Product Information
Specifications
- Device size: 195 x 120 x 40 (mm)
Physical Description
The i16S-02P SIP Intercom is a compact device with the following
components:
- Panel with Speaker, SOS Key, MIC, and DSS Key
Interface Description
The rear case of the device contains various terminal blocks for connecting
different components:
- Ethernet interface: standard RJ45 interface, 10/100M adaptive, recommended to use Cat5 or Cat5e network cable
- Power interface: 12V/1A input
- Two groups of short-circuit input detection interfaces: for connecting switches, infrared probes, door magnets, vibration sensors, etc.
- Two groups of short-circuit output control interfaces: used to control electric locks, alarms, etc.
- Recording output interface: for mixing the device and far-end call sound. Consists of a recording signal line and a ground line.
- External active speaker interface: for connecting external active speakers for audio power amplification. Consists of an audio signal line and a ground line.
Installation Diagram
- Use the built-in screw tool to remove the surface shell of the device.
- Based on the installation dimensions, draw the mounting hole on the wall using an electric drill.
- Plug the white rubber into the wall and fix it with screws.
- Connect the power cord and network cable, then screw the surface shell back onto the device.
Searching Device
There are two methods to search for the device:
- Method 1: Download the iDoorPhone Network Scanner tool from http://download.fanvil.com/tool/iDoorPhoneNetworkScanner.exe. Open the tool and press the Refresh button to search for the device and find its IP address.
- Method 2: Long press the DSS key for 3 seconds (after power-on for 30 seconds), and when the speaker beeps rapidly, press the DSS key again quickly. The beeps will stop and the intercom will report its IP address by itself.
Fast Settings
- Step 1: Log in to the device page by entering its IP address in a web browser (e.g., http://192.168.1.128). The default username and password are admin.
- Step 2: Set SIP account parameters, including the SIP server address, port, username, password, and SIP user. Select Activate and click Apply to save the settings.
FAQ
-
Q: What is the default network configuration of the device?
A: The default setting is DHCP client enabled by default. To obtain the voice broadcast IP address, hold the DSS key for 3 seconds, then press the DSS key again. -
Q: What is the default static IP address and web port?
A: The default static IP address is 192.168.1.128 and the default web port is
Package Contents
Physical specification
Panel
Interface description
Open the rear case of the device, there is a row of terminal blocks for
connecting the power supply, electric lock control, etc. The connection is as
follows:
Serial number| Description| Wiring port description(example
above)
---|---|---
①| Ethernet interface: standard RJ45 interface, 10/100M adaptive, it is
recommended to use five or five types of network cable|
②| Power interface: 12V/1A input| Left positive, right grounded
③、⑤| Two groups of short-circuit input detection interfaces: for connecting
switches, infrared probes, door magnets, vibration sensors and other input
devices| Left IN, right OUT
④、⑥| Two groups of short-circuit output control interface: used to control
electric locks, alarms, etc.| Left (NC): Normally Close Contact Center (COM):
Common Contact Right (NO): Normally Open Contact
⑦| Recording output interface: Mix the device and the sound of the far-end
call. One is the recording signal line, and the other is the ground line (be
sure to ground the line, otherwise there will be noise)| Left grounded, right
recording output
⑧| External active speaker interface: external active speakers for audio power
amplification. One is the audio signal line, and the other is the ground line
(be sure to ground the line, otherwise there will be noise)| Left grounded,
right external active speaker
Installation Diagram
- Use built-in screw tool to remove the surface shell;
- Based installation dimensions, mounting hole in the wall to draw, use an electric drill holes lay;
- The white rubber plugged into the wall and the bottom fixed with screws to the wall;
- After connecting the power cord and network cable, screw the surface shell fixed.
Fanvil Technology Co., Ltd
Website: www.fanvil.com
E-Mail: sales@fanvil.com
support@fanvil.com
Tel: +86-755-2640-2199 Fax: +86-755-2640-2618
Add: 10/F Block A, Dualshine Global Science Innovation Center, Honglang
North 2nd Road, Bao’an District, Shenzhen, China
Searching device
There as shown below to search the device.
Methods 1:
Download address:
http://download.fanvil.com/tool/iDoorPhoneNetworkScanner.exe Open the
iDoorPhone Network Scanner. Press the Refresh button to search the device and
find the IP address.
Method 2:
Long press DSS key for 3 seconds(after power-on for 30 seconds), and when the
speaker beeps rapidly, press DSS key again quickly, the beeps stop ,the
intercom will report the IP address by itself.
Method 3:
In addition, device provides the device surface DSS key operation to switch IP
address acquisition mode: In the standby mode, long-press the DSS key for 3
seconds and the beep will last for 5 seconds. Within 5 seconds, press the DSS
key three times quickly to switch to the network mode.
- a. If it is in the mode of DHCP and doesn’t receive the IP address, switch it to the mode of static IP (192.168.1.128), broadcast the IP address after the successful switch.
- b. If it is in the mode of static IP address (192.168.1.128), switch it to the DHCP mode, broadcast the IP address after the successful switch.
- c. If it is in the mode of DHCP and obtain the IP address, the mode will not be switched and directly broadcast the IP.
Default Setting
Default DHCP Client| Enabled by default| Static IP address|
192.168.1.128
Voice broadcast IP address| Hold the DSS key for 3 seconds, then press
the DSS key again.| Default Web port| 80
Fast settings
Step 1: Log in to the device page
Use the web browser input IP (for example: http://192.168.1.128) access. The
default user and password are admin.
Step 2: Set SIP account
Set SIP server address, port, user name, password and SIP user with assigned
SIP account parameters. Select “Activate”, and then click [Apply] to save this
setting.
Step 3: Set the volume (if not connected can skip)
Intercom settings => Media Settings => Media Settings
Set the device volume size, as shown below, click [Apply].
- Speakerphone volume setting: set the speaker volume of normal calls.
- Handsfree Mic Gain: set the microphone volume of call.
Step 4: Set function key (if not connected can skip)
Set the function key as shown below for a quick start, click [Apply] to save
this settings.
- Type : Memory key
- Number 1 (Value): the function key will dial to this number 1
- Number 2 (Value 2): if number 1 is unavailable, it will be forwarded to number 2.
- Subtype: speed dial
- Line: working line
Step 5: Set the security function
1 set of short-circuit input and output settings, tamper alarm server
settings.