amazon commercial B09WRL4B4V Dimmer Light Switch User Manual

June 15, 2024
amazon commercial

amazon commercial B09WRL4B4V Dimmer Light Switch

amazon-commercial-B09WRL4B4V-Dimmer-Light-Switch-
product

Product Description

  • a. HOT wire (black)
  • b. GROUND wire (green)
  • c. LOAD wire 1 (red) (for 3-way connections only)
  • d. LOAD wire 2 (red)
  • e. Machine screw x2
  • f. Twist-on wire connector x5
  • g. Dimmer slider
  • h. Adjuster dial (for sensitivity)
  • i. On/off switch

Important Safeguards

  • Read these instructions carefully and retain them for future use. If this product is passed to a third party, then these instructions must be included.

When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and/ or injury to persons including the following:

WARNING

  • Risk of electric shock! Do not install the product near wet locations such as kitchens or baths.
  • Do not use the product in General Patient
  • Care Areas or Critical Patient Care Areas. They have not been evaluated for use where Article 517 of the National Electrical Code requires a Hospital Grade component.

CAUTION

  • To reduce the risk of overheating and possible damage to other equipment, do not install to control a receptacle, a motor-operated appliance, a fluorescent lighting fixture, or a transformer-supplied appliance.
  • FOR CONTROL OF PERMANENTLY INSTALLED INCANDESCENT/HALOGEN, CFL, OR LED LAMP FIXTURES ONLY.

The installation must comply with all applicable local or national codes, including the latest edition of the following standards:

  • For US: ANSI/NFPA70, National Electrical Code (NEC)

  • For Canada: CSA C22.I, Parts I & II, Canadian Electrical Code

  • For Mexico: Mexican Electrical Code [Instalaciones

  • Eléctricas (utilizaciån), NOM-OOI -SEDE].

  • It is recommended that a qualified electrician perform the installation, especially if you are unsure about any part of these instructions.

  • This product is rated 120 V AC and must be connected to a suitable power source.

  • Do not install near water or heat sources.

  • Contact the municipal building department to learn about applicable local codes, permits and/or inspections.

  • Install only in a suitable UL-listed switch box.

  • For supply connection, use wires rated for at least 167 OF (75 oc).
    For supply connections, use copper wires of 18 AWG.

  • The maximum wire length between the product and the lamp fixture should not exceed 98′ (30 m).

  • Do not attempt to disassemble, repair, or modify the product. For indoor use only. SAVE THESE INSTRUCTIONS

Symbols Explanation

  • Use copper wire only.
  • Do not use aluminum wire.

Before First Use

DANGER

Risk of suffocation! Keep any packaging materials away from children and pets — these materials are a potential source of danger, e.g. suffocation.

  • Remove all the packing materials.
  • Remove and review all components before use.
  • Check the product for transport damages.
  • Before connecting the product to the power supply, check that the power supply voltage and current rating correspond with the power supply details shown on the product rating label.

Intended Use

  • This product is intended to be used as a wall switch with a dimming function. It is intended to replace a standard switch receptacle.amazon-commercial-B09WRL4B4V-Dimmer-Light-Switch-fig-1 \(12\)
  • This product is intended to be used in dry indoor areas only.

Electrical Wiring

DANGER

  • Risk of fire, electric shock or death! Switch off the power at the circuit breaker or fuse and test that power is off before installation.

WARNING

  • Risk of electric shock! When there are no grounding means in the switch box, consult an electrician. Do not install the product without a proper ground connection.

Tools needed

amazon-commercial-B09WRL4B4V-Dimmer-Light-Switch-fig-1
\(14\)

Remove existing switch(es)

  1. Unscrew and remove the existing wall plate (Fig. 1).
  2. Unscrew and remove the existing switch receptacle (Fig. 2).amazon-commercial-B09WRL4B4V-Dimmer-Light-Switch-fig-1 \(1\)

Single pole connection

  • Single pole connection is designed for scenarios where 1 lamp fixture is controlled with 1 switch (Fig. 3).
  • The LOAD wire 1 (C) is not used for a single pole connection.

For a detailed wiring diagram, refer to the wiring instructions sheet provided.

  1. Verify that the switch box has these wires:

HOT **** (usually black)

GROUND| (usually green, yellow, and green or stripped bare copper}
LOAD| (usually red)

If any of the wires are missing or have a different color, stop the
installation and contact a professional electrician.

  1. Disconnect the wires from the existing switch.
  2. If needed, strip wires to 7/16″ (11 mm).
  3. Connect the GROUND wire (green) (B) to the GROUND wire from the breaker box.
  4. Connect the HOT wire (black) (A) to the 120 V HOT wire from the breaker box.
  5. Connect the LOAD 2 (red) wire (D) to the LOAD wire from the lamp fixture.
    • Notice: Insert wires into the twist-on wire connector (F) then twist clockwise. Make sure the connection is tight by gently pulling all the cables one by one. Make sure no bare wire is shown below the twist-on wire connector (F).
  6. After the connections are completed, switch on the power at the circuit breaker or fuse. Test if the switch works.

3-way connection

A 3-way connection is designed for scenarios where I lamp fixture is controlled by 2 switches (Fig. 5).

For a detailed wiring diagram, refer to the wiring instructions sheet provided.

  1. Verify that the dimmer switch box has these wires:

HOT **** I (usually black)

GROUND ** (usually green, yellow, and green or stripped bare copper)
LOAD** x2             (usually red)

If any of the wires are missing or have different colors, stop the installation and contact a professional electrician.

  1. Disconnect the wires from the existing switch in the dimmer switch box.
  2. If needed, strip wires to 7/16″ (11 mm).
  3. Connect the GROUND wire (green) (B) to the GROUND wire from the breaker box.
  4. Connect the HOT wire (black) (A) to the 120 V HOT wire from the breaker box.
  5. Connect the LOAD I (red) wire (C) and the LOAD 2 (red) wire (D) to the LOAD terminals of the 3-way switch (not provided). Follow the directions on the 3-way switch installation instructions to make sure the connections are correct.
  6. If there is any doubt on how to connect the switches, stop the installation and contact a professional electrician.
    • Notice: Insert wires into the twist-on wire connector (F) then twist clockwise. Make sure the connection is tight by gently pulling all the cables one by one. Make sure no bare wire is shown below the twist-on wire connector (F).
  7. After the connections are completed, switch on the power at the circuit breaker or fuse. Test if the switches work.

Adjust Dimming Range

  1. Switch on the lamp fixture with the on/off switch (I).
  2. Set the dimmer slider (G) to the left.
  3. Rotate the adjuster dial (H) counter-clockwise until the brightness is the lowest without the lamp fixture going off or flickering (Fig. 7).
  4. Switch off the lamp fixture with the on/off switch (I), then switch on again.
  5. If the lamp fixture does not switch on properly or is flickering, rotate the adjuster dial (H) clockwise.
  6. Repeat step 4 and 5 until the lamp fixture is dimming properly.

Install Wall Plate

If the product was installed next to other switches, you will need to purchase a wall plate with the correct size/number of openings to accommodate all the units.

  1. Switch off the power at circuit breaker or fuse and test that power is off with a voltage detector.
  2. Insert the main unit into the switch box being careful not to pinch any wires. Arrange the wires and tuck them in neatly.
  3. With the “UP” marking facing up, attach the main unit to the switch box with the 2 machine screws (E) (Fig. 8).
  4. Install the wall plate (not provided) on the main unit (Fig. 9). Installation method of the wall plate may differ depending on the type of wall plate used. Refer to its installation instructions.
  5. After the installation, switch on the power at the circuit breaker or fuse. Test if the switch works.

Operation

  • Switch on/off
    • Flip the on/off switch (I) to switch the lamp fixture on/off.
  • Dimness setting
    • Slide the dimmer slider (G) to the left side to dim the lamp fixture or to the right side to brighten the lamp fixture.

Cleaning and Maintenance

DANGER

  • Risk of fire, electric shock, or death!
  • Switch off the power at the circuit breaker or fuse and test that power is off before servicing.

Cleaning

  • To clean the product, wipe with a soft, slightly damp cloth.
  • Wipe the product dry after cleaning.
  • Never use corrosive detergents, wire brushes, abrasive scourers, or metal or sharp utensils to clean the product.

Frequently Asked Questions

amazon-commercial-B09WRL4B4V-Dimmer-Light-Switch-fig-1
\(16\)

Specifications

amazon-commercial-B09WRL4B4V-Dimmer-Light-Switch-fig-1
\(17\)

Installing 2 or 3 products in the multiple gang boxes reduces the product’s maximum wattage rating for incandescent/halogen fixtures as per the below table:

amazon-commercial-B09WRL4B4V-Dimmer-Light-Switch-fig-1
\(18\)

Feedback and Help

  • We would love to hear your feedback. To ensure we are providing the best customer experience possible, please consider writing a customer review.
  • Scan the QR Code below with your phone camera or QR reader:
  • If you need help with your Amazon Commercial product, please use the website or number below.
  • amazon.com/gp/help/customer/contact-us.
  • +1 877-485-0385
  • amazon.com/AmazonCommerciaI.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

amazon commercial User Manuals

Related Manuals