elk Home 52323-2 Light Pelham Satin Brass Flush Mount User Manual
- June 15, 2024
- elk HOME
Table of Contents
ANY QUESTIONS CALL: 800-613-3261
M-F 8:00AM-6:00PM ET
ITEM#: 52303/2
ITEM#: 52313/2
ITEM#: 52323/2
WARNING: DISCONNECT POWER AT THE MAIN FUSE BOX BEFORE INSTALLATION.
WARNING:
This fixture is intended for installation in accordance with the National
Electrical Code (NEC) and all local code specifications. If you are not
familiar with code requirements, installation by a certified electrician is
recommended.
Before assembly, remove all parts and part packages from box. If anything is missing, please contact the retailer from which the product was purchased.
1. Carefully pull house wires out of junction box so they are easily
accessible during installation.
2. Position mounting bracket (A) so threaded ends of attached fixture
mounting screws (E) are facing down towards floor.
3. Thread each junction box screw (B) into holes in mounting bracket (A) and
into hole in junction box. Tighten junction box screws (B) to secure mounting
bracket (A) to junction box.
CAUTION: Make sure house wires are pulled completely through hole in
mounting bracket.
DO NOT pinch wires between mounting bracket and ceiling.
- JUNCTION BOX
4. Strip 3/4” of insulation from ends of fixture wires.
5. Slightly loosen ground screw on mounting bracket (A). Do not completely
remove ground screw. Wrap house ground wire (copper) around ground screw,
leaving enough ground wire to attach to fixture ground wire. Twist end of
fixture ground wire and end of house ground wire (copper) together. Twist wire
nut (C) onto ends of wires. Completely tighten wire nut (C). Reference chart
below for correct wire connections.
Connect Supply (House) Ground Copper Wire to:
Bare Copper Wire or,
Bare Silver Wire or,
Green Insulated Wire.
- GROUND SCREW
- HOUSE GROUND WIRE (COPPER)
- FIXTURE GROUND WIRE
6. Twist end of house lead wire (black) and end of fixture lead wire
together. Twist wire nut (C) onto ends of wires. Completely tighten wire nut
(C). Twist end of house neutral wire (white) and end of fixture neutral wire
together. Twist wire nut (C) onto ends of wires. Completely tighten wire nut
(C). Reference chart to the right for correct wire connections.
7. Wrap electrical tape (not included) around wire nuts (C) and wires. Ensure
wires are securely fastened into wire nuts.
8. Carefully push all wires and wire nuts into junction box.
Connect Black Lead Supply (House) Wire to:
| Connect White Neutral Supply (House) Wire to:
---|---
Black Wire or, |
White Wire or,
*Parallel Cord (Round and Smooth) or,
| *Parallel Cord (Square and Ridged) or,
No printed words on wire insulation or,|
Printed words on wire insulation or,
Insulated Wire (other than green) with Copper Conductor.
| Insulated Wire (other than green) with Silver Conductor.
*When parallel wire (SPT 1 & SPT 2) is used:
The lead wire is round in shape or smooth.
The neutral wire is square in shape or ridged.
- FIXTURE LEAD WIRE
- FIXTURE GROUND WIRE
- FIXTURE NEUTRAL WIRE
- HOUSE LEAD WIRE (BLACK)
- HOUSE GROUND WIRE (COPPER)
- HOUSE NEUTRAL WIRE (WHITE)
9. Carefully raise fixture up to ceiling. Place canopy (D) of fixture over
mounting bracket (A). Pass holes in canopy (D) over ends of fixture mounting
screws (E).
10. Screw one threaded cap (F) onto end of each fixture mounting screw (E).
Tighten threaded caps (F) to secure fixture to ceiling. DO NOT over tighten.
11. Screw recommended bulbs (E26 Edison bulb type, not included) into
sockets. Verify correct bulb wattage marked on socket of fixture.
WARNING: DO NOT exceed maximum bulb wattage.
12. Raise diffuser (K) up to fixture. Thread hex nut on diffuser (K) onto
threaded pipe in center of shade. DO NOT over tighten.
- BULB
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>