Satel CR-MF3 MIFARE Proximity Card Reader Installation Guide
- June 15, 2024
- Satel
Table of Contents
Satel CR-MF3 MIFARE Proximity Card Reader
Full manual is available on www.satel.pl. Scan the QR code to go to our website and download the manual.
The CR-MF3 reader can operate as:
- proximity card reader in the INTEGRA alarm system,
- proximity card reader in the ACCO access control system,
- proximity card reader in systems of other manufacturers,
- standalone door control module.
Before you mount the reader, program the settings required for the selected operating mode in the CR SOFT program. The exception is a reader that is to operate in the ACCO NET system and is to be connected to the ACCO-KP2 controller using the RS-485 bus (OSDP protocol). The OSDP protocol is supported by the ACCO-KP2 controllers with firmware version 1.01 (or newer). In that case, you can program the required settings in the ACCO Soft program (version 1.9 or newer).
Installation
The device should be installed by qualified personnel. Prior to installation, please read the full manual. Disconnect power before making any electrical connections.
- Open the reader enclosure.
- Connect the reader to the computer. Use the USB / RS-485 converter (e.g. ACCO-USB by SATEL). Follow the instructions in the converter manual. Do not connect more than 24 access control devices with the MIFARE card reader (CR-MF5 and CR-MF3) to the converter. The CR SOFT program may not be able to support more devices correctly.
- Program the reader in the CR SOFT program.
- Create a new project or open an existing project.
- Establish connection between the program and the device.
- Program the settings and upload them to the reader.
- Disconnect the reader from the computer.
- Run the cables to where you want to install the reader. To connect the RS-485 bus, we recommend using a UTP cable (unshielded twisted pair). To make other connections, use unshielded straight-through cables.
- Place the enclosure base against the wall and mark the location of mounting holes.
- Drill the holes in the wall for wall plugs (anchors).
- Run wires through the opening in the enclosure base.
- Use wall plugs and screws to secure the enclosure base to the wall. Select wall plugs specifically intended for the mounting surface (different for concrete or brick wall, different for plaster wall, etc.).
- Connect the wires to the reader terminals (see: “Description of terminals”).
- Close the reader enclosure.
The ACCO Soft program in version 1.9 (or newer) enables programming of all the required settings. If it is to be used, you can skip the steps 2-4.
Description of terminals
Description of terminals for reader in the INTEGRA / ACCO system
Terminal | Description |
---|---|
NC | not used |
C | not used |
NO | not used |
DATA/D1 | not used [EM-Marin interface] / data (1) [Wiegand interface] |
RSA | RS-485 bus terminal [OSDP] |
RSB | RS-485 bus terminal [OSDP] |
TMP | tamper output |
+12V | +12 VDC power input |
COM | common ground |
CLK/D0 | data [EM-Marin interface] / data (0) [Wiegand interface] |
IN1 | programmable input [EM-Marin / Wiegand interface] |
IN2 | programmable input [EM-Marin / Wiegand interface] |
IN3 | programmable input [EM-Marin / Wiegand interface] |
BELL | not used |
Description of terminals for reader in other manufacturer’s system
Terminal | Description |
---|---|
NC | not used |
C | not used |
NO | not used |
DATA/D1 | data (1) [Wiegand interface] |
RSA | RS-485 bus terminal [OSDP] |
RSB | RS-485 bus terminal [OSDP] |
TMP | tamper output |
+12V | +12 VDC power input |
COM | common ground |
CLK/D0 | data (0) [Wiegand interface] |
IN1 | programmable input [Wiegand interface] |
IN2 | programmable input [Wiegand interface] |
IN3 | programmable input [Wiegand interface] |
BELL | not used |
Description of terminals for the standalone door control module
Terminal | Description |
---|---|
NC | relay output normally closed contact |
C | relay output common contact |
NO | relay output normally open contact |
DATA/D1 | not used |
RSA | RS-485 bus terminal [OSDP] |
RSB | RS-485 bus terminal [OSDP] |
TMP | tamper output |
+12V | +12 VDC power input |
COM | common ground |
CLK/D0 | not used |
IN1 | door status input |
IN2 | request-to-exit input |
IN3 | not used |
BELL | not used |
The declaration of conformity may be consulted at www.satel.pl/ce
SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gdańsk • POLAND tel. +48 58 320 94 00 www.satel.pl