Rheem RP1624AJ2NA Split System Air Conditioners And Heat Pumps User Manual
- June 13, 2024
- Rheem
Table of Contents
- Rheem RP1624AJ2NA Split System Air Conditioners And Heat Pumps
- Product Information
- Product Usage Instructions
- Standard Feature Table
- Features and Benefits
- General Data
- Accessories
- Weighted Sound Power Level (dBA)
- Unit Dimensions
- Application Guidelines
- Refrigerant Line Size Information
- GENERAL TERMS OF LIMITED WARRANTY*
- Documents / Resources
Rheem RP1624AJ2NA Split System Air Conditioners And Heat Pumps
Product Information
The RP16 is a split system air conditioner or heat pump manufactured by Rheem.
It is designed to provide optimal performance when properly sized and
installed. To meet Energy Star
requirements, it must be matched with appropriate coil components. For more
details, consult your Contractor or visit
www.energystar.gov.
Features and Benefits
- Standard Features: The RP16 comes with a range of standard features including various tonnages, SEER ratings, voltage types, and control options.
Available SKUs
The RP16 is available in the following models:
- RP1624AJ2NA: 2-ton capacity
- RP1636AJ2NA: 3-ton capacity
- RP1648AJ2NA: 4-ton capacity
- RP1660AJ2NA: 5-ton capacity
- RP1624AJ2NANOM: Export model for Mexico (R-410 refrigerant)
- RP1636AJ2NANOM: Export model for Mexico (R-410 refrigerant)
- RP1648AJ2NANOM: Export model for Mexico (R-410 refrigerant)
- RP1660AJ2NANOM: Export model for Mexico (R-410 refrigerant)
General Data
The general data for each model is as follows:
Model No.| Nominal Tonnage| Liquid Line OD (inches)| Suction Line OD (inches)|
Refrigerant (ounces)| Compressor Type| Outdoor Coil Net Face Area (Outer
Coil)| Outdoor Coil Net Face Area (Inner Coil)| Outdoor Coil Tube Diameter
(inches)| Outdoor Coil Number of Rows| Outdoor Coil Fins Per Inch| Outdoor Fan
Diameter (inches)| Outdoor Fan Number of Blades| Outdoor Fan Motor HP| Outdoor
Fan CFM| Outdoor Fan RPM| Outdoor Fan Watts| Shipping Weight (lbs)| Operating
Weight (lbs)
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
RP1624AJ2NA| 2| 0.375| 0| 137| General Data| 19.9| 0| 0.375| 1| 20| 0| 0| 0|
198| 0| 206| 0| 264| 0
RP1636AJ2NA| 3| 0.375| 0| 156| General Data| 19.9| 0| 0.375| 1| 20| 0| 0| 0|
198| 0| 206| 0| 264| 0
RP1648AJ2NA| 4| 0.375| 0| 196| General Data| 19.9| 0| 0.375| 1| 20| 0| 0| 0|
198| 0| 206| 0| 264| 0
RP1660AJ2NA| 5| 0.375| 0| 198| General Data| 19.9| 0| 0.375| 1| 20| 0| 0| 0|
198| 0| 206| 0| 264| 0
Product Usage Instructions
To ensure optimal performance and energy efficiency, follow these usage instructions:
- Proper Sizing: Ensure that the RP16 is properly sized for your cooling or heating needs. Consult your Contractor for assistance in determining the correct tonnage.
- Installation: Have the RP16 installed by a professional to ensure proper installation and performance.
- Coil Matching: The RP16 must be matched with appropriate coil components to meet Energy Star requirements. Consult your Contractor or visit www.energystar.gov for details.
- Maintenance: Regularly maintain the RP16 by cleaning the outdoor coil and keeping the surrounding area clear of debris.
- Warranty: The RP16 comes with a limited warranty. Refer to the warranty section in the user manual for more information.
- Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystar.gov.
Standard Feature Table
Standard Features
Feature| RP1624AJ2NA| RP1624AJ2NANOM| RP1636AJ2NA| RP1636AJ2NANOM|
RP1648AJ2NA| RP1648AJ2NANOM| RP1660AJ2NA
Capacity| 24| 24| 36| 36| 48| 48| 60
R-410A Refrigerant| Y| N| Y| N| Y| N| Y
SEER| 0| 16| 0| 16| 16| 16| 0
SEER2| 0| 16| 0| 16| 16| 16| 0
EER| 0| 13| 0| 13| 12.5| 12.5| 0
EER2| 0| 13| 0| 13| 12.5| 12.5| 0
Primary Compressor Type| 0| YES| 0| YES| 0| YES| 0
Alternate Compressor Type| 0| 0| 0| 0| 0| 0| 0
Field Installed Filter Drier| 0| Y| 0| Y| 0| Y| 0
Front Seating Service Valves| 0| Y| 0| Y| 0| Y| 0
Internal Pressure Relief Valve| 0| Y| 0| Y| 0| Y| 0
Internal Thermal Overload| 0| Y| 0| Y| 0| Y| 0
Long Line capability| 0| Y| 0| Y| 0| Y| 0
Low Ambient Capability With Kit| 0| Y| 0| Y| 0| Y| 0
Three Four Five Expanded Valve Space| 0| Y| 0| Y| 0| Y| 0
Composite Base pan| 0| Y| 0| Y| 0| Y| 0
Two Screw Control Box Access| 0| N| 0| N| 0| N| 0
Fifteen Inch Access To Internal Components| 0| Y| 0| Y| 0| Y| 0
Quick Release Louver Panel Design| 0| Y| 0| Y| 0| Y| 0
No Fasteners To Remove Along Bottom| 0| Y| 0| Y| 0| Y| 0
Optimized Ventura Airflow| 0| Y| 0| Y| 0| Y| 0
Single Row Condenser Coil| 0| Y| 0| Y| 0| Y| 0
Powder Coated Paint| 0| Y| 0| Y| 0| Y| 0
Rust Resistant Screws| 0| Y| 0| Y| 0| Y| 0
Qr Code| 0| Y| 0| Y| 0| Y| 0
External Gauge Ports| 0| Y| 0| Y| 0| Y| 0
Service Trays| 0| Y| 0| Y| 0| Y| 0
Standard Feature Table
Standard Features
Feature| RP1660AJ2NANOM
Capacity| 60
R-410A Refrigerant| N
SEER| 16
SEER2| 16
EER| 12.5
EER2| 12.5
Primary Compressor Type| YES
Alternate Compressor Type| 0
Field Installed Filter Drier| Y
Front Seating Service Valves| Y
Internal Pressure Relief Valve| Y
Internal Thermal Overload| Y
Long Line capability| Y
Low Ambient Capability With Kit| Y
Three Four Five Expanded Valve Space| Y
Composite Base pan| Y
Two Screw Control Box Access| N
Fifteen Inch Access To Internal Components| Y
Quick Release Louver Panel Design| Y
No Fasteners To Remove Along Bottom| Y
Optimized Venturi Airflow| Y
Single Row Condenser Coil| Y
Powder Coated Paint| Y
Rust Resistant Screws| Y
Qr Code| Y
External Gauge Ports| Y
Service Trays| Y
Features and Benefits
Air Conditioners
R| A| 16| 24| A| J| 1|
N| A|
Brand| Product Category| SEER| Capacity BTU/HR| Major
Series| Voltage| Type| Contols| Minor Series**|
Option Code
Rheem| A-Air Conditioners| 16-16 SEER| 18-18,000[5.28 kW]| A-1st Design|
J-1ph, 208-230/60| 1-Single Stage| N-NonCommunicating| A-1st Design| N/A
| | | 24-24,000[7.03 kW]| B-2nd Design| C-3ph, 208-230/60| | | B-2nd Design|
| | | 30-30,000[8.79 kW]| | | | | |
| | | 36-36,000[10.55 kW]| | | | | |
| | | 42-42,000[12.31 kW]| | | | | |
| | | 48-48,000[14.07]| | | | | |
| | | 60-60,000[17.58 kW]| | | | | |
Available SKUs
Available Models| Description
RP1636AJ2NA| RP1636AJ2NA 16 SEER CUBE HP
RP1660AJ2NA| RP1660AJ2NA 16 SEER CUBE HP
RP1648AJ2NA| RP1648AJ2NA 16 SEER CUBE HP
RP1624AJ2NA| RP1624AJ2NA 16 SEER CUBE HP
RP1660AJ2NANOM| RP1660AJ2NANOM EXPORT R-410 MEXICO NOM
RP1636AJ2NANOM| RP1636AJ2NANOM EXPORT R-410 MEXICO NOM
RP1648AJ2NANOM| RP1648AJ2NANOM EXPORT R-410 MEXICO NOM
RP1624AJ2NANOM| RP1624AJ2NANOM EXPORT R-410 MEXICO NOM
General Data
- ¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
- ²HACR type circuit breaker of fuse.
- ³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.
General Data
General Data
Model No.| |
Nominal Tonnage| 5| 0
Liquid Line Odin Inches| 0| 0
Suction Line OdIn Inches| 0| 0
Refrigerant InOunces1| 242| 0
Compressor Type| |
Outdoor Coil|
Outdoor Coil Net Face Area Outer Coil| 28.3| 0
Outdoor Coil Net Face Area Inner Coil| 0| 0
Outdoor Coil Tube Diameter In Inches| 0.375| 0
Outdoor Coil Number Of Rows| 1| 0
Outdoor Coil Fins Per Inch| 20| 0
Outdoor Fan|
Outdoor Fan Diameter In Inches| 0| 0
Outdoor Fan Number Of Blades| 0| 0
Outdoor Fan Motor HP| 0| 0
Outdoor Fan CFM| 0| 0
Outdoor Fan Rpm| 0| 0
Outdoor Fan Watts| 0| 0
Shipping Weight In Pounds| 264| 0
Operating Weight In Pounds| 257| 0
Electrical Data
Model No.
Line Voltage Data (Volts-Phase-Hz)
MaximumOvercurrentProtectionAmps1
MinimumCircuitAmpacity1
Compressor
CompressorRatedLoadAmps1
CompressorLockedRotorAmps1
Condenser Fan Motor
CondenserFanMotorFullLoadAmps1
CondenserFanMotorLockedRotorAmps1
- ¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
- ²HACR type circuit breaker of fuse.
- ³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.
Accessories
RP1624A
Accessory Type| Part Number
RP1636A
Accessory Type| Part Number
RP1648A
Accessory Type| Part Number
RP1660A
Accessory Type| Part Number
Compressor crankcase heater| 44-17402-44
Compressor hard start kit| SK-A1
Compressor sound cover| 68-23427-26
High pressure control| Factory Standard
Low ambient control| RXAD-A08
Low pressure control| Factory Standard
Weighted Sound Power Level (dBA)
Model No. | RP1624AJ2NA | RP1636AJ2NA | RP1648AJ2NA | RP1660AJ2NA |
---|---|---|---|---|
Standard Rating | 71 | 76 | 74 | 75 |
TYPICAL OCTAVE BAND SPECTRUM (dBA
without tone adjustment)
| 125| 0| 0| 0| 0
250| 0| 0| 0| 0
500| 0| 0| 0| 0
1000| 0| 0| 0| 0
2000| 0| 0| 0| 0
4000| 0| 0| 0| 0
8000| 0| 0| 0| 0
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)
Unit Dimensions
Unit Dimensions
Model No.| RP1624AJ2NA| RP1624AJ2NANOM| RP1636AJ2NA| RP1636AJ2NANOM|
RP1648AJ2NA| RP1648AJ2NANOM| RP1660AJ2NA
OPERATING
H (Height)| INCHES| 31| 0| 35| 0| 45| 0| 45
L (Length)| INCHES| 33.75| 0| 33.75| 0| 35.75| 0| 35.75
W (Width)| INCHES| 33.75| 0| 33.75| 0| 35.75| 0| 35.75
SHIPPING
H (Height)| INCHES| 33.32| 0| 38.35| 0| 48.18| 0| 48.18
L (Length)| INCHES| 37.64| 0| 37.64| 0| 39.37| 0| 39.37
W (Width)| INCHES| 37.56| 0| 37.56| 0| 39.64| 0| 39.64
Unit Dimensions
Unit Dimensions
Model No.|
OPERATING
H (Height)| INCHES| 0
L (Length)| INCHES| 0
W (Width)| INCHES| 0
SHIPPING
H (Height)| INCHES| 0
L (Length)| INCHES| 0
W (Width)| INCHES| 0
No Unit Dimensions Image Found.
Control Wiring
No Control Wiring Image Found.
Application Guidelines
- Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc.
- Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F (12.8°C)
- Maximum outdoor operating air temperature is 125°F (51.7°C).
- For reliable operation, unit should be level in all horizontal planes.
- Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
- Do not apply capillary tube indoor coils to these units.
- Factory – supplied filter drier must be installed.
Refrigerant Line Size Information
13-16 SEER Single-Stage Air-Conditioners
Unit Size| Allowable Liquid Line Size| Allowable Suction Line Size|
- Apply Long Line Guidelines if Linear Line Length
- Exceeds Those Shown Below (Feet)
| Equivalent Length (Feet)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150|
151-175| 176-200| 201-225| 226-250
(- )A13| (-)A14 A/B| (-)A14 W| (- )A16| *Maximum
Vertical Rise (Outdoor Unit Below Indoor Unit) / Capacity Multiplier
1.5 Ton See Note 3| 1/4″| 5/8″| N/A| N/A| N/A| N/A| 25/1.0| 50/.99| 62/.98|
43/.98| 24/.97| 5/.97| NR| NR| NR| NR
5/16″| 5/8″| N/A| 223| 198| 188| 25/1.0| 50/.99| 75/.98| 98/.98| 93/.97|
88/.97| 83/.96| 78/.96| 73/.95| 68/.94
3/8″| 5-8″| 178| 148| 132| 125| 25/1.0| 50/.99| 75/.98| 100/.98| 100/.97|
100/.97| 100/.96| 100/.96| 100/.95| 100/.94
1/4″| 3/4″| N/A| N/A| N/A| N/A| 25/1.0| 50/.99| 62/.98| 43/.98| 24/.97|
5/.97| NR| NR| NR| NR
5/16″| 3/4″| N/A| 223| 198| 188| 25/1.0| 50/.99| 75/.98| 98/.98| 93/.97|
88/.97| 83/.99| 78/.98| 73/.98| 68/.98
3/8″| 3/4″| 178| 148| 132| 125| 25/1.0| 50/.99| 75/.98| 100/.98| 100/.97|
100/.97| 100/.99| 100/.98| 100/.98| 100/.98
2 Ton| 1/4″| 5/8″| N/A| N/A| N/A| N/A| 25/.99| 50/.98| 21/.97| NR| NR| NR| NR|
NR| NR| NR
5/16″| 5/8″| 243| 213| 193| 175| 25/.99| 50/.98| 75/.97| 87/.96| 77/.95|
69/.94| 61/.93| 53/.92| 45/.91| 37/.90
3/8″| 5/8″| 162| 142| 128| 117| 25/.99| 50/.98| 75/.97| 100/.96| 100/.95|
100/.94| 98/.93| 95/.92| 92/.91| 89/.90
1/4″| 3/8″| N/A| N/A| N/A| N/A| 25/1.00| 50/1.00| 21/.99| NR| NR| NR| NR| NR|
NR| NR
5/16″| 3/4″| 243| 213| 193| 175| 25/1.00| 50/1.00| 75/.99| 87/.99| 77/.98|
69/.98| 61/.98| 53/.97| 45/.97| 37/.96
3/8″| 3/4″| 162| 142| 128| 117| 25/1.00| 50/1.00| 75/.99| 100/.99| 100/.98|
100/.98| 98/.98| 95/.97| 93/.97| 37/.96
2.5 Ton| 5/16″| 5/8″| N/A| N/A| 133| 110| 25/.99| 50/.98| 75/.96| 70/.94|
59/.93| 48/.91| 36/.90| NR| NR| NR
3/8″| 5/8″| 142| 117| 88| 73| 25/.99| 50/.98| 75/.96| 100/.94| 98/.93| 94/.91|
90/.90| NR| NR| NR
5/16″| 3/4″| 213| 175| 133| 110| 25/1.00| 50/.99| 75/.99| 70/.98| 59/.98|
48/.97| 36/.96| 25/.96| 13/.95| NR
3/8″| 3/4″| 142| 117| 88| 73| 25/1.00| 50/.99| 75/.99| 100/.98| 98/.98|
94/.97| 90/.96| 86/.96| 82/.95| 78/.95
3 Ton| 5/16″| 5/8″| N/A| N/A| N/A| N/A| 25/.99| 50/.97| 66/.94| 49/.92|
32/.90| NR| NR| NR| NR| NR
3/8″| 5/8″| 108| 85| 90| 82| 25/.99| 50/.97| 75/.94| 95/.92| 89/.90| NR| NR|
NR| NR| NR
5/16″| 3/4″| N/A| 128| 135| 123| 25/1.0| 50/.99| 66/.98| 49/.98| 32/.97|
15/.96| NR| NR| NR| NR
3/8″| 3/4″| 108| 85| 90| 82| 25/1.00| 50/.99| 75/.99| 95/.98| 89/.97| 84/.96|
78/.95| 72/.92| 67/.93| 61/.93
1/2″| 3/4″| 54| 43| 45| 41| 25/1.00| 50/.99| 75/.98| 100/.98| 100/.97|
100/.96| 100/.95| 100/.92| 100/.93| 100/.93
5/16″| 7/8″| N/A| 128| 135| 123| 25/1.00| 50/1.00| 66/1.00| 49/.99| 32/.99|
15/.99| NR| NR| NR| NR
3/8″| 7/8″| 108| 85| 90| 82| 25/1.00| 50/1.00| 75/1.00| 95/.99| 89/.99|
84/.99| 78/.98| 72/.98| 67/.98| 61/.97
1/2″| 7/8″| 54| 43| 45| 41| 25/1.00| 50/1.00| 75/1.00| 100/.99| 100/.99|
100/.99| 100/.98| 100/.98| 100/.98| 100/.97
3.5 Ton| 3/8″| 3/4″| 150| 123| 102| 75| 25/.99| 50/.98| 75/.97| 88/.96|
80/.95| 72/.94| 65/.92| 57/.91| 49/.90| NR
1/2″| 3/4″| 75| 62| 51| 38| 25/.99| 50/.98| 75/.97| 100/.96| 100/.95| 100/.94|
100/.92| 100/.91| 100/.90| NR
3/8″| 7/8″| 150| 123| 102| 75| 25/1.00| 50/1.00| 75/.99| 88/.99| 80/.99|
72/.98| 65/.97| 57/.97| 49/.96| 42/.96
1/2″| 7/8″| 75| 62| 51| 38| 25/1.00| 50/1.00| 75/.99| 100/.99| 100/.99|
100/.98| 100/.97| 100/.97| 100/.96| 100/.96
Notes:**
- Do not exceed 200 ft linear line length.
- *Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit.
- **3/4″ suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
- Always use the smallest liquid line allowable to minimize refrigerant charge.
- Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
- Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
13-16 SEER Single-Stage Air-Conditioners
Unit Size| Allowable Liquid Line Size| Allowable
Suction Line Size| Apply Long Line Guidelines
if Linear Line Length Exceeds Those Shown Below (Feet)|
Equivalent Length (Feet)
< 25| 26-50| 51-75| 76-100| 101-125| 126-150|
151-175| 176-200| 201-225| 226-250
(- )A13| (-)A14 A/B| (-)A14 W| (- )A16| *Maximum
Vertical Rise (Outdoor Unit Below Indoor Unit) / Capacity Multiplier
4 Ton| 3/8″| 3/4″| 148| 110| N/A| 35| 25/.99| 50/.98| 70/.96| 77/.95| 67/.93|
57/.92| 46/.91| NR| NR| NR
1/2″| 3/4″| 74| 55| N/A| 18| 25/.99| 50/.98| 75/.96| 100/.95| 100/.93|
100/.92| 100/.91| NR| NR| NR
3/8″| 7/8″| 148| 110| N/A| 35| 25/1.00| 50/.99| 75/.99| 77/.98| 67/.97|
57/.97| 46/.96| 36/.96| 26/.95| 15/.95
1/2″| 7/8″| 74| 55| N/A| 18| 25/1.00| 50/.99| 75/.99| 100/.98| 100/.97|
100/.97| 100/.96| 100/.96| 99/.95| 97/.95
5 Ton| 3/8″| 3/4″| 78| 55| N/A| 0| 25/.99| 50/.97| 75/.94| 61/.92| 46/.90| NR|
NR| NR| NR| NR
1/2″| 3/4″| 39| 28| N/A| 0| 25/.99| 50/.97| 75/.94| 100/.92| 100/.90| NR| NR|
NR| NR| NR
3/8″| 7/8″| 78| 55| N/A| 0| 25/1.00| 50/.99| 75/.98| 61/.97| 46/.96| 32/.95|
18/.94| NR| NR| NR
1/2″| 7/8″| 93| 28| N/A| 0| 25/1.00| 50/.99| 75/.98| 100/.97| 100/.96|
100/.95| 18/.94| NR| NR| NR
3/8″| 1-1/8″| 78| 55| N/A| 0| 25/1.01| 50/1.01| 75/1.00| 61/1.00| 46/1.00|
32/.99| 18/.99| NR| NR| NR
1/2″| 1-1/8″| 39| 28| N/A| 0| 25/1.01| 50/1.01| 75/1.00| 100/1.00| 100/1.00|
100/.99| 97/.99| 95/.99| 92/.99| 89/.98
Notes:**
- Do not exceed 200 ft linear line length.
- *Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit
- **3/4″ suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
- Always use the smallest liquid line allowable to minimize refrigerant charge.
- Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
- Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
Refrigerant Line Size Information
13-16 SEER Single-Stage Air-Conditioners
Unit Size| Allowable Liquid
Line Size mm [in.]
| Allowable Suction Line Size mm [in.]| Apply Long Line Guidelines if Linear Line Length
Exceeds Those Shown Below (Feet)
| Equivalent Length (Feet)
< 8| 8-15| 16-23| 24-30| 31-38| 39-46|
47-53| 54-61| 62-69| 70-76
(- )A13| (-)A14 A/B| (-)A14 W| (- )A16| *Maximum
Vertical Rise (Outdoor Unit Below Indoor Unit) / Capacity Multiplier**
5.3 kW [1.5
ton] **See Note 3
| 6.35[1/4]| 9.53[5/8]| N/A| N/A| N/A| N/A| 8/1.0| 15/.99| 19/.98| 13/.98|
7/.97| 2/.97| NR| NR| NR| NR
7.94[5/16]| 15.88[5/8]| N/A| 68| 60| 57| 8/1.0| 15/.99| 23/.98| 30/.98|
28/.97| 27/.97| 25/.96| 24/.96| 22/.95| 21/.94
9.53[3/8]| 15.88[5/8]| 54| 45| 40| 38| 8/1.0| 15/.99| 23/.98| 30/.98| 30/.97|
30/.97| 30/.96| 30/.96| 30/.95| 30/.94
6.35[1/4]| 19.05[3/4]| N/A| N/A| N/A| N/A| 8/1.0| 15/.99| 19/.98| 13/.98|
7/.97| 2/.97| NR| NR| NR| NR
7.94[5/16]| 19.05[3/4]| N/A| 68| 60| 57| 8/1.0| 15/.99| 23/.98| 30/.98|
28/.97| 27/.97| 25/.99| 24/.98| 22/.98| 21/.98
9.53[3/8]| 19.05[3/4]**| 54| 45| 40| 38| 8/1.0| 15/.99| 23/.98| 30/.98|
30/.97| 30/.97| 30/.99| 30/.98| 30/.98| 30/.98
7.0 kW [2 Ton]| 6.35[1/4]| 15.88[5/8]| N/A| N/A| N/A| N/A| 8/.99| 15/.98|
6/.97| NR| NR| NR| NR| NR| NR| NR
7.94[5/16]| 15.88[5/8]| 74| 65| 59| 53| 8/.99| 15/.98| 23/.97| 27/.96| 23/.95|
21/.94| 19/.93| 16/.92| 14/.91| 11/.90
9.53[3/8]| 15.88[[5/8]| 49| 43| 39| 36| 8/.99| 15/.98| 23/.97| 30/.96| 30/.95|
30/.94| 30/.93| 29/.92| 28/.91| 27/.90
6.35[1/4]| 19.05[3/8]| N/A| N/A| N/A| N/A| 8/1.00| 15/1.00| 6/.99| NR| NR| NR|
NR| NR| NR| NR
7.94[5/16]| 19.05[3/4]| 74| 65| 59| 53| 8/1.00| 15/1.00| 23/.99| 27/.99|
23/.98| 21/.98| 19/.98| 16/.97| 14/.97| 11/.96
9.53[3/8]| 19.05[3/4]| 49| 43| 39| 36| 8/1.00| 151/1.00| 23/.99| 30/.99|
30/.98| 30/.98| 30/.98| 29/.97| 18/.97| 27/.96
8.6 kW [2.5
Ton]
| 7.94[5/16]| 15.88[5/8]| N/A| N/A| 40| 34| 8/.99| 15/.98| 23/.96| 21/.94|
18/.93| 15/.91| 11/.90| NR| NR| NR
9.53[3/8]| 15.88[5/8]| 43| 36| 27| 22| 8/.99| 15/.98| 23/.96| 30/.94| 30/.93|
29/.91| 27/.90| NR| NR| NR
7.94[5/16]| 19.05[3/4]| 65| 53| 40| 334| 8/1.00| 15/.99| 23/.99| 21/.98|
18/.98| 15/.97| 11/.96| 8/.96| 4/.95| NR
9.53[3/8]| 19.05[3/4]| 43| 36| 27| 22| 8/1.00| 15/.99| 23/.99| 30/.98| 30/.98|
29/.97| 27/.96| 26/.96| 25/.95| 24/.95
10.6 kW [3 Ton]| 7.94[5/16]| 15.88[5/8]| N/A| N/A| N/A| N/A| 8/.99| 15/.97|
20/.94| 15/.92| 10/.90| NR| NR| NR| NR| NR
9.53[3/8]| 15.88[5/8]| 33| 26| 27| 25| 8/.99| 15/.97| 23/.94| 29/.92| 27/.90|
NR| NR| NR| NR| NR
7.94[5/16]| 19.05[3/4]| N/A| 39| 41| 37| 8/1.0| 15/.99| 20/.98| 15/.98|
10/.97| 5/.96| NR| NR| NR| NR
9.53[3/8]| 19.05[3/4]| 33| 26| 27| 25| 8/1.00| 15/.99| 23/.99| 29/.98| 27/.97|
26/.96| 24/.95| 22/.92| 20/.93| 19/.93
12.70[1/2]| 19.05[3/4]| 17| 13| 14| 12| 8/1.00| 15/.99| 23/.98| 30/.98|
30/.97| 30/.96| 30/.95| 100/.92| 30/.93| 30/.93
7.94[5/16]| 22.23[7/8]| N/A| 39| 41| 37| 8/1.00| 15/1.00| 20/1.00| 15/.99|
10/.99| 5/.99| NR| NR| NR| NR
9.53[3/8]| 22.23[7/8]| 33| 26| 27| 25| 8/1.00| 15/1.00| 23/1.00| 29/.99|
27/.99| 26/.99| 24/.98| 22/.98| 20/.98| 19/.97
12.70[1/2]| 22.23[7/8]| 17| 13| 14| 12| 8/1.00| 15/1.00| 23/1.00| 30/.99|
30/.99| 30/.99| 30/.98| 30/.98| 30/.98| 30/.97
12.3 kW [3.5 Ton]| 9.53[3/8]| 19.05[3/4]| 46| 36| 31| 23| 8/.99| 15/.98|
23/.97| 27/.96| 24/.95| 22/.94| 20/.92| 17/.91| 15/.90| NR
12.70[1/2]| 19.05[3/4]| 23| 19| 15| 11| 8/.99| 15/.98| 23/.97| 30/.96| 30/.95|
30/.94| 30/.92| 30/.91| 30/.90| NR
9.53[3/8]| 22.23[7/8]| 46| 38| 31| 23| 8/1.00| 15/1.00| 23/.99| 27/.99|
24/.99| 22/.98| 20/.97| 17/.97| 15/.96| 13/.96
12.70[1/2]| 22.23[7/8]| 23| 19| 15| 11| 8/1.00| 15/1.00| 23/.99| 30/.99|
30/.99| 30/.98| 30/.97| 30/.97| 30/.96| 30/.96
Notes:
- Do not exceed 200 ft linear line length.
- *Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit.
- **3/4″ suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return
- Always use the smallest liquid line allowable to minimize refrigerant charge.
- Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed
- Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
13-16 SEER Single-Stage Air-Conditioners
Unit Size| Allowable Liquid Line Size| Allowable Suction Line Size| Apply Long Line Guidelines if Linear Line Length
Exceeds Those Shown Below (Feet)
| Equivalent Length (Feet)
< 8| 8-15| 16-23| 24-30| 31-38| 39-46|
47-53| 54-61| 62-69| 70-76
(- )A13| (-)A14 A/B| (-)A14 W| (- )A16| *Maximum
Vertical Rise (Outdoor Unit Below Indoor Unit) / Capacity Multiplier
4 Ton| 9.53[3/8]| 19.05[[3/4]| 45| 34| N/A| 11| 8/.99| 15/.98| 23/.96| 24/.95|
20/.93| 17/.92| 14/.91| NR| NR| NR
12.7[1/2]| 19.05[3/4]| 23| 17| N/A| 5| 8/.99| 15/.98| 23/.96| 30/.95| 30/.93|
30/.92| 30/.91| NR| NR| NR
9.53[3/8]| 22.23[7/8]| 45| 34| N/A| 11| 8/1.00| 15/.99| 23/.99| 24/.98|
20/.97| 17/.97| 14/.96| 11/.96| 8/.95| 5/.95
12.7[1/2]| 22.23[7/8]| 23| 17| N/A| 5| 8/1.00| 15/.99| 23/.99| 30/.98| 30/.97|
30/.97| 30/.96| 30/.96| 30/.95| 30/.95
5 Ton| 9.53[3/8]| 19.05[3/4]| 24| 17| N/A| 0| 8/.99| 15/.97| 23/.94| 19/.92|
14/.90| NR| NR| NR| NR| NR
12.7[1/2]| 19.05[3/4]| 12| 8| N/A| 0| 8/.99| 15/.97| 23/.94| 30/.92| 30/.90|
NR| NR| NR| NR| NR
9.53[3/8]| 22.23[7/8]| 24| 17| N/A| 0| 8/1.00| 15/.99| 23/.98| 19/.97| 14/.96|
10/.95| 5/.94| NR| NR| NR
12.7[1/2]| 22.23[7/8]| 12| 8| N/A| 0| 8/1.00| 15/.99| 23/.98| 30/.97| 30/.96|
30/.95| 30/.94| 29/.94| 28/.93| 2/.92
9.53[3/8]| 28.58[1-1/8]| 24| 17| N/A| 0| 8/1.01| 15/1.01| 23/1.00| 19/1.00|
14/1.00| 10/.99| 5/.99| NR| NR| NR
12.7[1/2]| 28.58[1-1/8]| 12| 8| N/A| 0| 8/1.01| 15/1.01| 23/1.00| 30/1.00|
30/1.00| 30/.99| 30/.99| 29/.99| 28/.99| 27/.98
Notes:**
- Do not exceed 200 ft linear line length.
- *Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit.
- **3/4″ suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return.
- Always use the smallest liquid line allowable to minimize refrigerant charge.
- Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
- Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
Performance Data @ AHRI Standard Conditions – Cooling
Designated Test Combinations (DTC)
Outdoor Unit| Indoor Coil| Total Capacity BTU/H
[kW]| Net Sensible BTU/H [kW]| Net Latent BTU/H [kW]|
SEER| EER| Inddor CFM [L/s]
RP1624AJ2NA| TZHDLVMT2421| 24000 [7]| 19200 [5.6]| 4800 [1.4]| 16| 13| 825
[null]
RP1624AJ2NANOM| TZHDLVMT2421| 24000 [7]| 19200 [5.6]| 4800 [1.4]| 16| 13| 825
[null]
RP1636AJ2NA| TZHDLVMT3621| 34200 [9.9]| 27360 [7.9]| 6840 [2]| 16| 13| 1225
[null]
RP1636AJ2NANOM| TZHDLVMT3621| 34200 [9.9]| 27360 [7.9]| 6840 [2]| 16| 13| 1225
[null]
RP1648AJ2NA| TZHDLVMT4821| 45500 [13.2]| 36400 [10.6]| 9100 [2.6]| 16| 12.5|
1650 [null]
RP1648AJ2NANOM| TZHDLVMT4821| 45500 [13.2]| 36400 [10.6]| 9100 [2.6]| 16|
12.5| 1650 [null]
RP1660AJ2NA| TZHDLVST6024| 57000 [16.5]| 45600 [13.2]| 11400 [3.3]| 16| 12.5|
1725 [null]
RP1660AJ2NANOM| TZHDLVST6024| 57000 [16.5]| 45600 [13.2]| 11400 [3.3]| 16|
12.5| 1725 [null]
Note: Additional ratings and system match ups can be accessed on MyRheem.com at: https://my.rheem.com/static/private/ahriresidential.html Additional ratings and system match ups and downloadable ratings certificates can be accessed from the AHRI website: www.ahridirectory.org
[ ] Designates Metric Conversions
GENERAL TERMS OF LIMITED WARRANTY*
- Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
- For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
- Conditional Parts (Registration Required)
- Ten (10) Years
Documents / Resources
|
Rheem RP1624AJ2NA Split System Air Conditioners And Heat
Pumps
[pdf] User Manual
RP1624AJ2NA Split System Air Conditioners And Heat Pumps, RP1624AJ2NA, Split
System Air Conditioners And Heat Pumps, Conditioners And Heat Pumps, Heat
Pumps, Pumps
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>