Wood s MRD20/25 Dehumidifier Instruction Manual

June 6, 2024
Wood s

OPERATING INSTRUCTIONS FOR:
**MRD20/25
Operating Instructions

**

Wood s MRD20 25 Dehumidifier

Visit woods.se for more information and updated instruction manuals.
For an extended warranty register your product at warranty-woods.com

Visit our website to:
Get usage advice, updated brochures, troubleshooter, and service information.
Register your product for additional services: www.warranty- woods.com

CUSTOMER CARE AND SERVICE
Always use original spare parts.
When contacting our Authorised Service Centre, ensure that you have the following data
available: Model number, receipt, and serial number.

Warning / Caution-Safety information.
General information and tips.
Environmental information.
Subject to change without notice.

Wood s MRD20 25 Dehumidifier - FIGURE 1Wood s MRD20 25 Dehumidifier - FIGURE
2

Wood s MRD20 25 Dehumidifier - FIGURE 3Wood s MRD20 25 Dehumidifier - FIGURE
4Wood s MRD20 25 Dehumidifier - FIGURE
5Wood s MRD20 25 Dehumidifier - FIGURE
6

WOOD’S ONE OF THE WORLD’S LEADING DEHUMIDIFIERS

Wood’s dehumidifiers have been known as market leaders for many years. Their dehumidifiers are suitable for use in the most demanding climates, where dehumidifying capacity is optimal even at different temperatures and humidity levels.

Excellent results can be achieved within indoor areas that become damp, such as basements, garages, pool rooms, attics, and summer houses. Compared to conventional tumble dryers, Wood’s dehumidifiers do not wear out clothes as they utilize a blow-drying effect while being energy efficient, making them ideal for drying laundry.

The amount of humidity that the dehumidifier removes depends on the temperature, humidity level, and placement. External weather conditions may also affect the performance of the dehumidifier. Wood’s dehumidifiers are safe in operation and intended for use over many years.

EXCESSIVE AIR HUMIDITY – A DANGER
Condensation occurs when water vapor in the air comes into contact with a cold surface such as a cold window or wall. When water vapor is cooled down, condensation occurs, and water drops are formed. In high air humidity, the air may get musty and mold might get formed, causing damage to a house and its furnishings. This environment may even cause illness for the residents. Mites and spiders also thrive in damp environments. A dehumidifier with high performance creates a good, healthy humidity level. For the greatest efficiency, the doors and windows of rooms that are being dehumidified should be kept closed. Removes odors, dries the wood, and removes moisture from outdoors equipment.

SECURITY WARNINGS

Flammable material. This appliance contains R290/Propane a flammable refrigerant.

Refer to this manual for safety information.

Read the technical manual.

Read operators manual.

SAFETY INFORMATION
Before the installation and use of the appliance, carefully read the supplied instructions. The manufacturer is not responsible if an incorrect installation and uses causes injuries and damages. Always keep the instructions with the appliance for future reference.

Children and vulnerable people safety

WARNING

Risk of injury or permanent disability.
This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Do not let children play with the appliance.

Children of less than 3 years should be kept away unless continuously

supervised.
Keep all packaging away from children.
Cleaning and user maintenance shall not be made by children without supervision.

General Safety
This appliance is intended to be used in households and similar applications such as – basements, crawl spaces; staff kitchen areas in shops, offices, and other working environments. The rating plate is located at the back or the side of the dehumidifier.
Keep ventilation openings clear of obstruction.

Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
The appliance shall not be stored in a room with operating ignition sources (for example; open flames, an operating gas appliance, or an operating electric heater. Do not pierce or burn.
Be aware that refrigerants may not contain an odor. Do not use water spray and steam to clean the appliance. Clean the appliance with a moist soft cloth. Only use neutral
detergents. Do not use abrasive products, abrasive cleaning pads, solvents, or metal objects.
If the supply cord is damaged, it must be replaced by the manufacturer, its Authorised Service Centre, or similarly qualified persons in order to avoid a hazard.

SAFETY INSTRUCTIONS

Installation

WARNING
Only a qualified person must install this appliance.
Remove all the packaging.
Do not install or use a damaged appliance. The appliance shall be installed, operated, and stored in a room with a floor area larger than 2 m². Obey the installation instruction supplied with the appliance.
Always be careful when you move the appliance because it is heavy.
Always wear safety gloves.
Make sure the air can circulate around the appliance.
Wait at least 4 hours before connecting the appliance to the power supply. This is to allow the oil to flow back into the compressor. Do not install the appliance close to radiators or other heat sources.
Do not install the appliance where there is direct sunlight.

Electrical connection
WARNING
Risk of fire and electrical shock.
The appliance must be connected to a grounded outlet.
Make sure that the electrical information on the rating plate matches with the power supply. If not, contact an electrician. Always use a correctly installed shockproof socket.
Do not use multi-plug adapters and extension cables.
Make sure not to cause damage to the electrical components (e.g. mains plug, mains cable).
Contact the Authorised Service Centre or an electrician to change the electrical components. The main cable must stay below the level of the main plug. Connect the mains plug to the mains socket only at the end of the installation.
Make sure that there is access to the mains plug after the installation.
Do not pull the main cable to disconnect the appliance. Always pull at the mains plug.

Use
WARNING
Risk of injury, burns, electrical shock or fire. Do not change the specification of this appliance.
Be careful not to cause damage to the refrigerant circuit. It contains propane (R290), a natural gas with a high level of environmental compatibility. This gas is flammable.
If damage occurs to the refrigerant circuit, make sure that there are no flames and sources of ignition in the room. Ventilate the room.
Do not put flammable products or items that are wet with flammable products near or on the appliance.

Disposal
WARNING
Risk of injury.
Disconnect the appliance from the main supply.
Cut off the main cable and discard it. The refrigerant circuit of this appliance is ozone-friendly.
Contact your municipal authority for information on how to discard the appliance correctly.
Do not cause damage to the part of the cooling unit that is near the heat exchanger.

SET UP DEHUMIDIFIER FOR INSTALLATION

Installation
BEFORE FIRST USE
Let the machine stand for 4 hours before using Selecting a Location.

Important

Wood s MRD20 25 Dehumidifier - FIGURE 7

  1. Dehumidifiers must be operated in an enclosed area to be most effective. Close all doors, windows, and other outside openings to the room. The effectiveness of the dehumidifier depends on the rate at which new moisture-laden air enters the room.
  2. Place a dehumidifier in a location that does not restrict airflow through the front of the unit.
  3. A dehumidifier operating in a room will have little or no effect in drying an adjacent enclosed storage area, such as a closet unless there is adequate circulation of air in and out of the area. lt may be necessary to install a second dehumidifier in the enclosed area for satisfactory drying.
  4. Ensure that the unit is placed on a stable and flat surface. If the surface is not stable there is a risk that the unit may be unstable and cause excessive vibration and that water will be released.
  5. The dehumidifier must have at least 20 cm free space around the entire dehumidifier.
  6. Fuse for PCB: F1: 2010 Serie(s), AC250V, T, 2.0A; F2: 2010 Serie(s), AC250V, T, 5.0A/6.3A

PRODUCT DESCRIPTION

A

  1. Handle
  2. Control panel
  3. Top lid
  4. Swing function
  5. Front case

B

  1. Filter
  2. Continuous drain pipe
  3. Power cord
  4. Back casing
  5. Water tank

C Control Panel

  1. Display function

D Picture D (Picture of symbols on the control panel)

  1. Power button: This button can control the machine on/off.
  2. Mode button: This button can set the machine to work under dry mode or dehumidification mode. (during the dry mode, it dehumidifiers continuously under the highest speed)
  3. Humidity button: During the dehumidification mode, this button can set different desired humidity and the range is 50-55-60-65-70-Co-40-45-50-55-60-6570%RH.
  4. Timer button: During operation, if you press this button for <0.5 seconds it can set the timer off function 0H/1H/2H/3H/4H/5H/6H/7H/8H to operate a countdown.
  5. Fan speed button: This button can set machine to work under low speed or high speed.
  6. Swing button: This button can set machine to swing or not swing automatically.
  7. Defrost active.
  8. Water bucket full.
  9. Child lock: If press the timer button for 3 seconds it can set the child lock function on or off. During the child lock function, only the timer and on/off button can be set. Just press this button for 3 seconds again to switch off the child lock function.

E
TOP AND BUTTON

  1. Sketch on the top and underneath the machine

F

  1. The dehumidifier must have at least 20 cm free space around the entire dehumidifier.

PLACEMENT OF DEHUMIDIFIER

  • The dehumidifier should not be placed near radiators or other heat sources or exposed to direct sunlight, as it will reduce performance.
  • Ideal is to put it in the center of the room/area.

NOTE: When placed in a shower room or bathing area, the dehumidifier should be fixed in place. It is compulsory to check and respect your local bathroom electrical regulations before use.

USING THE DEHUMIDIFIER
If the dehumidifier is transported horizontally, let the dehumidifier stand for 4 hours before being used. It is very important that the oil runs back into the compressor,  otherwise, the dehumidifier may be seriously damaged.

  1. Check that the water reservoir is correctly placed.
  2. Connect the dehumidifier to a grounded power source.
  3. Set the desired humidity level by means of the humidity control. See the section on the humidity control.

NOTE: The ambient relative humidity can be simply measured with the dehumidifier.

OPERATION MANUAL

  1. Power Button: This button can control
    the machine on and off.

  2. Humidity button: To set the desired humidity. press the Humidity button for 5s, it shows ambient temperature (0~40°C) for 5s; if you press and hold the Humidity button,  it shows the ambient temperature all the time. If you don´t press again it automatically shows the NTC sensor temperature for 5 seconds then, shows ambient humidity.

  3. Humidity Settings: Open the air outlet set humidity between 40%, 50%, 60%, or continuous mode.

  4. Timer: When the appliance is on, press the Timer 2H/4H/6H to operate a countdown.

  5. During operation, it shows ambient humidity from 30,31,32···79,80. If it is < 30%RH, it shows LO; if it is > 80%RH, it shows HI.

  6. In dehumidification mode, you can set humidity level and fan speed 2 levels.

MEMORY FUNCTION

  1. Press the on/off button (plugged into a power socket) and then press the on/off button again to go back to following previous the timer, but timer and child lock function have no memory.
  2. No power when operation equals to plug off all of a sudden the machine works automatically when there is power and it memories previous setting, but child lock function has no memory.
  3. The unit will automatically turn on and operate in the last setting after power returns. It works under the initial default setting during dehumidification mode and works under humidity setting by 50%RH on high speed.

COMPRESSOR PROTECTION FUNCTION

The unit is equipped with a compressor protection function—that is, the compressor has five minutes period between starts operation and shut down.

WATER DRAINAGE
When the water reservoir is full, the dehumidifier is shut off automatically. Once the water reservoir is emptied the unit will automatically restart.

  1. Disconnect the dehumidifier from the power source.
  2. Empty the water reservoir.
  3. Put the empty water reservoir back and check that the float moves freely.
  4. Connect the dehumidifier to the power source.

Direct water drainage
Connect a water hose to the pipe on the back of the dehumidifier. Lead the other end to a drain. Make sure that the water can be drained downwards.

AIR FILTER

The air filter prevents dust and dirt from entering the machine, prolonging its life expectancy. It is important the filter is cleaned regularly.
Filter cleaning:

  1. Remove the filter.
  2. Wash it with warm water and a mild cleansing agent. Alternatively, the filter may be vacuum cleaned.
  3. Let the filter dry and put it back.

DEFROSTING OPERATION

During the defrosting operation, the dehumidification function may intermit. Please don’t turn off the switch or pull out the power plug of the dehumidifier during the defrosting operation. This dehumidifier can’t be applicable to keep extremely low temperatures. The purpose of this dehumidifier is to pump off the unpleasant high humidity in daily life and dry the wet things. But it can’t be used to keep extremely low temperatures. The room temperature increases during the operation.

This dehumidifier doesn’t have a colling function. It will produce heat during the operation and increase the room temperature to 1 to 4°C. In addition, the door and windows  are closed and other appliances in the room can give out heat as well as the radiation of the sun can raise the room temperature.

MAINTENANCE AND CLEANING

For its casing is made of plastic, do not place it in direct sunlight. Remove the water tank with care. If not using the unit for a long time. Please Switch off and unplug the unit, empty the water reservoir, keep it in a dry and ventilated place. Only use a soft clean cloth for all cleaning purposes. Do not use gasoline, paint thinner or other chemicals to clean the unit. Cleaning mesh filter: Remove the filter using a vacuum cleaner or water to clean, then put it in ventilated place until it’s dry.

SERVICE
If the dehumidifier requires servicing, you must first contact your local retailer. Proof of purchase is required for all warranty claims.

STORAGE

Before storage of the unit, please follow these steps:

  1. Make sure the water tank is empty. When the unit is switched on, make sure the unit work at Ventilation mode for at least 30 minutes to remove the water inside the unit.
  2. Collect and bundle the power cord.
  3. Clean the filter.
  4. Store in a clean, dry environment. Proof of purchase is required for all warranty claims.

HINTS
When the dehumidifier is used in extremely damp environments or when the temperature is below +5˚C, the dehumidifier may stop working. A large amount of ice builds up on the cooling coil. Turn off the dehumidifier and place it a little above floor level so that the ice will melt away.

Sometimes it may be useful to use a frost guard or heater fan to make sure that the temperature does not fall below +10˚C. Even if the MRD20/25 works down to temperatures as low as +5°C, its capacity will increase at higher temperatures as warm air carries more water.
The hydrostat has a margin of error of approx. +/- 5-10%. At lower temperatures, the margin of error might increase further. For maximum dehumidifying power in a room, it  is recommended that the air supply from outside and from adjoining rooms is minimized – close doors and ventilators.
Expect higher dehumidification capacity during Autumn / Summer because the outside air is warmer and more humid.

IMPORTANT! – Wood’s dehumidifier must be connected to a grounded power source. The power source should be 220V-240V 50Hz

PROBLEM CAUSE REMEDY
The dehumidifier does not work The power is not connected Check that

dehumidifier is connected to electricity and that fuse has not gone.
Check that the water reservoir is empty and correctly placed in the dehumidifier.
Does not dehumidify| The water container is full.
The water container has not been replaced correctly.
The air filter is clogged. The temperature or relative humidity in
the room where the device is operating is too low.| Remove the water from the container.
Place the water container in the correct position.
Clean the air filter.
Check that air can flow freely through the dehumidifier. The front grid and air filter should be clean and the dehumidifier should stand 20cm from the wall.
The dehumidifier
works, but reduce
the relative humidity
insufficiently.| The room is too large.
There are too many sources of humidity.
There is too much ventilation| We recommend using a dehumidifier with a larger capacity.
We recommend using a dehumidifier with a larger capacity.
Reduce ventilation(e.g close windows and shut doors)

If you are having trouble with your dehumidifier, please refer to the troubleshooting. If none of these works, please contact your retailer for servicing of your dehumidifier.

Guarantees

2 years consumer warranty against production faults. Please note that the warranty is only valid upon the production of the receipt. The warranty is only valid if the product is used in accordance with the instructions and security warnings expressed in this manual. The warranty does not cover any damages caused by improper handling of the product.

NOTE: The 2 years warranty only applies to consumers and not for commercial use of the unit.

NOTE!
Register at www.warranty-woods.com and read about how to get an extended warranty. Please visit www.woods.se for more information.

Recommended limits for use
Temp. +5˚C to +35˚C
Relative humidity: 30% to 90%
Recommended humidity level: appr. 50% RH

| MRD20
---|---
Max. working area| 70m2
Airflow| 175m3/h±10%
Dehumidifying at 30˚C and 80% r.h.| 20 l/24h
Power at 30˚C and 80% r.h.| 280 W±10%
Tank volume| 3,8 liters
Refrigerant| R290
Charge R290| 60 g
Voltage| 220-240V
The noise level in decibels| 48dB
Weight| 15,5 kg
Dimensions in mm, L x Bx H| 355x252x567
| MRD25
---|---
Max. working area| 120m2
Air flow| 180m3/h±10%
Dehumidifying at 30˚C and 80% r.h.| 25 l/24h
Power at 30˚C and 80% r.h.| 380 W±10%
Tank volume| 3,8 liters
Refrigerant| R290
Charge R290| 85 g
Voltage| 220-240V
Noise level in decibels| 48dB
Weight| 16kg
Dimensions in mm, L x Bx H| 355x252x567

*Technical changes and improvements may occur. All values are approximate and may vary due to external circumstances such as temperature, ventilation, and humidity.

*This marking indicates that this product should not be disposed of with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your us device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmentally safe recycling.

Wood’s is marketed and distributed by:
Woods Production Sweden AB
Maskingatan 2-4
441 27, Alingsås
Sweden.
woods.se
info@woods.se
+46 317613610

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals