Safety Instructions

FLAMMABLE MATERIAL. This appliance contains R290/ Propane, a flammable refrigerant.

Refer operator’s manual.
Read technical manual.
Read the operator’s manual.

SAFETY INFORMATION

Before installing and using the appliance, carefully read the supplied instructions. The manufacturer is not responsible if an incorrect installation and use cause injuries and damages. Always keep the instructions with the appliance for future reference.

CHILDREN AND VULNERABLE PEOPLE’S SAFETY

WARNING
Risk of injury or permanent disability.

This appliance can be used by children aged eight years and above, persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge if  they have been given supervision or instruction concerning the use of the appliance safely and understand the hazards involved. Do not let children play with the appliance.

Children of less than three years should be kept away unless continuously supervised.

Keep all packaging away from children. Cleaning and user maintenance shall not be done by children without supervision.

GENERAL SAFETY

This appliance is intended to be used in households and similar environments such as basements, crawl spaces, staff kitchen areas in shops, offices and other working environments. Keep ventilation openings clear of obstruction.

Other than those recommended by the manufacturer, do not use mechanical devices or other means to accelerate the defrosting process.
The appliance shall not be stored in a room where ignition sources are operating continuously (open flames, working gas appliance, operation electric heater, etc.).
Do not pierce or burn. Be aware that refrigerants may not have an odor.
Do not use water spray and steam to clean the appliance. Clean the appliance with a moist, soft cloth. Only use neutral detergents.
Do not use abrasive products, abrasive cleaning pads, solvents or metal objects. If the power cord is damaged, it must be replaced by the manufacturer, its authorized Service Centre or similarly qualified persons to avoid a hazard.

SAFETY INSTRUCTIONS

WARNING
Only a qualified person can install this appliance.

Remove all packaging material. Do not install or use a damaged appliance.
The appliance shall be installed, operated and stored in a room with a floor area larger than 3m². Strictly  follow the installation instruction supplied with the appliance. Always be careful when you move the appliance because it is heavy. Always wear safety gloves.

Make sure air can circulate around the appliance. Wait at least 4 hours before connecting the appliance to the power outlet. This is to allow the oil to flow back into the compressor. Do not install the appliance close to radiators or other heat sources. Do not install the appliance in direct sunlight.

ELECTRICAL CONNECTION

WARNING
Risk of fire and electrical shock.

The appliance must be connected to a grounded outlet. Ensure that the electrical information on the rating label is in accordance with the power supply. If not, contact an electrician. Always use a correctly installed shockproof socket. Do not use multi-plug adapters and extension cables. Make sure not to cause damage to the electrical components (e.g. plug, cable). Contact the authorized Service Centre or an electrician to change the electrical components. The cable must stay below the level of the plug. Connect the plug to the power socket only at the end of the installation. Make sure that there is access to the plug after the installation. Do not pull the power cable to disconnect the appliance. Always unplug the power cable from the plug only.

Thank you for your purchase and trust in Wood’s. Please read the instructions below on operating and caring for your Wood’s product.

PRODUCT PARTS (REFER IMAGE A, PAGE 2–3)

  1. Top cover
  2. Vent
  3. Front shell
  4. Chassis
  5. Wheels
  6. Control panel
  7. Back shell
  8. Filter
  9. Water tank
  10. Drain port

CONTROL PANEL

Power button (6): After the power is turned on, the indicator light is green and is on for a long time.

Mode button (5): Press the “Mode” button. There are three working modes: dehumidify mode (DEH), fan mode (FAN), and (DRY) dry mode.

Down button (4): Click to adjust the set humidity level or timing time. Press and hold the button for 3 seconds to select the mould removal function, and the “DRY INSIDE” light will be on. This function can only be turned on when the machine is turned on. If this function is turned on and the machine is turned off later, the fan motor will be turned off after a delay of 5 minutes. (During the delay shutdown process, except for the power indicator, other indicators are turned off). This feature is turned off by default.

Up button (3): Click the button to adjust the set humidity or timing time upwards.

Fan speed button (2): Press the fan speed button to select the fan speed. “HIGH” for high speed and “LOW” for low speed. Press and hold the fan speed button for three seconds to turn off or turn on the triangular display on the front face. When the hidden digital display is turned off, the display board digital tube and indicator light have a dark display function. If there is no operation for 5s, it will enter the dark display state.

Timer button (1): Press the timing key to set timing/query timing/cancel timing.

Child lock function (1) + (2): Press this group of keys to enable or disable the child lock “LOCK” function.

MODEL WITHOUT PUMP

Ambient temperature (3) + (4): Press this group of keys and the ambient temperature can be showed.

MODEL WITH PUMP

Ambient temperature (1) + (3): Press this group of keys and the ambient temperature can be monitored.

Check filter indicator (1) + (4): Press this group of keys and the “CHECK FILTER” indicator light  can be turned off, and the timing of the filter cleaning prompts to restart the timing.

Water pump function (3) + (4): By pressing these keys simultaneously, the automatic drainage “AUTO DRAIN” function of the pump can be turned on or off.

OPERATION INSTRUCTIONS

  • Plug in the power plug. Please pay attention to ensure that the machine’s power supply is consistent with the power grid.
  • Please press both sides of the swing to manually adjust the swing leaf to the desired angle.

WORKING MODE

Dehumidify Mode (DEH):
A. The Compressor will start when the humidity level is higher than 3% of set level, during which time, the fan will run at the set wind speed. When the humidity level falls to 3% from the set level, the compressor will automatically turn off and the fan will blow on low speed. (The fan speed can be adjusted at this time).

B. Display the set humidity (CO-35-85%RH): Press the up and down adjustment keys to adjust the desired humidity.

C. The fan speed is adjustable. “HIGH” for high speed and “LOW” for low speed.

D. Child lock and timer functions can be set.

E. MODEL WITHOUT PUMP ONLY: When the ambient humidity does not reach the set humidity, the red indicator light of the “OK” light on the display panel is off. When the ambient humidity reaches the set humidity, the “OK” light on the display panel will light up in red.

F. The triangular hidden display on the front shell displays three colors according to the humidity. It shows red when the relative humidity is higher than 65%, green when the relative humidity is between 45% and 65%, and blue when the relative humidity is below 45%.

G. When the set humidity is “CO”, the compressor runs continuously without limiting the set humidity, and the fan speed is adjustable. Also, when the CO is displayed, the child lock and timer can be set.

Fan Mode (FAN):
When entering the air supply mode through the mode conversion, the compressor will not work; the default is low wind, the fan speed is adjustable, and the ambient humidity (30~90%RH) is displayed.

1.3 Dry Mode (DRY):
Entering the “dry mode” will run a fixed, continuous high airflow no matter the humidity level.

TIMER FUNCTION “TIMER”

A. Press the timing key to start the timing function, and you can set the timing/query timing/ cancel the timing.

B. In the non-timed state: press the “timing” key (1, refer image F, page 2-3) to enter the timing setting state, the timing indicator light is on, and the digital tube flashes (5 times, 1 time/second) to display the timing time during the blinking period, press the “up or down” key to set Timing time between (0~24), the selected time will be confirmed after it flashes five times (or if there are other valid key operations during the flashing period, it will be confirmed immediately).

C. In the timing state: press the “timing” key (1, refer image F, page 2-3) to enter the timing query state, the digital tube flashes (5 times, 1 time/ second) to display the timing time, and press the “timing” key (1, refer image F, page 2-3) again during the digital flashing period to cancel the timing.

D. During the timing period, the “TIMER” indicator light is on. After the timing is over, the timing indicator will turn off.

E. The current on/off state will not be changed when setting the timing on/off; the setting of the timing function is only valid for the last time and only once. The on/off operation caused by a key press will clear all timing settings.

CHILD LOCK FUNCTION “LOCK”

Press the “1” + “2” keys (refer image F, page 2-3) at the same time to turn on the child lock function, the child lock indicator light “LOCK” ison, and all key operations are invalid; press this group of composite keys again to turn off the child lock function, and the child lock indicator light is off.

WATER FULL ALARM FUNCTION “FULL”

When the “water full” signal is detected for 5 seconds (the water level switch is disconnected), the machine will be turned off, the buzzer will sound five alarms, the water full indicator light “FULL” will be on, and the digital tube will flash to display “FL” until the water is removed.

FILTER CLEANING REMINDER FUNCTION “CHECK FILTER” (MODEL WITH PUMP ONLY),

After the machine has been running for 250 hours in total, the filter cleaning indicator “CHECK FILTER” lights up, reminding to clean the water pump inlet filter (refer image C, page 2-3) and the unit air inlet filter (refer image E, page 2-3). After cleaning, press the (1) + (4) keys (refer image F, page 2-3) to reset the filter reminder, the indicator light will turn off, and the timing cleaning reminder will restart.

AUTOMATIC DRAIN FUNCTION “AUTO DRAIN” (MODEL WITH PUMP ONLY)

Press (3) + (4) keys (refer image F, page 2-3) simultaneously to turn on the automatic drainage function of the water pump, and the drainage indicator light “AUTO DRAIN” will be on. When it is detected that the water is full, the water pump enters the automatic drainage program.

NOTE! The water is drained when the container is full. When the unit detects that the container is full, the pump is activated and the water is drained in approximately 45 minutes

DRAINAGE INSTRUCTIONS (MODEL WITHOUT PUMP)

USE OF WATER TANK (REFER IMAGE C, PAGE 2-3):

  1. When the water tank is full, the machine automatically stops running, the water full indicator “FULL” light is on, and the LED digital screen flashes “FL” and sounds an alarm five times.
  2. Put your hand on the depression at the bottom of the water tank, gently take out the water tank, tilt the water tank and pour out the water in the water tank from the drain port.
  3. Push the water tank back to the correct position, then turn on the dehumidifier.

Note: Please empty the water in the water tank. Before putting the water tank into the body, please confirm that the water tank’s cover and tank are installed tightly and that the handle is put back in its original position. Then, gently push the water tank into the correct position with both hands.

CONTINUOUS DRAINAGE METHOD  (REFER IMAGE B, PAGE 2-3):

If you don’t want to pour the water in the water tank frequently, you can connect a drain hose (the inner diameter of the hose is 10mm) behind the machine to drain the water.

  1. Find the location of the drain at the back.
  2. Use a suitable drain hose length to firmly connect it to the drain port.
  3. Before use, please carefully check and ensure that the water hoses are connected firmly to prevent water from leaking.

DRAINAGE INSTRUCTIONS (MODEL WITH PUMP ONLY)

USE OF WATER TANK (REFER IMAGE C, PAGE 2-3):

  1. Before removing the water tank, please press the power button to turn it off.
  2. Put your hand on the depression at the bottom of the water tank, gently take out the water tank tilt the water tank and pour out the water in the water tank from the drain port.
  3. Put the water intake pipe into the water tank as shown in the picture, then push the water tank back to the correct position and turn on the dehumidifier again.

Note: After emptying the water tank and before putting the water tank into the machine, please confirm that the water tank’s cover and tank are installed tightly and that the handle is returned to its original position. Then gently push the water tank into the correct position with both hands.

  • Please pay attention to whether the water intake hose is put into the water tank correctly, and pay attention not to press the water intake hose by the water tank.

CONTINUOUS DRAINAGE METHOD (REFER IMAGE B, PAGE 2-3):

If you don’t want to pour the water from the water tank frequently, you can connect a drain pipe/ hose (the inner diameter of the hose is 10mm) behind the machine to drain the water.

Step 1: The first step is to find the location of the drain at the back.

Step 2: Use a suitable drain hose length to firmly connect it to the drain port.

Step 3: Before use, please carefully check and ensure that the water hose is connected firmly to
prevent water from leaking.

WATER PUMP FOR AUTO DRAIN “AUTO

DRAIN” (REFER IMAGE D, PAGE 2-3):

  1. The model with a water pump can also choose the automatic drain “AUTO DRAIN” function.
  2. Use a suitable tool to open the hole plugging piece at the position (refer image D, page 2-3).
  3. Insert the water hose into the drain port as shown in the figure and connect firmly.
  4. Put the other end of the water hose into the floor drain or a large water storage container. If you use a large water storage container, pay attention to the water level of the container to prevent the water in the container from overflowing.
  5. Pressing (3) + (4) at the same time (refer image F, page 2-3), the auto drain indicator “AUTO DRAIN” of the pump can be turned on or off.

WARNING: Do not remove the water tank when the auto drain is switched on. If you need to remove the water tank, please press the power button to turn it off. Do not operate in violation of regulations; otherwise, it will cause damage to the components of the unit.

MAINTENANCE

Before maintaining the machine, please turn off the power and pull out the power plug.

  1. Clean the surface
    Clean the surface of the unit with a soft, damp cloth. Do not use alcohol, gasoline and other chemical solvents; otherwise, the machine or machine’s surface will be damaged.

  2. Cleaning the filter (refer image E, page 2-3)
    Please clean the nylon filter at least once every two weeks, washing with cold or warm water not exceeding 40 degrees. If the filter is not very dirty, simply vacuum the dust off it. Never use a dryer of any kind. Do not use alcohol, gasoline, benzene and other chemical solvents to clean.

  3. Storage of the machine
    After cleaning, please fix the power cord, pack the dehumidifier body in a soft plastic bag, and put the dehumidifier body in a dry place to take dustproof measures and keep it out of the reach of children.

3 YEARS WARRANTY

In order to extend the warranty from 2 to 3 years, please register your product after your purchase at warranty-woods.com

SAVE YOUR RECEIPTS!

These will be required for any warranty claim during the period.

TECHNICAL SPECIFICATIONS

WOOD’S MODEL NO. MDX20 + MDX20P (PUMP) MDX25 + MDX25P (PUMP)
Capacity 20L 25L
Recommended surface (room size) 20-25 m² 25-35 m²
Maximum area 40 m2 55 m²
Working interval temperature 5-35°C 5-35°C
Dehumidifier  Capacity 26.7°C/60%RH (L/D) 11 l
30°C/80%RH (L/D) 20 l 25 l
Rated Input 360W 410W
Power at 20°C and 70%RH 250W 310W
Power consumption at 20°C and 70%RH 3kWh/24 h 4kWh/24 h
Tank volume 6L 6L
Number of ventilation speeds 2 2
Air flow High Speed 180 m3/h
Low Speed 120 m3/h 120 m3/h
Sound power High Speed 55 dB
Low Speed 53 53
Type of refrigerant gas R290/60g R290/70g
IP-Code IPX1 IPX1
Washable air filter YES YES
Water Pump Only MDX20P Only MDX25P
Device dimensions (WxHxD) 530335260mm 530335260mm
Net weight 13.65kg (MDX20)14kg (MDX20P) 14kg (MDX25)14,5kg (MDX25P)

Technical changes and improvements may occur. All values are approximate and may vary depending on external circumstances such as īemperaīure, ventilation and humidify.

TROUBLE SHOOTING

PROBLEM POSSIBLE REASON SOLUTIONS
Hot air The dehumidifier’s air passes through the temperature recovery unit,
so the hot air is discharged (no cooling function). This is not a

malfunction.
The dehumidifier is not working| Is the power plug unplugged?| Insert the power plug into the socket.
Is the tank full? Or is the tank placed in the wrong place?| Drain the standing water in the tank and put the tank back in the correct position.
Dehumidification function does not work| Is the temperature or humidity in the room too low?| During the dry season, the dehumidifying capacity of the dehumidifier will be reduced.
Are the air outlets or air inlets blocked?| Clean up any items that block the air outlet or air inlet.
No air flow| Is the air filter blocked?| Clean the air filter as above.
Too much noise when the machine is running| Is it improperly placed so that the machine is tilted or unstable?| Please prevent the machine from being used on unstable ground.
Is the air filter blocked?| Clean the air filter as above.
Model with pump. After the auto drain function is turned on, the “water full” alert appears| The water inlet filter of the water pump is clogged, and the drainage is slow.| After cleaning the water filter, turn on the power again.
The water tank is not installed in place, causing the alert.| Install the water tank in place and turn on the power again.
The water pump fails and does not drain.| Turn off the power, and then turn on the power again after overhauling the water pump.
Model with pump. Abnormal working sound of water pump| The water inlet hose of the water pump is not placed correctly, and water cannot be obtained.| Take out the water tank, put the water inlet management (drain hose) into the bottom of the water tank, and then put the water tank in place.
After the automatic drain function is turned on, remove the water tank.| Take out the water tank, put the water inlet management (drain hose) into the bottom of the water tank, and then put the water tank back in place.
Error Codes| Display “E1”;| Humidity sensor failure.
Display “E2”;| Tube temperature sensor failure: display “E2”;
Display “FL”| Water Full.
DEF. indicator lights up| This is not a malfunction. The machine turns on the defrosting function, and it will return to normal after a while.
If you have a problem wish your dehumidifier, refer ion he īroubleshooīing guide. If none of he above works, conical your dealer ion gee your dehumidifier serviced.

This marking indicates that this product should not be disposed with other household wastes throughout the UK and the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your us device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals