COSTWAY ES10262DE Dehumidifier User Manual
- June 15, 2024
- COSTWAY
Table of Contents
- Before You Start
- Precautions
- Operation and efficiency
- Parts Names and Functions
- Operation manual
- Select proper functions
- Preparations and inspection while beginning the operation
- Maintenance notices
- Continuous drainage
- Malfunction disposals
- Performance parameters
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Dehumidifier/Luftentfeuchter/
Meet delights for your home here
Home of Delights ES10262DE
THIS INSTRUCTION BOOKLET CONTAINS IMPORTANT SAFETY INFORMATION. PLEASE READ
AND KEEP FOR FUTURE REFERENCE.
office: Fontana
If you’re having difficulty, our friendly customer team is always here to
help.
USA:cs.us@costway.com
Before You Start
Please read all instructions carefully.
Retain instructions for future reference.
Separate and count all parts and hardware.
Read through each step carefully and follow the proper order.
We recommend that, where possible, all items are assembled near to the area in
which they will be placed in use, to avoid moving the product unnecessarily
once assembled.
Always place the product on a flat, steady and stable surface.
Keep all small parts and packaging materials for this product away from babies
and children as they potentially pose a serious choking hazard.
Please read this manual carefully before using this dehumidifier.
Since the operation guide contained in this manual is very important, please
keep it properly.
Precautions
Please read “Precautions” carefully before operating your dehumidifier.
The warnings and the cautions stated in “Precautions” must be observed for
safe operation.
Warning: means improper handling may result in a death or a serious
injury to a person.
Cautions: means improper handling may result in an injury or damage to
properties.
Shows Prohibition
● Shows Compulsion
Shows Caution
Caution, risk of fire
Warnings
In case of any abnormality, be sure to turn off the dehumidifier, disconnect
the plug and make contact to the seller of your appliance. (Abnormal operation
may result in a failure of the unit, electric shock, fire, or the like.)
Never attempt to turn off the dehumidifier by disconnecting the plug.
Never modify the dehumidifier. Do not attempt to disassemble or service the
unit by yourself.
Keep your hands dry while plugging into or pulling off the plug to avoid
electric shock.
AC220-240 volt of alternating current is applied to this equipment.
Remove any dust from the blades of the power plug and insert the plug into an
outlet securely.
To avoid the risk of fire or explosion, do not spray to the dehumidifier. Do
not put any inflammables or chemicals near the unit.
To prevent resin parts from melting or catching on fire, do not place the
dehumidifier near heating appliances.
Do not connect the dehumidifier to an outlet having the electrical ratings
below the dehumidifier’s.
The power cord must not be damaged or modified.
Do not put any hot or heavy thing on the cord. Do not pull it out, or bundle
it during operation.
To avoid damages to the power cord, do not pinch the cord in a door.
Never put rods or objects into the openings of the dehumidifier. Because this
unit contains a fan running at high speed, contact with the rotating fan will
cause danger.
Remove water that has been collected in the tank.
(Accidentally drinking of the water or using it for other purpose may cause
illness and /or unforeseen accidents.)
Risk of electric shock. Disconnect power before servicing unit.
Moving parts. Do not operate the unit with back cover removed.
Hot parts. Do not operate the unit with back cover removed.
Risk of electric shock-switch in off position does not de-energize all loads.
WARNING
Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating
ignition sources (for example: open flames, an operating gas appliance or an
operating electric heater).
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
Correct disposal of this product
**** This marking indicates that this product should not be disposed with
other household wastes throughout the EU.
To prevent possible harm to the environment or human health from uncontrolled
waste disposal, recycle it responsibly to promote the sustainable reuse of
material resources.
a. “The appliance shall be installed in accordance with national wiring
regulations”.
b. “If the supply cord is damaged, it must be replaced by the manufacturer or
similarly qualified persons in order to avoid a hazard.”
c. “This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.”
d. “Children should be supervised to ensure that they do not play with the
appliance.”
Cautions
The dehumidifier must be used on a level and stable surface.
To prevent the water from freezing, do not use the dehumidifier and the drain
hose at ambient temperature below 0°C.
Do not use the dehumidifier outside. Exposure to direct sunlight or rain may
result in overheating, electric shock and fire.
Do not put water vessel on the dehumidifier (In case of any spill of water,
the water gets into the unit and deteriorates the insulation).
Never attempt to use the dehumidifier for special uses, such as food or
preservation of art objects, or the like.
The deterioration of preserving quality may be caused.
Do not use the dehumidifier where any leakage of oil or flammable gas may take
place.
Do not use the unit in places subject to chemicals.
For continuous draining, make sure that the drain hose is set properly without
a rising slope.
Be careful that a heating appliance is not exposed to the wind from the
dehumidifier.
Do not use the dehumidifier as a chair or a footstool.
For safety purpose, disconnect the power plug if the unit is not used for a
long time.
Be sure to take hold of the power plug when plugging in and out of an outlet.
In case of using the dehumidifier in a closet, be sure to prevent children
from getting in the closet.
Do not remove the float lever from the water tank.
To avoid damages to the power cord, do not pull out the cord when moving the
unit.
Do not block up the air intakes and the air outlets. Do not cover the unit
with washed clothes.
Prior to continuous operation for a long duration, periodical checking is
required especially for the air clean filter, the drain hose, or the like.
Turn off the unit and disconnect the power plug before starting any cleaning
or other routine maintenance.
To avoid the risk of electric shock, never sprinkle or spill water on the
dehumidifier when cleaning.
Turn off the unit and empty the water out of the water tank when moving the
unit. Be sure to hold the handle when moving.
Operation and efficiency
Defrosting operation
The evaporator in the dehumidifier may defrost automatically if it is
operated in the room temperature less than 18°C. The defrosting device may
start up and operate for some time (about 5 minutes) automatically every 25
minutes or even longer.
- During the defrosting operation, the dehumidification function and air purification function may intermit.
- Please don’t turn off the switch or pull out the power plug of the dehumidifier during the defrosting operation.
This dehumidifier can’t be applicable to keep extreme low temperature.
The purpose of this dehumidifier is to pump off the unpleasant high humidity
in daily life and dry the wet things. But it can’t be used to keep extreme low
temperature.
The room temperature increases during the operation.
This dehumidifier doesn’t have cooling function. It will produce heat during
the operation and increase the room temperature to 1 to 4° C. This temperature
rise may be very distinct in the cabinet or other similar spaces. In addition,
the door and windows are closed and other appliances in the room can give out
heat as well as the radiation of the sun can raise the room temperature.
Dehumidifying capacity
The illustration below shows the daily dehumidifying capacity of the
dehumidifier. This capacity is based on the 30°C of room temperature the
dehumidifier sets, 80% of relative humidity and the data when the air outlet
is fully open. At different temperatures and relative humidity, it may have
different dehumidifying capacities.
In the same room temperature, the dehumidifying capacity is higher in higher
relative humidity and the dehumidifying capacity is lower in lower relative
humidity. In the same relative humidity, the dehumidifying capacity is higher
in higher temperature and the dehumidifying capacity is lower in lower
temperature.
If the dehumidifier is placed in the cabinet, its dehumidifying capacity may
highly reduce in a short period after operating, that is, the humidity in the
cabinet has been highly reduced.
Parts Names and Functions
Installation
The following space must be maintained to ensure the operating efficiency of
the dehumidifier.
Operation manual
Continuous mode
Drying mode
Defrost
Timing
Full of water
Operation manual
-
Power button
Used to turn on and turn off. -
“+” and “-” keys
a. Humidity can be set (humidity adjustment is only effective in continuous mode), the setting range is 30%-80% (5% adjustment coefficient)-CO(forced operation), the above setting cycle is adjustable, and the digital tube flashes for 5 seconds when setting, and it will automatically exit the setting state if there is no operation within 5 seconds.
b. Press the “+” and “-” keys at the same time to enter the timing, and then press the “+” or “-” keys to to set the timer. -
Dehumidification button
Press this key to cycle between the continuous mode and the drying mode.
To change mode with a delay of 5 seconds for confirmation.
Select proper functions
MODE
Lower the indoor humidity to a comfortable humidity.Indoor humidity or prevent condensation and mildewing on
the ceiling or wall.
To dry washed cloth faster
Preparations and inspection while beginning the operation
Confirm the tank is installed in position.
The dehumidifier can’t operate if the water in the tank is full or isn’t
installed well.
-
How to move the water tank.
Hold the sides of the water tank and pull the tank out. -
Method to empty out the water tank.
1. Pull out the water tank from the dehumidifier.
2. Incline the water tank according to the indication direction and empty out the water slowly.
3. Install the water tank back into the dehumidifier.
Maintenance notices
Warning
Please don’t plug in with wet hands to avoid electric shock. Notice
Please cut off the power supply before daily cleaning and maintenance. Don’t
dismantle the floater from the water tank.
If the machine unit is not in use for extended periods:
- Empty out the water in the tank, wipe up the water tank and install it back.
- Clean the filter.
- Place the machine unit upright and avoid the direct sunlight.
Requirement
Please place the machine unit upright to avoid misoperation and unusual sound.
Machine body
Wipe up the dehumidifier with wet cloth (put it into the water and wring it
out). Don’t clean the control unit with wet cloth.
Don’t clean the machine unit with gasoline, thinner or liquid detergent to
avoid deformation and fission of the machine unit.
The cloth contains chemicals may change the color of the machine unit.
Clean filter net (Maintain it every two weeks.)
The dehumidify capacity may reduce when the filter net is clogged with
defilement.The dust collector is always used to clean the
dust. If the filter net is too dirty, it can be cleaned with water, then
install it back after the filter dries.
Continuous drainage
Continuous drainage
When you are not at home but need unit to make long-term operation, you can
use the continuous drainage feature.
Pull the plug, take out the water tank and insert the pipe. Warning
Please don’t catch the power line in the door to avoid damaging it. Notice
Please keep the children away from the dehumidifier, if it is used in the
cabinet.
Malfunction disposals
Please check each item first before applying for maintenance
Malfunctions | Possible causes | Solutions |
---|---|---|
No working | Check whether the power plug is connected. | Plug in. |
Whether the water tank is full. | Empty out the water in the tank. | |
Whether the water tank is in position. | Place it well. | |
Small dehumidifying capacity. | Whether the filter is too dirty. | Clean the |
filter.
Whether the air inlet and outlet are blocked.| Remove the object blocked or
move the dehumidifier to ensure certain inlet and outlet air.
Big noises| Check whether the machine unit is placed well.| Place the machine
unit on the smooth and stable floor.
Stop during the dehumidifyi ng process.| Whether the room temperature is too
high or too low and out of the working scope of the dehumidifier.| The
dehumidifier may start automatically when the room temperature returns to the
working scope.
The clothing can’t be dried fast.| Check whether the machine unit is placed
well.| The wet clothing may dry more slowly in low temperature.
Make sure the phenomena below happen while the malfunctions above are not included:
Phenomenon | Causes |
---|---|
Intermittent stop during the operation | The defrosting |
Small dehumidifying capacity | The dehumidifying capacity drops with the room |
temperature and humidity. See the illustration above for reference.
The humidity of the room can’t reduce| The room area is too big, which is over
its application scope.
The door and windows of the room aren’t closed.
The machine unit is operated with a kerosene heater (which releases steam)
together.
Unpleasant smell| The smell may come from the wall, furniture and other
things.
The machine unit makes a sound during operation.| The sound made by the
flowing of the refrigerant may eliminate or lower automatically while the
system operates stably.
Water is in the tank.| Since each machine unit has taken operation test before
leaving the factory, some water remains on the evaporator flows to the water
tank.
The FULL indicator light is on.| When the water tank is full, the FULL
indicator light is on for reminding.
Performance parameters
Model: ES10262DE
Power supply: AC220V-240V~ 50Hz
Dehumidifying capacity: 12 L/day (30°C 80%) 6 L/day (27°C 60%)
Input power: 250W
Rated current: 1.45A
Water tank capacity: 2.1L
Net weight: 9 kg
Overall dimensions: 270 x 205 x 406.5mm(L x W x H)
Application scope: 5-32°C
Refrigerant: R290
Fuse: 3.15A/250VAC
The parameters above may change with the improvement of the machine unit
without further notice. See the nameplate for details.
Return / Damage Claim Instructions
DO NOT discard the box / original packaging.
In case a return is required, the item must be returned in original box.
Without this your return will not be accepted.
Take a photo of the box markings.
A photo of the markings (text) on the side of the box is required in case a
part is needed for replacement. This helps our staff identify your product
number to ensure you receive the correct parts.
Take a photo of the damaged part (if applicable).
A photo of the damage is always required to file a claim and get your
replacement or refund processed quickly. Please make sure you have the box
even if it is damaged.
Send us an email with the images requested.
Email us directly from marketplace where your item was purchased with the
attached images and a description of your claim.