Package Contents
Thank you for purchasing PLANET L2+ Industrial Managed Switch, 1GS-5225
Serfes. The number of the ports of these models is as follows:
|
GbE Copper Ports
| PoE Ports| GbE SFP Ports
---|---|---|---
at/af| bt| 1G| 2.5G
IGS-5225-4T2S| 4| –| –| –| 2
IGS-5225-4P2S| 4| 4| –| 2| –
IGS-5225-4UP1T2S| 5| –| 4| –| 2
IGS-5225-8P4S| 8| 8| –| 2| 2
IGS-5225-8P4S-12V| 8| 8| –| 2| 2
IGS-5225-8P2T2S| 10| 8| –| –| 2
IGS-5225-8P2T4S| 10| 8| –| 2| 2
bt: Compatible with 802.3at/af PoE
2.5G: Compatible with 1000BASE-SX/LX/BX SFP transceiver
“Industrial Managed Switch” mentioned in this Quick Installation Guide refers
to the above models.
Open the box of the Industrial Managed Switch and carefully unpack it.
The box should contain the following items for each model of the Industrial
Managed Switches:
| The Industrial Managed Switch| Quick Installation Guide Sheet| Wall Mounting
Kit| DB9 to RJ45, RS232 Console Cable| RJ45 Dust Cap| SFP Dust Cap
---|---|---|---|---|---|---
IGS-5225- 4T2S| ∎| ∎| ∎| ∎| 5| 2
IGS-5225- 4P2S| ∎| ∎| ∎| ∎| 5| 2
IGS-5225- 4UP1T2S| ∎| ∎| ∎| ∎| 6| 2
IGS-5225- 8P4S| ∎| ∎| ∎| ∎| 9| 4
IGS-5225- 8P4S-12V| ∎| ∎| ∎| ∎| 9| 4
IGS-5225- 8P2T2S| ∎| ∎| ∎| ∎| 11| 2
IGS-5225- 8P2T4S| ∎| ∎| ∎| ∎| 11| 4
If any of these are missing or damaged, please contact your dealer
immediately.
If possble, retain the carton including the original packing materials to
enable you to repack the product in case there is a need to return it to us
for repair.
Requirements
The Industrial Managed Switch provides remote login interface for management purposes. The following equipment is necessary for further management:
-
Workstations running Windows 10/11, MAC OS 10.15 or later, Linux, UNIX, or other platforms are compatible with TCP/IP protocols.
-
Workstations are installed with Ethemet NIC (Network Interface Card)
-
Serial Port Connection (Terminal)
» The above Workstations come with COM Port (DB9) or USB-to-RS232 converter.The above Workstations have been installed with terminal emulator, such as putty or tera term.
Serial cable – one end is attached to the RS232 serial port, while the other end to the console port of the Industrial Managed Switch. -
Ethemet Port Connection
Network cables – Use standard network (UTP) cables with RJ45 connec- tors.
» The above PC is installed with Web browser.
It is recommended to use Chrome 98.0.xxx or above to access the Industrial Managed Switch.
Wiring the Power Inputs
The Upper Panel of the Industrial Managed Switch comes with one 6-contact terminal block. Please follow the steps below to insert the power wire.
-
Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or Contacts 5 and 6 for Power 2.
∎ 1GS-5225-8P4S/1GS-5225-8P2T2S/1GS-5225-8P2T4S: DC 48~54V Figure 3-1: 1GS-5225-8P4S/IGS-5225-8P2T2S/1GS-5225-8P2T4S Upper Panel
∎ IGS-5225-4UP1T2S: DC 48~54V ∎ IGS-5225-4T2S: DC 12~48V, AC 24V
∎ IGS-5225-4P2S: DC 48~56V ∎ IGS-5225-8P4S-12V: DC 12~54V -
Tighten the wire-clamp screws for preventing the wires from loosening.
| Positive (+) Pin| Negative (-) Pin
---|---|---
IGS-5225 Series| Pin 1/5| Pin 2/6
- The wire gauge for the terminal block should be in the range from 12 to 24 AWG.
- Please check the wire AWG Ampere specification before connecting PLANET Industrial Managed Switch.
PWR1 and PWR2 must provide the same DC voltage for pow’ load balance while
operating with dual power input.
3.1 Grounding the Device
Users MUST complete grounding wired with the device; otherwise, a sudden
lightning could cause fatal damage to the device.
EMD (Lightning) damage is not covered under warranty.
Terminal Setup
To configure the system, connect a serial cable to a COM port on a PC or
notebook computer and to RI45 type serial (console) port of the Industrial
Managed Switch. The console port of the Industrial Managed Switch is DCE
already, so that you can connect the console port directly through PC without
the need of null modem.
1GS Industrial Managed Switch
A terminal program is required to make the software connected to the 1GS-5225 series Industrial Managed Switch.
- Run terminal program on the OS.
- When the following screen appears, make sure that the COM port should be configured as:
∎ Baud: 115200
∎ Parity: None
∎ Data bits: 8
∎ Stop bits: 1
∎ Flow control: None
4.1. Logging on to the Console
Once the terminal has been connected to the device, power on the Industrial
Managed Switch and the terminal will display “running testing procedures”.
The following console screen is based on the 1GS5225-4UP1T2S. The display of
the other 1GS-5225 series is the Same as that of the IGS-5225-4UP1T2S.
Then, the following message asks to log in user name and password. The default
user name and password are shown as follows and the login screen in Figure 4-1
appears
Userame: admin
Password: admin
The user can now enter commands to manage the Industrial Managed Switch.
For a detailed description of the commands, please refer to the following
chapters.
- For security reason, please change and memorize the new password after this first setup.
- 0nly accept command in lowercase letter under console interace.
4.2 Configuring IP address
The Industrial Managed Switch is shipped with default IP address shown below:
IP Address: 192.168.0.100
Subnet Mask: 255.255.255.0
To check the current IP address or modify a new IP address for the Switch,
please use the procedure as follows:
-
Display of the current IP Address
1. At the “#” prompt, enter “show ip interface brief”.
2. The screen displays the current IP address shown in Figure 4-2. -
Configuration of the IP Address
3. At the “#” prompt, enter the following command and pressas shown in Figure 4-3.
1GS-5225-4UP1T25# configure terminal
1GS-5225-4UP1T25 config)# interface vian 1
1GS-5225-4UP1T2S(config-if-vian)# ip address 192.168.1.100 255.255.255.0
The previous command would apply the following settings for the Industrial Managed Switch.
IP Address: 192.168.1.100
Subnet Mask: 255.255.255.0![EMQ IGS-5225-4T2S Gigabit Managed Ethernet Switch
-
Fig3](https://manuals.plus/wp-content/uploads/2023/12/EMQ-IGS-5225-4T2S- Gigabit-Managed-Ethernet-Switch-Fig3.jpg)4. Repeat step 1 to check if the IP address has changed.
- Store the current switch configuration
5. At the “#” prompt, enter the following command and press.
- Store the current switch configuration
# copy running-config startup-config
If the IP is successfully configured, the Industrial Managed Switch will apply
the new IP address setting immediately. You can access the Web interface of
the Industrial Managed Switch through the new IP address.
If you are not familiar with the console command or the related parameter,
enter “help” anytime in console to get the help description.
Starting Web Management
The following shows how to start up the Web Management of the Industrial
Managed Switch. Note the Industrial Managed Switch is configured through an
Ethernet connection. Please make sure the manager PC must be set to the same
IP subnet address.
For example, the default IP address of the Industrial Managed Switch is
192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a
number between 1 and 254, except 100), and the default subnet mask is
255.255.255.0.
5.1 Logging in to the Industrial Managed Switch
-
Use Chrome 98.0.xxx or above for Web browser and enter IP address https://192.168.0.100 (the factory-default IP address) to access the Web interface.
-
When the following dialog box appears, please enter the default user name “admin” and password “admin” (or the password you have changed before) as shown in Figure 5-2.
Default IP Address: 192.168.0.100
Default User Name: admin
Default Password: admin -
After entering the password, the main screen appears as shown in Figure 5-3.
The Industrial Managed Switch Menu on the top and left of the Web page lets you access all the functions and status the Industrial Managed Switch provides. The Switch Menu always contains one or more buttons, such as “System”, “Switching”, “QoS”, “Security”, “PoE”, “Ring”, “ONVIF” and “Maintenance”.
Now, you can use the Web management interface to continue the Switch
management. Please refer to the user manual for more.
If you are not familiar with Switch functions or the related parameter, press
[ ] “Help icon” like the following anytime on the Web page to get the help
description.
5.2 Saving Configuration via Web
To save all applied changes and set the current configuration as a startup
configuration, the startup-configuration file will be loaded automatically
across a system reboot.
- dlick the Save icon on the top Switch Menu bar.
- Press the “Save Configuration” button.
- 0r the other way to save the setting is to Click Maintenance, Save Startup Config.
Recovering Back to Default Configuration
To reset the IP address to the default IP address “192.168.0.100” and the user password to factory default mode (default password is admin), press the hardware reset button on the front panel for about 10 seconds. After the device is rebooted, you can log in the management Web interface within the same subnet of 192.168.0.xx and default password. Be noted that all the previous setups will be disappeared after the factory default reset is made.
|
---|---
Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ
resource on PLANET web site first to check if it could solve your issue. If
you need more support information, please contact PLANET switch support team.
PLANET online FAQs: https://www.planet.com.tw/en/support/fasq
Switch support team mail address:
support@planet.com.tw
1GS-5225-4T2S/1GS-5225-4P2S/1GS-5225-8P2T4S/1GS-5225-8P4S/1GS-52258P4S-
12V/1GS-5225-8P2T25/1GS-5225-4UP1T2S User’s Manual:
https://www.planet.com.tw/en/support/downloads?&method=keyword&keyword=IGS-5225&view=3#list
(Please select your switch model name from the Product Model drop-down menu)
Copyright © PLANET Technology Corp. 2023.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
Al other trademarks belong to their respective owners.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>