Panasonic XKQ Single Split Wall Mount Air Conditioner Instruction Manual
- June 15, 2024
- Panasonic
Table of Contents
- XKQ Single Split Wall Mount Air Conditioner
- Product Information
- Specifications
- Product Usage Instructions
- Installation Instructions
- Operating Instructions
- Refilling Refrigerant
- Contact Information
- Q: Can I use a different type of refrigerant?
- Q: How can I control my air conditioner remotely?
- Q: How does nanoeTM X technology work?
- Q: How does the Humidity Sensor optimize the sleeping
XKQ Single Split Wall Mount Air Conditioner
Product Information
Specifications
- Product: Residential Air Conditioners
- Model: AC-PHP-C-22
- Manufacturer: Panasonic
- Year: 2022/2023
Product Usage Instructions
Installation Instructions
Before installing the unit, please read the Installation
Instructions carefully. This will ensure proper installation and
prevent any damage or safety issues.
Operating Instructions
Before using the air conditioner, please read the Operating
Instructions. This will provide you with important information on
how to use the product effectively and safely.
Refilling Refrigerant
Do not add or replace refrigerant other than the specified type.
Using a different refrigerant can cause damage or deterioration in
safety. The manufacturer is not responsible for any issues that
arise from using other refrigerants.
Contact Information
If you have any questions or need assistance, you can contact
the Panasonic Customer Care Center:
-
Location: Ortigas Avenue Extension, Taytay, Rizal, 1920
Philippines -
Hotline: (02)8-706-7603
-
PLDT Toll Free: 1800-10-7262782
-
GLOBE Toll Free: 1800-82-934357
-
Email: pmpc_csdcic@ph.panasonic.com
-
SMS: TYPE Panasonicmessage and send to Globe/TM subscribers:
21584703, SMART, SUN, TNT subscribers: 225654703 -
Fax: (02)8-706-7612
-
Facebook: Panasonic Philippines
-
Official Website: https://www.panasonic.com/ph
FAQ
Q: Can I use a different type of refrigerant?
A: No, it is important to use the specified type of refrigerant.
Using a different refrigerant can cause damage or safety
issues.
Q: How can I control my air conditioner remotely?
A: You can use the Panasonic Comfort Cloud app to control your
air conditioning from your mobile devices. This allows you to turn
on features like nanoeTM X even when you are away from home and
schedule timers according to your needs.
Q: How does nanoeTM X technology work?
A: nanoeTM X technology effectively inhibits adhered and
airborne pollutants, reduces odors, and operates on low energy
consumption. It requires no maintenance and provides 24-hour active
air protection.
Q: How does the Humidity Sensor optimize the sleeping
environment?
A: The Humidity Sensor constantly monitors and adjusts relative
humidity levels to below 60% for an optimal sleeping environment.
This helps you enjoy better sleep with comfortable cooling.
RESIDENTIAL AIR CONDITIONERS 2022/2023
WAKE UP REFRESHED
MORNING
NOON
Scan here to learn more Product range
AWAY FROM HOME
Please read the Installation Instructions carefully before installing the
unit, and the Operating Instructions before using it. Specifications are
subject to change without prior notice. The contents of this catalogue are
accurate as of September 2022. Due to printing considerations, the actual
colours may vary slightly from those shown. All graphics are provided merely
for the purpose of illustrating a point.
Do not add or replace refrigerant other than the specified type. Manufacturer
is not responsible for damage or deterioration in safety due to usage of other
refrigerant.
Panasonic Customer Care Center
Ortigas Avenue Extension, Taytay, Rizal, 1920 Philippines Hotline :
(02)8-706-7603 PLDT Toll Free : 1800-10-7262782 GLOBE Toll Free :
1800-82-934357 Email : pmpc_csdcic@ph.panasonic.com SMS (Text only) : TYPE
Panasonic
Globe/TM subscribers : 21584703 SMART, SUN, TNT subscribers : 225654703 Fax :
(02)8-706-7612 Facebook : Panasonic Philippines Official Website :
https://www.panasonic.com/ph
Authorised Dealer
Panasonic Heating & Cooling Solutions
Global site : aircon.panasonic.com PRO Club : panasonicproclub.global
Panasonic HVAC Global
AC-PHP-C-22
PRECIOUS NIGHT’S SLEEP
NIGHT
EVENING
FAMILY EVENING MOMENTS
PREMIUM INVERTER
DELUXE INVERTER
ASC Approved: P062P110420PS
Comfort Cloud App
Air Purification
Hazardous Substances
Pollen
Mould
Odours
Allergens
Skin & Hair Bacteria & Viruses
Stay Safe Indoors with 24-Hour nanoeTM X Air Protection
nanoeTM X technology with the benefits of hydroxyl radicals effectively inhibits adhered and airborne pollutants, and reduces odours. nanoeTM X operates on low energy consumption and requires no maintenance so your family can stay safe indoors with 24-hour active air protection.
1 The nanoeTM X mode can be run independently from cooling mode, and needs to
be ON for the 24-hour air purification to function.
*Applicable to PREMIUM INVERTER and DELUXE INVERTER.
Learn more about nanoeTM X
Inhibits 5 Types of Pollutants
Deodorises Moisturises
Bacteria & Viruses
Mould
Allergens
Pollen Hazardous Substances
Odours
Skin & Hair
Smartify Your Air Conditioner Anytime, Anywhere with Panasonic Comfort Cloud
Panasonic Comfort Cloud lets you control your air conditioning from mobile
devices remotely. Turn on nanoeTM X when you are away from home, or schedule
the timer according to your lifestyle needs and monitor energy consumption
conveniently at your fingertips-letting you take control of single or multiple
air conditioning units wherever you are.
*For PREMIUM INVERTER (3.0HP), DELUXE INVERTER and STANDARD INVERTER (1.0HP – 2.5HP), you need accessory CZ-TACG1 connected to port CN-CNT. Built-in wireless LAN is only available for PREMIUM INVERTER (1.0HP – 2.5HP). Illustration of app screen may differ from actual screen appearance.
02
Air Conditioning
Humidity Sensor Optimises An Ideal Sleeping Environment
Panasonic’s new iAUTO-X with Humidity Sensor constantly monitors and adjusts
relative humidity levels to below 60% for an optimal sleeping environment, so
you can enjoy better sleep with comfortable cooling.
*Applicable to PREMIUM INVERTER (1.0HP – 2.5HP)
Learn more about iAUTO-X and Humidity Sensor
Airflow Efficiency for Optimum Panasonic’s air conditioning delivers cooling comfort by distributing cool air
Cooling in Every Corner
throughout an entire room to keep your home cool and comfortable all day long.
NEW
The improved new AEROWINGS gives long air distance as far as 15 meters by
incorporating two independently controlled flaps.
*Applicable to PREMIUM INVERTER (1.0HP – 2.5HP)
AEROWINGS concentrates cool air for further and faster airflow across the
room.
*Applicable to PREMIUM INVERTER (3.0HP), DELUXE INVERTER, STANDARD INVERTER (2.5HP) and STANDARD NON-INVERTER (2.0HP – 2.5HP).
Big bottom flap directs cooling and comforting air across the room.
*Applicable to STANDARD INVERTER (1.0HP – 2.0HP) and STANDARD NON-INVERTER (1.0HP – 1.5HP).
Powerful Cooling for Instant Cooling Comfort
By activating the POWERFUL’ mode or
iAUTO-X’ mode, the air conditioner will
run both the compressor and indoor fan at higher speed, so you get to enjoy
rapid cooling even on the hottest days.
*Applicable to PREMIUM INVERTER (1.0HP – 2.5HP)
UP TO
18 FASTER COOLING
*Applicable to DELUXE INVERTER and STANDARD INVERTER (1.0HP – 2.5HP).
03
Air Efficiency
Energy Efficient & Eco-Friendly Technologies
Panasonic’s energy saving technologies such as INVERTER technology, ECO Mode with Artificial Intelligence (A.I.), environment-friendly R32 refrigerants and high CSPF help you make smarter, greener choices for your lifestyle.
UP TO
20 %* ENERGY SAVING
Energy Saving
04
Save Energy with Panasonic Inverter Technology
Learn more about Inverter technology
Panasonic’s Inverter reduces power consumption by varying the speed of the compressor according to the temperature changes with the aim of minimising the temperature fluctuations so you can enjoy consistent cooling comfort while saving energy.
*Applicable to PREMIUM INVERTER, DELUXE INVERTER and STANDARD INVERTER.
Comfort
Intelligently Balances Energy Savings And Comfort
As every room is different, ECO Mode with Artificial Intelligence (A.I.)
Control efficiently cools a room based on the amount of heat load and air
conditioning capacity. It finds the perfect ECO balance between power
consumption and time taken to reach the desired temperature to maintain your
comfort with minimal energy waste.
*Applicable to PREMIUM INVERTER (1.0HP – 2.5HP), DELUXE INVERTER and STANDARD INVERTER (1.0HP – 2.5HP).
An Environment-Friendly Refrigerant
Panasonic air conditioners are equipped with the environmentally friendly R32 refrigerant which efficiently carries heat, leading to greater energy savings and cost-effectiveness with lower environmental impact.
HIGHER
COOLING CAPACITY
REDUCE
ENERGY COST
ECO
FRIENDLY
CSPF/Easy to Install & Service
Cooling Seasonal Performance Factor (CSPF)
Panasonic Air Conditioners not only achieved high EER for rated operations,
but also have a high Cooling Seasonal Performance Factor – a more realistic
energy efficiency measurement based on customer’s actual environment of use
over an entire year.
Benefits of Implementing CSPF
A More Realistic Measure Easy To Identify of Energy Efficiency Energy Savings Value
Reduce Reduce Environmental
Electricity Bills
Impact
The adoption of CSPF ratings will greatly benefit you. It provides a more realistic evaluation of `efficiency’ which will be useful to choose the most energy efficient air conditioner model, thereby allowing you to reduce your energy bills and environmental impact.
The Advantages of Seasonal Efficiency VS Rated Efficiency
Factor
Temperature
Nominal
Single point of temperature conditions, e.g. outdoor temperature 35°C for
cooling. In reality, outdoor temperatures continuously change.
Calculated based on full capacity. Hence, it is
Cooling Capacity difficult to justify the benefits of INVERTER
technology.
CSPF
Adopts several rating temperatures for cooling, reflecting actual performance
over an entire cooling season.
Integrates operations at partial load instead of full capacity. Benefits of
INVERTER can be easily identified.
Easy to Install & Service
Panasonic air conditioners are durable and designed to fit easily with any interior. Its uniquely designed structure enhances durability, yet conveniently eases installation and maintenance routines.
Fits Easily In Tight Spaces
One-Piece Front Grille
Built-In Support Holder
Modular Design
50mm
50
mm
The compact design allows the unit to fit in tight spaces with a minimum 50mm gap from ceiling and wall.
New design with an open concept front grille that pulls right out for easy opening and access.
A convenient support holder helps to hold the unit up, leaving both your hands free and making it easier for you to work.
Electronic and wiring components have been integrated and moved to one side for easy servicing.
*Applicable to PREMIUM INVERTER (1.0HP – 2.5HP), DELUXE INVERTER, STANDARD INVERTER (1.0HP – 2.5HP) and STANDARD NON-INVERTER.
05
Product Line-Up
WALL-MOUNTED PREMIUM
Single-Split Type
CS-XU9XKQ | CS-XU12XKQ
CS-XU18XKQ | CS-XU24XKQ
Wireless
(Standard)
Wireless
CZ-RD514C (Optional)
nanoe X Generator Mark 2
NEW
BUILT-IN
MODEL
Cooling Capacity EER CSPF Electrical Data Moisture Removal Air Circulation
Noise Level
Unit Dimensions Indoor (Outdoor)
Packaging Dimensions Indoor (Outdoor)
Net Weight Gross Weight Refrigerant Pipe Diameter
Pipe Extension
Power Supply
INDOOR UNIT OUTDOOR UNIT
(60Hz)
(min-max) (min-max) (min-max)
kW kJ/h kJ/hW
W/W
Voltage
V
Current
A
Power Input (min-max)
W
L/h (Pt/h)
Indoor Outdoor
m3/min (ft3/min) m3/min (ft3/min)
Indoor (H / L / Q-Lo)
dB (A)
Outdoor (H)
dB (A)
mm Height
inch
mm Width
inch
mm Depth
inch
mm Height
inch
mm Width
inch
mm Depth
inch
Indoor / Outdoor
kg (lb)
Indoor / Outdoor
kg (lb)
Liquid Side
mm (inch)
Gas Side
mm (inch)
Chargeless Pipe Length
m
Maximum Pipe Length
m
Maximum Elevation Length
m
Additional Refrigerant Gas*
g/m
CS-XU9XKQ
CU-XU9XKQ 2.55 (0.92-3.20) 9,180 (3,310-11,520) 14.34 (14.71-13.09)
5.81 (5)
230 3.1 640 (225-880) 1.6 (3.4) 11.8 (415) 27.6 (970) 38/26/19 47 295 (511)
11-5/8 (20-1/8) 870 (650) 34-9/32 (25-19/32) 229 (230) 9-1/32 (9-1/16) 283
(578) 11-5/32 (22-25/32) 952 (784) 37-1/2 (30-7/8) 374 (347) 14-3/4 (13-11/16)
10 (22) / 18 (40) 12 (26) / 20 (44) ø 6.35 (1/4) ø 9.52 (3/8) 7.5 20 15 10
Outdoor
CS-XU12XKQ
CU-XU12XKQ 3.50 (1.02-4.20) 12,600 (3,670-15,120) 14.00 (14.12-12.81)
6.53 (5)
230 4.1 900 (260-1,180) 2.0 (4.2) 12.5 (440) 30.9 (1,090) 40/28/19 48 295
(542) 11-5/8 (21-11/32) 870 (780) 34-9/32 (30-23/32) 229 (289)
9-1/32(11-13/32) 283 (603) 11-5/32 (23-3/4) 952 (891) 37-1/2 (35-3/32) 374
(396) 14-3/4 (15-19/32) 10 (22) / 23 (51) 12 (26) / 25 (55) ø 6.35 (1/4) ø
9.52 (3/8) 7.5 20 15 10 Outdoor
*When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
OUTDOOR UNIT
CS-XU18XKQ
CU-XU18XKQ 5.30 (1.10-6.21) 19,080 (3,960-22,360) 15.14 (15.84-13.15)
6.92 (5)
230 5.7 1,260 (250-1,700) 2.9 (6.1) 18.7 (660) 34.9 (1,230) 44/32/27 50 295
(619) 11-5/8 (24-3/8) 1,040 (824) 40-31/32 (32-15/32) 244 (299) 9-5/8
(11-25/32) 314 (680) 12-3/8 (26-25/32) 1,148 (958) 45-7/32 (37-23/32) 383
(416) 15-3/32 (16-13/32) 12 (26) / 30 (66) 14 (31) / 33 (73) ø 6.35 (1/4) ø
12.70 (1/2) 10.0 30 20 15 Outdoor
CS-XU24XKQ
CU-XU24XKQ 6.10 (1.12-7.18) 21,960 (4,030-25,850) 14.17 (16.12-12.61)
6.81 (5)
230 6.9 1,550 (250-2,050) 3.4 (7.2) 19.2 (680) 46.3 (1,635) 45/34/28 51 295
(695) 11-5/8 (27-3/8) 1,040 (875) 40-31/32 (34-15/32) 244 (320) 9-5/8 (12-5/8)
314 (761) 12-3/8 (29-31/32) 1,148 (1,049) 45-7/32 (41-5/16) 383 (460) 15-3/32
(18-1/8) 12 (26) / 39 (86) 14 (31) / 43 (95) ø 6.35 (1/4) ø 12.70 (1/2) 10.0
30 20 15 Outdoor
CU-XU9XKQ
CU-XU12XKQ
CU-XU18XKQ
CU-XU24XKQ
06
WALL-MOUNTED PREMIUM
Single-Split Type
Product Line-Up
CS-XU30VKQ
OFF/ON
MODE SLEEP QUIET
TEMP
FAN SPEED
AIR SWING
ON TIMER
OFF
SET CANCEL
AIR CONDITIONER
Wireless
(Standard)
Wireless
CZ-RD514C (Optional)
Network Adaptor
CZ-TACG1 (Optional)
nanoe X Generator Mark 1
MODEL
Cooling Capacity EER CSPF Electrical Data Moisture Removal Air Circulation
Noise Level
Unit Dimensions Indoor (Outdoor)
INDOOR UNIT OUTDOOR UNIT
(min-max) (min-max) (min-max)
Voltage Current Power Input (min-max)
Indoor Outdoor Indoor (H / L / Q-Lo) Outdoor (H) Height
Width
Depth
Height
Packaging Dimensions Indoor (Outdoor)
Width
Net Weight Gross Weight Refrigerant Pipe Diameter
Pipe Extension
Power Supply
Depth
Indoor / Outdoor Indoor / Outdoor Liquid Side Gas Side Chargeless Pipe Length
Maximum Pipe Length Maximum Elevation Length Additional Refrigerant Gas*
(60Hz)
kW kJ/h kJ/hW W/W
V A W L/h (Pt/h) m3/min (ft3/min) m3/min (ft3/min) dB (A) dB (A) mm inch mm
inch mm inch mm inch mm inch mm inch kg (lb) kg (lb) mm (inch) mm (inch) m m m
g/m
*When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
OUTDOOR UNIT
CS-XU30VKQ
CU-XU30VKQ 8.20 (1.15-10.00) 29,520 (4,140-36,000) 12.83 (11.83-11.25)
5.70 (5)
230 11.0 2,300 (350-3,200) 4.8 (10.1) 21.3 (750) 50.2 (1,770) 47/37/34 53 302
(795) 11-29/32 (31-5/16) 1,120 (875) 44-1/8 (34-15/32) 241 (320) 9-1/2
(12-5/8) 287 (899) 11-5/16 (35-13/32) 1,190 (1,049) 46-7/8 (41-5/16) 378 (485)
14-29/32 (19-1/8) 13 (29) / 55 (121) 15 (33) / 60 (132) ø 6.35 (1/4) ø 15.88
(5/8) 10.0 30 20 25 Outdoor
CU-XU30VKQ
07
Product Line-Up
WALL-MOUNTED DELUXE
Single-Split Type
CS-XPU9WKQ | CS-XPU12WKQ | CS-XPU18WKQ
CS-XPU24XKQ
Wireless Wireless Wired Network Adaptor
(Standard) (Standard) CZ-RD514C
CZ-TACG1
(CS-XPU9/12/18WKQ) (CS-XPU24XKQ) (Optional)
(Optional)
nanoe X Generator Mark 1
MODEL
Cooling Capacity EER CSPF Electrical Data Moisture Removal Air Circulation
Noise Level
Unit Dimensions Indoor (Outdoor)
Packaging Dimensions Indoor (Outdoor)
Net Weight Gross Weight Refrigerant Pipe Diameter
Pipe Extension
Power Supply
INDOOR UNIT OUTDOOR UNIT
(60Hz)
(min-max)
kW
(min-max)
kJ/h
(min-max)
kJ/hW
W/W
Voltage
V
Current
A
Power Input (min-max)
W
L/h (Pt/h)
Indoor
m3/min (ft3/min)
Outdoor
m3/min (ft3/min)
Indoor (H / L / Q-Lo)
dB (A)
Outdoor (H)
dB (A)
mm Height
inch
mm Width
inch
mm Depth
inch
mm Height
inch
mm Width
inch
mm Depth
inch
Indoor / Outdoor
kg (lb)
Indoor / Outdoor
kg (lb)
Liquid Side
mm (inch)
Gas Side
mm (inch)
Chargeless Pipe Length
m
Maximum Pipe Length
m
Maximum Elevation Length
m
Additional Refrigerant Gas*
g/m
CS-XPU9WKQ
CU-XPU9WKQ 2.54 (0.84-3.10) 9,140 (3,020-11,160) 13.64 (13.73-12.61)
5.04 (5)
230 3.2 670 (220-885) 1.6 (3.4) 10.3 (365) 27.3 (960) 36/26/21 47 290 (511)
11-7/16 (20-1/8) 779 (650) 30-11/16 (25-19/32) 209 (230) 8-1/4 (9-1/16) 255
(578) 10-1/16 (22-25/32) 861 (784) 33-29/32 (30-7/8) 364 (347) 14-11/32
(13-11/16) 8 (18) / 18 (40) 9 (20) / 20 (44) ø 6.35 (1/4) ø 9.52 (3/8) 7.5 20
15 10 Outdoor
CS-XPU12WKQ
CU-XPU12WKQ 3.06 (1.02-3.80) 11,020 (3,670-13,680) 14.69 (14.98-11.69)
5.65 (5)
230 3.4 750 (245-1,170) 1.7 ( 3.6) 10.8 (380) 31.6 (1,120) 38/28/21 48 290
(542) 11-7/16 (21-11/32) 779 (780) 30-11/16 (30-23/32) 209 (289) 8-1/4
(11-13/32) 255 (603) 10-1/16 (23-3/4) 861 (891) 33-29/32 (35-3/32) 364 (396)
14-11/32 (15-19/32) 8 (18) / 23 (51) 9 (20) / 25 (55) ø 6.35 (1/4) ø 9.52
(3/8) 7.5 20 15 10 Outdoor
*When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
OUTDOOR UNIT
CS-XPU18WKQ
CU-XPU18WKQ 5.00 (1.10-5.40) 18,000 (3,960-19,440) 11.61 (13.66-10.80)
5.04 (5)
230 7.0 1,550 (290-1,800) 2.8 (5.9) 12.6 (445) 39.3 (1,390) 44/34/28 51 290
(619) 11-7/16 (24-3/8) 779 (824) 30-11/16 (32-15/32) 209 (299) 8-1/4
(11-25/32) 255 (680) 10-1/16 (26-25/32) 861 (958) 33-29/32 (37-23/32) 364
(416) 14-11/32 (16-13/32) 9 (20) / 29 (64) 10 (22) / 32 (71) ø 6.35 (1/4) ø
12.70 (1/2) 10.0 30 20 15 Outdoor
CS-XPU24XKQ
CU-XPU24XKQ 6.10 (1.12-7.18) 21,960 (4,030-25,850) 13.31 (16.12-12.61)
6.11 (5)
230 7.4 1,650 (250-2,050) 3.4 (7.2) 19.2 (680) 34.9 (1,230) 45/36/29 51 295
(619) 11-5/8 (24-3/8) 1,040 (824) 40-31/32 (32-15/32) 244 (299) 9-5/8
(11-25/32) 314 (680) 12-3/8 (26-25/32) 1,148 (958) 45-7/32 (37-23/32) 383
(416) 15-3/32 (16-13/32) 12 (26) / 31 (68) 14 (31) / 34 (75) ø 6.35 (1/4) ø
12.70 (1/2) 10.0 30 20 15 Outdoor
CU-XPU9WKQ
CU-XPU12WKQ
CU-XPU18WKQ
CU-XPU24XKQ
08
WALL-MOUNTED STANDARD
NEW
NEW
Single-Split Type
Product Line-Up
CS-QU9YKQ | CS-QU12YKQ | CS-QU18YKQ
CS-QU24YKQ
Wireless
(Standard)
Wired Network Adaptor
CZ-RD514C
CZ-TACG1
(Optional)
(Optional)
(CS-QU9/12/18YKQ)
(CS-QU24YKQ)
MODEL
Cooling Capacity EER CSPF Electrical Data Moisture Removal Air Circulation
Noise Level
Unit Dimensions Indoor (Outdoor)
Packaging Dimensions Indoor (Outdoor)
Net Weight Gross Weight Refrigerant Pipe Diameter
Pipe Extension
Power Supply
INDOOR UNIT OUTDOOR UNIT
(60Hz)
(min-max)
kW
(min-max)
kJ/h
(min-max)
kJ/hW
W/W
Voltage
V
Current
A
Power Input (min-max)
W
L/h (Pt/h)
Indoor
m3/min (ft3/min)
Outdoor
m3/min (ft3/min)
Indoor (H / L / Q-Lo)
dB (A)
Outdoor (H)
dB (A)
mm Height
inch
mm Width
inch
mm Depth
inch
mm Height
inch
mm Width
inch
mm Depth
inch
Indoor / Outdoor
kg (lb)
Indoor / Outdoor
kg (lb)
Liquid Side
mm (inch)
Gas Side
mm (inch)
Chargeless Pipe Length
m
Maximum Pipe Length
m
Maximum Elevation Length
m
Additional Refrigerant Gas*
g/m
CS-QU9YKQ
CU-QU9YKQ 2.54 (0.84-3.10) 9,140 (3,020-11,160) 13.64 (13.73-12.61)
5.04 (5)
230 3.2 670 (220-885) 1.6 (3.4) 10.3 (365) 27.3 (960) 36/26/21 47 290 (511)
11-7/16 (20-1/8) 779 (650) 30-11/16 (25-19/32) 209 (230) 8-1/4 (9-1/16) 255
(578) 10-1/16 (22-25/32) 861 (784) 33-29/32 (30-7/8) 364 (347) 14-11/32
(13-11/16) 8 (18) / 18 (40) 9 (20) / 20 (44) ø 6.35 (1/4) ø 9.52 (3/8) 7.5 20
15 10 Outdoor
CS-QU12YKQ
CU-QU12YKQ 3.06 (1.02-3.80) 11,020 (3,670-13,680) 14.69 (14.98-11.69)
5.65 (5)
230 3.4 750 (245-1,170) 1.7 ( 3.6) 10.8 (380) 31.6 (1,120) 38/28/21 48 290
(542) 11-7/16 (21-11/32) 779 (780) 30-11/16 (30-23/32) 209 (289) 8-1/4
(11-13/32) 255 (603) 10-1/16 (23-3/4) 861 (891) 33-29/32 (35-3/32) 364 (396)
14-11/32 (15-19/32) 8 (18) / 23 (51) 9 (20) / 25 (55) ø 6.35 (1/4) ø 9.52
(3/8) 7.5 20 15 10 Outdoor
*When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
OUTDOOR UNIT
CS-QU18YKQ
CU-QU18YKQ 5.00 (1.10-5.40) 18,000 (3,960-19,440) 11.61 (13.66-10.80)
5.04 (5)
230 7.0 1,550 (290-1,800) 2.8 (5.9) 12.6 (445) 39.3 (1,390) 44/34/28 51 290
(619) 11-7/16 (24-3/8) 779 (824) 30-11/16 (32-15/32) 209 (299) 8-1/4
(11-25/32) 255 (680) 10-1/16 (26-25/32) 861 (958) 33-29/32 (37-23/32) 364
(416) 14-11/32 (16-13/32) 9 (20) / 29 (64) 10 (22) / 32 (71) ø 6.35 (1/4) ø
12.70 (1/2) 10.0 30 20 15 Outdoor
CS-QU24YKQ
CU-QU24YKQ 6.10 (1.12-7.18) 21,960 (4,030-25,850) 13.31 (16.12-12.61)
6.11 (5)
230 7.4 1,650 (250-2,050) 3.4 (7.2) 19.2 (680) 34.9 (1,230) 45/36/29 51 295
(619) 11-5/8 (24-3/8) 1,040 (824) 40-31/32 (32-15/32) 244 (299) 9-5/8
(11-25/32) 314 (680) 12-3/8 (26-25/32) 1,148 (958) 45-7/32 (37-23/32) 383
(416) 15-3/32 (16-13/32) 12 (26) / 31 (68) 14 (31) / 34 (75) ø 6.35 (1/4) ø
12.70 (1/2) 10.0 30 20 15 Outdoor
CU-QU9YKQ
CU-QU12YKQ
CU-QU18YKQ
CU-QU24YKQ
09
Product Line-Up
WALL-MOUNTED STANDARD
Single-Split Type
CS-PU9WKQ | CS-PU12WKQ | CS-PU18WKQ
CS-PU24XKQ
Wireless
(Standard)
Wired Network Adaptor
CZ-RD514C
CZ-TACG1
(Optional)
(Optional)
(CS-PU9/12/18WKQ)
(CS-PU24XKQ)
MODEL
Cooling Capacity EER CSPF Electrical Data Moisture Removal Air Circulation
Noise Level
Unit Dimensions Indoor (Outdoor)
Packaging Dimensions Indoor (Outdoor)
Net Weight Gross Weight Refrigerant Pipe Diameter
Pipe Extension
Power Supply
INDOOR UNIT OUTDOOR UNIT
(60Hz)
(min-max)
kW
(min-max)
kJ/h
(min-max)
kJ/hW
W/W
Voltage
V
Current
A
Power Input (min-max)
W
L/h (Pt/h)
Indoor
m3/min (ft3/min)
Outdoor
m3/min (ft3/min)
Indoor (H / L / Q-Lo)
dB (A)
Outdoor (H)
dB (A)
mm Height
inch
mm Width
inch
mm Depth
inch
mm Height
inch
mm Width
inch
mm Depth
inch
Indoor / Outdoor
kg (lb)
Indoor / Outdoor
kg (lb)
Liquid Side
mm (inch)
Gas Side
mm (inch)
Chargeless Pipe Length
m
Maximum Pipe Length
m
Maximum Elevation Length
m
Additional Refrigerant Gas*
g/m
CS-PU9WKQ
CU-PU9WKQ 2.54 (0.84-3.10) 9,140 (3,020-11,160) 13.64 (13.73-12.61)
5.04 (5)
230 3.2 670 (220-885) 1.6 (3.4) 10.3 (365) 27.3 (960) 36/26/21 47 290 (511)
11-7/16 (20-1/8) 779 (650) 30-11/16 (25-19/32) 209 (230) 8-1/4 (9-1/16) 255
(578) 10-1/16 (22-25/32) 861 (784) 33-29/32 (30-7/8) 364 (347) 14-11/32
(13-11/16) 8 (18) / 18 (40) 9 (20) / 20 (44) ø 6.35 (1/4) ø 9.52 (3/8) 7.5 20
15 10 Outdoor
CS-PU12WKQ
CU-PU12WKQ 3.06 (1.02-3.80) 11,020 (3,670-13,680) 14.69 (14.98-11.69)
5.65 (5)
230 3.4 750 (245-1,170) 1.7 (3.6) 10.8 (380) 31.6 (1,120) 38/28/21 48 290
(542) 11-7/16 (21-11/32) 779 (780) 30-11/16 (30-23/32) 209 (289) 8-1/4
(11-13/32) 255 (603) 10-1/16 (23-3/4) 861 (891) 33-29/32 (35-3/32) 364 (396)
14-11/32 (15-19/32) 8 (18) / 23 (51) 9 (20) / 25 (55) ø 6.35 (1/4) ø 9.52
(3/8) 7.5 20 15 10 Outdoor
*When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
OUTDOOR UNIT
CS-PU18WKQ
CU-PU18WKQ 5.00 (1.10-5.40) 18,000 (3,960-19,440) 11.61 (13.66-10.80)
5.04 (5)
230 7.0 1,550 (290-1,800) 2.8 (5.9) 12.6 (445) 39.3 (1,390) 44/34/28 51 290
(619) 11-7/16 (24-3/8) 779 (824) 30-11/16 (32-15/32) 209 (299) 8-1/4
(11-25/32) 255 (680) 10-1/16 (26-25/32) 861 (958) 33-29/32 (37-23/32) 364
(416) 14-11/32 (16-13/32) 9 (20) / 29 (64) 10 (22) / 32 (71) ø 6.35 (1/4) ø
12.70 (1/2) 10.0 30 20 15 Outdoor
CS-PU24XKQ
CU-PU24XKQ 6.10 (1.12-7.18) 21,960 (4,030-25,850) 13.31 (16.12-12.61)
6.11 (5)
230 7.4 1,650 (250-2,050) 3.4 (7.2) 19.2 (680) 34.9 (1,230) 45/36/29 51 295
(619) 11-5/8 (24-3/8) 1,040 (824) 40-31/32 (32-15/32) 244 (299) 9-5/8
(11-25/32) 314 (680) 12-3/8 (26-25/32) 1,148 (958) 45-7/32 (37-23/32) 383
(416) 15-3/32 (16-13/32) 12 (26) / 31 (68) 14 (31) / 34 (75) ø 6.35 (1/4) ø
12.70 (1/2) 10.0 30 20 15 Outdoor
CU-PU9WKQ
CU-PU12WKQ
CU-PU18WKQ
CU-PU24XKQ
10
WALL-MOUNTED STANDARD
Single-Split Type
Product Line-Up
CS-PU36WKQ
Wireless
(Standard)
MODEL
Cooling Capacity EER Electrical Data Moisture Removal Air Circulation Noise
Level
Unit Dimensions Indoor (Outdoor)
INDOOR UNIT OUTDOOR UNIT
(min-max) (min-max) (min-max) Voltage Current Power Input (min-max)
Indoor Outdoor Indoor (H / L / Q-Lo) Outdoor (H)
Height
Width
Depth
Height
Packaging Dimensions Indoor (Outdoor)
Width
Net Weight Gross Weight Refrigerant Pipe Diameter
Pipe Extension
Power Supply
Depth
Indoor / Outdoor Indoor / Outdoor Liquid Side Gas Side Chargeless Pipe Length
Maximum Pipe Length Maximum Elevation Length Additional Refrigerant Gas*
(60Hz)
kW kJ/h kJ/hW
V A W L/h (Pt/h) m3/min (ft3/min) m3/min (ft3/min) dB (A) dB (A) mm inch mm
inch mm inch mm inch mm inch mm inch kg (lb) kg (lb) mm (inch) mm (inch) m m m
g/m
*When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
OUTDOOR UNIT
CS-PU36WKQ
CU-PU36WKQ 10.0 (2.7-11.0) 36,000 (9,720-39,600) 10.8 (17.1-10.6)
230 15.0 3,330 (570-3,730) 4.4 (9.4) 24.0 (847) 82.2 (2,902) 49/39 57 295
(955) 11-5/8 (37-5/8) 1,160 (1,100) 45-11/16 (43-5/16) 255 (370) 10-1/16
(14-19/32) 375 (1,018) 14-25/32 (40-3/32) 1,250 (1,305) 49-7/32 (51-13/32) 331
(535) 13-1/16 (21-3/32) 14 (31) / 76 (168) 20 (44) / 85 (187) ø 6.35 (1/4) ø
15.88 (5/8) 10.0 30 20 25 Outdoor
CU-PU36WKQ
11
Product Line-Up
WALL-MOUNTED STANDARD NON-INVERTER Single-Split Type
CS-PN9XKQ | CS-PN12XKQ
CS-PN18XKQ | CS-PN24XKQ
Wireless
(Standard)
(CS-PN9/12XKQ)
(CS-PN18/24XKQ)
MODEL
Cooling Capacity EER CSPF Electrical Data Moisture Removal Air Circulation
Noise Level
Unit Dimensions Indoor (Outdoor)
Packaging Dimensions Indoor (Outdoor)
Net Weight Gross Weight Refrigerant Pipe Diameter
Pipe Extension
Power Supply
INDOOR UNIT OUTDOOR UNIT
(60Hz)
(min-max)
kW
(min-max)
kJ/h
(min-max)
kJ/hW
W/W
Voltage
V
Current
A
Power Input (min-max)
W
L/h (Pt/h)
Indoor
m3/min (ft3/min)
Outdoor
m3/min (ft3/min)
Indoor (H / L / Q-Lo)
dB (A)
Outdoor (H)
dB (A)
mm Height
inch
mm Width
inch
mm Depth
inch
mm Height
inch
mm Width
inch
mm Depth
inch
Indoor / Outdoor
kg (lb)
Indoor / Outdoor
kg (lb)
Liquid Side
mm (inch)
Gas Side
mm (inch)
Chargeless Pipe Length
m
Maximum Pipe Length
m
Maximum Elevation Length
m
Additional Refrigerant Gas*
g/m
CS-PN9XKQ
CU-PN9XKQ 2.67 9,610 11.2
3.30 (1)
230 3.8 860 1.6 (3.4) 10.4 (367) 29.2 (1,030) 36/26 49 290 (511) 11-7/16
(20-1/8) 779 (650) 30-11/16 (25-19/32) 209 (230) 8-1/4 (9-1/16) 255 (578)
10-1/16 (22-25/32) 861 (784) 33-29/32 (30-7/8) 364 (347) 14-11/32 (13-11/16) 8
(18) / 21 (46) 9 (20) / 23 (51) ø 6.35 (1/4) ø 9.52 (3/8) 7.5 20 15 10 Outdoor
CS-PN12XKQ
CU-PN12XKQ 3.55
12,780 11.5
3.40 (2)
230 4.9 1,110 2.1 (4.4) 11.5 (406) 33.6 (1,190) 40/29 50 290 (542) 11-7/16
(21-11/32) 779 (780) 30-11/16 (30-23/32) 209 (289) 8-1/4 (11-13/32) 255 (603)
10-1/16 (23-3/4) 861 (891) 33-29/32 (35-3/32) 364 (396) 14-11/32 (15-19/32) 8
(18) / 28 (62) 9 (20) / 30 (66) ø 6.35 (1/4) ø 12.70 (1/2) 7.5 20 15 10
Outdoor
*When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
OUTDOOR UNIT
CS-PN18XKQ
CU-PN18XKQ 5.25
18,900 11.2
3.30 (2)
230 7.4 1,690 2.9 (6.1) 17.9 (632) 36.9 (1,300) 43/39 54 295 (619) 11-5/8
(24-3/8) 1,040 (824) 40-31/32 (32-15/32) 244 (299) 9-5/8 (11-25/32) 314 (680)
12-3/8 (26-25/32) 1,148 (958) 45-7/32 (37-23/32) 383 (416) 15-3/32 (16-13/32)
12 (26) / 35 (77) 14 (31) / 38 (84) ø 6.35 (1/4) ø 12.70 (1/2) 7.5 30 20 15
Outdoor
CS-PN24XKQ
CU-PN24XKQ 6.80
24,480 11.4
3.37 (2)
230 9.6 2,140 3.9 (8.2) 20.5 (724) 52.5 (1,850) 47/42 55 295 (695) 11-5/8
(27-3/8) 1,040 (875) 40-31/32 (34-15/32) 244 (320) 9-5/8 (12-5/8) 314 (761)
12-3/8 (29-31/32) 1,148 (1,049) 45-7/32 (41-5/16) 383 (460) 15-3/32 (18-1/8)
12 (26) / 54 (119) 14 (31) / 58 (128) ø 6.35 (1/4) ø 15.88 (5/8) 7.5 30 20 25
Outdoor
CU-PN9XKQ
CU-PN12XKQ
CU-PN18XKQ
CU-PN24XKQ
12
Split Type Cooling Models
Features Comparison
WALL-MOUNTED
PREMIUM INVERTER
DELUXE INVERTER
STANDARD INVERTER
CS-XU9XKQ CS-XU12XKQ CS-XU18XKQ CS-XU24XKQ
CS-XU30VKQ
CS-XPU9WKQ CS-XPU12WKQ CS-XPU18WKQ CS-XPU24XKQ
CS-QU9YKQ CS-QU12YKQ CS-QU18YKQ CS-QU24YKQ
CS-PU9WKQ CS-PU12WKQ CS-PU18WKQ CS-PU24XKQ
STANDARD NON-INVERTER
CS-PN9XKQ CS-PN12XKQ CS-PN18XKQ CS-PN24XKQ
iAUTO-X Powerful Mode Humidity Sensor ECO Mode with A.I. Inverter Control
SLEEP SLEEP Quiet Mode Soft Dry Operation Mode Personal Airflow Creation
Airflow Direction Control (Up & Down) Manual Horizontal Airflow Direction
Control ECONAVI
C Temperature Wave
nanoeTM X nanoe-G Odour-Removing Function Removable, Washable Panel
(Mark 2)
24-Hour Dual ON & OFF Real Setting Timer 24-Hour ON & OFF Real Setting Timer LCD Wireless Remote Control Wireless LAN Remote Control For Internet Connection Wired Remote Control
(Built-in) (Optional)
Random Auto Restart (Random) (32 Restart Patterns)
Blue Fin Condenser Long Piping (Numbers indicate the maximum pipe length) Top-
Panel Maintenance Access
Self-Diagnostic Function
20m [XU9/12] 30m [XU18/24}
COMFORT
[XPU24] [XPU9/12/18] [XPU9/12/18]
(Mark 1)
CLEANER AIR
(Mark 1)
CONVENIENCE
(Optional) (Optional)
(Optional) (Optional)
RELIABILITY
30m
20m (XPU9/12)
30m (XPU18/24)
(Optional) (Optional)
20m (QU9/12) (PU9/12) 30m (QU18/24) (PU18/24)
20m (PN9/12) 30m (PN18/24)
13
Model Line-Up
Horse Power (HP)
Capacity (kJ/h)
WALL-MOUNTED
PREMIUM INVERTER
1.0HP
9,000
CS-XU9XKQ
[CU-XU9XKQ]
WALL-MOUNTED
PREMIUM INVERTER
WALL-MOUNTED
DELUXE INVERTER
WALL-MOUNTED
STANDARD INVERTER
CS-XPU9WKQ
[CU-XPU9WKQ ] NEW
CS-QU9YKQ
(CU-QU9YKQ)
WALL-MOUNTED
STANDARD INVERTER
CS-PU9WKQ
[CU-PU9WKQ]
WALL-MOUNTED
STANDARD INVERTER
WALL-MOUNTED
STANDARD NON-INVERTER
( ): Outdoor Unit 14
Cooling Models
CS-PN9XKQ
[CU-PN9XKQ]
1.5HP
12,000
CS-XU12XKQ
[CU-XU12XKQ]
2.0HP
18,000
CS-XU18XKQ
[CU-XU18XKQ]
2.5HP
24,000
CS-XU24XKQ
[CU-XU24XKQ ]
CS-XPU12WKQ
[CU-XPU12WKQ] NEW
CS-QU12YKQ
(CU-QU12YKQ)
CS-XPU18WKQ
[CU-XPU18WKQ] NEW
CS-QU18YKQ
(CU-QU18YKQ)
CS-XPU24XKQ
[CU-XPU24XKQ] NEW
CS-QU24YKQ
(CU-QU24YKQ)
CS-PU12WKQ
[CU-PU12WKQ]
CS-PU18WKQ
[CU-PU18WKQ]
CS-PU24XKQ
[CU-PU24XKQ]
CS-PN12XKQ
[CU-PN12XKQ]
CS-PN18XKQ
[CU-PN18XKQ]
CS-PN24XKQ
[CU-PN24XKQ]
3.0HP
30,000
CS-XU30VKQ
[CU-XU30VKQ]
4.0HP
36,000
Model Line-Up
Features
nanoe X Generator Mark 2
BUILT-IN
NEW
nanoe X Generator Mark 1
nanoe X Generator Mark 1
(CS-QU24YKQ)
(CS-QU9/12/18YKQ)
(CS-PU24XKQ)
(CS-PU9/12/18WKQ)
CS-PU36WKQ
[CU-PU36WKQ]
(CS-PN9/12XKQ) (CS-PN18/24XKQ)
15
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>