Wood s WLD1 Dehumidifier Instruction Manual

June 15, 2024
Wood s

Wood s WLD1 Dehumidifier

Wood-s-WLD1-Dehumidifier-product

Specifications

  • Model : WLD1
  • Dimensions: 1000 mm x 664 mm
  • Refrigerant : R290/Propane
  • Humidity Range : 35-75%

Product Overview

The Wood’s Dehumidifier WLD1 is a high-quality appliance designed to remove excess moisture from the air. It is suitable for use in drying rooms and similar environments. The dehumidifier comes with a garden hose nozzle, control panel cover, wall mounting bracket, main switch, hose connection, service cover, and control panel.

Instructions for use

Product Overview

Safety Instructions

FLAMMABLE MATERIAL.
This appliance contains R290/ Propane, a flammable refrigerant.

  • Refer operator’s manual.
  • Read technical manual.
  • Read the operator’s manual.

SAFETY INFORMATION

Before installing and using the appliance, carefully read the supplied instructions. The manufacturer is not responsible if an incorrect installation and use cause injuries and damages. Always keep the instructions with the appliance for future reference.

CHILDREN AND VULNERABLE PEOPLE’S SAFETY

WARNING
Risk of injury or permanent disability.

  • This appliance can be used by children aged eight years and above, persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance safely and understand the hazards involved. Do not let children play with the appliance.
  • Children of less than three years should be kept away unless continuously supervised.
  • Keep all packaging away from children. Cleaning and user maintenance shall not be done by children without supervision.

GENERAL SAFETY

  • This appliance is intended to be used for drying laundry in drying rooms and similar environments. Keep ventilation openings clear of obstruction.
    Other than those recommended by the manufacturer, do not use mechanical devices or other means to accelerate the defrosting process. The appliance shall not be stored in a room where ignition sources are operating continuously (open flames, working gas appliance, operation electric heater, etc.). Do not pierce or burn. Be aware that refrigerants may not have an odor. Do not use water spray and steam to clean the appliance. Clean the appliance with a moist, soft cloth.

  • Only use neutral detergents. Do not use abrasive products, abrasive cleaning pads, solvents or metal objects. If the power cord is damaged, it must be replaced by the manufacturer, its authorized Service Centre or similarly qualified persons to avoid a hazard.

SAFETY INSTRUCTIONS

WARNING
Only a qualified person can install this appliance.

  • Remove all packaging material. Do not install or use a damaged appliance. The appliance shall be installed, operated and stored in a room with a floor area larger than 10m². Strictly follow the installation instruction supplied with the appliance. Always be careful when you move the appliance because it is heavy. Always wear safety gloves.
  • Make sure air can circulate around the appliance. Wait at least 4 hours before connecting the appliance to the power outlet. This is to allow the oil to flow back into the compressor. Do not install the appliance close to radiators or other heat sources. Do not install the appliance in direct sunlight.

ELECTRICAL CONNECTION

WARNING
Risk of fire and electrical shock.

  • For models with a power cord with a plug, the plug shall be connected to an earthed power outlet with the correct rating according to the product specification.
  • For models for fixed installation, electrical connection to power outlets and any additional equipment, e.g., timers, shall be performed by a qualified electrician. Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
  • Contact the authorized Service Centre or an electrician to change the electrical components. Connect the plug to the power source only at the end of the installation. Make sure that there is access to the plug after the installation. Do not pull the power cable to disconnect the appliance. Always unplug the power cable from the plug only.

USE

WARNING
Risk of injury, burns, electrical shock or fire.

Do not change the specification of this appliance. Be careful not to cause damage to the refrigerant circuit which contains propane (R290), a highly flammable gas. If damage occurs to the refrigerant circuit, make sure that there are no flames and sources of ignition in the room. Ventilate the room. Do not put flammable products or wet items with flammable products near or on the appliance.

DISPOSAL

WARNING
Risk of injury.

Disconnect the appliance from the mains supply. Cut off the mains cable and discard it. The refrigerant circuit of this appliance is ozone-friendly. Contact your local authority for information on how to discard the appliance correctly. Do not cause damage to the part of the cooling unit that is near the heat exchanger.

Operating Instructions

WOOD’S DEHUMIDIFIER WLD1
The Wood’s WLD1 is a powerful and sturdy dehumidifier intended to be used for drying laundry in drying rooms and similar environments.

Features

  • Automatic defrost for use in lower temperatures, down to 2°C.
  • Adjustable controls to direct the air out
  • Automatic restart with memory function after a power cut.
  • Easy to use controls.
  • Efficient air filters.
  • The refilter can easily be cleaned

PRODUCT OVERVIEW

See pages 2–3 for image product overview.

A DEHUMIDIFIER WLD1

  1. Garden hose nozzle
  2. Control panel cover
  3. Wall mounting bracket

B BACK SIDE WLD1

  1. Main switch
  2. Hose connection
  • C1 AIR FILTER – PREFILTER
  • C2 AIR FILTER – SMF-FILTER
  • D SERVICE COVER
  • E CONTROL PANEL COVER
  • F CONTROL PANEL
  • G WALL MOUNTING

Wood-s-WLD1-Dehumidifier-01 Wood-s-WLD1-Dehumidifier-02 Wood-s-WLD1-Dehumidifier-03 Wood-s-WLD1-Dehumidifier-04

CONTROL PANEL FUNCTION

DESCRIPTION
Note that the control panel powers down to idle mode 20 seconds after connection of mains voltage or after the last input. It is revived by touching the area where the function keys are located. All keystrokes are confirmed with a beep.
Some models have a ON/OFF button on the front which is used to start or stop the humidifier. On models without the button, the humidifier will start automatically when powered on and can be controlled by an external timer.
All models are equipped with a mains switch on the back of the product, refer image “B”

FUNCTION KEYS AND OPERATING MODES (REFER IMAGE “F”)

  1. Fan speed: The fan speed in Normal” and “Normal + Fan” modes may be set to 40%, 60%, 80% or 100% of maximum speed. Switching between the speeds takes place with a few seconds’ delay.
    In “Extra dry” mode, the fan speed can’t be changed.

  2. Setting of the desired humidity: Only active in program modes “Normal” and “Normal + Fan”.
    A desired humidity can be set between 35-75% in steps of 1 percentage point.
    The set value is first displayed fixed and then flashing before the actual value reappears.

  3. Mode selection: Selection of the operating program; refer to points 4- 6.

  4.  Normal mode: Used to set the target value for humidity and fan speed manually. When the set target value is reached, the compressor and fan shut off and restarts if the humidity rises above the target value.

  5. Normal + Fan mode: Continuous air circulation even if the humidity target value is reached.

  6. Extra Dry Mode: The dehumidification process is in continuous operation with the fan at maximum fan speed until it is turned off manually or the mode is changed.

  7. Relative humidity: Shows current and desired target values. The latter is in connection with target value setting.

  8. Defrost: If necessary, the cooling circuit is defrosted automatically, whereby the compressor is switched off, and only the fan is in operation.
    The symbol goes out when the dehumidification process is restarted.

  9. Low room temperature: If the ambient temperature falls below 2°C, the dehumidification process shuts off and resumes automatically when the ambient temperature rises above 2°C.
    The symbol is lit as long as the temperature is 2°C or lower.

  10. Too high ambient temperature: If the ambient temperature exceeds 35°C, the dehumidification process shuts off and resumes automatically when the ambient temperature falls below 35°C. The symbol is lit as long as the temperature is 35°C or higher.

  11. Room temperature: Displays the detected ambient temperature.

  12. Fan speed: Shows the fan speed in 4 steps. 1 bar is 40% speed, 2 bars 60%, 3 bars 80% and 4 bars are maximum speed.

INSTALLATION AND WALL MOUNTING (REFER IMAGE “G”)

  • I f the dehumidifier is transported, leave it standing for 4 hours before use. It is very important for the oil to flow back into the compressor, as the dehumidifier otherwise may take severe damage.
  • The dehumidifier must always be secured to the wall. Make sure the wall that the dehumidifier is being fixed to is strong enough to support its weight.
  • The dehumidifier should not be placed near radiators or other heat sources or exposed to direct sunlight, as it will reduce its performance.
  • For correct and optimal position of the unit, refer image “G”. For most efficient air flow, mount so that the exhaust is directed along the laundry.

To mount

  • G 1: Install the included wall bracket. Always make sure that you use the correct screws for the support of the machine to the wall
  • G2: Hang the dehumidifier
  • G3: Screw in the safety screws
  • Make sure that the airflow from the inlet and outlet isn’t blocked. Connect a ½” garden hose (hose not included) to the port on the unit. Route the hose into a drain.

CONTROL PANEL COVER (REFER IMAGE “E”
The dehumidifier is supplied with a display cover, so the settings cannot be changed. To mount the cover:

  1. Open the door.
  2. Loosen the screws of the display cover (2pcs).
  3. Remove the display cover.
  4. Reassembly is in reverse order.

THE HYGROSTAT

  • The dehumidifier will only run when the ambient humidity exceeds the set value, except when using “Extra dry” mode. When the set humidity is reached, the operation will automatically shut off and will resume in the same manner when the humidity rises.

MEMORY FUNCTION AND AUTOMATIC RESTART AFTER POWER FAILURE

  • In the event of a power failure, the unit will automatically restart when the power returns and continues to operate according to your latest settings.

AUTOMATIC DEFROST

  • The unit will defrost automatically when needed. When the unit is in defrost mode, the compressor shuts off, showing a symbol on the display. It will continue its operations once the defrost is completed.

DRAINAGE

  • Route the hose to a drain.

AIR FILTERS

  • The air filters prevent dust and dirt from entering the dehumidifier, prolonging its life expectancy. It will also clean the air as dust and other particles are collected by the filters.
  • The prefilter must be cleaned regularly; otherwise, the dehumidifier might lose capacity and be seriously damaged. To clean the prefilter, open the dehumidifier door. The filter is positioned at the front of the air inlet opening and is easily lifted out, refer image “C1”. Simply wipe any lint away with a damp cloth or you can use a vacuum cleaner. Ensure the filter is refitted properly to prevent unfiltered air from entering the unit.
  • The SMF filter, we recommend at least one SMF filter change per year, refer image “C2”. To follow the warranty program, Register your dehumidifier at warranty-woods.com

CLEANING AND MAINTENANCE

  • WARNING! Before performing any maintenance work on the drying room dehumidifier, the machine must be disconnected from the electrical supply. This is done by turning of
    the main (operation) switch. All maintenance on the electrical system must be performed by qualified electricians. All maintenance on the cooling system must be performed by qualified cooling technicians
    Use a soft, moist cloth to clean the external parts of the units. Avoid using solvents or strong cleaners, as this might damage the surface of the dehumidifier. It is important to check the air filters regularly and clean or replace them when needed.

RESETTING OF OVERPRESSURE PROTECTION

  • If the dehumidification process stops working, it may be due to  the overpressure protection being triggered. It is located behind the front cover and is reset as follows:
  1. Turn off power by removing the plug from the wall socket, or by turning off the main (operation) switch.
  2. Look for the cause of the protection being triggered and fix the fault. The cause may be an electrical fault or insufficient air circulation. Check the filter status and that the fan runs.
  3. Open the door. Remove the two screws on the cover, sitting next to the air outlet. Refer image “D”. There is a reset button for the overpressure protection inside the unit. Depress the button.
  4. Reattach the cover.

RECOMMENDED LIMITS FOR USE

  • Temperature: + 2˚C to + 35˚C
  •  Relative humidity: 35% to 90%
  • Recommended humidity level c.a. 50% RH

IMPORTANT
Wood’s dehumidifier shall be connected to a grounded electrical outlet with a voltage of 220V-240V 50Hz.

IF THE DEHUMIDIFIER REQUIRES

SERVICE

  • If the dehumidifier requires servicing, firstly contact the retailer. For all warranty claims, proof of purchase is required.

GUARANTEES

  • Two years guarantee against faults in manufacturing. Please note that the guarantee is only valid upon a purchase receipt’s presentation.

REGISTER THE PRODUCT FOR EXTENDED WARRANTY

  • Standard 2 years can be extended to 6 years if you register the product at warranty-woods.com and change the SMF filter at least once a year.

SAVE YOUR RECEIPTS!

  • Receipts will be required for any warranty claim during the period.
TECHNICAL DATA WLD1
Working Area >10 m2
Airflow 500-800 m3/h
Dehumidifying at 20° C and 70% r.h. 32 L/24h
Dehumidifying at 30° C and 80% r.h. 48 L/24h
Power at 20° C and 70% r.h. 500 W
Energy consumption at 20°C and 70% r.h. 14,5 kWh/24 h
Refrigerant R290
Charge 200 g
Voltage 220–240V
Frequency 50 Hz
Fuse 10A
IP Code IPX1
Dimensions in mm (L x W x H) 403 x 664 x 650
Weight 43 kg

Technical changes and improvements may occur. All values are approximate and may vary depending on external circumstances such as temperature, ventilation and humidity.

PROBLEM REMEDY
The dehumidifier does not start
  • Ensure that the dehumidifier is connected to the power socket and that the fuse has not blown.
  • Ensure that the main switch on the back of the product is ON
  • Check that the actual humidity value exceeds the set value.
  • Check that the temperature is above 2° C or below 35° C.

The dehumidifier does not dehumidify|

  •  Make sure the fan wheel is spinning.
  • Make sure that the air can flow freely through the dehumidifier. The air exhaust and air filters must be clean.
  • Listen if the compressor is running, but keep in mind that the dehumidifier may be defrosting, causing the compressor to stop.
  • Check that a thick layer of ice has not formed on the cooling circuit behind the filter.
  • Check the overpressure protection.
    • Check that the actual humidity value exceeds the set value.

Abnormal noise|

  • Check the levelling of the unit and the wall mounting installation

Error code E2|

  • If E2 is shown in the display, the humidity sensor may be defective. Try turn the mains switch to OFF, wait 10 seconds and turn it back ON. If the error code persists, contact your dealer.

If you have a problem with your dehumidifier, refer to the troubleshooting guide. If none of the above works, contact your dealer to get your dehumidifier serviced.

This marking indicates that this product should not be disposed with other household wastes throughout the UK and the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your us device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.

Register and find the latest updated user manual, usage advice, updated brochures, troubleshooting, and service information at woods.se

CUSTOMER CARE AND SERVICE

Always use original spare parts. When contacting our authorized service centre, ensure that you have the following data available: Model number, receipt, and serial number.
Warning / Caution-Safety information. General information and tips. Environmental information. Subject to change without notice.

Wood’s is marketed and distributed by:
Woods Production Sweden AB Maskingatan 2–4, 441 27 Alingsås, Sweden [email protected] +46 (0)31 761 36 10 woods.se

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Wood s User Manuals

Related Manuals