 59.5| 26.8| 5.75| 55.7| 25.7| 6.36
75| 63| 57.0| 36.9| 4.54| 54.2| 37.0| 5.02| 51.2| 36.7| 5.57| 48.2| 36.0| 6.18
1750
| 80| 62| 57.8| 48.3| 4.59| 55.1| 49.9| 5.07| 52.2| 49.9| 5.62| 49.3| 49.2|
6.24
80| 67| 62.0| 39.2| 4.67| 58.9| 38.1| 5.14| 55.7| 37.0| 5.70| 52.3| 35.8| 6.31
80| 72| 67.1| 29.8| 4.77| 63.5| 28.8| 5.24| 59.9| 27.8| 5.79| 56.2| 26.8| 6.41
75| 63| 57.8| 40.1| 4.59| 54.9| 39.8| 5.07| 51.9| 39.1| 5.62| 48.8| 38.1| 6.23
1900
| 80| 62| 58.7| 52.1| 4.64| 56.0| 52.2| 5.13| 53.1| 53.0| 5.68| 50.4| 50.4|
6.30
80| 67| 62.7| 40.9| 4.72| 59.6| 39.8| 5.20| 56.3| 38.7| 5.75| 52.8| 37.5| 6.36
80| 72| 67.5| 30.9| 4.81| 64.0| 29.9| 5.29| 60.5| 28.8| 5.84| 56.7| 27.7| 6.46
75| 63| 58.5| 43.5| 4.64| 55.6| 42.7| 5.12| 52.5| 41.6| 5.66| 49.3| 40.3| 6.28
WARRANTY
GENERAL TERMS OF LIMITED WARRANTY
Nortek Global HVAC, LLC will furnish a replacement for any part of this
product that fails in normal use and service within the terms and conditions
of the warranty.
For complete details of the Limited Warranty, including applicable terms and
conditions, see your local installer or contact the Nortek Global HVAC, LLC
warranty department for a copy.
CONTACT
- Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.
- Specifications and illustrations are subject to change without notice and without incurring obligations. Printed in U.S.A (10/2015)
- 800C-1014 (Replaces 800C-0910)
- www.mammothlc.com.
- Trademark Mammoth® used under license. © Nortek Global HVAC, LLC. All Rights Reserved.