HANYOUNG NUX LM3DV LCD Multi Panelmeter Instruction Manual
- June 15, 2024
- HANYOUNG NUX
Table of Contents
LCD Multi Panelmeter
LM series
INSTRUCTION MANUAL
Thank you for purchasing Hanyoung Nux products. Please read the instruction manual carefully before using this product, and use the product correctly. Also, please keep this instruction manual where you can view it any time.
Safety information
Please read the safety information carefully before the use, and use the
product correctly.
The alerts declared in the manual are classified into Danger, Warning and
Caution according to their importance
DANGER| Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury
---|---
WARNING| Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury
CAUTION| Indicates a potentially hazardous situation which, if not
avoided, may result in minor injury or properties damage
DANGER
- The input/output terminals are subject to electric shock risk. Never let the input/ output terminals come in contact with your body or conductive substances.
WARNING
- This product does not contain an electric switch or fuse, so the user needs to install a separate electric switch or fuse externally.(Fuse rating: 250 V 0.5 A)
- To prevent defection or malfunction of this product, supply proper power voltage in accordance with the rating.
- To prevent electric shock or malfunction of product, do not supply the power until the wiring is completed.
- Since this product is not designed with explosion-protective structure, do not use it any place with flammable or explosive gas.
- Do not decompose, modify, revise or repair this product. This may be a cause of malfunction, electric shock or fire.
- Reassemble this product while the power is OFF. Otherwise, it may be a cause of malfunction or electric shock
- If you use the product with methods other than specified by the manufacturer, there may be bodily injuries or property damages.
- Due to the danger of electric shock, use this product installed onto a panel while an electric current is applied.
CAUTION
- The contents of this manual may be changed without prior notification.
- Before using the product you purchased, make sure that it is exactly what you ordered.
- Make sure that there is no damage or abnormality of the product during delivery.
- Do not use this product at any place with corrosive(especially noxious gas or ammonia) or flammable gas.
- Do not use this product at any place with direct vibration or impact.
- Do not use this product at any place with liquid, oil, medical substances, dust, salt or iron contents. (Use at Pollution level 1 or 2)
- Do not polish this product with substances such as alcohol or benzene.
- Do not use this product at any place with a large inductive difficulty or occurring static electricity or magnetic noise.
- Do not use this product at any place with possible thermal accumulation due to direct sunlight or heat radiation.
- Install this product at place under 2,000m in altitude.
- When the product gets wet, the inspection is essential because there is a danger of electric leakage or fire.
- If there is excessive noise from the power supply, using insulating transformer or noise filter is recommended. The noise filter must be attached to a panel which is already connected to a ground and the wire between the filter output and power supply terminal must be as short as possible.
- If puttig power cables closely together then It is effective against noise.
- Do not connect anything to the unused terminals.
- After checking the polarity of terminal, connect wires at the correct position.
- When this product is connected to a panel, use a circuit breaker or switch approved with IEC947-1 or IEC947-3.
- Install the circuit breaker or switch at near place for convenient use.
- Write down on a label that if the circuit breaker or switch is operating then the power will be disconnected since the circuit breaker or switch is installed.
- For the continuous and safe use of this product, the periodical maintenance is recommended.
- Some parts of this product have limited life span, and others are changed by their usage.
- The warranty period for this product including parts is one year if this product is properly used.
Suffix Code
Model | Code | Description |
---|---|---|
LM Model | ||
Appearance | 3 | |
6 | ||
Displayable Digit | 4 | |
Input Specification | DV | |
DA | ||
AV | ||
AA | ||
Output specifications | N | |
R |
output fixed.)
3R| | | 3-stage contact output
3N| | | 3-stage NPN open collector output
3P| | | 3-stage PNP open collector output
Optional output| –| | No option output
C| | RS-485 output (MODBUS-RTU)
T| | Transmission output (4-20 mA ****)
Power supply voltage| A| 100 – 240 V 50/60 Hz
Specifications
Model | LM3/6-DV | I LM3/6-DA | I LM3/6-AV | I LM3/6-AA |
---|---|---|---|---|
Size | •LM3 : 96(W) X 48(H) X 68(D) mm |
•LM6 : 72(W) X 36(H) X 81(D) mm
Power| 100 – 240 V ∼ 50/60 Hz
Power Consumption| •LM3-N: 6 VA or less
•LM3-3NC/3PC: 9 VA or less
•LM6-3/0P: 5 VA or less| •LM3-3R/3RC: 10 VA or less
•LM3-3NT/3PT: 10 VA or less
•LM6-RC 6 VA or less| •LM3-3RT: 11 VA or less
•LM6-N: 5 VA or less
•LM6-3R: 7 VA or less| •LM6-RT: 7 VA or less
Input signal| DC voltage| DC current| AC voltage / frequency| AC current /
frequency
Input range| 500V / 100V
50 V / 10 V
5V / 1V
200 mV / 50 mV| 5A / 2A
500 mA / 200 mA
50 mA / 4 – 20 mA
5 mA / 2 mA| 500V / 250V
110 V I 50 V
20V / 10V
2 V I 1 V| 5A / 2A
500 mA / 200 mA
50 mA / 20 mA
AC measurement method| AVG / RMS selective measurement
Input sampling cycle| 50 ms
Input sampling method| OVER sampling method using continuous approximation A /
D converter
Maximum allowable input| F.S. of each input range 110 %
Frequency measurement range| 0.2 – 9999 Hz (Frequency measurement range
depends on the decimal point position)
Display| •Negative-LCD • 4 digit 2 rows • PV (White) • SV (Green)
Character size| •LM3: 17.6 X 10.6 mm •LM6 : 7.0 X 11.5 mm
Maximum display| – 9999 ∼ 9999
Display degree| •[ 23 °C ± 5 °C ] – F.S. ± 0.1 % rdg ± 2 digit
•[ 23 °C ± 5 °C, 5 A ] – F.S. ± 0.3 % rdg ± 3 digit
•[ 50 °C – – 10 °C ] – F.S. ± 0.5 % rdg ±3 digit| •[23 °C ± 5 °C] J – F.S. ±
0.3 % rdg ±3 digit
•[23 °C ± 5 °C, frequency ] – F.S. ± 0.1% rdg ± 2 digit
•[ 50 °C – – 10 °C ] – F.S. ± 0.5 0/0 rdg ± 3 digit
Control output| •Contact output : 3 stage, SPST (la), 250 V ∼ 5 A
•Solid state output: 3-stage, NPN or PNP open collector, 12 – 24 V 50mA or
less
Relay life time| •Electrical (about 100,000 times, 250 VA/ 5 A) • Mechanical
(about 5 million times)
Optional output| •Transmission output (4-20 mA) • RS-485 output
External input| •HOLD/ZERO Optional input • Non-voltage input • Short circuit
impedance: 300 0 or less
•Residual voltage: 1 V or less • Impedance when open: 100 k.0 or more
Communication| •Communication protocol : Modbus-RTU • Communication method :
RS-485 (2-wire half duplex)
•Communication speed : 2400 / 4800 / 9600 / 19200 / 38400 bps
Insulation Resistance| 100 MO or more (500 V Mega standard, between
conductive terminal and case)
Withstand voltage| 2000 V ∼ 60 Hz 1 minute (between conductive terminal and
case)
Noise| ± 2 kV(Between operation power terminals, Pulse width =1 us, Square
wave noise by noise simulator)
Vibration resistance| 10 – 55 Hz, Single amplitude 0.5 mm, 3-axis angular, 2
hours
Approval|
Protection structure| •IP66 (front) • Terminal block protection cover applied
Ambient temperature and humidity| – 10 – 50 °C, 35 ∼ 85 % RH
Storage temperature| – 20 ∼ 65 °C
Dimension & Panel cutout
- Dimension
- Panel cutout
Classification| Product dimensions (Protective cover)| Panel
cutout
---|---|---
Type| W| H| D| D1| D2| L| W2| H2| W1| H1| A| B
LM3| 96.0| 48.0| 55| 3.5| 16.1| 74.6| 91.0| 44.8| 91.5| 45.5| 121.5| 70.1
LM6| 72.0| 36.0| 68| 3.5| 16.1| 87.6| 66.0| 30.5| 66.5| 32.0| 96.5| 57.0
Part names and functions
NO | Function | |
---|---|---|
1 | PV Display | Operation mode: Measured value / maximum value / minimum value |
Display
Function mode: Parameter display
2| SV Display| Operation mode: Set in function mode Input range display
Function mode: Parameter setting value display
Setting mode: Upper / lower limit comparison value display (Only for output
model)
3| LOW output lamp| Lights up when the lower limit output is operating
4| GO output lamp| Lights up during GO output operation
5| HIGH output lamp| Lights up during high limit output operation
6| MAX lamp| Lights up when the PV display is in the maximum value display
mode
7| MIN lamp| Lights up when the PV display is in the minimum value display
mode
8| HZ lamp| Lights up when the PV display is in the frequency measurement mode
(Displayed on AV / AA models only)
9| A / mA lamp| Lights up when PV display is in current measurement mode
10| V / mV lamp| Lights up when PV display is in voltage measurement mode
11| AC lamp| Lights up when the model is AV / AA model
12| DC lamp| Lights up when the model model is DV / DA model
13| H lamp| Lights up when SV display is in the upper limit comparison value
display mode
14| L lamp| Lights up when SV display is in the lower limit comparison value
display mode
15| RMS lamp| Lights up in RMS measurement mode (AV / AA models only)
16| COM lamp| Lights up when model model is communication model
17| CWP lamp| Lights up when communication write prohibition is set
18| LOCK lamp| Lights up when locked
19| HOLD lamp| Lights up when external HOLD signal is applied
20| ZERO lamp| Lights up when external ZERO signal is applied
Front-key functions and names
Name | Function |
---|---|
MODE | • In operation mode, press key for more than 3 seconds to enter |
function mode
• In operation mode, when SV display window is in input range display mode,
press key, H lamp is turned on and the SV display window is converted to
the upper limit comparison value.
• In operation mode, when SV display window is in upper limit comparison value
display mode, press key, L lamp lights up and the SV display window is
converted to the lower limit comparison value.
• In operation mode, when SV display window is in lower limit comparison value
display mode, press key, L lamp goes out and the SV display window is
converted to the input range value set in the parameter.
• If the model is not an output model or O-MD is OFF, the SV display window is
fixed with the input range value set in the parameter.
SHIFT | • In the operation mode, when the SV display window is in the upper
limit comparison value display mode, press the key to enter the upper limit
comparison value setting mode.
• In operation mode, when SV display window is in the lower limit comparison
value display mode, press the key to enter the lower limit comparison value
setting mode.
• Pressing the key in the upper limit comparison value setting mode moves the
digit of the upper limit comparison value.
• Pressing the key in the lower limit comparison value setting mode moves the
digit of the lower limit comparison value.
• The setting range of the upper limit comparison value and lower limit
comparison value depends on the decimal point position set in the parameter.
can be set as ‘9.999 ~-9.999 / 99.99 ~- 99.99 / 999.9 ~-999.9 / 9999 ~-9999”
ZERO / DOWN | • Pressing the key in the upper limit comparison value setting
mode decreases the upper limit comparison value in the SV display window.
• Pressing the key in the lower limit comparison value setting mode decreases
the lower limit comparison value in the SV display window.
• In operation mode, key is pressed for more than 1 second, the current
measured value is forcibly corrected and stored automatically in the parameter
ZERO.(However, when parameter K-ZO is selected as ‘ON’)
• Pressing the key in the maximum value display mode resets the maximum and
minimum values.
• Pressing the key in the minimum value display mode resets the maximum and
minimum values.
PEAK / UP | • When the key is pressed in the operation mode, the PV display
window changes to the maximum value display mode.
• When the key is pressed in the maximum value display mode, the PV display
window changes to the minimum value display mode.
• key is pressed in the minimum value display mode, PV display window is
converted to operation mode.
• Pressing the key in the upper limit comparison value setting mode increases
the upper limit comparison value of the SV display window.
• Pressing the key in the lower limit comparison value setting mode increases
the lower limit comparison value of the SV display window.
• If parameter D.TMR is ‘0’, there is no display conversion between PV display
window’s maximum value display mode and minimum value display mode
Connection diagram
LM3 connection diagram
: Alternating Current (AC)
** : Direct Current (DC) LM3 option output connection diagram
※ There is no output option for indicator only. LM6 connection diagram
: Alternating Current (AC)
** : Direct Current (DC) LM6 option output connection diagram
※ Non only (Indication option output)
Function mode
Function Mode Configuration
- The function mode consists of 4 parameter groups: P.FUN / P.EXP / P.OUT / P.OPT.
- P.FUN is a group of general function setting parameters.
- P.EXP is an extended function setting parameter group.
- P.OUT is a group of output function setting parameters related to the output model.
- P.OPT is a group of optional function setting parameters related to transmission output and communication output models.
- Press the key for more than 3 seconds in the operation mode to enter the function mode.
- In function mode, if key is pressed for more than 3 seconds, all parameter values are saved and operation mode is restored.
- FREQ is displayed only on AC models (when FREQ is selected, AC.TY / EX.IN / K-ZO is not displayed)
- AC.TY displayed on AC models only (AVG / RMS selected)
- P.OUT is displayed only on the output model (if O-MD is OFF, S.TMR / HYS is not displayed)
- P.OPT is displayed only in transmission output and communication output models
- PV.SH/PV.SL is displayed only in transmission output model
- S-NO / BPS / PTY / RWT / CWP are displayed only in communication output model
P.FUN Parameter group P.EXP Parameter group P.OUT Parameter group (Displayed only on output models) P.OPT Parameter group (Displayed only in transmission output model and communication output model.)
Output mode
※For detailed explanation, please visit our website
(www.hanyoungnux.com)
Please refer to the communication and user manual in the archive.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>