SYNDOME ATOM850-LED Line Interactive UPS User Manual
- June 6, 2024
- SYNDOME
Table of Contents
SYNDOME ATOM850-LED Line Interactive UPS
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS – This manual contains important instructions for models ATOM850-LED/ ATOM850i-LED/ ATOM850-LCD/ ATOM850i-LCD/ ATOM1200-LCD/ ATOM1500-LCD/ ATOM2200-LCD that should be followed during installation and maintenance of the UPS and batteries.
-
This product is specially designed for PCs and it is not recommended for use in any medical equipment, life-supporting system and other specific important equipment.
-
Do not plug household appliances such as hair dryers, microwave ovens or vacuum cleaners to UPS.
Do not attach a power strip or surge suppressor to the UPS. -
Do not plug the UPS into its own output.
-
Connection to any other type of receptacle other than a two-pole, three-wire grounded receptacle may result in shock hazard as well as violate local electrical codes.
-
To reduce the risk of overheating the UPS, do not cover the UPS´ cooling vents.
-
This unit is intended for installation in a controlled environment (temperature-controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is standing or running water or excessive humidity and do not use it in any of the following environments:
Any area with combustible gas, corrosive substance or heavy dust.
Any area with extraordinarily high or low temperature (above 40˚C or below 0˚C) and humidity of more than 90%.
Any area exposed to direct sunshine or near any heating apparatus.
Any area with serious vibrations.
Outdoor. -
The utility power outlet shall be near the equipment and easily accessible. In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS.
-
The internal short-circuiting of the UPS will lead to dangers such as electric shock or fire; therefore do not allow liquids or any foreign object to enter the UPS. No water containers (such as a water glass) or any other liquid-containing vessels shall be placed on the top of the UPS so as to avoid such dangers as electric shock.
-
Please do not use the UPS in excess of the rated load capacity.
-
Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
-
Risk of electric shock, do not attempt to disassemble the unit. No user-serviceable parts inside. Refer servicing to qualified service personnel.
-
If UPS is to be stored for a long time, it is recommended to recharge the batteries (by connecting the utility power to UPS, switch “ON”), once a month for 24 hours to avoid a full battery discharge.
-
In case smoke is found coming out from the device, please cut off the power supply quickly and contact the distributor.
-
The UPS contains one/two large-capacity batteries. So the shell shall not be opened, otherwise, such dangers as the electric shock will be caused. If any internal overhaul or replacement of the battery is required, please contact the distributor.
-
Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.
-
A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries:
Remove watches, rings, or other metal objects from the hand.
Use tools with insulated handles and wear rubber gloves and boots.
Do not lay tools or metal parts on top of batteries.
Disconnect charging source prior to connecting or disconnecting batteries terminals. -
When replacing batteries, replace with the same type and number of the sealed lead-acid batteries.
-
The maximum ambient temperature rating is 40°C.
-
Do not dispose of batteries or batteries in a fire. The battery may explode.
-
Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic.
-
ATOM Φ on the rating label stands for phase symbol.
-
This pluggable type A equipment with the battery already installed by the supplier operator is installable and may be operated by laymen.
-
During the installation of this equipment, it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3.5mA.
-
Attention, hazardous through electric shock. Also with the disconnection of this unit from the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary.
-
In the event that there is fire occurring in the vicinity, please use dry-powder extinguishers. The use of liquid extinguishers may give rise to the danger of electric shock.
This product complies with the safety and environmental regulations in
EU.
If the time arises to throw away your product, please recycle all the
components possible. Batteries and rechargeable batteries are not to be
disposed of in your domestic waste! Please recycle them at your local
recycling point. Together we can help to protect the environment.
Introduction
ATOM series is an intelligent and compact line interactive UPS (Uninterruptable Power Supply) which is designed to protect your personal computer or sensitive electronic types of equipment from all forms of power interference, including complete power failures. It is equipped with many features that allow any attached equipment to operate longer and more reliable.
Description of Features
- Easy to use and install utilized microprocessor control to maximize the reliability and efficiency
- LED or LCD display interface
- Equipped with built-in boost and buck AVR function
- DC Cold start function
- Auto restart while AC recovery.
- Provides AC Overload protection
- RJ11/RJ45 (in/out) LAN/Modem/Phone line protection
Package Contents
You should have received the following items inside of the package:
Product Overview
Front Panel—LCD
Display
Load level definition:
Battery capacity definition:
1BAT model battery definition:
2BAT model battery definition:
When over load, the mark will flicker every 1second.
When battery low, the mark will flicker every 1second.
Front Panel-LED
Rear Panel for LCD & LED:
Installation and Initial Startup
WARNINGS
Before installation, please inspect the unit. Be sure that nothing is
damaged.
Placement & Storage Conditions
Install the UPS in a protected area that is free of excessive dust and has
adequate air flow around the unit, and is free from excessive dust, corrosive
fumes and conductive contaminants. Please place the UPS away from other units
at least 20 cm to avoid interference. Do NOT operate the UPS where the
temperature exceeds 0-40° C and the humidity is over 0-90 % RH.
Connect to Utility and Charge
Plug in the AC input cord to the 2-pole, 3-wire grounded wall outlet. For the
best results, we suggest charging the battery at least 6 hours with no load
(no electrical devices such as computers, monitors, etc.) connected before
initial use. The unit charges its battery while connecting to the utility.
Connect the Loads
Plug in the loads to output receptacles on the rear panel of the UPS. Simply
turn on the power switch of UPS unit, and devices connected to the UPS will be
protected by UPS unit.
WARNINGS :
Do not attach a power strip or surge suppressor to the UPS
Connect LAN cable, Modem or Phone line for Surge Protection
Connect for example a single modem or phone line into surge-protected “IN”
outlet on the back panel of the UPS unit. Connect from “OUT” outlet to the
computer with another phone line cable.
Connect USB Cable(For LCD models only)
To monitor the UPS status, such as unattended UPS shutdown and start-up, by
using bundled software, please connect the UPS and PC with USB cable included.
WARNINGS:
NEVER connect a laser printer or scanner to the UPS unit, because in-rush
current generated by motor’s devices may cause the damage of the unit.
Turn On/Off the Unit
Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by
pressing again the power switch.
Functions & Operation
-
DC Start Function
DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged. Just simply press the power switch to turn on the UPS. -
AVR (Automatic Voltage Regulation)
If the quality of the incoming mains is poor, the AVR boosts a low incoming voltage or reduces a high one. The load receives a voltage within the normal range. -
Auto restart while AC recovery
-
Audio Indicator
Audible Alarm | Situation |
---|---|
Sounding every 10 seconds | Battery Mode |
Sounding every 1 second | Battery Low |
Sounding every 0.5 seconds | Overload |
Sounding every 2 seconds | Battery replace |
continuous sounding | Faulty |
Software Installation on your PC
Connected by USB to a PC or notebook, the Software enables communication
between the UPS and the computer. The UPS software monitors the status of the
UPS, shuts down the system before the UPS is exhausted and can remotely
observe the UPS via the Network (enabling users to manage their system more
effectively). Upon AC failure or UPS battery low, UPS takes all necessary
actions without intervention from the system administrator. In addition to
automatic file saving and system shut-down functions, it can also send warning
messages via pager, e-mail etc.
- Use the bundled CD and follow the on-screen instructions to install the software WinPower.
- Enter the following serial No. to install software: 511C1-01220-0100-478DF2A
- After the software is successfully installed, the communication with UPS has been established and a green ATOM will appear in the system tray.
- Double-click the ATOM to use the monitor software (as above).
- You can schedule UPS shutdown/start-up and monitor UPS status through PC.
- Detail instructions please refer to the e-manual in the software.
WARNINGS:
Check www.winpower.com/winpower.html from time
to time to get the latest version of monitoring software.
Maintenance
-
General
The UPS is virtually maintenance free: take care of proper environmental conditions and keep air inlets-outlets free of dust. -
Fuses
If the AC input fuse is defect, be sure it is replaced by a compatible fuse from the same make and type.
Never short circuit batteries. When working with batteries, remove watches, rings and other metal objects, and only use insulated tools. -
Batteries
Read all safety rules before replacing the battery.
When replacing the batteries, use batteries with exactly same specifications.
Trouble Shooting
Symptom | Possible Cause | Remedy |
---|
No LED display on the front panel.
| 1. Battery weak.| 1. Charge battery up to 8 hours.
2. Battery defect.| 2. Replace with the same type of battery.
3. Power switch is not pressed.| 3. Press the power switch again.
Alarm buzzer beeps continuously when AC supply is normal.| ****
Overload of the UPS.
| Verify that the load matches the UPS capability specified in the specs.
When power failure, back-up time is shorten.
| 1. Overload of the UPS.| 1. Remove some non-critical load.
2. Battery voltage is too low.| 2. Charge battery 8 hours or more.
3. Battery defect due to high temperature operation environment, or improper
operation to battery.| 3. Replace with the same type of battery.
Mains normal but LED is flashing.| Power cord is loose.| Reconnect the power
cord properly.
If any abnormal situations occur that are not listed above, please call service people immediately.