Safety & Warnings
CAUTION :
The air conditioner must have its own fuse or circuit breaker. No other device
or unit should be operated on the same fuse or circuit breaker. To avoid the
possibility of personal injury, disconnect power to the unit before installing
or servicing.
Electric Shock Hazard:
The air conditioner has a serial rating voltage. It must have its own fuse
or circuit breaker and no other device or unit should be operated on the fuse
or circuit breaker. To avoid the possibility of personal injury, disconnect
power to the unit before installing or servicing.
Overview
The window wall air conditioner consists of various components including:
- Front Cover
- Air inlet grille (Indoor)
- Cabinet
- Air outlet grille (Indoor)
- Air inlet grille (Outdoor)
- Vent Lever
- Control Panel
- Air filter
- Remote Control
Installation
Location: The air conditioner should be installed in a location that meets the following requirements:
- The wall thickness should be less than 210mm.
- The distance between the bottom of the air conditioner and the floor should be more than 55mm.
- If the wall thickness is more than 210mm, scrape the wall to meet the required thickness.
Installation Instructions:
- Remove the front panel, air filter, and screws at the bottom of the front panel.
- Remove the screws in the chassis-fixing board and cabinet.
- Grasp the handle on the front of the chassis and carefully slide the air conditioner unit out of the cabinet.
- Install the drain tube connection into the provided hole at the rear of the air conditioner chassis. Choose between bottom drainage or rear drainage method.
- Install the air conditioner cabinet on the installation shelf using screws.
- Carefully slide the unit back into the cabinet.
- Reinstall the retaining bracket, front panel, and mounting screws.
- Reinstall the air filter.
Operation
Control Panel Buttons:
Button | Function |
---|---|
Adjust Airflow Direction | Used to adjust airflow direction. |
ON/OFF | Used to turn the air conditioner ON/OFF. |
SLEEP | Used to activate the SLEEP function. |
Control Panel Symbols:
Button | Function |
---|---|
Timer | Timer function is activated. |
Cooling | Cooling mode is activated. |
Heating | Heating mode is activated. |
Fan only | Fan only mode is activated. |
Sleep | Sleep mode is activated. |
Display set temperature/display set timer | Displays the set temperature or set |
timer.
Low fan speed| Low fan speed is selected.
Mid fan speed| Medium fan speed is selected.
High fan speed| High fan speed is selected.
Auto fan speed| Automatic fan speed is selected.
Compressor running| The compressor is running.
Cleaning & Care
Refer to the user manual for detailed instructions on how to clean and care
for the window wall air conditioner.
FAQ
What should I do if the wall thickness is more than 210mm?
If the wall thickness is more than 210mm, you need to scrape the wall to meet
the required thickness.
Can I operate other devices or units on the same fuse or circuit breaker as
the air conditioner?
No, the air conditioner must have its own fuse or circuit breaker. No other
device or unit should be operated on the same fuse or circuit breaker.
SAFETY & WARNINGS
- Ensure to read all instructions in this user guide prior to first use. Retain this user guide for future reference. Misuse may cause injuries to people and damage property.
- IMPORTANT: All wiring must comply with local and national electrical codes and must be installed by a licenced electrician. If you have any questions regarding the following instructions, contact a licenced electrician.
- Check available power supply and resolve any wiring problems before installing and operating this unit.
- For your safety and protection, this unit is grounded through the power cord when plugged into a matching wall outlet. If you are not sure whether your wall outlet is properly grounded, please consult a qualified electrician.
- The rating plate on the unit contains electrical and other technical data. The rating plate is located on the right side of the unit. Make sure to use correct power supply according to the rating plate of your air conditioner.
- WARNING : This air conditioner can be used by children aged from 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Children should be supervised to ensure that they do not play with the appliance.
- Do not allow children to play with the air conditioner.
- Cleaning and user maintenance shall not be performed by children without supervision.
- To ensure safety, always switch off and cut the power supply when the air conditioner is not in use for long time.
- If the power cord is damaged, cease use immediately and contact help.Kogan.com for support.
- Always switch off and cut the power supply before performing any maintenance or cleaning. Failure to do so may cause electric shock or damage.
- Do not attempt to repair the air conditioner yourself. Incorrect repairs may cause fires or explosions. Contact a qualified service technician for all service requirements.
- Do not attempt to disassemble the air conditioner yourself.
- Do not use the air conditioner during lightning storms. The power supply should be cut in time to prevent danger.
- Do not put hands or any objects into the air inlet or air outlet. This may cause personal injury or damage to the air conditioner.
- Do not use the air conditioner for other purposes, (for example, drying clothes, preserving foods).
CAUTION:
- Before installation, turn off the operation switch and disconnect the power cord.
- The appliance is fitted with means for disconnection from the supply mains, having a contact separation in all poles that provides full disconnection under overvoltage category III conditions, and these means must be incorporated in the fixed wiring in accordance with the wiring rules.
Electric Shock Hazard
The air conditioner has a serial rating voltage. It must have its own fuse
or circuit breaker and no other device or unit should be operated on the fuse
or circuit breaker. To avoid the possibility of personal injury, disconnect
power to the unit before installing or servicing.
CAUTION:
- The installation parts must be protected against corrosion, especially in cases where the air conditioner will be installed near the sea or hot springs.
- Do not install the air conditioner in a place where flammable gas leaks are possible. Ensure any combustible surfaces and materials are at least 10cm away from the unit during heating mode.
- The range of external static pressures at which the appliance has been tested is 0- 5Pa.
Operation
- Check the capacity of wiring and power outlet. Do not use the power outlet with other appliances connected.
- Ground the air conditioner to prevent danger of electric shock.
- Connect the air conditioner with power source securely. Use the fuse as below.
OVERVIEW
INSTALLATION
Location
- Select a location that can support the weight of the air conditioner and will not cause increased operation noise or vibration.
- Avoid direct sunlight for efficient cooling.
- Select a place where there are no obstructions near the air inlet and outlet.
Installation instructions
-
Remove the front panel. (Fig.5)
- Remove the air filter. (Fig.6)
- Remove screws at the bottom of the front panel. (Fig.7)
- Open the panel cover.
-
Remove the screws in the chassis-fixing board and cabinet. Some models have two more screws on the back of the cabinet. (Fig.8)
-
Grasp the handle on the front of the chassis and carefully slide the air conditioner unit out of the cabinet. (Fig.9)
-
Install the drain tube connection into the hole provided at the rear of the air conditioner chassis. (Fig.10) (Available for single drainage method: rear drainage only).
-
Bottom drainage:
The drain tray is fixed in position using four screws, and the flare nut is used to block the rear drainage hole. (Fig.11) -
Rear drainage:
Use the flare nut to block the bottom drainage hole and use a water outlet pipe to connect the rear drainage hole. Pay attention to the sealing ring to prevent water leakage. (Fig.12)
-
-
Install the air conditioner cabinet on the installation shelf (not included) with screws. (Fig.13)
-
Carefully slide the unit back into the cabinet. (Fig.14)
-
Reinstall the retaining bracket, front panel, and mounting screws. (Fig. 8, 7, 15)
-
Reinstall the air filter. (Fig.16)
Control panel buttons
Control panel
The below symbols turn on when the relevant mode is in use.
Remote control
The remote control transmits signals to the system. The unit will confirm the
command with a beep.
Button | Function |
---|---|
(TEMP UP) | Increase the temperature or time by 1 unit. |
(TEMP DOWN) | Decrease the temperature or time by 1 unit. |
ON/OFF | To switch the unit ON/OFF. |
FAN | To select the fan speed of AUTO/LOW/MID/HIGH. |
TIMER | Set or cancel timer operation. |
SLEEP | To activate the SLEEP function. |
MODE | To select the mode of operation. |
SWING | To activate/deactivate movement of the deflectors. |
ECO | To activate ECO mode. |
SUPER
| To activate/deactivate the SUPER function. This mode enables the unit to reach the pre-set temperature in the shortest time.
CLEANING & CARE
Air filter
- The air filter should be washed at least once a month. If the air filter remains full of dust, the air flow will decrease, and the cooling capacity will be reduced.
- The filter is behind the cover and can be pulled out from the right-hand side.
- Wash the air filter with water and mild detergent.
- Rinse with clean water and dry it before reinstalling.
CAUTION:
- Do not use hot water above 40°C for washing the air filter.
- Let the filter dry thoroughly in the shade before reinstalling. Do not expose it to direct sunlight.
- Do not operate the air conditioner with the filter removed.
Extended downtime maintenance
- Operate the fan alone (“LOW FAN” or “HIGH FAN”) for half a day to dry out the inside of the unit.
- Turn off power and remove plug from power outlet.
- When you are about to use the air conditioner after an extended downtime period, clean the condenser (at the rear) and evaporator (at the front) fins by using a soft brush or vacuum cleaner.
CAUTION : Be careful not to damage the fins during cleaning.
Air cleaning filter
The air cleaning filter is attached to the air filter. Wash the air cleaning
filter as well when washing the air filter.
Front cover
- The front cover will accumulate dirt and dust. To clean it, wipe it with a soft dry cloth. When it is excessively dirty, wipe it with a soft cloth dampened with warm water or mild soap and then wipe it again thoroughly with a soft dry cloth.
- Never use hot water above 50°C, benzene, gasoline, acid, thinner or brushes to wipe off dirt, as they will damage the plastic surface and the coating.
SPECIFICATIONS
Rated volts | 250 |
---|---|
Amps | 3.15 |
Climate class rating | **** |
T1
| ambient temperature for cooling: 18~43°C.
ambient temperature for heating: -5~20°C.
T3
| ambient temperature for cooling: 25~52°C.
ambient temperature for heating: -5~20°C.
Disposal
- Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
- Contact your local government for information regarding the collection systems available.
- If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
Need more information?
We hope that this user guide has given you the assistance needed for a simple
set-up. For the most up-to-date guide for your product, as well as any
additional assistance you may require, head online to
help.kogan.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>