King Electric LPWV2015 Lpwv Vandal Resistant Heater Instruction Manual

June 15, 2024
KING ELECTRIC

King Electric LPWV2015 Lpwv Vandal Resistant Heater Instruction Manual

INSTALLATION AND MAINTENANCE

LPWA Series
Architectural
Wall Heaters
LPWA1222 LPWA2445 LPWA2740
LPWA2045
(Including Factory Installed Options

With US & Global Materials

UNIVERSAL INSTRUCTIONS

DANGER
ELECTRIC SHOCK OR FIRE HAZARD

READ ALL WIRE SIZING, VILTAGE REQUIREMENTS AND SAFETY DATA TO AVOID PROPERTY DAMAGE AND PERSOIAL INJURY

UNIVERSAL INSTRUCTIONS

WARNING

CAREFULLY -Ise the heater only as described in this manual. Any other use is not recommended and could result in fire, electric shock, and personal injury. Following these instructions will prevent difficulties that might occur during the installation and use of the heater. Please study the instructions first, as they may save considerable time and trouble during use addition to providing important safety information. Make sure to save these instructions for future use.


  1. WARNING:
     Power must come to heater first.


  2. WARNING
    :   Read all instructions before wiring or using this heater.


  3. WARNING:
     This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, boxes, etc., and curtains must be at least 3 feet away from the front and sides of heater.


  4. WARNING;
      Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.


  5. WARNING:
    . Do not operate any heater after it malfunctions. Disconnect power at service panel and have heater inspected by a qualified electrician for repair before reusing.


  6. WARNING:
    . Do not use outdoors.


  7. WARNING:
    To dis onnect heater, turn controls to OFF, and turn CFF power from main service panel.
    Figure 2


  8. WARNING:
    Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock, fire, or damage to the neater.


  9. WARNING:
    To prevent the possibility of fire, do not block air intakes or exhaust in any manner.

  10. WARNING : . A heater has hot and arching or sparking parts inside. Do not use it in areas where gasoline, paint, or any other flammable vapors or liquids are stored.


  11. WARNING:
    . Use this heater only as described in the manual. Any other use is not recommended by the manufacturer and may cause fire, electric shock, an explosion, injury or death to people and or property.


  12. WARNING
     This heater includes Smart limit protection that shuts down heater in the event of excessive over heating. To reset heater

KING ELECTRIC MFG CO-9131 10TH AVENUE SOUTH SEATTLE, WA 98108 PH:206 762 0400 FAX: 206-763 7738 www.king-dectric.com

LPWA INSTALLATION INSTRUCTIONS

CAUTION! Turn OFF all electrical power to install heater

ADANGER

ELECTRIC SHOCK DR FIRE HAZARD
READ ALL WIRE SIZING, VOLTAGE REQUIREMENTS AND SAFETY DATA TO AVOID PROPERTY DAMAGE AND PERSONAL INJURY

Selecting a location for your heater:

Do Not install less than 6 inches from vertical side walls or open edge of door. This heater must have an unrestricted airflow. Do Not select a location where it is likely to be blocked by furniture, curtains, etc. Be sure the location selected allows sufficient space for the heater as shown below by Table 1. Do Not locate this heater in ar area where combustible vapors, gases, flammable liquids, or excessive lint, dust or moisture is present.

Rating Label Location

King Electrical Mfg. Seattle Wa
Do Nut install Lane The Ver Nut Loss Than 4 Above The Fisiated Floor. The Enticel Power To The Heater is To Be Disconnected Before The Brill Rod For Cleaning. De Wat Sperals The Heater with Removed. For een Who LPWW La Pete Lois De Murage Vert Pat MODEL-LPW2740T WATTS: 4000 VOLTS: 277 CACLE MORMON WATTE THIS HEATER IS WIRED FOR 277 VOLT:4000-3000-2000-1000 MADE IN U.SA

Minimum Clearances for heater:

Front| TOP| BOTTOM| SIDES
36| 12 in| 4 in| 6 in
0.9 m| 30.5 cm| 10.2 cm| 15.2

The wire and breaker sizing chart will give a general rule of installation size. Consult an electrician if you are not knowledgeable about wiring codes.

Wire & Breaker Sizing: WIRING: Branch Circuit Connection

Total Amps| Minimum AWG. Wire Size (Copper| Circuit Breaker or Fuse F Size
---|---|---
0 thru 12| 14| 15 amp
12.1 thru 16| #12| 20 amp
16.1 thru 24| #10| 30 amp

  1. Connect heater only to the voltage, amperage and frequency specified on the nameplate.
  2. Wiring procedures and coniections shall be inaccordance with all National and local codes having jurisdiction.
  3. Set the bag containing the grill and packet with (4) grill screws aside. 4. Loosen mounting screws and remove fan heater assembly.
  4. A knockout of 1/2 inch conduit size (7/8 inch) is providec in the back and side of the heater for power to enter. Provide proper train relief connectors (not included) for your wire entering the wall box.
  5. Install wall box a minimum of 6 inches from vertical side walls and 4 inches above floor.
  6. Secure wall box to the 2 x 4 studs using the (2) holes or the side of the wall box. Secure to wall stud on opposite side if required.
  7. Connect supply wires, attach ground feed wire to the green ground wire with wire nuts.
  8.  Reinstall heater assembly into wall box with screw at top of interior.
  9. Install gril securely with screws provided. Do Not over tighten.
  10. Test unit by turning thermostat up past room temperature. You will see a puff of smoke as the elements are energized and thefan turns on. This is a normal burn off of marufacturing lubricants and will dissipate in 5 minutes.
  11. Heater will continue to run until the room temperature you set is reached and then turn itself off until temperature drops apir.

NOTE ABOUT FAN DELAY FEATURE : The fan delay feature enables the fan to run after the thermostat turns off in order to remove resicual heat from the elements. You may see the fan cycle on and off a few times until the elements have coolec. This is normal operation.

OPERATING INSTRUCTIONS

TROUBLESHOOTING

SYMPTOM PROBLEM SOLUTION
Breaker Trips 1.   Short Circuit2.   Overloaded Circuit3.   Improper Voltage

1.  Find source of short. Trace heater circuit and verify the heater is wire aroperly.2.  Reduce wattage in circuit. REfer to circuit sizing table for maximum wattage.3.  Verify the heater \ oltage matches the supply voltage.
Heater not working| 1.   No Power2.   Loose Connections3.   Defective Limit| 1.  Turn Breaker ON. turn tiermostat ON, check that tie breaker is position properly on panel bus-tar. A 2-Pole breaker must be connected to both bus-bars (A & B pine) to produce 240V power.2.  Tighten wire connections.3.  By-pass the limit to test. If heater works, replace the limit
Heater Smokes| 1.   Oil on element2.   Needs Cleaning| 1.    It is ncrmal for tie element to burn off some light finishing oil used in the manufac­turing process when first erergized. Open windows and allow room to vent until it stops. usually within a few ninutes.2.     Remove any dust or dirt accumulations.
Room Temperature does not match thermostat setting.| 1.     Thermostat affected by another heat source.2.      Improper calibration| 1.  Sunlight or other heat sources can affect the thermostat. Move the thermostat to another location or remove the heat source.2.  Remove cover and adjust calibration screw.
Room Temperature swings from too hot to too cold.| 1. Defective or low quail-ty thermostat| 1. Replace with a better quality thermostat. Anticipated thermostats are tally accu­rate: and electronic thermostat 15 best.

LPWA 120V/208V/240V STANDARD WIRING DIAGRAM

This heater is shipped from the factory wired for maximum wattage. To reduce the wattage unplug (disconnect) an insulated push on terminal and wrap with electrical tape to prevent the possibility of electrical contact with other parts.
knob position OFF…….L1-0, L2-0
knob position FAN…….L1-2, L2-4
knob position HEAT……L1-1, L2-4, L2-3
FAN DELAY
1-3 N.C., 1-2 N.C. 1-2 Closes on Temp Rise

LPWA 120V/208V/240V with CT24 Option WIRING DIAGRAM

INSTALLATION INSTRUCTIONS
This heater is shipped from the factory wired for maximum wattage. To reduce the wattage unplug (disconnect) an insulated push on terminal and wrap with electrical tape to prevent the possibility of electrical contact with other parts.
knob position OFF…….L1-0, L2-0
knob position FAN…….L1-2, L2-4
knob position HEAT……L1-1, L2-4, L2-3
FAN DELAY
1-3 N.C., 1-2 N.C. 1-2 Closes on Temp Rise

LPWA 277 VOLT MODEL STANDARD WIRING DIAGRAM

INSTALLATION INSTRUCTIONS
This heater is shipped from the factory wired for maximum wattage. To reduce the wattage unplug (disconnect) an insulated push on terminal and wrap with electrical tape to prevent the possibility of electrical contact with other parts.

knob position OFF…….L1-0, L2-0
knob position FAN…….L1-2, L2-4
knob position HEAT……L1-1, L2-4, L2-3
FAN DELAY
1-3 N.C., 1-2 N.C. 1-2 Closes on Temp Rise

LPWA 277 VOLT MODEL with CT24 Option WIRING DIAGRAM

INSTALLATION INSTRUCTIONS
This heater is shipped from the factory wired for maximum wattage. To reduce the wattage unplug (disconnect) an insulated push on terminal and wrap with electrical tape to prevent the possibility of electrical contact with other parts.

knob position OFF…….L1-0, L2-0
knob position FAN…….L1-2, L2-4
knob position HEAT……L1-1, L2-4, L2-3
FAN DELAY
1-3 N.C., 1-2 N.C. 1-2 Closes on Temp Rise

FIELD WATTAGE SELECTION

Field Wattage Selection

A-ORANGE: Disconnects 750 Watts
B-BLUE: Disconnects 500 Watts
C-YELLOW: Disconnects 250 Watts 120V 2250W
D-BLACK: Do Not Disconnect (Common )
E-RED: Do Not Disconnect

120V 2250W Pic-A-Watt
Metal Sheath Element

Field Wattage Selection

A-ORANGE: Disconnects 1000 Watts
D-BLACK; Do Not Disconnect (Common

277V 4000W
Pic-A-Watt® Metal Sheath Element

Field Wattage Selection

A-ORANGE: Disconnects 1000 Watts
B-BLUE:  Disconnects 750 Watts
C-YELLOW: Disconnects 500 Watts
D-BLACK: Do Not Disconnect (Common)
E-RED:   Do Not Disconnect
208/240V 4500W
Pic-A-WattⓇ Metal Sheath Element

SMART LIMIT PROTECTION

This heater is ecuipped with a thermal overload SMART LIMIT PROTECTION which disconnects elements (fan delay & fan only function still workst in the event normal operating temperatures are exceeded. If thermal overload trips due to abnorma operating temperatures, thermal overload remains open until manually reset by turning the heater Off for 15 minutes. Inspect for any objects on or adjacent to the seater that may cause high temperatures. After inspecting the heater, keep the power to the heater off for 15 minutes to reset the SLP thermal protector. If the SLP thermal protector
PROTECTION shuts the heater off again, immediately turn the heater OFF at the circuit breaker and inspect the heater for possible fan motor faiure or dit and lint on the heating element. Repeat the sarting procedure

DO NOT TAMPER WITH, BYPASS OR REMOVE THIS HIGH LIMIT DEVICE.

OPERATING INSTRUCTIONS

General information and guidelines:
This heater must be properly installed before it is used. DO NOT tamper with or change the operation of this heater. Service personnel refer to Maintenance & Warranty section for service of any type.
Operation:

  1. This heater must be properly installed in accordance with the National Electrical Codes (NEC) & local electrical codes before it is used.
  2. After the electric leader has been completely installed, all thermostats should be turned to LOW or NO HEAT. Turn ON preachers test fan Only ther turn to heat & turn up thermostat, wait 3 to 5 minutes. Check to see that the heater is operating correctly. If the heater is not prating, disconnect power by turning Off heater & breaker and check wiring connections.
  3. Allow entire system to operate steadily for 1/2 hour. This should remove oily residue from manufacturing. (Some smocking may occur). 4. Select the setting for comfort on thermostat.
  4.  A safety limit control is provided to turn off the heater automatically if it is blocked or otherwise overheats due to an abnormal condition. DO NOT bypass or remove this safety device from the electrical circuit-see Warning Figure 2-2 on page 5. During Norma use, this safety control should not operate. If you find that this control is operating, make sure the heater is not being blocked. If it continues to cycle the beater off, disconcert power to heater and have it checked and or repaired by a qualified electrician.

MAINTENANCE & WARRANTY

Maintenance & Cleaning: Basic maintenance is listed below and should be performed annually. When necessary, any required servicing should be performed by qualified service personnel. Your heater will give you years of service and comfort with only minimum care. To assure efficient operation follow the simple instructions below.
WARNING: Turn the electrical power OFF at the electrical panel board (circuit breaker or fuse box) and lock or tag this panel board door to prevent someone from turning on power while you are working on this heater. Failure to do so could result in serious electrical shock, burns, or possible death.

Figure 2
Before deaning this heater, the heating element of the heater must be cool.

  1. Before removing grille, turn the electrical power OFF. Circuit breakers are often not marked corectly and turning the wrong treaker off could mean electricity is flowing to the heater, even if the heater does not appear to be working. If you are uncomfortable working with electrical appliances, unable to follow these guidelines, or do not have the recessary equipment, consult a qualified electriciar. Once you verify the power is off completely, proceed to the next step.
  2. Remove screws and take off grille. Wash grille with hot soapy water and dry immediately 3. Using a hair dryer or vacuum on blow cycle, hold the fan in place to prevent it from turning and blow debris back through the element. Do not touch element. Vacuum lose dearis without touching the elements.
  3. Replace grille and secure with screws.
  4. Turn thermostat o desired setting.
  5. Turn power back ON at the electrical panel board

WARRANTY INFORMATION

King Electrical Manufacturing Company will repair or replace, without charge to the original owner, any LPWA Series heater found to be defective or malfunctioning within 5 year of installation. This warranty requires the owner or his agent install the equipment in accordance with the National Electrica Code, any other applicabe heating or electrical coces, and the manufacturer’s installation instructions. It further requires that reasorable and necessary maintenance be performed on the unit. Failure to properly maintain the unit will result in the warranty being voided. The company is not liable for abuse or misuse of product as may be finally determined by the compary. The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs and shipping costs incurred to return products to King Manufacturing, King Manufacturing will repair or replice, at our option, at no charge to the customer with return freight paid by King, King Manufacturing shall not be liable for consequential damages arising with respect to the product, whether based upon negligence, tort, strict liability or contract. No other written or oral warranty applies, nor any warranties by representatives dealers, employees of King, or any other person. All returns require a King Return Goods Authorization (RGA); Unauthorized returns will be refused. Do not return malfunctioning/defective products to store.

Smart Heating Solutions

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

KING ELECTRIC User Manuals

Related Manuals