VIMAR 01506 Well Contact Plus Instruction Manual

June 15, 2024
VIMAR

01506 Well Contact Plus
Instruction Manual

01506 Well Contact Plus

WELL-CONTACT PLUS
01506

By-me KNX TP Router, KNX Secure standard, installation on DIN rail (60715 TH35), occupies 2 modules size 17.5 mm.
The By-me/KNX router enables communication between parts of a system comprising By-me devices, grouped together within an “island”, with a system comprising KNX devices. The messages are transmitted in both directions according to criteria which define the correspondence of the communication objects belonging to the specific domains. The router allows up to 450 routing rules. Each rule is specified by the By-me group address, by the KNX address, by the direction of communication (from KNX to By-me; from By-me to KNX; both) and by the type of information exchanged (1 bit, 2 bit, …).
The device is equipped with a TP terminal for connection to the By-me BUS, a TP terminal for connection to the KNX BUS Abd a front push button for configuration via ETS. The power supply is provided by the By-me BUS.
Router 01506 conforms to the KNX Secure requirements on the data points defined in the routing table. A data point on the KNX side can be defined for the heartbeat signal.
CHARACTERISTICS:

  • Rated supply voltage: BUS 21- 30 V DC (SELV)

  • Max current consumption: < 10 mA
    – 7 mA on the By-me bus
    – 2 mA on the KNX line

  • Dissipated power:
    – 800 mW average
    – 1100 mW maximum

  • Operating temperature: – 5°C to + 45°C (indoor use)

  • IP20 protection degree

  • Protection class III

  • Overvoltage category III

  • 2 modules of 17.5 mm

CONNECTIONS.
The connection to the bus is made directly from the By-me BUS terminal on the front of the device. The TP terminal is available for connection to the KNX network. The router can be installed inside mounting boxes or panels, surface mounting or flush mounting with DIN rail (60715 TH35).
CONFIGURATION.
Configuration of the By-me Plus system is carried out using the View Pro App updated to the latest version (gateway 01410-01411 must be present). On completion, all the information about the By-me devices can be exported to an XML  file and made available on KNX. The KNX part is configured using the ETS software; a dedicated component, referred to as a DCA (Device Configuration App), allows you to define the routing rules for the exchange of messages. The purpose of the DCA is to define the Communication Objects of the device and allow association of the By-me group address for each one. Configuration of the KNX group associated with the Communication Object will be carried out using the standard ETS interface.
The DCA simplifies configuration operations thanks to the copy communication object function. The copying (cloning) of an entire router is permitted by the standard ETS functions.
To begin configuring the device and assigning the respective physical address, press the configuration push button.
All the updated ETS databases can be downloaded from the “Software” section of the website www.vimar.com.
DEVICE RESET.
Press push button G (LEDs A and B light up) and hold it down for approximately 10 s. When the LEDs are turned off, release the push button and press it again for approx. 1 s.
INSTALLATION RULES.

  • Installation must be carried out by qualified persons in compliance with the current regulations regarding the installation of electrical equipment in the country where the products are installed.
  • Switch off the power supply before beginning installation.
  • Carefully carry out the electrical insulation when making the connections.
  • Make sure you keep the 120/230 V lines separate from the SELV conductors.

CAUTION: Installation of 120/230 V power lines must only be carried out by qualified persons.

REGULATORY COMPLIANCE.

EMC directive. RoHS directive.
Standards EN IEC 62368-1, EN IEC 61000-6-2, EN IEC 61000-6-3, EN IEC 63044, EN IEC 63000.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
WEEE – User information
The crossed bin symbol on the appliance or on its packaging indicates that the product at the end of its life must be collected separately from other waste. The user must therefore hand the equipment at the end of its life cycle over to the  appropriate municipal centers for the differentiated collection of electrical and electronic waste. As an alternative to independent management, you can deliver the equipment you want to dispose of free of charge to the distributor when  purchasing a new appliance of an equivalent type. You can also deliver electronic products to be disposed of that are smaller than 25 cm for free, with no obligation to purchase, to electronics distributors with a sales area of at least 400 m² . Proper sorted waste collection for subsequent recycling, processing and environmentally conscious disposal of the old equipment helps to prevent any possible negative impact on the environment and human health while promoting  the practice of reusing and/ or recycling materials used in manufacture.

FRONT VIEW AND CONNECTIONS

VIMAR 01506 Well Contact Plus - CONNECTIONS

A: By-me BUS line status LED
B: KNX line status LED
C: Traffic on By-me BUS line LED
D: Traffic on KNX line LED
E: GA LED| F: PA LED
G: Reset push button
H: By-ME BUS line
I: Configuration LED
L: Configuration push button
M: KNX line
---|---

DESCRIPTION OF LEDS

| Green| Red
---|---|---
By-me BUS line status LED (A)| ON: Correct operation| ON: Device factory reset
KNX line status LED (B)
By-me BUS line traffic LED (C)| ON: Data traffic presence| –
KNX line traffic LED (D)
GA LED (E)| –| ON: Device not configured
PA LED (F)
Configuration LED (I)| –| ON: Device in the configuration phase

Viale Vicenza 14
36063 Marostica VI – Italy
www.vimar.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals