SonicOS 7.1
Device Log
Administration Guide
About SonicOS
This guide is a part of the SonicOS collection of administrative guides that describes how to administer and monitor the SonicWall family of firewalls. SonicOS provides network administrators the management interface, API (Application Program Interface), and the Command Line Interface (CLI) for firewall configuration by setting objects to secure and protect the network services, to manage traffic, and to provide the desired level of network service. This guide focuses on how to configure the device settings, capture all log activities, configure log files and report the logs on the Sonicwall security appliances
Working with SonicOS
SonicOS provides a web management interface for configuring, managing, and monitoring the features, policies, security services, connected devices, and threats to your network. SonicOS runs on top of SonicCore, SonicWall’s secure underlying operating system.
The SonicOS management interface facilitates:
- Setting up and configuring your firewall
- Configuring external devices like access points or switches
- Configuring networks and external system options that connect to your firewall
- Defining objects and policies for protection
- Monitoring the health and status of the security appliance, network, users, and connections
- Monitoring traffic, users, and threats
- Investigating events
SonicWall offers two different modes of operation in SonicOS; the modes differ mainly in the areas of policy, object configuration and diagnostics.
- Policy Mode provides a unified policy configuration work flow. It combines Layer 3 to Layer 7 policy enforcement for security policies and optimizes the work flow for other policy types. This unified policy work flow gathers many security settings into one place, which were previously configured on different pages of the management interface.
- Classic Mode is more consistent with earlier releases of SonicOS; you need to develop individual policies and actions for specific security services. The Classic Mode has a redesigned interface.
This table identifies which modes can be used on the different SonicWall firewalls:
Firewall Type | Classic Mode | Policy Mode | Comments |
---|---|---|---|
TZ Series | yes | no | The entry level TZ Series, also known as desktop |
firewalls, deliver revamped features such as 5G readiness, better connectivity
options, improved threat, SSL and decryption performance that address HTPPS
bandwidth issues; built-in SDWAN, and lawful TLS 1.3 decryption support.
NSa Series| yes| no| NSa firewalls provide your mid sized network with
enhanced security . They are designed
specifically for businesses with 250 and up. it can provide cloud-based and
on-box capabilities like TLS/SSL decryption and inspection, application
intelligence and control, SD-WAN, real-time visualization, and WLAN
management.
NSsp 10700, NSsp 11700,
NSsp 13700| yes| no| The NSsp platforms high-end firewalls that deliver the
advanced threat protection and fast
speeds that large enterprises, data centers, and service providers need.
NSsp 15700| no| yes| The NSsp 15700 is designed for large distributed
enterprises, data centers, government agencies and services providers. It
provides advanced threat protection like Real-Time Deep Memory Inspection,
multi-instance firewall configuration, and unified policy creation and
modification, with scalability and availability.
NSv Series| yes| yes| The NSv series firewalls offers all the security
advantages of a physical firewall with the
operational and economic benefits of virtualization. The NSv firewalls can
operate in
either Policy Mode or Classic Mode. You can switch between modes, but some
configuration
information from extra interfaces is removed.
In addition to the management interface, SonicOS also has a full-featured API
and a CLI to manage the firewalls.
For more information, refer to:
- SonicOS 7.1 API Reference Guide
- SonicOS Command Line Interface Reference Guide
SonicOS Workflow
When working with SonicWall products, you can use the following workflow as a guide for setting up your security solution.
You begin your planning as you start making your purchasing decisions. Your
sales partners can help you assess your environment and make recommendations
based on the kinds of security services you need. You can learn more about
SonicWall products by reviewing product information and solutions. After
selecting the solution, you can schedule your implementation.
After planning and scheduling your solution, you begin setting up the
firewalls. The Getting Started Guides for your products can help you begin
setting up the pieces to your solution. The getting started guides are
designed to help you install the firewall to a minimal level of operation.
Before performing any detailed configuration tasks described in the SonicOS
Administration Guides, you should have your firewall set up and basic
operation validated.
The configuration block of the workflow refers to the many tasks that combine
to define how your firewall is integrated into your security solution and how
it behaves when protecting your environment. Depending on the features of your
security solution, this task can be quite complex. The System Administration
Guides are broken into the key command sets and features. Some documents may
be used for all solutions, but others may be used use only if you integrated
that feature into your solution. For example, High Availability or Wireless
Access Points are not necessarily used by all customers. More information
about a feature’s workflow is presented in the feature administration guide.
Refer to the specific Administration Guide for a SonicOS feature for more
information.
Configuration tends to be a one-time activity, although you might make minor
adjustments after monitoring performance or after diagnosing an issue. The
configuration activity can be broken down into the more detailed flow as the
following figure shows. This also mirrors the key functions that are listed
across the top of the management interface.
There is some flexibility in the order in which you do things, but this is the general work-flow you would follow when configuring your firewall. Start by defining the settings on the firewall. Next you set up the system and other devices that your firewall is connected to, and you can choose to implement High Availability when done. After your device, network, and system is configured, you should define the objects that you want to monitor. Then you use those objects to define the policies that protect your network. The final step to preparing your setup is to validate the user authentication.
How to Use the SonicOS Administration Guides
The SonicOS Administration Guide is a collection of guides that detail the
features represented by each of the main menu items in the management
interface. Within each guide, you can find topics covering commands in that
menu group, along with procedures and in-depth information. The exceptions are
the SonicOS 7.1 Monitor Guide and the SonicOS 7.1 Objects Guide which combine
the topics for each of those functions into a single book.
To help you understand how the books align with the features and commands, the
following figure shows the books organized like the SonicWall management
interface.
The SonicOS Administration Guides, along with related documentation, such as the getting started guides, are available on the https://www.sonicwall.com/support/technical-documentation/.
Guide Conventions
These text conventions are used in this guide:
NOTE : A NOTE icon indicates supporting information.
IMPORTANT : An IMPORTANT icon indicates supporting information.
**TIP: A TIP icon indicates helpful information.
CAUTION : A CAUTION icon indicates potential damage to hardware or loss
of data if instructions are not followed.
WARNING** : A WARNING icon indicates a potential for property damage,
personal injury, or death.
Convention | Description |
---|---|
Bold text | Used in procedures to identify elements in the management interface |
like dialog boxes, windows, screen names, messages, and buttons. Also used for
file names and text or values you are being instructed to select or type into
the interface.
Function | Menu group >
Menu item| Indicates a multiple step menu choice on the user interface. For
example, NETWORK | System > Interfaces means to select the NETWORK functions
at the top of the window, then click on System in the left navigation menu to
open the menu group (if needed) and select Interfaces to display the page.
Code| Indicates sample computer programming code. If bold, it represents text
to be typed in the command line interface.
About Device
SonicOS comes equipped with several features to configure Device. Basic Device information can be viewed in the Dashboard (navigate to HOME > Dashboard). The other Device configuration tools are group under the Device option as follows.
- Settings – To manage the Administration settings.
- High Availability – To view the status, configure, support licenses and to monitoring.
- Users – To view status of local and guest users.
- AppFlow – To configure Flow Reporting and AppFlow Agent.
- Log – To captures all log activities, configure log files and report the logs.
- Diagnostics – To configure system diagnostics.
Device Log Introduction
The Device option is a collection of setup options you can use to configure
the device settings, capture all log activities, configure log files and
report the logs.
The commands on the left shows differ kinds of options. Once an option is selected, you can view different aspects of the data by selecting the different tabs. More information on each of the options are provided in the following chapters:
Settings
This section provides configuration tasks to enable you to categorize and customize the logging functions on your SonicWall security appliance for troubleshooting and diagnostics.
The Device > Log > Settings page displays logging settings in a series of columns and allows you to configure the logging and alert levels, edit attributes of all categories, groups, and reset all event counts. You can filter the entries to limit the data display to only those events of interest. You can select storage options on appliances with built-in or flexible storage components, and you can import and save logging templates.
Filtering the Base Setup View
You can filter the log data by using the Filter icon on the Device > Log > Settings page to filter at the category, group, or event level. This provides a way to filter the display of Log > Settings to make it easier to view settings of selected events. The Filter View in this context only allows “Name, Priority, ID, OIDName and TrapType.” Enter the Name, Priority, ID, OIDName or TrapType and click Find to filter the log data. Click Reset to clear the filter applied.
Log data is displayed on the Monitor > Logs > System Logs page that has its own Filter View that is more granular. You can navigate to the Logs > System Logs page quickly by clicking View Logs in the top row of the Log > Settings page. For more information, see SonicOS 7.1 Monitor Guide.
Configuring the Logging and Alert Levels
This section provides information on configuring the level of priority of log
messages that are captured, and the corresponding alert messages that are sent
through email for notification.
Alert emails are sent when enabled and an email address is configured.
Specifically:
- Select the Enable option Send Events as Email Alerts in the Edit Log Event dialog launched from the table on the Log > Settings page.
- There is an email address configured in Send Alerts to E-mail Address in the Log > Automation page or in one of the following Edit dialogs launched from the table on Log > Settings page.
- Edit Log Category dialog
- Edit Log Group dialog
- Edit Log Event dialog
About SonicOS
The Logging Level provides a way to use the Event Priority setting of the
event to filter for log generation.
Events with equal or greater priority are logged. Events with a lower priority
are not logged. This enables you to filter out lower-level priorities to
prevent them from being logged. This Logging Level filtering is done at the
beginning of logging the event, before any other filtering settings are
applied. The Logging Level filtering affects which logs are actually stored in
the Log database (and storage), unlike the Filter icon that only affects the
display of those logs.
****TIP: While the Event Priority for each event has a factory default value,
the Edit dialogs allow the Event Priority to be customized as needed on the
Category level, Group level, or individual Event level. By changing the Event
Priority for selected events, administrators can include events that are
otherwise filtered out because of the Logging Level setting. For example, a
factory default Debug event can be set to have an Event Priority of Warning so
that it is included in the logs when Logging Level is set to Warning. On the
Log > Settings page, you can set the baseline logging level to be displayed on
the Monitor > Logs > System Logs page. The following logging levels are
available for selection, from highest to lowest:
- Emergency
- Alert
- Critical
- Error
- Warning
- Notice
- Inform
- Debug
The default level is Inform.
To set the logging level:
- Navigate to the Log > Settings page.
- From the Logging Level drop-down menu, select the logging level you want.
All events with Event Priority equal to or higher than the selected entry are logged. For example, if you select Error as the Logging Level, all messages with Event Priority of Error, Critical, Alert, and Emergency are logged.
NOTE : To display all events, select Debug as the logging level.
Setting the Alert Level
The Alert Level provides a way to use the Event Priority setting of the event
to filter for email alerts generation.
It is assumed that the event has already been included after applying the
Logging Level filter and after applying the Frequency Filter Interval
configured for the Send Events as E-mail Alerts option in the Edit dialogs.
For Alert Level filtering, only events with an Event Priority of Warning or
higher are included.
****TIP: While the Event Priority for each event has a factory default value,
the Edit dialogs allow the Event Priority to be customized as needed on the
Category level, Group level, or individual Event level. By changing the Event
Priority for selected events, administrators can include events that are
otherwise filtered out because of the Logging Level setting. For example, a
factory default Debug event can be set to have an Event Priority of Warning so
that it is included in the logs when Logging Level is set to Warning.
Email alerts are sent to the email address configured in Send Alerts to E-mail
Address in the Log > Automation page or, if set, configured in one of the Edit
dialogs launched from the table on the Log > Settings page. Events with an
alert level equal to or greater than the configured Alert Level are sent to
the specified email address. No email alerts are sent for events with a lower
alert level. This enables you to filter out lower-level email alerts to reduce
the actual emails transmitted.
The following alert levels are available for selection:
- Emergency
- Alert
- Critical
- Error
- Warning
The default value is Alert.
To set the alert level:
- Navigate to the Log > Settings page.
- From the Alert Level drop-down menu, select the alert level you want.
All events with Event Priority equal to or higher than the selected Alert Level are also emailed. For example, if you select Error as the Alert Level, all messages all messages with Event Priority of Error, Critical, Alert, and Emergency are emailed.
****TIP: To email alerts for events of all alert levels, select Warning as the Alert Level.
About Other Top Row Buttons
The Logging Level and Alert Level configurations are described previously. This section provides a summary of the other buttons that appear above the table on the Device > Log > Settings page.
Edit Attributes of All Categories
Clicking the Edit All Categories Attributes button above the table launches
the Edit Attributes of All Categories dialog. This dialog enables you to set
the attributes for all events in all categories and groups at once.
For information about this procedure, refer to Configuring Event Attributes
Globally.
Reset All Event Counts
Click the Reset button to set all the event counters to 0.
Save Template
Save Template displays the Save to Custom Template pop-up dialog so you can
export the current configured Log Settings to the Custom template. The dialog
also lets you enter a description for the Custom template.
Only the Custom template can be modified and saved, and there is only one custom template. Each time the custom template is saved, the old custom template is overwritten.
Import Template
Clicking on the Import From Template button displays the Import from Log
Category Template dialog that allows you to select and import one of these
templates:
- Default
- Minimal
- Analyzer / Viewpoint / GMS
- Firewall Action
- Custom
You can select Custom if you previously saved a template using Save As Custom. If there is no user template saved, Custom option cannot be selected.
CAUTION : The imported template overwrites individual settings. Normally,
production environments would not set all Categories/Groups/Events to have
exactly the same settings. Before doing this, be sure to save your current
configuration using the Save Template option, so that the previous settings
can be restored when a mistake is made by using Import Template > Custom.
Also, factory default settings can be restored using Import Template >
Default.
NOTE : The Default, Minimal, and Analyzer/Viewpoint/GMS templates are
default templates defined in SonicOS.
Default Template
The Default template restores all log event settings to the SonicOS default
values for each of these log fields:
- Event Priority
- Display Events in Log Monitor
- Send Events as E-mail Alerts
- Report Events through Syslog
- Include Events in Log Digest
- Frequency Filter Interval
- Send Log Digest to E-mail Address
- Send Alerts to E-mail Address
- Show Events using Color
Minimal Template
The Minimal template keeps the generated logs at a minimum level, while still
providing sufficient information about the most important events on the
firewall. The minimal template modifies the capture filters to allow only
high-priority events to be logged. Most non-critical events are filtered out.
The capture filters are modified for these fields: GUI, Alert, Syslog, and
Email.
NOTE : Only the capture filters are modified; the Frequency Filter
Interval settings are left as is.
Analyzer/ViewPoint/GMS Template
The Analyzer/Viewpoint/GMS template ensures that the firewall works well with
Reporting Software server settings (Analyzer, Viewpoint, and/or GMS server).
All related events are configured to meet the server requirements.
All configurations are limited to the Report Events via Syslog option and its
associated Frequency Filter Interval. Events critical to the reporting
function of Analyzer, Viewpoint, and GMS has these fields set to the
recommended factory-default values:
- Report Events via Syslog
- Frequency Filter Interval for Syslog
Firewall Action Template
The Firewall Action template is based on the Analyzer/ViewPoint/GMS Template.
In addition to the settings that the Analyzer/Viewpoint/GMS Template provides,
it enables logs that report dropped packets.
Custom Template
The Custom template is created by clicking Save Template. Each time you click
Save Template, the previous Custom template is overwritten. Importing it
brings back the saved settings.
View Logs
The View Logs button in the top row takes you to the Monitor > Logs > System
Logs page where you can view the log data. For more information about logs,
refer to SonicOS 7.1 Monitor Guide.
About the Log Settings Base Setup Table
Following are columns present in the Log Settings page.
Category Column
The Category column of the Log Settings table has three levels:
- Category, first and highest level of the tree structure
- Group, the second level
- Event, the third level
Clicking the triangle icon to the left of the category or group name expands or collapses the category or group contents:
Color Column
The Color column shows the color with which the event is highlighted in the
Monitor > Logs > System Logs. To change the color of the event, click the Edit
icon for the event.
ID Column
The ID column shows the ID number of the event. The ID for a particular
message is listed in the SonicOS Log Events Reference Guide.
The ID number of the event is the same value used in Syslog as the m= message
ID and can also be found in the Event ID column of Log Event Message Index
table in the SonicOS Log Events Reference Guide.
NOTE : The ID number is only displayed on the event level that can be
either second or third level.
Priority Column
CAUTION : Changing the Event Priority could have serious consequences.
Changing the Event Priority on the Group or Category level also changes all
Events under that Group or Category to the same Event Priority value.
Modifying the Event Priority affects the Syslog output for the tag “pri=” as
well as how the event is treated when performing filtering by Logging Level or
Alert Level.
Setting the Event Priority to a level that is lower than the Logging Level
causes those events to be filtered out. Also, as SonicWall GMS ignores
received Syslogs that have a level of Debug, heartbeat messages and reporting
messages must have a minimum Event Priority of Inform.
The Priority column shows the severity or priority of a category, group, or
event. For events, a drop-down menu lists the selectable priorities. For
categories and groups, the priorities are listed in the dialog when you click
Configure at the end of the row.
The available priorities are:
- Emergency
- Alert
- Critical
- Error
- Warning
- Notice
- Inform
- Debug
GUI Column
The GUI column indicates whether this item is displayed in the Monitor > Logs
System Logs. The checkbox displayed for an Event in this column corresponds to the Enable checkbox setting for the Display Events in Log Monitor option in the Edit Log Event dialog.
Display of categories and groups is shown with a To show or hide indicator. To change the display for:
- An event, select or clear the checkbox in the column.
- Categories and groups, click the Edit icon in the column to display the Edit Log Category or Edit Log Group dialog.
Alert Column
The Alert column indicates whether an Alert message is sent for this event,
group, or category. The checkbox displayed for an Event in this column
corresponds to the Enable checkbox setting for the Send Events as Email Alerts
option in the Edit Log Event dialog.
The checkbox or indicator for Alert applies to both sending of an email per-
event and to the generation of an SNMP Trap (if SNMP configuration is
enabled). For E-mail Alerts, the E-mail Address is either the global value set
in the Send Alerts to E-mail Address field in the Device > Log > Automation >
Email Settings page or the custom address configured in the Send Alerts to
E-mail Address field in one of the Edit dialogs launched from the table on the
Log > Settings page.
Whether the message is sent is shown with a To show or hide indicator. To
change whether the Alert message is sent for:
- An event, select or clear the checkbox in the column.
- Categories and groups, click the Edit icon in the column to display the Edit Log Category or Edit LogGroup dialog.
Syslog Column
The Syslog column indicates whether the event, group, or category is sent to a
Syslog server. The checkbox displayed for an Event in this column corresponds
to the Enable checkbox setting for the Report Events via Syslog option in the
Edit Log Event dialog.
Whether the event, group, or category is sent is shown with a To show or hide
indicator. To change whether the event, group, or category is sent for:
- An event, select or clear the checkbox in the column.
- Categories or groups, click the Edit icon in the column to display the Edit Log Category or Edit Log Group dialog.
Internet Protocol Flow Information Export (IPFIX) Column
The IPFIX column indicates whether IPFIX is enabled for log events. The
checkbox displayed for an Event in this column corresponds to the Enable
checkbox setting for the Report Events via IPFIX option in the Edit Log Event
dialog.
System logs can be sent to an external server through IPFIX packets and then
saved into the database on the disk. The logs only include the ones reported
without connection cache.
Whether the event, group, or category has IPFIX enabled is shown with a To
show or hide indicator. To enable/disable IPFIX for:
- An event, select or deselect the checkbox in the column.
- Categories or groups, click the Edit icon in the column to display the Edit Log Category or Edit Log Group dialog.
Email Column
The Email column indicates whether the log is emailed to the configured
address. The checkbox displayed for an Event in this column corresponds to the
Enable checkbox setting for the Include Events in Log Digest option in the
Edit Log Event dialog. The Log Digest is further configured in the Device >
Log > Automation > Email Settings page in the E-mail Log Automation section,
in the Send Log to E-mail Address and Send Log (Daily, Weekly, When Full)
options.
For events, these checkboxes are configurable in the column. For categories or
groups, Email is configured in the Edit Log Group or Edit Log Category dialogs
that appear when you click Edit at the end of the row.
Event Count Column
The Event Count column shows the count of events by:
- Event level — The number of times that this event has occurred.
- Group level — The total events that occurred within the group.
- Category level — The total events that occurred within the category.
By hovering your mouse over an event count, a pop-up message displays the count of events dropped for these reasons:
- Overflow – count of events dropped because they cannot be enqueued for logging.
- GUI Filter – count of events dropped because the checkbox for Display Events in Log Monitor is disabled, or, if enabled, the event was dropped because of GUI Frequency Filter Interval.
- Alert Filter – count of events dropped because the checkbox for Send Events as E-mail Alerts is disabled, or, if enabled, the event was dropped because of Alert Frequency Filter Interval.
- Syslog Filter – count of events dropped because the checkbox for Report Events via Syslog is disabled, or, if enabled, the event was dropped because of Syslog Frequency Filter Interval.
- Trap Filter – count of events dropped because the checkbox for Report Events via SNMP Trap is disabled, or, if enabled, the event was dropped because of Trap Frequency Filter Interval.
- IPFIX Filter – count of events dropped because the checkbox for Report Events via IPFIX is disabled, or, if enabled, the event was dropped because of IPFIX Frequency Filter Interval.
- E-mail Filter – count of events dropped because the checkbox for Include Events in Log Digest is disabled, or, if enabled, the event was dropped because of E-mail Frequency Filter Interval.
- Priority – count of events dropped because the Event Priority was excluded from Logging Level.
- Syslog Event Rate – applies only to Syslogs dropped when Event Rate Limiting is enabled in the Device > Log > Syslog page, and Maximum Events Per Second exceeded the configured threshold.
- Syslog Data Rate – applies only to Syslogs dropped when Data Rate Limiting is enabled in the Log > Syslog page, and Maximum Bytes Per Second exceeded the configured threshold.
Edit and Reset Count Icons
The Edit and Reset Event Count icons appear at the end of each row.
The Edit icon launches the Edit Log Event, Edit Log Group, or Edit Log
Category dialog.
You can configure all of the attributes for an event, group, or category.
The Reset Event Count icon resets the event counter for an event, a group, or
a category, and the event counters of higher levels are recalculated. To reset
all counters, use Reset Event Count above the table on the Device > Log >
Settings page, as described in Reset All Event Counts.
Configuring Event Attributes Globally
NOTE : For information about configuring event attributes selectively,
see Configuring Event Attributes Selectively.
Clicking the Edit All Category Attributes icon above the table launches the
Edit Attributes of All Categories dialog. This dialog enables you to set the
attributes for all events in all categories and groups at once.
These global attributes can be modified:
- Event Priority
- Inclusion of events in Log Monitor, Email, and Syslog
- Frequency Filter Interval
- Email settings
- Font color when displayed in Log Monitor
One practical use of this global setting is to force ALL events to use the
same Syslog Server Profile (GMS uses Profile 0 only), send Log Digest to the
same E-mail Address, and send Alerts to the same E-mail Address.
To edit the Category attributes globally:
-
Navigate to the Device > Logs > Settings page.
-
Click the Edit All Category Attributes icon. The Edit Attributes of All Categories pop-up dialog appears. NOTE : Enable is solid green when all categories, groups, and/or events are enabled, white when all are disabled, and semi-solid when they are mixed (some enabled, some disabled).
As this configuration is for all categories, you have to explicitly set the option to “all enabled” by clicking the icon until it is solid green, or to set the option to “all disabled” by clicking the icon until it is white. To configure a single event to be different from the rest of its group or category, you must go into the individual event setting configuration. If you do this, the icon is semi-solid.
When the fields display Multiple Values, different values have been specified for one or more category, group, or event. To view the individual settings, refer to Configuring Event Attributes Selectively. To change the setting from Multiple Values into one value for all categories, groups, or events while in the Edit Attributes of All Categories dialog, verify that the option was enabled so the field can be accessed for entering the new value. If the option is disabled, the field is dimmed and inaccessible.
CAUTION : The changes are saved and overwrite individual settings. Normally, production environments would not set all Categories/Groups/Events to have exactly the same settings.
Before doing this, be sure to save your current configuration using the Save Template option, so that the previous settings can be restored if a mistake is made by using Import Template > Custom. Also, factory default settings can be restored using Import Template > Default. -
From the Event Priority drop-down menu, select the priority that you want.
CAUTION : Changing the Event Priority globally uses the same value for all Events. Modifying the Event Priority affects the Syslog output for the tag “pri=” as well as how the event is treated when performing filtering by Logging Level or Alert Level. Setting the Event Priority to a level that is lower than the Logging Level causes those events to be filtered out. Also, as GMS ignores received Syslogs that have a level of Debug, heartbeat messages and reporting messages must have a minimum Event Priority of Inform.
TIP : The following Frequency Filter Interval fields enable you to specify how many events of the same Event ID to log per time interval. Note that having the same Event ID does not mean that the event is a duplicate because the message itself might contain different information such as source/destination IP addresses, and so on. The filtering is done based on Event ID only. The range for these intervals is 0 to 86400 seconds.
TIP : The different options are independent of each other, and you can enable any combination of them and set different frequencies of generation for them. For example, you might want an event message emailed to you, but it is not shown in the Monitor > Logs > System Logs page. When GMS is enabled, however, care must be taken when modifying event attributes so events used to generate reports are not incorrectly filtered out. Explicit modification of individual events are saved even if used for GMS. Before making any changes, save current Log settings using Save Template.
This way, should a mistake be made, the previous settings can be restored using Import Template > Custom. As a last resort, the GMS settings can be restored using Import Template > Analyzer/Viewpoint/GMS. -
If you want to display the log events in the Monitor > Logs > System Logs page, select the Enable icon for the Display Events in Log Monitor option.
• In the Frequency Filter Interval field for Display Events in Log Monitor, enter the number of seconds that should elapse before allowing the same event to be logged and displayed again when that event occurs one after the other. The range is 0 to 86400.
For example, if you set this value to 60 seconds, then when the event Connection Closed first happens at 1:15 p.m., the next Connection Closed event to be displayed must occur at least 60 seconds after the first one. Any Connection Closed event occurring within the 60 seconds interval is not displayed. -
If you want to send events as E-mail Alerts, select the Enable icon for the Send Events as E-mail Alerts option.
• In the Frequency Filter Interval field for Send Events as E-mail Alerts, enter the number of seconds that should elapse before allowing the same email event to be sent when that event occurs one after the other. The range is 0 to -
For example, if you set this value to 60 seconds, then when an E-mail Alerts first happens at 1:15 p.m., the next E-mail Alerts for the same event is not sent until 60 seconds after the first one.
Alerts for the same event occurring within the 60 seconds interval are not emailed. -
If you want to report events through Syslog, select the Enable icon for the Report Events via Syslog option.
• In the Frequency Filter Interval field for Report Events via Syslog, enter the number of seconds that should elapse before allowing the same Syslog messages to be sent when that event occurs one after the other. The range is 0 to 86400.
For example, if you set this value to 60 seconds, then when a Syslog message is first reported at 1:15 p.m., the next Syslog message for the same event is not sent until 60 seconds after the first one. Syslog messages for the same event occurring within the 60-second interval are not sent. -
To send the Syslogs to a particular Syslog server group, enter the group’s ID in the Use this Syslog Server Profile field. The default is 0.
-
If you want to report events through IPFIX, select the Enable icon for the Report Events via IPFIX option.
• In the Frequency Filter Interval field for Report Events via IPFIX, enter the number of seconds that should elapse before allowing the same events to be reported through IPFIX when events occur one after the other. The range is 0 to 86400.
For example, if you set this value to 60 seconds, then when an event reported through IPFIX first happens at 1:15 p.m., the next report for the same event is not sent until 60 seconds after the first one. Reports to IPFIX for the same event occurring within the 60 seconds interval are not sent. -
If you want to include the events in the Log Digest, select the Enable icon for the Include Events in Log Digest option. The Log Digest is a chronological collation of events.
-
If you enabled Include Events in Log Digest, do one of the following for Send Log Digest to E-mail Address:
• If you want to use the same email address that is entered in the Log > Automation page even when you change other values in this dialog, select Leave Unchanged. This option is enabled by default.
NOTE: If this option is enabled, it is important to verify the email address configured in the Send Log Digest to Email Address field is correct.
• To change the email address, clear the Leave unchanged option and enter a new address in the now-active field.
TIP: An email alert is one email sent for each event occurrence as soon as that event has occurred. A Log Digest, on the other hand, is a chronological collation of events sent as a single email in digest format. Because it is a summation of events, the event information time period is a mix of older and newer events. -
If you want to receive alerts through email based on the global settings in this dialog, do one of the following for Send Alerts to E-mail Address:
• If you want to use the same email address that is entered in the Log > Automation page even when you change other values in this dialog, select Leave color settings unchanged. This option is enabled by default.
•To change the email address, clear the Leave color settings unchanged option and enter a new address in the now-active field.
12. Click Save.
Configuring Event Attributes Selectively
NOTE: For how to configure event attributes globally, see Configuring
Event Attributes Globally.
On the Log > Settings page, the columns show the main event attributes that
can be configured on different levels: category, group, or per event.
NOTE: The Edit Log pop-up dialogs might look slightly similar, but the
effect of each varies in scope.
- Edit Log Category dialog modifies settings for a category and all groups that belong to the same category and, consequently, all events in that category.
- Edit Log Group dialog modifies settings for a group and all events that belong to that group.
- Edit Log Event dialog modifies settings for one specific event.
NOTE : Enable for the columns is green when all are enabled, white when all are disabled, and semi-solid when they are mixed (some enabled, some disabled).
As this configuration is for all categories, you have to explicitly set the option to “all enabled” by clicking the icon until it is solid green, or to set the option to “all disabled” by clicking the icon until it is white. To configure a single category, group, or event to be different, you must go into the individual dialog or event setting. If you do this, the icon is semi- solid.
You can enable or disable a column. In the rows for categories and groups, the
enable indicators are gray (enabled, disabled, and mixed) and cannot be
changed except through the Edit Log Category or Edit Log Group dialogs.
The rows for events contain checkboxes for enabling (√) or disabling () the
event instead of indicators.
Configuring Event Attributes by Category
Any changes done at the category level apply to all groups and all events
within the selected category.
To set the Event Attributes by category level:
- In the Log > Settings page, click the Edit icon in the right-most column of the row with the category you want to edit. The Edit Log Category dialog for that category is displayed.
- Follow the steps in Configuring Event Attributes Globally.
Configuring Event Attributes by Group
Setting the Event Attributes by group level allows the modification of
settings on a smaller scale within a selected category. Any changes done to
the group apply to all events that belong only to the selected group.
To set the Event Attributes by group level:
- In the Log > Settings page, click the arrow on the left to expand the category that contains the group you want to edit.
- Click the Edit icon in the right-most column of the row with the group you want to edit. The Edit Log Group dialog for that group is displayed.
- Follow the steps in Configuring Event Attributes Globally.
Configuring Event Attributes by Event
The most granular level, the event level, allows the Event Attributes columns
to be directly modified by expanding the selected category into groups, then
expanding the selected group into individual events within that group. Any
changes done to the event apply to just that event within the selected group.
To set the Event Attributes by event level:
- In the Log > Settings page, click the arrow on the left to expand the category that contains the group with the event you want to edit.
- Click the arrow on the left to expand the group that contains the event you want to edit.
- Click the Edit icon in the right-most column of the row with the event you want to edit. The Edit Log Event dialog for that event is displayed.
- Follow the steps in Configuring Event Attributes Globally.
About Filename Logging
The Security Services > Application Control group provides the Filename
Logging event. Application Control Filename Logging allows the administrator
to be notified of each filename or URIs of interest that Application Control
has explicitly identified as it processes packets or flows.
The notification uses the Log mechanism where the output can be shown in
several message formats, such as on the Monitor > Logs > System Logs page or
by Syslog. For Syslog, the message-id for an Application Control Filename Log
is 1574 and it has a message template of Filename: %s, where the value
substituted for %s can be a filename or URI identified by Application Control.
Filename Logging events can occur when the following requirements are met:
- Enable App Control – Application Control is enabled per zone from the Object > Match Objects > Zones page and globally on the Policy > Rules and Policies > App Control.
- Enable Filename Logging – Filename Logging is enabled on the Log > Settings page.
- Logging is enabled for the App Control Filename Logging event id=1574 – Enable GUI or Syslog with appropriate filtering on the Log > Settings page.
Filename Logging works with the following protocols:
- HTTP
- FTP
- NetBios/CIFS
- SMTP
- POP3
- IMAP
Gateway Anti-Virus does not need to be enabled.
With HTTP, if the server response does not have a filename in its headers, the
last portion of the URL that the client requested is used.
If the entire filename cannot be captured because of any reason, (for example,
the filename was too long or it straddles multiple packets or any other
reason), the prefix portion that was captured is logged and an asterisk is
appended to it in the log entry.
Syslog
Syslog and NetFlow are two different technologies that serve different
purposes. Syslog is a logging protocol used to collect and store log messages
from devices on a network, while NetFlow is a network protocol used to collect
and analyze network traffic data.
When it comes to the usage of both technology, whether to use Syslog or
NetFlow depends on the specific needs and requirements. Both technologies can
be useful for different purposes, and it may be beneficial to use both in
combination to gain a comprehensive view of network activity.
Here are some potential benefits of using Syslog over NetFlow:
Benefits of Syslog over NetFlow
Syslog | NetFlow |
---|
Syslog is widely supported by a variety of devices and systems, making it a
flexible and universal logging solution.| NetFlow provides more detailed and
granular information about network traffic, including
source and destination IP addresses, port numbers, and protocol types. This
can be useful
for identifying patterns and trends in network usage, and for troubleshooting
performance
issues.
Syslog can be configured to send log messages to a central server, allowing
for easy storage and centralized management of log data.| NetFlow data can be
analyzed in real-time, allowing network administrators to quickly identify and
respond to potential issues as they arise.
Syslog can be used to collect and store log messages from a variety of
sources, including servers, routers, switches, and other network devices.|
NetFlow is more efficient than Syslog, as it uses a standardized and
compressed format for data
transmission. This can be beneficial in environments with high volumes of
network traffic, as it can reduce the load on network devices and servers.
In addition to displaying event messages in the GUI, the SonicWall security
appliance can send the same messages to an external, user-configured Syslog
Server for viewing. The Syslog message format can be selected in Syslog
Settings and the destination Syslog Servers can be specified in the Syslog
Servers table.
SonicWall Syslog captures all log activity and includes every connection
source and destination name and/or IP address, IP service, and number of bytes
transferred. SonicWall Syslog support requires an external server running a
Syslog daemon; the UDP Protocol is configurable.
SonicWall has fully compatible Syslog viewers, such as GMS / Analyzer that can
generate useful reports based on received Syslog messages. When GMS or
Analyzer has been enabled, the destination hosts are automatically added as
one of the Syslog Servers. Other Syslog Servers can be added as needed. For
more information about adding Syslog Servers, see About Event Profiles.
NOTE : SonicWall Syslog support requires an external server running a
Syslog daemon on a UDP Portocol.
The default , but you can choose a different .
Packet data can be sent to Syslog Servers. For information on how to configure
this option, contact SonicWall Support.
About Event Profiles
By configuring events globally for all Syslog Servers, the events generated
from all the modules in the system are reported to all the configured Syslog
Servers. This generates huge amounts of Syslog traffic that might cause
issues, such as reduced performance and packet loss. Syslog Server profiling,
known as Event Profiling, allows more granular control by configuring events
by Syslog server instead of globally. Also, there can be multiple groups of
Syslog servers, with different events reported to different groups of servers.
You can specify up to 24 Event Profiles, with up to 7 Syslog Servers
configured for each Event Profile, for a maximum of 168 Syslog Servers per
firewall.
****IMPORTANT: A GMS server used for Syslog must belong to the Profile 0
group. Only Profile 0 group, therefore, can have up to 8 servers total (7
Syslog Servers and 1 GMS server).
The Event Profile is used, along with the Server Name and Port, to uniquely
identify a Syslog Server in the Syslog Server table. This allows multiple rows
to have same Name, Port combination with different Profiles.
Therefore, a Syslog Server can be a member of more than one Event Profile
group.
About Syslog Server Profiling
This feature provides the ability to configure the settings for each Syslog
server independently, instead of using the global settings for all the
servers. In previous releases, the events generated from all the modules in
the system were reported to all the configured Syslog servers. Depending on
the deployment, this generates a huge amount of Syslog traffic and can cause
performance issues or even packet loss.
With Syslog Server Profiling, the following new functionality is available:
****NOTE: Recommended maximum of 10 Syslog Servers users would use the dedicated syslog profiles allocated (exception for model NSsp 15700 Series).
- Syslog messages can be sent using different settings for different Syslog servers
- There can be multiple groups of Syslog servers
- Different events can be configured to be reported to different groups of Syslog servers
All the settings in the Log > Syslog page except Enable NDPP Enforcement for
Syslog Server can be configured independently for each row in the Syslog
Servers table. This allows Syslog messages to be rendered with different
settings for different servers, and each server can have its own Rate Limiting
options.
Enable/Disable sending of Syslog messages to a specific Syslog server. The
settings for Enhanced Syslog and ArcSight format can also be configured
individually.
All these settings can be configured from the SonicOS web interface and from
the command line interface (CLI.)
For convenience, the global settings can be used to configure all servers.
****NOTE: The Override Syslog Settings with Reporting Software Settings option has been removed. As the Syslog servers have their own independent settings, this option is no longer needed.
Using a GMS/Analytics Server for Syslog
GMS/Analytics can be enabled or disabled only on the Device > Log > Settings
page (for enabling and configuring GMS/Analytics, see SonicOS 7.1 System
Administration Guide.
When using a GMS/Analytics server for Syslog, the following restrictions
apply:
- The Event Profile must be 0.
- The Syslog Facility must be Local Use 0.
- The Syslog Format must be Default.
- The Syslog ID must be firewall.
When firewall is managed using GMS/Analytics, only the global settings can be
configured from GMS/Analytics.
So, if a global setting is changed, it affects all the servers. The settings
for an individual server cannot be configured, as GMS/Analytics does not
support those tags. When adding a new Syslog Server, therefore, only the
hostname and port can be configured; all other fields contain default values.
When GMS/Analytics is enabled, the GMS/Analytics server is added to the Event
Profile 0 group in the Syslog Servers table. It cannot be added to any other
Profile groups. The events in the GMS/Analytics group in the Device > Log >
Settings page have Profile 0 and cannot be changed. Other events can have a
different Profile.
Syslog Settings
The Device > Log > Syslog page enables you to configure the various settings
you want when you send the log to a Syslog server. You can choose the Syslog
facility and the Syslog format.
NOTE: If you are using SonicWall’s Global Management System (GMS) to manage
your firewall, the Syslog Format is set to Default and the Syslog ID is set to
firewall. Therefore, these fields are grayed-out and cannot be modified. All
other fields, however, can still be customized as needed.
To configure Syslog settings on your firewall:
-
Navigate to Device > Log > Syslog page.
-
During adding a Syslog sever, If you selected Enhanced Syslog as Syslog Formats, under the Enhanced Syslog Fields Settings, click the Configure icon. The Enhanced Syslog Fields Settings pop-up dialog displays.
-
Select the Enhanced Syslog options to log. By default, all options are selected; the Host and Event ID options are dimmed as they cannot be changed. To:
• Select all options, click Enable All.
• Deselect all options, click Disable All.
• Select only some options, either:
• Click Disable All, then select only those options to log.
• Deselect only those options to not log. -
Click Save.
-
During adding a Syslog sever, If you selected ArcSight as Syslog Formats, under the ARCSight CEF Fields Settings, click the Configure icon. ArcSight CEF Fields Settings pop-up dialog displays.
-
Select the ArcSight options to log. By default, all options are selected; the Host and Event ID options are dimmed as they cannot be changed. To:
• Select all options, click Enable All.
• Deselect all options, click Disable All.
• Select only some options, either:
• Click Disable All, then select only those options to log.
• Deselect only those options to not log. -
Click Save.
-
Select the Enable NDPP Enforcement for Syslog Server.
-
Select the Display Syslog Timestamp in UTC.
-
Click Accept.
About SonicOS
| Serial Number.
---|---
Event Profile| Profile configured for the Syslog Server.
Server Name| IP address and name of the Syslog Server.
Server Port| Port of the Syslog Server.
Server Type| Type of the Server.
Syslog Facility| Server Facility of the Syslog Server; for a list of Server
Facilities, see Syslog
Facility.
Syslog Format| Format expected by the Syslog Server:
• Default (default)
• WebTrends
• Enhanced Syslog
• ArcSight
Server ID| ID configured for the Syslog Server; default is firewall.
Enable| Indicates whether the Syslog Server is enabled and allows you to
enable or disable the sending of Syslog messages to a specific Syslog Server.
Configure| Contains the Edit and Delete icons for a Syslog Server. As a GMS
server cannot be deleted or configured through the Device > Log > Syslog page,
these two icons are dimmed.
Adding a Syslog Server
To add a Syslog server to the firewall.
-
Go to Device > Log > Syslog page.
-
Click Syslog Servers tab.
-
Click Add. The Add Syslog Server dialog appears.
-
Specify the Event Profile for this server in the Event Profile field. The minimum value is 0 (1 group), the maximum is 23 (24 groups), and the default is 0. Each group can have a maximum of 7 Syslog servers.
**** NOTE: For GMS, the Event Profile must be 0. -
Select the Syslog server name or IP address from the Name or IP Address drop-down menu. Messages from the firewall are then sent to the servers.
-
If your Syslog server does not use default port 514, type the port number in the Port field.
-
Select the Server Type from the drop-down options. select Syslog Server or Analyzer.
-
From the Syslog Format drop-down menu, select the Syslog format:
SYSLOG FORMATS Default| Default SonicWall Syslog format.
****NOTE: For GMS, the Syslog format must be Default.
---|---
WebTrends| WebTrends Syslog format. You must have WebTrends software installed on your system.
Enhanced Syslog| Enhanced SonicWall Syslog format.
ArcSight| ArcSight Syslog format. The Syslog server must be configured with the ArcSight Logger application to decode the ArcSight messages. -
The Syslog Facility might be left as the factory default. Optionally, however, from the Syslog Facility drop-down menu, select the Syslog Facility appropriate to your network:
**NOTE: For GMS, the Syslog format must be Local Use 0.
SYSLOG FACILITY
** Kernel| UUCP Subsystem| Local Use 0
---|---|---
User-Level Messages| Clock Daemon (BSP Linux)| Local Use 1
Mail System| AUTHPRV Security/Authorization
Messages| Local Use 2
System Daemons| FTP Daemon| Local Use 3
Security/Authorization Messages| NTP Subsystem| Local Use 4
Messages Generated Internally
by syslogd| Log Audit| Local Use 5
Line Printer Subsystem| Log Alert| Local Use 6
Network News Subsystem| Clock Daemon (Solaris)| Local Use 7 -
In the Syslog ID field, enter the Syslog ID. The default is firewall.
A Syslog ID field is included in all generated Syslog messages, prefixed by id=. Therefore, for the default value, firewall, all Syslog messages include id=firewall. The ID can be set to a string consisting of 0 to 32 alphanumeric and underscore characters. -
Optionally, to limit events logged and therefore, prevent the internal or external logging mechanism from being overwhelmed by log events, select Enable Event Rate Limiting.
****NOTE: Event rate limiting is applied regardless of Log Priority of individual events.
Specify the maximum number of events in the Maximum Events Per Second field; the minimum number is 0, the maximum is 1000, and the default is 1000 per second. -
Optionally, to limit events logged and therefore, prevent the internal or external logging mechanism from being overwhelmed by log events, select Enable Data Rate Limiting.
****NOTE: Data rate limiting is applied regardless of Log Priority of individual events.
Specify the maximum number of bytes in the Maximum Bytes Per Second field; the minimum is number is 0, the maximum is 1000000000, and the default is 10000000 bytes per second. This control limits data logged to prevent the internal or external logging mechanism from being overwhelmed by log events. -
To Bind To VPN Tunnel and Create Network Monitor Policy in NDPP mode:
a. Optionally, choose an interface from the Local Interface drop-down menu.
b. Optionally, choose an Interface from the Outbound Interface drop-down menu. -
Click Add.
Editing a Syslog Server
To edit a Syslog Server:
- Hover over on the Syslog Server which you want to edit and click the Edit icon. The Edit Syslog Server dialog displays.
- Follow the appropriate Step 4 through in Adding a Syslog Server.
Enabling Syslog Servers
****IMPORTANT: You can enable a GMS Syslog Server only on the Device >
Settings > Administration page; see SonicOS 7.1 System Administration Guide.
To enable a single Syslog Server:
- Select the toggle button in the Enable column.
To enable all Syslog Servers:
- 1. Select the Syslog servers and click Enable All.
Disabling Syslog Server
IMPORTANT : You can disable a GMS Syslog Server only on the Device >
Settings > Administration page; see SonicOS 7.1 System Administration Guide.
To disable a single Syslog Server:
- Deselect the toggle button in the Enable column.
To disable all Syslog Servers:
- Select the Syslog servers and click Disable All.
Deleting Syslog Servers
****IMPORTANT: You can delete a GMS Syslog Server only on the Device >
Settings > Administration page; see SonicOS 7.1 System Administration Guide.
To delete a single Syslog Server:
- Mouse over on the Syslog server which you want to delete and select the Delete icon.
To delete all Syslog Servers:
- Select the Syslog servers and click Delete All.
Automation
The Device > Log > Automation page includes settings for configuring the SonicWall to send log files using Email and configuring mail server settings.
Email Settings
This section describes the procedure for automating email dispatching. You can
also send an email of logs manually at any time.
-
Send Log to Email address – To receive the Log Digest through email, enter your email address (username@mydomain.com). After being sent, the Log Digest is cleared from the SonicWall memory. If this field is left blank, the Log Digest is not emailed.
-
Send Alerts to Email address – To be emailed immediately when attacks or system errors occur, enter your email address (username@mydomain.com) as a standard email address or an email paging service.
If this field is left blank, email alert messages are not sent. -
Send User Creation and Enablement Notification to Email Address – To be emailed immediately when a user has been created and enabled, enter your email address (username@mydomain.com). If this field is left blank, email notifications are not sent.
-
Send Log – Determines the frequency of sending Log Digest files. The options in the drop-down menu are:
-
When Full – This setting is the default.
-
Weekly – Select the day of the week the Log Digest is sent in Every drop-down menu and enter the time of day in 24-hour format in the At (24-Hour Format) field.
-
Daily – Enter the time of day the Log Digest is to be sent in 24-hour format in the At (24-Hour Format field.
-
Email Format – Select whether log emails are sent in Plain Text or HTML format or as a CSV Attachment from the drop-down menu.
-
Include All Log Information – Select to have all information included in the log report. If not selected, only readable column data is sent.
-
To view the logs, click Show Log Monitor at the bottom.
-
If finished configuring settings on this page, click Accept.
Email Audit Records Automation
Use this feature to send audit records to specific e-mail addresses
automatically on a predefined schedule.
To send audit records to specific email addresses:
-
In the Send to Email Address field, enter the email address(es) of the recipient(s) to notify.
-
In Send Audit Records, define when:
• Daily – Enter the time of day in 24-hour format in the At (24-Hour Format) field.
• Weekly – Select the day of the week in Every drop-down menu and enter the time of day in 24hour format in the At field.
• When Full – This setting is the default. -
Select Email Format:
• Plain Text
• HTML
• CSV Attachment -
To view the logs, click Show Log Monitor.
-
When all the fields are configured, click Accept.
Health Check Email Notification
The Health Check Email Notification section enables you to create a predefined email notification with a set subject and body at the times specified by the selected schedule.
To set up a Health Check Email Notification:
- From the Email Schedule drop-down menu, select a predefined schedule, Create new schedule, or Disabled.
- In the Send to Email Address field, enter the email address of the recipient(s) to notify.
- In the E-mail Subject field, enter the subject of the email. The Firewall Name is included by default. The Firewall Name is configured on Policy > Firewall, and is the appliance serial number by default.
- In the Email Body field, enter the body of email.
- To view the logs, click Show Log Monitor at the bottom..
- If finished configuring settings on this page, click Accept.
Mail Server Settings
The mail server settings allow you to specify the name or IP address of your mail server, the from Email address, and authentication method. You can also enter a POP3 server name or IP address, with username and password.
-
Mail Server (name or IP address) – Enter the IP address or FQDN of the email server used to send your log emails in this field.
****NOTE: If the Mail Server (name or IP address) is left blank, log and alert messages are not emailed. -
Advanced – The Advanced button displays the Log Mail Advanced Setting dialog.
-
Smtp port – Enter the SMTP port used for email. The default port number is 25.
-
Connection Security Method – Select a security method for the email from the drop-down menu:
-
None (default)
-
SSL/TLS
-
STARTTLS
-
Enable SMTP Authentication – Select to enable SMTP authentication for the emails, then enter the following. This option is disabled by default.
-
Username
-
Password
-
From Email Address – Enter the Email address you want to display in the From field of the message.
-
Authentication Method – You can use the default None or select POP Before SMTP.
-
POP3 Server (name or IP address) – Enter the IP address or FQDN of the email server used to send your log emails in this field.
-
Username – Enter the POP3 username.
-
Password – Enter the password for the POP3 account.
-
If finished configuring settings on this page, click Accept.
Clicking on Show Log Monitor displays you all the system logs.
FTP Log Automation
FTP log automation enables the administrator to send logs to an FTP server. It is similar to Email Log Automation in the following aspects:
- You can select text, HTML, or CSV file format
- You can select detailed or concise log information
- You can select a predefined time schedule. In addition to the defined schedule, logs are sent when the administrator clicks Restart and when the log is full.
To configure FTP log automation settings:
-
Navigate to the Device > Log > Automation page and select FTP Log Automation tab.
-
Select Send Log to FTP to enable FTP log automation. If this option is not selected, all the other options are grayed out.
-
For FTP Server, enter the IPv4 address of the FTP server.
-
For Username, enter the username for authenticating to the FTP server.
-
For Password, enter the password for the FTP server account.
-
For Directory, enter the destination directory on the FTP server. The default is logs.
-
From the Send Log drop-down menu, select the frequency for sending the logs to the FTP server.
Choose Daily, Weekly, or When Full. The default is When Full. -
Select the day of the week for sending the logs from the drop-down menu next to Every field. This is used for a Weekly schedule.
-
Select the hour and minute of the day in 24 hour format in the two fields next to the At (24-Hour Format).
The time is used for Daily and Weekly schedules. -
From the File Format drop-down menu, select one of Plain Text, HTML, or CSV Attachment as the format in which the logs are sent.
-
Select Include All Log Information to have all information included in the log report. If not selected, only readable column data is sent.
-
If finished configuring settings on this page, click Accept.
Clicking on Show Log Monitor displays you all the system logs.
Name Resolution
The Device > Log > Name Resolution page includes settings for configuring the name servers used to resolve IP addresses and server names in the log reports.
The SonicWall network security appliance uses a DNS server or NetBIOS to resolve all IP addresses in log reports into server names. It stores the names/address pairs in a cache, to assist with future lookups. You can clear the cache by clicking Reset Name Cache button.
Selecting Name Resolution Settings
The firewall appliance can use DNS, NetBIOS, or both to resolve IP addresses
and server names.
In the Name Resolution Method list, select:
- None: The security appliance does not attempt to resolve IP addresses and Names in the log reports.
- DNS: The security appliance uses the DNS server you specify to resolve addresses and names.
- NetBIOS: The security appliance uses NetBIOS to resolve addresses and names. If you select NetBIOS, no further configuration is necessary.
- DNS then NetBIOS: The security appliance first uses the DNS server you specify to resolve addresses and names. If it cannot resolve the name, it tries again with NetBIOS.
Specifying the DNS Server
You can choose to specify DNS servers, or to use the same servers as the WAN
zone.
-
Select Specify DNS Servers Manually or Inherit DNS Settings Dynamically from WAN Zone. The second choice is selected by default.
-
If you selected to specify a DNS server, enter the IP address for at least one DNS server on your network.
You can enter up to three servers. -
Click Accept.
Reports
The firewall can complete a rolling analysis of the event log to show the top
25 most frequently accessed Web sites, the top 25 users of bandwidth by IP
address, and the top 25 services consuming the most bandwidth.
Generate these reports from the Device > Log > Reports page.
NOTE : SonicWall Analyzer provides a comprehensive Web-based reporting solution for firewalls. For more information on SonicWall Analyzer, go to http://www.SonicWall.com.
Data Collection
The Device > Log > Reports page includes these functions:
- Data Collection – Enable Start Data Collection to begin log analysis. When log analysis is enabled, the button label changes to Stop Data Collection.
- Click Reset icon to clear the report statistics and begin a new sample period. The sample period is also reset when data collection is stopped or started, and when the firewall is restarted.
- Click Refresh icon to update the real-time data in the table.
View Data
Select the desired report from Report View:
- Web Site Hits (default)
- Bandwidth Usage by IP Address
- Bandwidth Usage by Service
The length of time analyzed by the report is displayed in the Current Sample Period.
Web
Site Hits
Selecting Web Site Hits from the drop-down displays a table showing the URLs
for the 25 most frequently accessed Web sites and the number of hits to a site
during the current sample period.
The Web Site Hits report ensures that the majority of Web access is to
appropriate Web sites. If leisure, sports, or other inappropriate sites appear
in the Web Site Hits Report, you can choose to block the sites. For
information on blocking inappropriate Web sites refer to the Objects > Profile
Objects > Content Filter command in SonicOS 7.1 Objects Guide.
Bandwidth Usage by IP Address
Selecting Bandwidth Usage by IP Address from the drop-down displays a table
showing the IP address of the 25 top users of Internet bandwidth and the
number of megabytes transmitted during the current sample period.
Bandwidth Usage by Service
Selecting Bandwidth Usage by Service from the drop-down displays a table
showing the name of the 25 top Internet services, such as HTTP, FTP,
RealAudio, and so on, and the number of megabytes received from the service
during the current sample period.
The Bandwidth Usage by Service report shows whether the services being used
are appropriate for your organization. If services such as video or push
broadcasts are consuming a large portion of the available bandwidth, you can
choose to block these services.
Backup Logs Information
The logging information can be retained in an on-board database. It can also
preserve the data in the event of a loss of power. These features apply if the
appliance has had additional non-volatile storage built into the it and the
appliance is running SonicOS 6.5.1 or later.
The maximum number of entries that can be stored on the log database is
increased to 50,000 for all platforms, but the amount of space available is
driven by the size of the built-in storage module and space allocated for
logging.
If storage is available, backups of the logs are taken automatically and
requires no configuration. They can also be manually deleted.
NOTE : Loading the Log Reports page can be slower when there are too many
entries in the log database.
Similarly, exporting a log report can be slower.
To delete backups:
- Navigate to the Device > Settings > Storage > Files page.
- Under Logs group, click Purge.The backups are deleted.
AWS
The Device > Log > AWS Logs page allows configuration of the Amazon Web Services (AWS) endpoint to which the logs are sent along with settings affecting the frequency with which the data is posted.
Logged events generated on the firewall can be sent to the AWS CloudWatch Logs service. From there, the data can be used by AWS hosted analysis tools such as ElasticSearch and Kibana.
Enabling AWS Logs
NOTE : In order to send the logs from SonicOS to Amazon CloudWatch Logs,
you must first create a Log Group and a Log Stream in AWS.
If you already have an Identity Access Management (IAM) user account with the
appropriate permissions to access CloudWatch Logs from the AWS Console:
- Navigate to the CloudWatch section.
- Select the Logs item in the left navigation menu. Ensure that you have selected the appropriate AWS Region for the logs to be stored. As with many AWS services, CloudWatch Logs is region-specific.
- Create the Log Group.
- Create the Log Stream.
To enable AWS logs in SonicOS:
- Navigate to the Device > Log > AWS page.
- In the CloudWatch Logs section, select Enable Logging.
- Select the Region in which you created a Log Group and Log Stream in the AWS Console. (You can change the region used by the firewall either on this page or on the Network > System > AWS Configuration page.)
- Enter the names of the Log Group and Log Stream that you created in the AWS Console that holds the logs sent to AWS CloudWatch Logs.
- The logs are sent at the specified Synchronization Interval. Change the value of the interval (in seconds) to suit your needs.
- Optionally, you can click Force Sync to manually synchronize with your AWS Console settings.
- Click Accept.
SonicWall Support
Technical support is available to customers who have purchased SonicWall
products with a valid maintenance contract.
The Support Portal provides self-help tools you can use to solve problems
quickly and independently, 24 hours a day, 365 days a year. To access the
Support Portal, go to https://www.sonicwall.com/support.
The Support Portal enables you to:
- View knowledge base articles and technical documentation
- View and participate in the Community forum discussions at https://community.sonicwall.com/technology-and-support.
- View video tutorials
- Access https://mysonicwall.com
- Learn about SonicWall Professional Services at https://sonicwall.com/pes.
- Review SonicWall Support services and warranty information
- Register for training and certification
- Request technical support or customer service
To contact SonicWall Support, visit https://www.sonicwall.com/support /contact-support.
About This Document
SonicOS Device Log Administration Guide
Updated – December 2023
Software Version – 7.1
232-005865-00 Rev A
Copyright © 2023 SonicWall Inc. All rights reserved.
The information in this document is provided in connection with SonicWall
and/or its affiliates’ products. No license, express or implied, by estoppel
or otherwise, to any intellectual property right is granted by this document
or in connection with the sale of products.
EXCEPT AS SET FORTH IN THE TERMS AND CONDITIONS AS SPECIFIED IN THE LICENSE
AGREEMENT FOR THIS PRODUCT, SONICWALL AND/OR ITS AFFILIATES ASSUME NO
LIABILITY WHATSOEVER AND DISCLAIMS ANY EXPRESS, IMPLIED OR STATUTORY WARRANTY
RELATING TO ITS PRODUCTS INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY
OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT. IN
NO EVENT SHALL SONICWALL AND/OR ITS AFFILIATES BE LIABLE FOR ANY DIRECT,
INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL OR INCIDENTAL DAMAGES (INCLUDING,
WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, BUSINESS
INTERRUPTION OR LOSS OF INFORMATION) ARISING OUT OF THE USE OR INABILITY TO
USE THIS DOCUMENT, EVEN IF SONICWALL AND/OR ITS AFFILIATES HAVE BEEN ADVISED
OF THE POSSIBILITY OF SUCH DAMAGES. SonicWall and/or its affiliates make no
representations or warranties with respect to the accuracy or completeness of
the contents of this document and reserves the right to make changes to
specifications and product descriptions at any time without notice. and/or its
affiliates do not make any commitment to update the information contained in
this document.
For more information, visit https://www.sonicwall.com/legal.
End User Product Agreement
To view the SonicWall End User Product Agreement, go to:
https://www.sonicwall.com/legal/end-user-product-agreements/.
Open Source Code
SonicWall Inc. is able to provide a machine-readable copy of open source code
with restrictive licenses such as GPL, LGPL, AGPL when applicable per license
requirements. To obtain a complete machine-readable copy, send your written
requests, along with
certified check or money order in the amount of USD 25.00 payable to
“SonicWall Inc.”, to: General Public License Source Code Request
Attn: Jennifer Anderson
1033 McCarthy Blvd
Milpitas, CA 95035
SonicOS 7.1 Device Log Administration Guide
SonicWall Support
Documents / Resources
|
SONICWALL SonicOS 7.1 Device
Log
[pdf] User Guide
SonicOS 7.1 Device Log, SonicOS 7.1, Device Log, Log
---|---
References
- SonicWall.com
- sonicwall.com/
- SonicWall Community | Technology and Support
- MySonicWall
- sonicwall.com/pes
- MySonicWall
- sonicwall.com/legal
- sonicwall.com/legal/end-user-product-agreements/
- sonicwall.com/support
- sonicwall.com/support/contact-support
- sonicwall.com/support/technical-documentation/
- sonicwall.com/support/technical-documentation/?language=English&category=Firewalls&resources=Administration%20Guide&version=7.1
- sonicwall.com/support/technical-documentation/?language=English&category=Firewalls&resources=Getting%20Started%20Guide
- sonicwall.com/support/technical-documentation/?q=sonicos%20api&language=English
- sonicwall.com/support/technical-documentation/sonicos-7-1-api
- sonicwall.com/support/technical-documentation/sonicos-7-1-monitor
- sonicwall.com/support/technical-documentation/sonicos-7-1-system