SPECIFICATIONS

Dimension (inchs): 59.84 × 31.1 × 39.37″
Material: Acrylic
To Overflow Depth: 29.52″
Weight: 236 lbs.
Full Water Volume is 65-75 gallons
(Est. with person in tub)
Faucet Fill Rate @ 80 PSI: 14.4GPM
Drain Time: 2-3 minutes depending on home plumbing ※ 2″ PVC Pipe
RATING: 110-120V, 1.2HP, 8.1A, 60Hz

DIAGRAM & FEATURES

  • A. Internal Grab Bar.
  • B. Two Handle Roman Faucet. Utilize the left hand lever to allow hot water to flow. Utilize the right hand lever to allow cold water to flow. The tub filler is located between the hot and cold lever handles to allow the complete flow of water.
  • C. Ten Hydro Massage Jets. Use to massage lumbar area of back, feet and legs. Activated when using the water pump. Adjust utilizing the Water Mixture Control (F).
  • D. 2″ Horizontal Drain. To drain the tub. The drain must be closed to fill the tub. Check and clear debris as needed (i.e. hair) from over flow drain. Turn the drain operator to open and close the drain. This is where excess water will flow when the bathing unit is over filled. Never fill bathing unit above the drain knob.
  • E. Pillow.
  • F. Back Hydro Massage Jets. Positioned to massage back.
  • G. Water Mixture Control. Increases or decreases the volume of air to Hydro Massage Jets (C) which intensifies or decreases the massaging action.
  • H. Hydro Jets Push Button. Turns the Hydro Massage Jets on and off.
  • I. Door lever. Contrel the door locked or unlocked.
  • J. Water Pump. the water intake feeds water into the water pump when utilizing the water jets. When the water pump is in use, there is suction on this return that should not be obstructed. Be careful of washcloths, body sponges, etc. This should be checked and cleaned of hair and debris as needed.
  • K. Suction Cover. Water pump inlet water source. There must be no foreign objects (such as towels) placed around the suction cover.

GT-6037W LH Drawing

SAFETY INFORMATION

Please read and understand this entire manual before attempting to assemble, operate, or install the product. Improper installation, operation and maintenance will cause the damage to the products and charge you extra repairing free.
– Thank you for choosing our walk-in bathtub series;
– We provide limited warranty after-sale service, please fill warranty registration form accurately (Warranty does not cover damage to bath caused in transit or installation);

In order to install the product correctly and safely by the installer, and maintain this product correctly and safely, please pay attention to the warning sign as below.

⚠ This symbol indicates that errant handling could result in personal injury.
? This symbol indicates that errant handling could result in personal property loss.

These instructions contain important care, cleaning, and warranty information. Please leave these instructions to customers for future reference. Uncrate and inspect bath for damage. Leave all materials in carton prior to fixture construction to prevent damage or component from missing.

PREPARATION

Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list and hardware contents list.
If any part is missing or damaged, do not attempt to assemble the product. Contact customer service for replacement parts.
Estimated Assembly Time: 240 minutes
Tools Required for Assembly: Adjustable Wrench, Silicone Sealant, Allen Wrench, Scissors, Level, Helpful Tools (not included): Basin Wrench, 3/4″ to 1/2″ Adapter, Hubless Coupling, Tile Flange Kit,2” PVC Hose, 2” PVC Elbow, P-Trap

PACKAGE CONTENTS

UNPACKING THE UNIT

  1. Inspect the carton for damage: Take a picture if possible. CAREFULLY RECORD ALL PERCEIVED DAMAGE and call us.

  2. DO NOT LIFT THE BATHTUB BY THE PLUMBING. Doing so will result in leaks, for which the installer is responsible. All Walk-In Bathtubs are water tested before they leave our factory and the bathtub you have purchased has passed inspection.

  3. Inspect the unit for damage even if there is no carton damage. All product damage must be reported within 72hrs of receipt from walk-in bathtubs.
    Once the unit is installed, surface damages will be assumed to be installation-related if not reported prior to installation. Installers are also responsible for damage that occurs once the unit is placed in its location.

  4. Inspect the plumbing for any fittings that may have loosened in transit.

  5. Read the following instructions completely before installing this product. If the home-owner or installer has any questions, please call us.

  6. You must follow all the instructions in this manual.

  7. After opening the box, please immediately dispose of unneeded packaging. Or it may cause the personal injury by the nails, cardboard or sealing straps. In addition, please do not let children play with the packing material or it can cause personal injury.

FAILURE TO READ AND COMPLY WITH ALL INSTRUCTIONS CAN RESULT IN PRODUCT DAMAGE OR INJURY TO BOTH INSTALLER AND HOMEOWNER. IT WILL ALSO RESULT IN ASSUMPTION OF ALL LIABILITY BY SAID INSTALLER.

RESPONSIBILITIES OF THE INSTALLER

The installer MUST INSPECT AND WATER TEST THE PRODUCT PRIOR TO INSTALLATION TO ENSURE THE UNIT IS FREE OF DEFECT AND / OR DAMAGE. In the event of a problem. the unit must not be installed. If the packaging or product has been damaged, please call immediately us.

This product has been listed by INTERTEK / ETL and IAPMO / C UPC. The product has been tested and complies with the following standards and guidelines: IAPMO /C UPC, UL-1795, ANSI Z-124.1.2, ASME A 112.19.7, ASME A 112.19.15 & CSA B-45. The installer is responsible for compliance to state and local codes.

This product is designed to be installed by a licensed tradesperson. Licensed plumbers and electricians should be employed to insure proper installation. Installer assumes all liabilities for installation procedures.

Although we have taken reasonable precautions to ensure that the drain is suitable for residential plumbing, it is the responsibility of the installer to ensure that the plumbing is acceptable for use of the drain. We do not accept responsibility for damage arising from use of the drain.

Only accessories authorized by manufacturer should be used with this product.
⚠ WARNING! ALL INSTRUCTIONS LISTED IN THIS MANUAL SHOULD BE READ AND FOLLOWED CAREFULLY. ALL PRECAUTIONS PERTAINING TO RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS MUST BE UNDERSTOOD AND EXPLAINED TO OWNER.

SAFETY INSTRUCTIONS

OPERATIONAL:

  1. Do not permit children to use unit unless they are closely supervised at all time. Supervision is also required when the bath is used by an elderly or handicapped individual.
  2. Use this unit only for its intended use as described in this manual. Only use attachments recommended by the manufacturer.
  3. Do not insert any object into any opening. Do not operate electrical appliances while in or within 5 feet of the bath.
  4. Do not operate this unit without the guard over the suction fitting. Long hair must be kept away from the suction screen to avoid entrapment. If entrapment occurs, immediately turn unit off.
  5. Do not start pump before unit is filled with water 2” above jets – this will void the warranty.
  6. Water level should not exceed the lowest edge of the overflow or controls.
  7. The water in a whirlpool should not exceed 40°C (104°F). Water temperatures between 38°C (100°F) and 40°C (104°F) are typically considered safe for a healthy adult. Prolonged immersions in hot water may produce hyperthermia. The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness and fainting, which can be fatal. Lower temperatures are recommended for extended use (exceeding 10-15 minutes) for young children.
  8. Exposure to very hot water has the potential to cause fetal damage during the early months of pregnancy. Pregnant, or possibly pregnant women should limit water temperature to 38°C (100°F). Consult a physician before using.
  9. Persons using medication should consult a physician before using a whirlpool since medication may induce drowsiness, affect heart rate, blood pressure and circulation. The use of alcohol, drugs or medication before or during whirlpool use may lead to unconsciousness with the possibility of drowning.
  10. Persons suffering from obesity or with a medical history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using a whirlpool.

ELECTRICAL:

  1. This unit must be connected to a supply circuit that is protected by a ground-fault-circuit-interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button.
    Power should be restored. If the GFCI fails to operate in this manner, there is a ground current flowing indicating the possibility of an electric shock.
    Do not use this unit. Disconnect the unit and have the problem corrected by a qualified service representative before using.

  2. Disconnect power before servicing.

  3. Whirlpool Pump Connections Only:
    3.1. A green colored terminal (or wire connector marked “G”, “GR”, “Ground” or “Grounding”) is provided within the terminal compartment. To reduce the risk of electric shock, connect this terminal or connector to the grounding terminal of your electric service or supply panel with a continuous green insulated copper wire equivalent in size to the circuit conductors supplying this equipment.
    3.2. A pressure ground connector is provided on the exterior of the terminal box within this unit to permit connection of a No. 8 AWG (8.4mm²) solid copper bonding conductor between this unit and all other electrical equipment and exposed metal in the vicinity, as needed to comply with state and local requirements.

  4. Install to permit access for servicing (for built-in and custom units).

  5. Installer / Owner bears all responsibility to comply with all state and local codes when installing this product.

INSTALL YOUR FAUCET KIT

TESTING YOUR WALK-IN BATHTUB BEFORE INSTALLATION

All bathtubs are 100% water tested at the factory and have passed inspection. Transportation and mishandling may loosen fittings and cause leaks. It is therefore necessary to test the bathtub while there is access to all sides of the bath.

  1. This unit should be both static and operationally tested with water. It is best to test the unit outside by filling with a garden hose.
    1.1. Place the bathtub on a completely flat surface in an area where it may be drained after testing.
    1.2. Install th e door lever on the door that can be found inside the bathtub part’s box .
    1.3. Seal the drain hole (Use the drain plug in the part’s box) and fill the bathtub with approximately 8″ of water.
    1.4. Verify drain plunger opens and closes freely.
    1.5. Fill the bathtub to top of seat level.
    1.6. Repeat 1.4.
    1.7. Fill the bathtub with water to the overflow.
    1.8. Repeat 1.4.

  2. Allow the water to stand in bathtub for 2 hours and then inspect all plumbing and seals for leaks.

  3. Using appropriately rated three-prong extension cords, plugged in to separate outlets, operate the whirlpool pump for another 30 minutes and inspect for leaks again.

  4. Inspect the unions around the whirlpool pump. The whirlpool pump is connected by unions. If a leak persists at a union after tightening, it may have been over-tightened or might have a displaced O-ring. Disassemble it and make sure the O-ring was seated properly.

  5. Ensure that all jets are open and working, some hydro jets are adjustable for both flow rate and direction of flow. The jet flow rate is adjusted by turning either the water mixture control clockwise or counterclockwise. Some hydro jets are not adjustable direction of flow where located at the seat back.

  6. If there are leaks, mark the spot(s), drain and repair with GE Silicone Sealer (fiber glass to PVC) or PVC cement (PVC to PVC). Repeat test when dry.

⚠ Check to ensure that your installation will conform to all applicable codes and secure necessary permits. All electrical and plumbing connections should be made by qualified electricians and plumbers.
? Failure to perform these tests before installation will make the installer liable for future repair costs.

PREPARTION BEFORE INSTALLATION

Make sure place you install the bathtub is strong enough to bear the total weight of bathtub, maximum water volume and the user.
Waterproofing process must be made in the place of bathtub installed, or down stair will get damaged if water leaks.
The installed place must equip with water supply, power supply and drainage:
This product uses universal home power.
Please reserve the drainage hole ≥ 2″, make sure the drainage pipes accord with the drain kit.
User need to reserve the connector of 1/2″ external thread cold/hot water hoses, which outstand the wall 1-1/2″. It is suggested to install a valve in each pipe, the location of installed should be designed by user, which is convenient for maintaining.
As each bathroom is slightly different, please place the bathtub according to the actual situation, the following illustration as reference layout.

⚠ WARNING:
The safe distance between the power supply and the water supply is not less than 2″. And the power supply is located above the water supply.
Parts containing live parts must be inaccessible to a person in the bath.
Earthed appliances must be permanently connected to fixed wiring.
Parts incorporating electrical components, except remote control devices, must be located or fixe so that they cannot fall into the bath.
Please do not use other power, except specified power. Or it may cause fire or electric shock.
Do not use the broken power supply, power plug or the loose socket. Or it may cause fire or electric shock.
Do not modify the power supply cord, use it with an extension cord or combine it with other equipment using multiple plugs. Doing so could lead to chocks, overheating or fire.
The power need to connect to terminal box, and it must be operated by a qualified electrician.

INSTALLATION INSTRUCTIONS

  • A. Flush all water supply lines of debris
    Before connect bathtub water inlet pipe, first open water valve for a period of time to clean the debris from the pipe. Make sure that the debris will not enter the bathtub pipe. So that we can effectively extend the life of the fitting.

  • B. Remove access panel
    Temporarily remove all access panels. Part of the process of the installer can be more convenient to install through the access window.

  • C. Leveling the adjustable feet
    1. Feet are extended for shipping purposes to provide clearance and protection of the front of tub. The tub should be reset by installer to proper height required to level the tub.
    2. Raise the four center feet so that tub rests only on the four corner feet.
    3. Raise the corner feet to lower tub to desired height and level tub in both directions.
    4. Verify bathtub level and lock the four corner feet in position.
    5. Lower the four center feet so they firmly contact the floor and tighten in place.
    6. When finished, tighten the nuts of the adjustable feet to fix the height of the bathtub.

  • D. Connect the water supply
    For ease of use, our bathtub is equipped with stainless steel cold and hot hoses (connector 1/2″, Packaged with faucet kit).
    Please connect the cold and hot water hoses to the bathroom’s cold and hot water hoses accordingly.
    Note: The specification of the water inlet hose is 1/2″. If there is no reserved 1/2″ water inlet connector, please use a 3/4″ to 1/2″ adapter shown (not included).

  • E. Connect the drain kit
    The bathtub has a drain assembly installed and water tested. Follow the illustration to connect the drain assembly to the house’s sanitation system.

  • F. Connect the electricity
    WARNING: Refer to Section 680 of National Electrical Code. When using electrical products, basic precautions should always be followed, including the following:
    1. DANGER: RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a ground-fault circuit-interrupter.
    2. Grounding is required. The unit should be installed by a qualified installation technician.
    3. Building materials and wiring should be routed away from the pump body or other heat-producing components of the unit.
    WARNING:
    External circuitry need to equip with high sensitive and fast type leakage protection switch. (Induced current rating below 15mA, trip time should less than 0.1 second, rated current is about 15A.)
    The bathtub must be connected to the ground. Power outlet must be sealed well. Make sure the surface of each wire is intact.
    The product should be installed the grounding and electric leakage switch by a qualified licensed electrician.

  • G. Pillow
    Put the pillow on the bathtub headrest and press the suction pads in position tightly.

  • H. Water test
    After completing the above installation steps, it is time to perform the post installation water test. This will detect water leaks caused by improper operation of the installation process at an early stage and avoid losses:
    1. Fill the bathtub with water at least 2” above the highest jets.
    2. Turn on the water jets for 30 minutes. Then inspect the door seals for leaks.
    3. Verify drain plunger opens and closes freely.
    4. Inspect underneath tub drain hose for leaks.
    5. Run the faucet and hand shower and inspect for any leaks at connection locations.

  • I. Silicone seal & fixed
    Bathtubs installed in an alcove installation require a raised flange to prevent water from seeping past the tub and into the wall. The bathtub should be installed with a tile flange kit (Not Supplied). The flange kit is a long plastic strip that fits onto the rim of the tub to provide the leak protection needed.
    The tile flange should be installed on the tub before it is placed in the alcove.
    Install the tile flange along all sides of the tub where the wall will be. Measure to fit and miter cut the flange corners. The flange should be attached to the tub with a construction adhesive. Once the tub is in place to be installed and flange kit mounted, fasten the flange to studs using fasteners.
    ? CAUTION:
    Never attempt to nail or screw through the bathtub as this will result in product failure and will void the warranty.

  • J. Clean after installation is complete
    When cleaning after installation, do not use abrasive cleaning implements to avoid damaging and tarnishing the surface of the tub. Clean the surface of the tub with warm water and a non-aggressive liquid cleaner.
    Difficult-to-remove stains can be cleaned with alcohol. The plaster can be scraped off with a thin wooden knife. For residual grout, use a damp cloth with liquid laundry detergent.
    ? CAUTION:
    Under no circumstances use wire brushes, metal sponges, steel wool or scouring pads on any part of the tub, or solvents that contain petroleum distillates such as acetone, benzene or abrasive cleanser on any part of the tub. Use caution with ammonia and chlorine-based cleaners on metallic trim components. The metal surface is a plated finish and these types of cleaners can erode or discolour the finish.
    CLEANING THE BATHTUB WITH THE ABOVE ITEMS WILL VOID THE WARRANTY!!!

OPERATING INSTRUCTION

Door Operation
1. Close the door:
1.1. Close the door.
1.2. Place the door lever in closed position.
2. Open the door:
2.1. Pull out door lock and keep it pulled out.
2.2. Place the door lever in opened position.
2.3. release the door lock and open door.

? CAUTION:
WHEN NOT IN OPERATION KEEP DOOR UNLOCKED TO MAINTAIN GASKET SHAPE. IF THE DOOR IS LEFT IN THE CLOSED POSITION FOR LONG PERIODS OF TIME THE DOOR GASKET WILL LOSE ITS FLEXIBILIGY AND WILL NOT RETAIN ITS SEALING CAPABILITY.

Two Handle Roman Faucet
A: Hot water lever. Controls the flow of hot water.
B: Fill Spout with diverter. The hot and cold water levers mix the desired water temperature which flows into the bathtub through the fill spout. When water is flowing through the spout lift the diverter up to divert water to handheld shower.
C: Cold water lever. Controls the flow of cold water.
D: Handheld shower. By turning the dial, you can switch between 6 water spray modes

CAUTION:
When you first use the bathtub every day, be certain tub drain is open as first water coming from spout may be too cold or too hot.
Carefully test water temperature by slowly moving hand into water stream.

Horizontal Drain
Rotate the operator clockwise to open the drain.
Rotate the operator anticlockwise to close the drain.
When the water is over the maximum water level, the excess water will drain by overflow.

Water Jet Hydrotherapy System
After entering your bathing and closing the door, turn the drain shut counterclockwise to close the drain. Fill the bathtub with water above the highest jet before activating the whirlpool pump.
The water jets are operated by the On/Off push button. First push turns the jets on and second push turns the jets off. Do not push the buttons repeatedly or rapidly.
The Water Mixture Control is used to add or eliminate air into the water stream being delivered by the whirlpool pump to the hydro jets. Turning it one direction will allow more air into the water stream and result in a more vigorous massage being provided by the hydro jets. Turning the Water Mixture Control in the opposite direction will restrict the amount of air being allowed into the water system, resulting in a more gentle massage.

? CAUTION:
DO NOT RUN WHIRLPOOL DRY! DO NOT ATTEMPT TO OPERATE THE JETS UNTIL THE WATER HAS FILLED THE TUB ABOVE THE LEVEL OF THE HIGHEST JET!

CLEANING & MAINTENANCE

Water jets and pipe circulation systems
Water jets and pipe circulation systems should be flushed before first use and on a monthly basis when product is under normal use. Below are the recommended procedures for cleaning:

  • Fill the tub with hot water 2-3 inches above the jets and add 2-3 teaspoons of low foaming detergent such as dishwashing machine detergent.
  • Turn on jet massage system and run for 10 minutes.
  • Drain tub completely.
  • Fill tub with cold water above jets.
  • Turn on jet massage system and run for 15 minutes.
  • Drain tub completely.
  • Cleaning the “suction cover”: Clean and remove any hair or lint from the suction cover. On a monthly basis, unscrew the suction cover and clean away any hair, lint or debris from the cover and housing, then remount the cover in place. Some suctions are not designed to be removed; only suctions that have screws on the cover, visible from the inside of the tub, can be removed.

⚠ WARNING:
Never operate the unit with the safety suction cover off.
? CAUTION:
Do not run the water jets system dry.

Bathtub body
After each use, rinse all exposed surfaces with warm water, then wipe tub completely dry.
Once a week, wash all exposed surfaces of the bathtub with a mild solution. Oily or greasy spots can be lifted with denatured alcohol.

Door seal
Periodically wipe down the door seal and door jamb to maintain the integrity of the water seal. In order to keep the door seal and door jamb clean and not accumulate dirt or debris of any kind, clean seal and jamb with a mild detergent and warm water using a soft cloth.
THE DOOR SHOULD BE LEFT OPEN WHEN THE BATHTUB IS NOT IN USE. This allows the door seal to relax and resume its natural shape and flexibility.

? CAUTION:
Must empty the bathtub and the water in the pipe during the winter use. It is possible that the pipes could freeze, rupturing the pipes or equipment.
Use no water other than standard tap water. The use of well water or spring water could cause corrosion, which could lead to leaks.
Bathtub should be prevented irradiating by ultraviolet light or bright light, otherwise it will accelerate the aging of surface of the bath.
Keep far away from cigarette butts, hair dryer and other heat sources, the product will be damaged due to contact with high temperature.
Do not strike the surface of the bathtub with hard objects. Doing so could crack or scratch the bathtub or cause leaks that damage household property.
When the product is in operation do not cut off any connection lines. Doing so may cause product leakage, electric shock, or other accidents.

⚠ WARNING:
The ground fault circuit interrupter (GFCI) should be tested regularly, it is better to test before each use.

LIMITED WARRANTY

Coverage
Limited lifetime warranty on the tub shell, frame, and door gasket under normal use and conditions. However, does not apply to finish that is fading delaminating, or scouring due to excessive cleaning, wear or sun fading.
– All door hardware and locking mechanism: 5 years
– Roman faucet and hand shower: Lifetime limited
– Whirlpool pushbutton control: 5 years
– Motor (s): 2 years
– Drain with overflow: 5 years
– Grab bars: 5 years

If, during this period a covered component fails, we will provide a replacement part to the owner through contacting Lowes. Shipping charges and all other incidental costs are not included. All warranty claims must be coordinated through lowes.

Limitations
All warranties terminate immediately upon the transfer of home ownership. All warranties assume normal and reasonable use of Lowes Walk-In Tub.
The Limited Warranty does not cover defects, damage or failure caused by the shipment, delivery, installation or user, including but not limited to: modification of any type for any reason, electrical or water connections not specified by the installation and specifications included with the unit, improper installation, unreasonable operation, accident, neglect, lack of proper routine maintenance, or acts of God, including, earthquakes, floods, lightning, etc. Lowes expressly disclaims any liability for any cost of defects or damages with respect to installation by third party contractors. This warranty is not transferable.
The finish’s warranty does not apply to fading, cracking, delaminating or blistering due to excessive wear, sun fading or scouring due to cleaning.

Requested Service
Should the original purchaser/homeowner request service on any aspect or function of the walk-in tub please contact Lowes at 866-389-8827 8 a.m. – 8 p.m., EST, Monday – Sunday. Lowes. will supply parts covered under warranty at no additional charge to customer subject to the exceptions, limitations, disclaimers, and other terms and conditions contained in this document.

Warranty Service
In order to make a claim under this warranty, the original consumer / purchaser must notify we no later than fifteen (15) days from occurrence and must be within the expressed warranty period(s). To submit a claim, please provide a signed and dated copy providing proof of purchase of either the home or remodel job, warranty registration card dated and filled out. Submit to Lowes along with your home address. Warranty service requests can be call our customer service department at 866-389-8827. You could also contact us at partsplus@lowes.com or visit www.lowespartsplus.com.
Upon receipt of the claim if it is determined that a valid claim exists under one or more of the warranties, the defective product or component will be shipped to the customer. In the event Lowes must replace a product or component and the original replacement is no longer available, Lowes Inc. or its designated representative shall have the right to substitute a product or component designated by Lowes Inc. or its designated representative to be of equal quality. Replacement of product or component does not renew the warranty period. Non-warranty requests for repair or adjustment may result in additional service charge. This warranty excludes any labor incurred due to insufficient access to components, including but not limited to electronics, pumps and plumbing.

? CAUTION:
Damage due to dry operation of pumps is not covered under warranty.