WARNING
READ CAREFULLY – U se the heater only as described in this manual. Any
other use is not recommended and could result in fire, electric shock, and
personal
injury. Following these instructions will prevent difficulties that might
occur during the installation and use of the heater. Please study the
instructions first, as
they may save considerable time and trouble during use addition to providing
important safety information. Make sure to save these instructions for future
use .
WARNING
To prevent a possible electrical shock, disconnect all power coming to
heater at main service panel before wiring or servicing .
- All wiring must be in accordance with the National Electrical Code (Canadian Electrical Code in Canada) and all applicable local codes. The heater must be grounded as a precaution against electrical shock. Supply wiring must be copper and suitable for at least 75° C .
- Verify power supply and control voltages coming to the heater match the ratings printed on the heater nameplate before energizing .
- Heater must be installed so the minimum clearances shown in Specifications table are maintained .
- This heater is NOT suitable for use in hazardous locations as described by the National Fire Protection Association (NFPA). this heater has hot and arcing or sparking parts inside. DO NOT use in areas where gasoline, paint or other flammable liquids are used or stored
- The mounting structure and anchoring hardware MUST BE capable of reliably supporting the weight of the heater plus mounting bracket if used. Refer to specifications table for heater weight.
- To prevent a possible fire, DO NOT block air intakes or exhaust openings in any manner. DO NOT allow foreign objects to enter grill openings as this may cause electric shock, fire or damage to heater.
CAUTION-RISK OF ELECTRIC SHOCK
- DO NOT OPEN HEATER SHELL -NO USER-SERVICEABLE PARTS INSIDE
IMPORTANT SAFETY INSTRUCTIONS
READ CAREFULLY
The infrared heater is designed for safe operation. Nevertheless,
installation, maintenance and operation of the heater can be dangerous.
Observing the following procedures will reduce the risk of fire, electric
shock, injury to persons and keep installation time to a minimums. Save these
instructions for future used.
- Read all instruction before using this heater.
- Remove the unit from it’s packaging and check to make sure it is in good condition before using.
- Do not let children play with parts of package (such as plastic bags).
- Check the household voltage to ensure it matches the heater’s rated specification.
- This heater is very hot when in use. To avoid burns, do not let bare skin touch hot surfaces. If provided, use handles when moving this heater. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 3 feet (0.9 m) from the front of the heater and keep them away from the sides and rear.
- Use extreme caution when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.
- Do not use near or in the immediate vicinity of a bath or swimming pool or any source of liquid.
- To protect against electric shock, do not immerse in water or any other liquid.
- Do not insert or allow foreign objects to enter any ventilation or exhaust opening, as this may cause an electric shock, fire or damage.
- Do not put fingers or foreign objects into the grill while in operation.
- Do not leave the appliance unattended when in use.
- This heater is not intended for use in bathrooms, laundry and similar indoor locations. Never locate heater where it may fall into a bathtub or other water container.
- No liability can be accepted for any damage caused by non compliance with instructions or any improper use or mishandling.
- This appliance is not intended for use by persons (including children) with reduces physical, sensory or mental capabilities or lack of experience and knowledge. Supervision is to ensure they do not play with the appliance.
- Use this heater only as described in this manual. Any other use Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
- To disconnect heater, turn controls to off, and turn off power to heater circuit at main disconnect Panel.
- To prevent overheating of this appliance, keep the air inlets and outlets clean and free of anything that may cause blockage. Check all inlets and outlets from time to time to ensure it is clear of any dirt or dust accumulation. DO NOT COVER. To prevent a possible fire, do not block air intakes or exhaust in any manner.
- A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored.
- Parts of the heater may exceed 392F. Contact with the heating tube, reflector, or metal parts near the heating tube, may cause severe BURNS . Do not touch heater when in use.
- NEVER place hands under the heating elements. ALWAYS allow heating element to cool at least 1 O minutes before touching the heating tube or adjacent parts.
- This product contains recyclable materials. Do not dispose this product as unsorted municipal waste. Please contact your local municipality for the nearest collection point.
MINIMUM CLEARANCES TO COMBUSTIBLES
Minimum Clearances to Combustibles in Inches
Mounting Angle| |——–Side——- |
Front Behind
| End| Top| Below| Min. Mtg. Height
---|---|---|---|---|---
0°| 1’7″| 1’7″| 1’7″| 9.4″| 7’9″| 7’9″
45°| 3’3″| 6.5″| 1’7″| 1’7″| 7’9″| 7’9″
NOTE:
Ensure that building materials with a low heat tolerance (i.e, awnings,
fabrics, plastics, sprinklers, insulation, etc.) are protected against
degradation. This may require the heater to be mounted at a distance in excess
of the published clearances to combustibles. Contact the material manufacturer
for specific details of safe temperatures.
Clearances to Combustibles
TOP VIEW
0° Mounting Angle
END VIEW
0° Mounting Angle
END VIEW
45° Mounting Angle
INSTALLATION
Heating Application Chart
Series
| Heater Wattage| Lamp Quantity| Minimum Mounting Height (Ft)| Recommended
Mounting Height [Dim. A]|
Recommended Distance Between Heaters (Ft)*
[Dim. B]
---|---|---|---|---|---
RK| 1500W| 1| 7’9″‘| 8′ to 9′| 5′ to 10′
NOTE:
Minimum Clearances to combustibles published in this manual and on safety
labels must be maintained at all times. Factory recommended mounting heights
are listed as a guideline.
If infrared heaters are mounted too low or too high, they may result in
discomfort or lack of heat. Test surrounding materials to verify that nothing
is getting hotter than expected.
Coverage Area Chart
Series
| Heater Wattage| Lamp Quantity| AVERAGE Coverage Of Heater
Length X Width (Ft.)| *COLD/WIND
Coverage Of Heater Length X Width (Ft.)|
**PROTECTED
Coverage Of Heater Length X Width (Ft.)
---|---|---|---|---|---
RK| 1500W| 1| 5’ x 5’| 3’ x 3’| 7’ x 7’
NOTES:
- Heaters can provide less than average coverage in extremely cold/windy conditions.
- Indoor or well-protected environments will generally exceed average coverage areas.
Heater Dimensions
Series | A | C |
---|---|---|
RK – 1 Lamp | 7.5” – 8.25” | 24” |
IMPORTANT SAFETY INSTRUCTIONS
Correct Installation Position – 01
Note:
Mounted angle with 30°- 45 °.
Correct Installation Position – 02
Note:
Heater should be wall or ceiling mounted under well protected enviornments, at
least keep 3feet (0.9m) away from any combustible objects.
Note:
Do not cover.
WARNING
Warning – to reduce the risk of fire
Caution:
Keep combustible materials, such as furniture, pillows, curtains at least
3feet (0.9m) from the front of the heater and keep them away from the sides
and rear. Caution:
Do NOT use with an extension cord or relocatable power tap (outlet/ power
strip).
Caution:
Hot surface, do NOT touch.
Caution:
Do NOT cover with any objects such as blanket on the heater.
MODEL CHARTMODEL CHART
King Model| Volts| **Phase| Wattage| ****Lamps|
****Amps| ****Accessory| ****Product Size| Weight (Lbs)
---|---|---|---|---|---|---|---|---
RK2015-RMT-BLK| 208| 1| 1500| 1| 7.2| Remote Control| 24.5″ x 6.5″ x
5.25″| 6.68
RK2015-BLK| 208| 1| 1500| 1| 7.2| On/Off Switch
RK2415-RMT-BLK| 240| 1| 1500| 1| 6.3| Remote Control
RK2415-BLK**| 240| 1| 1500| 1| 6.3| On/Off Switch
INSTALLATION INSTRUCTIONS
TOOLS NEEDED
Pencil, Hammer, Level, Screw-Driver, Power Drill & Drill Bits A wall
mounting bracket is provide with the heater which has been specifically
designed to allow this product to be secured to a wall or a ceiling. Before
drilling any holes, check that the wall or ceiling is solid and that there are
no hidden water pipes or electric wires. The heater must be installed no less
than 1 ‘7″ from side walls and no less than 7’9″ off the floor.
Caution:
Select appropriate mounting bolts and anchors for your application.
ATTENTION!
The appliance must be installed on the solid surfaces like concrete, wood
or metal etc.
Important:
Ensure that the supply cable is well secured and that it does not come into
contact with reflector of the heater or that it does not lay inside the heated
area. The supply cable can be fixed to the metal mounting bracket behind
heater with plastic zip ties.
- This heater should be installed by a competent person, i.e. a qualified electrician.
- Always disconnected the heater from the electricity supply and allow it to cool before installation.
- For ceiling mounting, the lowest part of the heater must be located at or above a minimum height of 7’9″ from ground level, so that the heater can not be touched when in operation.
- For ceiling mounting, there must be a 7’9″‘ distance from your appliance to the ground.
- When mounted to the ceiling, there must be a distance of 1 ‘7″ between side walls and the appliance.
- Always maintain a minimum distance of 3’3″ from the appliance to people.
- The distance from the front side of the heater to materials such as wood, carton, cloth etc., must be a minimum of 3’3″.
- When mounting to a ceiling, do not position the heater at an angle more than 90° or less than 45°.
- The supply cable must be at the lower end of the heater if the heater is installed at an angle.
- Keep the supply cord away from the body of the heater which will get hot during use.
- Do not install the heater on an flammable surface.
- Observe the minimum safe distance between the heater body and flammable surfaces when mounted.
- The heater should always have a minimum clearance of 1 ‘7″ from a ceiling and adjacent walls.
- If the heater is to be used outside, a weatherproof outlet is recommended.
- Before drilling ensure that there are no wires or water pipes in the area where the heater is to be installed.
- The heater must be installed on the mounting brackets provided.
- Fasten the brackets securely to the mounting surface and the backside of the heater using the nuts and screws supplied.
- Fasten the heater securely on the brackets using the nuts and bolts supplied.
INSTALLATION ACCESSORIES
INSTALLATION ACCESSORIES LIST
1 | Bracket – Large | L shape | 2PCS |
---|---|---|---|
2 | Bracket – Small | L shape | 2PCS |
3 | Bolt | M6mm*12mm | 2PCS |
4 | Nut | M6 | 4PCS |
5 | Washer | 4PCS | |
6 | Eye Nut | M6 | 2PCS |
ATTENTION
- Always disconnect the heater from the electricity supply and allow it to cool before attempting to work on it.
- If the heater has collected dust or dirt inside the unit or around the heating element, have to unit cleaned by a qualified service agent.
- The only maintenance required is cleaning of the external surfaces of the heater.
- Do not touch the heating element with bare fingers, as residue from your hand could affect the life of the lamp. If it is accidentally touched, remove the finger marks with a soft cloth moistened with mentholated spirit or alcohol.
- Do not attempt to repair or adjust any electrical or mechanical functions on this heater.
- The heater contains no user serviceable parts. Should the product suffer damage or breakdown, contact manufacturer.
- Damaged supply cords to be replaced by the manufacturer, service agent or similarly qualified person in order to avoid hazard.
WALL MOUNT GUIDE
CAUTION:
Select the suitable screw according to the heater weight/different model.
Angle of reflector no more than 45°. The heater must be installed at least
7’9″above the floor.
WALL MOUNT INSTALLATION STEPS
-
Step 1: Mark hole locations on the mounting surface with spacing as shown.
-
Step 2: Select fasteners and anchors of appropriate type sufficient for your specific wall type (Not provided). Drill holes on your indicator marks.
Step 3: Insert wall anchors into holes.
-
Step 4: Secure wall brackets to wall using 2 screws each. Make sure fasteners are suitable for your application
-
Step 5: Secure small brackets to heater using the supplied Eye Nuts. Then insert a bolt through hole in each small bracket and begin threading a nut onto end with a few threads of engagement.
-
Step 6: Hang heater onto wall mounted brackets by inserting the bolts through the vertical slot in the bracket and then tighten nuts completely to secure in place at the desired angle
CEILING MOUNT GUIDE
CAUTION:
Select the suitable screw according to the heater weight/different model. The
heater must be installed at least 7’9″ above the floor grade
CHAIN MOUNT INSTALLLATION
- Use only noncombustible materials for suspending hangers and brackets.
- A minimum No. 2 chain with a working load limit of 115 lbs. is required.
- Secure chain to heater using the provided eye nuts as attachment points.
- Heaters must not be supported by electric supply lines and must be suspended from a permanent structure with adequate load capacity.
CAUTION:
Select the suitable screw according to the heater weight/different model.
The heater must be installed at least 7’9″ above the floor grade
INSTALLATION INSTRUCTIONS
This heater must be permanently installed and hard wired by a licensed
electrician in accordance with local electrical codes. Assembly procedure must
be performed with no electrical power to unit.
- Step 1: Check UL/CUL label on heater for proper voltage.
- Step 2: Follow supplied wiring instructions. (See wiring instructions below)
- Step 3: Heater must be mounted with reflector angled down.
- Step 4: All electrical connections must be in compliance with the National Electric Code (NEC) and local codes for outdoor wiring.
- Step 5: Use only wiring components UL/CUL listed for outdoor use with IPX4 minimum rating.
WIRING INSTRUCTIONS
The heater has provisions for standard 1 /2″ conduit fittings. The installing
electrician will need to provide the appropriate rigid metallic, flexible or
liquid tight conduit for the installation location.
- Observe local electrical code regulations.
- Remove cover plate from junction box.
- An Additional junction box may be required if more space is needed.
- Attach conduit.
- Use only copper wire suitable for 90°C.
- Replace cover plate.
INSTALLATION INSTRUCTIONS
NOTE:
You maybe required to add an additional junction box to the wiring box if
additional wires are installed.
WIRING DIAGRAMS
1500W Model
OPERATING INSTRUCTIONS
Onboard Control Functions:
- POWER SWITCH: Turns on the power, the product is standby mode display (- -);
- FUNCTION BUTTON: Press button to select heat levels (L 1-L2- standby – om
- L 1 = Level 1-Half Wattage
- L2= Level 2-Full Wattage
Remote Control Instructions for Model RK2O3O-RMT-B / RK243O-RMT-BLK / RK2O45-RMT-BLK / RK2445-RMT-BLK
- POWER BUTTON: Turns the heater On/Off.
- UP BUTTON: Increase timer and heat level.
- DOWN BUTTON: Decrease timer and heat level.
- HEAT LEVEL BUTTON: Use to adjust the heat levels (L 1-L2).
Press the Heat Level button, then use the up and down buttons (buttons 2 and
- to increase or decrease the heat level.
- TIMER BUTTON: To set the timer from 0H-24H, which is the number of hours it will run. OH will display and then adjust to the number of hours you would like to set, using the up
and down buttons.
Noted:
The heaters and their remote controls have the same frequency, so it is
possible to control several heaters with just one remote.
Inserting Batteries
Insert 2 AAA/ Alkaline type batteries into your remote control
- Flip to the backside of your remote control and pull off the battery cover. Insert the batteries in accordance with the instructions and polarity of the batteries.
- Change the batteries in the same way depicted above.
NOTICE:
Replace old batteries with the same battery type. Otherwise, your heater may
not function well. Remove batteries when heater is not used for long periods
of time to prevent leakage which may damage the remote. Do not allow water or
liquids to get into the remote control.
CAUTION:
When the appliance is not operated for a long period of time, when cleaning or
maintenance is conducted or when the location of the heater is changed, the
heater should be turned to OFF and unplugged from the electrical connection.
Periodic inspection and removal of dirt and contaminants will ensure that
equipment can be operated safely.
TROUBLE SHOOTING
- Check if the power supply cable is properly connected. If not, make necessary connections.
- Check if electricity at the main circuit breaker is working.
- Error code shows on display.
- E1 Error on display: Control unit has overheated. Turn unit off and allow to cool down for 1 hour and restart heater.
- L 1,2 shows on display, but no heat: Heat Lamp is damaged. Arrange for replacement bulb with local Dealer.
- Check if the power cord is plugged into an electrical outlet, if not, plug in.
- Check and verify the power at the main circuit breaker functioning correctly.
- Error code shows on display
- E1 Error on display: Control unit overheated. Cool down the heater for 1 hour and then restart heater.
- L 1,2 shows in display, but no heat: Bulb is damaged. Arrange for replacement bulb with local Dealer.
MAINTENANCE
ATTENTION!
Careful and regular maintenance of your heater is important to achieve long,
efficient operation of your appliance.
- Check the Reflector and IR-Filament at least once a month. If cleaning is necessary, follow the below cleaning and maintenance instructions.
- Check more frequently if the unit is installed in a dusty environment.
- Visually inspect the Reflector, Wire and Frame for any damage while cleaning the appliance.
- Check the Power Cord and Plug visually while cleaning the appliance. In case of deformation, consult to your technical service.
CLEANING
Regular and careful cleaning helps your infrared heater operate efficiently
for many years of trouble-free operation. To clean your heater follow steps
below:
- Unplug or disconnect the power cord before cleaning your appliance.
- Make sure the heater is cool before continuing.
- To keep the heater clean, the outer shell maybe cleaned with a soft, damp cloth. You may use a mild detergent if necessary. After cleaning, dry the unit with a soft cloth. (CAUTION: DO NOT let liquids enter the heater).
- DO NOT use alcohol, gasoline, abrasive powders, furniture polish or rough brushes to clean the heater. This may cause damage or deterioration to the surface of the heater.
- DO NOT immerse the heater in water
- Wait until the heater is completely dry before use.
Storage:
Store the heater in a cool, dry location when not in use to prevent dust
and dirt build up. Use packaging carton to store.
RECYCLING
At the end of the electrical products useful life it should not be disposed
of with household waste. Please recycle at an appropriate recycling center.