ardo Calypso Double Plus Breastpump User Guide

June 15, 2024
ardo

ardo Calypso Double Plus Breastpump User Guide
ardo Calypso Double Plus Breastpump

Calypso Troubleshooting

Tip – if the Calypso unit goes into error mode it could be your tubes may have been restricted. Disconnect pumpset, plug pump in with nothing attached, and if the pump starts without the error code attach the pumpset back on and happy pumping.
Calypso Troubleshooting

Calypso Breastpump

At Ardo we understand what it is like to be a new mum and feel overwhelmed by having a new born baby and the need to express.
This leafl et illustrates how to use the pump, assemble the pump sets, plus a troubleshooting section.

View our range of expressing and information videos here.

SCAN ME

The 3 P‘s for successful pumping!
Positive Emotions – hearing, seeing, smelling or skin to skin with your baby. Don’t look at the pump!
Perform Massage – massaging the breast before pumping encourages the let- down refl ex.
Professional Breastpump – NHS approved, Class 2 medical device, adjustable cycles and vacuum,\ single or double pumping option.

Assembling the Pumpset

  1. Clean components before use (excluding lid & tubing) and ensure all parts are FULLY DRY before assembly. NB see important notes below about the lip valve.
    Assembling the Pumpset

  2. Take the breast shell and screw it onto the bottle.
    Assembling the Pumpset

  3. Place the flexible membrane pot, smooth side out, in the top of the breast shell and press down firmly
    Assembling the Pumpset

  4. Press the green top on the breast shell and attach the tubing onto the back of the lid.
    Assembling the Pumpset

  5. Line up the central mark on the green top with the mark on the breast shell , and gently turn the top to the right.
    Assembling the Pumpset

  6. Double Pumping – attach two tubes to the connector.
    Single Pumping – attach one tube to the connector and ensure the other stopper is closed.
    Assembling the Pumpset

IMPORTANT INFORMATION
Lip Valve – Attach and remove this part carefully from the breast shell as indicated. DO NOT use a cleaning brush to clean this valve, just rinse before sterilizing. If the valve is damaged the breast pump will not work. Spare valve(s) are included with the pump set.
Important Information

Operating the Calypso Breastpump

  1. Connect the power adapter to the back of the pump and the pumpset/s to the front of the pump unit.
    Operating the Calypso Breastpump

  2. Put the breastshell/s to the breast. Switch on the pump by pressing th eon/off switch. The green LED light will come on. The vacuum & cycles are set at the lowest level.
    Operating the Calypso Breastpump

  3. Cycles is stimulation mode – Brief massaging before expressing will encourage milk flow and stimulate the milk ejection reflex (let down). Setting the cycles high and the vacuum low will replicate the rapid sucking and low suction the baby does when feeding.
    Operating the Calypso Breastpump

  4. Vacuum is expressing mode – ONLY when ‘let down’ occurs and milk is released do you increase the vacuum and reduce the cycles. Find the most comfortable level for you. If your milk flow stops we suggest you turn the pump off, massage your breast and restart again in the stimulation mode (3).
    Operating the Calypso Breastpump

IMPORTANT – vary the cycles and vacuum levels to maintain the milk flow and comfort, as this mimics the natural sucking rhythm of the baby.

Symbol
BPA free
Symbol
WHO code complia

If you need any further help please refer to the Calypso user manual, visit our website for videos and guides, or contact us for an online consultation.