DORNBRACHT 782-FF Series Luxurious Bathroom Iconic Designs Instruction Manual
- June 15, 2024
- DORNBRACHT
Table of Contents
Dornbracht assembly Instructions
Installation instructions
Valid from Juli, 1st 2016
US/CA Article No.
XX XXX XXX-FF 0010
Max. flow 1.2 gpm
Danger of scalding
Pressure fluctuations in the water supply lead to sudden and considerable water
temperature fluctuations.
Avoid pressure fluctuations and limit hot water temperature.
Any scalds should be examined by a physician and treated, if necessary.
13 715 782-FF / 13 715 782-FF 0010 / 13 716 782-FF / 13 716 782-FF 0010 /
20 713 782-FF / 20 713 782-FF 0010 / 20 715 782-FF / 20 715 782-FF 0010 /
20 728 782-FF / 20 728 782-FF 0010 / 20 733 782-FF / 20 733 782-FF 0010 /
20 735 782-FF / 20 735 782-FF 0010 / 24 610 785-FF
General warnings
Caution! This symbol gives warning of damage to property if safety
instructions are not followed.
Note! This symbol gives warning of possible damage to property if
installation instructions are not followed.
All the work must be carried out exclusively by competent, suitably qualified
personnel! Only then can there be any assumption of liability on the part of
the manufacturer. Priority is always given to national statutory accident
prevention regulations. Operating conditions and dimensions can be found in
the appendix.
All work must be carried out exclusively by trained, qualified personnel! Only
then can the manufacturer assume liability. National accident prevention
regulations have priority in all cases.
Operating conditions and dimensions can be found in the appendix.
Technical data.
Care and maintenance
Parts supplied.
i 24 610 785-FF
Operating conditions
Recommended flow temperature Maximum flow temperature | ≤ 65 °C |
---|---|
Maximum flow temperature momentary | ≤ 90 °C |
Minimum flow pressure | 1 bar |
Maximum flow pressure | 5 bar |
Recommended operating pressure | 3 bar |
Test pressure | 16 bar |
Noise class I according to DIN 4109 .
For noise levels to comply with national standards, a pressure reducer must be
fitted in the supply pipe if the standing pressure exceeds 5 bar.
Recommended flow temperaturMaximum short-term flow | ≤ 149 °F |
---|---|
Maximum short-term flow temperature | ≤ 194 °F |
Minimum flow pressure | 15 psi |
Maximum flow pressure | 73 psi |
Recommended operating pressure | 44 psi |
Test pressure | 232 psi |