INTRODUCTION
DT16 is a dual technology curtain sensor, PIR and MW. It used for doors and windows protection. It has an adjustable range from 2mt to 3.5mt. And is equipped with a system for the recognition the direction of alarm. The lens used in the infrared has the ability to be rotated horizontally so you can install the sensor in 2 diffrenti guidelines (vertical and horizontal on demand)
DESCRIPTION OF THE FUNCTION: DIRECTION ALARM
The sensor is able to detect the direction of movement so as to trig in alarm
only when the passage is made in a given sense. Activation is done by DIP4 ON
(see note). (with DIP4 OFF, the sensor triggers an alarm in both directions)
The selection of the sense of alarm is handled through the DIP3. This function
is intended for applications where the sensor is installed on the windows and
/ or doors often open, and there is continuous passage on the inner side.
The passage in NOT PERMITTED direction, generates immediate alarm signaling
with LED lights outside.
The passage in PERMITTED direction generates the activation of the inhibition
time of 2 minutes, with the relative signal by short flash of the LED every 2
seconds. During this time period (2 minutes) there any violation of the sensor
will not generate alarm.
During the last 10 seconds of the period of inhibition, the LED will begin to
flash rapidly to indicate that the sensor will return in the operating status
and will be able to generate alarm.
Example: If the sensor is installed on access to a terrace, it is possible
come and go for 2 minutes without generating an alarm.
After this time, the sensor will be operative, giving alarm in the programmed
direction.
note: the dip 4 function (in ON) is not IMQ certified
LENS AND DIP-SWITCH SETUP – LED INDICATION
The sensor is designed to be installed to protect the openings, for example
between the window and the shutter, or to doors and gates. Due to the high
angle of coverage and the ability to rotate the lens on the support of the
pyroelectric, you can install it in different ways, from top to bottom or on
one side. The sensor is equipped with external and internal LED.
In case of alarm from one technology will only turn on the LED internal (short
flash for the microwave, turning on for 2 seconds to PIR). When PIR and MW go
in alarm (AND alarm) the external led turn ON for 4 seconds.
Other reports:
– Slow flashing alternating internal and external LED: the initialization
phase
– Short flash external LED: inhibition time, result of PERMITTED passage with
DIRECTION function ON (DIP 4 ON).
– Rapid blinking of ext.LED: the last 10 seconds of the inhibition time (DIP4
ON). NOTE: do not cover, partially or completely, the field of vision of
the detector
DIP-SWITCH | OFF | ON |
---|---|---|
DIP 5 | LED disable | LED enable |
DIP 1 | 1 pulse for alarm | 2 pulse for alarm |
DIP 2 | 2mt coverage | 3.5mt coverage |
DIP 4 | alarm from all direction | Alarm from one direction* (not IMQ certified) |
DIP 3 | 1 –> 2 alarm | 2 –> 1 alarm |
*To use the directional system optimally, you need to be inserted into the lens on the pyroelectric element separator (see figure) and install it paying attention to the direction selection (dip-swtch3)
INSTALLATION AND CONNECTION
Choose a suitable location, mount the sensor using the turrets tear to get the
tamper protection.
The cable can go from a tiny hole next to the terminals, or if the section is
very large, you can switch from the knock-out (see figure below) TAMPER:
TAMPER ANTIOPENING LINE – 400mA 40Vdc
ALARM: ALARM CONTACT 100 mA- 40V – 16 Q
SUPPLY: 13.8Vcc 28mA Max Fixed base rear slide the cable through the
holes selected, secure the board in its housing interlocking and fix the
cables into the appropriate terminals. Use the scew to fix the top.
In the figure at the end of manual, you can see different types of
installation, in the center of the window or on a side.
The drawings are for guidance only, so you should always test the sensor.
WARM UP AND OPERATION
At start up the sensor needs a warm up time, this time is about 40″.
During this time, the sensor it must not detect movimentation.
The WARM UP is represented from internal and external blink LEDs Once you have
finished this, you may perform the coverage tests.
SPECIFICATIONS/SPECIFICATIONS TECHNIQUE
Input Voltage| 9.5 to 15 Vdc
Current Drain (Stand-By)| 28 mA @ 13.8 Vdc
Coverage| 2 – 3,5 in
Angle| 165°
PlR| 2 elements
microwave receiver class| 2
Lens (beams and levels)| 6 beams on 1 levels
Alarm period| 4 sec.
Anti-opening| ✓
Alarm’s Contact| 100mA-40V-16 0
Tamper Switch| Max 400 mA – 40 Vdc
certified operating Temperature| From -10 °C to +55 °C
Protection| 10 V / m (20/1000 MHz)
Led WALK TEST (MW and P/R)| ✓
Housing| ABS
Dimensions| L 145 x H37 x P30 mm
EN 50131-2-4 Grade 2 Class 2
Installation must be carried out following the local installation norms by
qualified personnel.
The manufacturer refuses any responsibility when changes or unauthorized
repairs are made to the product/system.
is recommended to test the operation of the alarm product/system at least once
a month. Despite frequent testing and due to, but not limited to, any or all
of the following: tampering, electrical or communication disruption or
improper use, it possible for the product/system to fail to prevent burglary,
rubbery, fire or otherwise. A properly installed and maintained alarm system
can only reduce the risk that this happens.
L’installazione deve essere eseguita a regola d’arte da personale
specializzato.ll costruttore declina ogni responsabilita nel caso in cui il
prodotto venga manomesso da persone non autorizzate. Si raccomanda di
verificare il corretto funzionamento del sistema d’allarme almeno una volta al
mese, tuttavia un sistema di allarme elettronico affidabile non evita
intrusioni, rapine, incendi o altro, ma si limita a diminuire il rischio che
tali situazioni si verifichino.