Morris FAIN-26170 Series Fresh Air User Manual
- June 9, 2024
- MORRIS
Table of Contents
FRESH AIR SERIES
• FAIN-26170 / FAOD-26171
• FAIN-35170 / FAOD-35171
Split type Inverter Air Conditioner
USER MANUAL
Please read this manual carefully before use this product
- The design and specifications are subject to change without prior notice for product improvement.
Consult with the sales agency or manufacturer for details. - The shape and position of buttons and indicators may vary according to the model, but their function are the same.
Accessories
Indoor Unit
Outdoor Unit
SAFETY PRECAUTIONS
SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER
-
Read this guide before installing and using the appliance.
-
During the installation of the indoor and outdoor units, access to the working area should be forbidden to children. Unforeseeable accidents could happen.
-
Make sure that the base of the outdoor unit is firmly fixed.
-
Check that air cannot enter the refrigerant system and check for refrigerant leaks when moving the air conditioner.
-
Carry out a test cycle after installing the air conditioner and record the operating data.
-
Protect the indoor unit with a fuse of suitable capacity for the maximum input current or with another overload protection device.
-
Ensure that the mains voltage corresponds to that stamped on the rating plate. Keep the switch or power plug clean. Insert the power plug correctly and firmly into the socket, thereby avoiding the risk of electric shock or fire due to insufficient contact.
-
Check that the socket is suitable for the plug , otherwise have the socket changed.
-
The appliance must be fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under over voltage category III conditions, and these means must be incorporated in the fixed wiring in accordance with the wiring rules.
-
The air conditioner must be installed by professional or qualified persons.
-
Do not install the appliance at a distance of less than 50 cm from inflammable substances (alcohol, etc.) Or from pressurized containers (e.g. spray cans).
-
If the appliance is used in areas without the possibility of ventilation, precautions must be taken to prevent any leaks of refrigerant gas from remaining in the environment and creating a danger of fire.
-
The packaging materials are recyclable and should be disposed of in the separate waste bins.
Take the air conditioner at the end of its useful life to a special waste collection center for disposal. -
Only use the air conditioner as instructed in this booklet. These instructions are not intended to cover every possible condition and situation. As with any electrical household appliance, common sense and caution are therefore always recommended for installation, operation and maintenance.
-
The appliance must be installed in accordance with applicable national regulations.
-
Before accessing the terminals, all the power circuits must be disconnected from the power supply.
-
The appliance shall be installed in accordance with national wiring regulations.
-
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
-
Do not try to install the conditioner alone, always contact specialized technical personnel.
-
Cleaning and maintenance must be carried out by specialized technical personnel. In any case disconnect the appliance from the mains electricity supply before carrying out any cleaning or maintenance.
-
Ensure that the mains voltage corresponds to that stamped on the rating plate. Keep the switch or power plug clean. Insert the power plug correctly and firmly into the socket, thereby avoiding the risk of electric shock or fire due to insufficient contact.
-
Do not pull out the plug to switch off the appliance when it is in operation, since this could create a spark and cause a fire, etc.
-
This appliance has been made for air conditioning domestic environments and must not be used for any other purpose, such as for drying clothes, cooling food, etc.
-
Always use the appliance with the air filter mounted. The use of the conditioner without air filter could cause an excessive accumulation of dust or waste on the inner parts of the device with possible subsequent failures.
-
The user is responsible for having the appliance installed by a qualified technician, who must check that it is earth in accordance with current legislation and insert a thermos magnetic circuit breaker.
-
The batteries in the remote controller must be recycled or disposed of properly. For disposal of scrap batteries, please discard the batteries as sorted municipal waste at the accessible collection point.
-
Never remain directly exposed to the flow of cold air for a long time. The direct and prolonged exposition to cold air could be dangerous for your health. Particular care should be taken in the rooms where there are children, old or sick people.
-
If the appliance gives off smoke or there is a smell of burning, immediately cut off the power supply and contact the Service Center.
-
The prolonged use of the device in such conditions could cause fire or electrocution.
-
Have repairs carried out only by an authorised Service Centra of the manufacturer. Incorrect repair could expose the user to the risk of electric shock, etc.
-
Unhook the automatic switch if you foresee not to use the device for a long time. The airflow direction must be properly adjusted.
-
The flaps must be directed downwards in the heating mode and upwards in the cooling mode.
-
Ensure that the appliance is disconnected from the power supply when it will remain inoperative for a long period and before carrying out any cleaning or maintenance.
-
Selecting the most suitable temperature can prevent damage to the appliance.
SAFETY RULES AND PROHIBITIONS
- Do not bend, tug or compress the power cord since this could damage it. Electrical shocks or fire are probably due to a damaged power cord. Specialized technical personnel only must replace a damaged power cord.
- Do not use extensions or gang modules.
- Do not touch the appliance when barefoot or parts of the body are wet or damp.
- Do not obstruct the air inlet or outlet of the indoor or the outdoor unit. The obstruction of these openings causes a reduction in the operative efficiency of the conditioner with possible consequent failures or damages.
- In no way alter the characteristics of the appliance.
- Do not install the appliance in environments where the air could contain gas, oil or sulphur or near sources of heat.
- This appliance is not intended for use by persons (including children ) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Do not climb onto or place any heavy or hot objects on top of the appliance.
- Do not leave windows or doors open for long when the air conditioner is operating.
- Do not direct the airflow onto plants or animals.
- A long direct exposition to the flow of cold air of the conditioner could have negative effects on plants and animals.
- Do not put the conditioner in contact with water. The electrical insulation could be damaged and thus causing electrocution.
- Do not climb onto or place any objects on the outdoor unit.
- Never insert a stick or similar object into the appliance. It could cause injury.
- Children should be supervised to ensure that they do not play with the appliance. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
NAME OF PARTS
Note: This figure shown may be different from the actual object. Please take the latter as the standard.
Indoor Display
No. | LED | Function |
---|---|---|
1 | Indicator for Timer, temperature and Error codes. | |
2 | Lights up when Fresh Air function is on. | |
3 | Lights up when Wi-Fi is on. | |
4 | Operation indicator/Air quality status indicator (if TVOC function is |
available).
Note:
The air conditioner automatically adjusts the display brightness and buzzer
sound according to the ambient light intensity. When the air conditioner
detects that the ambient light is weak for a period of time, it will
automatically turns off the display temporarily. If there is a remote control
or APP operation, the display will display at a low brightness for a short
time, and the buzzer will respond at a lower volume; When the air conditioner
detects that the ambient light is strong for a period of time, exit the above
operation.
The shape and position of switches and indicators may be different according
to the model, but their function is the same.
REMOTE CONTROL
Remote control DISPLAY
No. | Symbols | Meaning |
---|---|---|
1 | Battery indicator | |
2 | Auto Mode | |
3 | Cooling Mode | |
4 | Dry Mode | |
5 | Fan only Mode | |
6 | Heating Mode | |
7 | ECO Mode | |
8 | Timer | |
9 | Temperature indicator | |
10 | Fan speed: |
Auto/ low/ low-mid/ mid/ mid-high/ high
11| | Mute function
12| | TURBO function
13| | Up-down auto swing
14| | Left-right auto swing
15| | SLEEP function
16| | Health function
17| | I FEEL function
18| | 8°C heating function
19| | Signal indicator
20| | Gentle wind
21| | Child-Lock
22| | Display ON/OFF
23| | GEN function
24| | Self-Clean function
25| | Anti-Mildew
26| | Fresh air
The display and some functions of the remote control may vary according to the model.
No. | Button | Function |
---|---|---|
1 | To turn on/off the air conditioner . | |
2 | To increase temperature, or Timer setting hours. | |
3 | To decrease temperature, or Timer setting hours. | |
4 | MODE | To select the mode of operation (AUTO, COOL DRY, FAN, HEAT). |
5 | ECO | To activate/deactivate the ECO function. |
Long press to activate/deactivate the 8°C heating function (depending on
models).
6| TURBO| To activate/deactivate the TURBO function.
7| FAN| To select the fan speed of auto/mute/low/low-mid/mid/mid-
high/high/turbo.
8| TIMER| To set the time for timer on/off.
9| SLEEP| To switch-on/off the function SLEEP.
10| DISPLAY| To switch-on/off the LED display.
11| | To stop or start horizontal louver movement or set the desired up/down
air flow direction.
12| | To stop or start horizontal louver movement or set the desired
left/rightair flow direction.
13| I FEEL| To switch-on/off the I FEEL function.
14| MUTE| To switch-on/off the MUTE function.
Long press to activate/deactivate the GEN function (depending on models).
is| MODE + TIMER| To activate/deactivate the CHILD-LOCK function.
16| GENTLE WIND| To activate/deactivate the GENTLE WIND function (depending on
models).
17| HEALTH| To activate/deactivate the HEALTH function (depending on models).
To activate/deactivate the SELF-CLEAN function when switch OFF.
The display and some functions of the remote control may vary according to the
model.
The shape and position of buttons and indicators may vary according to the
model, but their function is the same. The unit confirms the correct reception
of each button with the beep.
Replacement of Batteries
Remove the battery cover plate from the rear of the remote control, by sliding
it in direction as the arrow.
Install the batteries according the direction (+ and -)shown on the Remote
Control.
Reinstall the battery cover by sliding it into place.
Use 2 pieces LRO3 AAA (1.5V) batteries.Do not use rechargeable batteries.
Replace the old batteries with new ones of the same type when the display is
no longer legible.
Do not dispose batteries as unsorted municipal waste.
Collection of such waste separately for special treatment is necessary.
For some models of the remote controller, you can program the temperature
display between °C and °F.
- Press and hold the TURBO button over 5 seconds to get into the change mode;
- Press and hold the TURBO button, until it switch to C and F;
- Then release the pressing and wait for 5 seconds, the function will be selected.
Note:
- Direct the remote control toward the Air conditioner.
- Check that there are no objects between the remote control and the Signal receptor in the indoor unit.
- Never leave the remote control exposed to the rays of the sun.
- Keep the remote control at a distance of at least 1m from the television or other electrical appliances.
COOLING MODE
COOL The cooling function allows the air conditioner to cool the room and
reduce Air humidity at the same time.
COOL
To activate the cooling function (COOL), press the MODE button until the
symbol appears on the display.
With the button or set a temperature lower than that of the room.
FAN MODE (Not FAN button)
FAN
Fan mode, air ventilation only.
To set the FAN mode, press MODE until appears on the display.
DRY MODE
DRY This function reduces the humidity of the air to make the room more
comfortable.
To set the DRY mode, Press MODE until appears in the display. An automatic
function of pre-setting is activated.
AUTO MODE
AUTO Automatic mode.
To set the AUTO mode, press MODE until appears on the display.
In AUTO mode the run mode will be set automatically according to the room
temperature.
HEATING MODE
HEAT The heating function allows the air conditioner to heat the room.
To activate the heating function (HEAT), press the MODE button until the
symbol appears on the display.
With the button or set a temperature higher than that of the room.
In HEATING operation, the appliance can automatically activate a defrost
cycle, which is essential to clean the frost on the condenser so as to recover
its heat exchange function. This procedure usually lasts for 2-10 minutes.
During defrosting, indoor unit fan stop operation. After defrosting, it
resumes to HEATING mode automatically.
(For North American market) If necessary, you can press ECO button 10
times within 8 seconds under heating mode to start the forced defrosting. It
will defrost the outdoor ice much faster.
FAN SPEED function (FAN button)
FAN Change the operating fan speed.
Press FAN button to set the running fan speed, it can be set to AUTO/
MUTE/ LOW/ LOW-MID / MID/ MID-HIGH/ HIGH/ TURBO speed circularly.
Child-Lock function
- Long press MODE and TIMER button together to active this function, and do it again to deactivate this function.
- Under this function, no single button will active.
TIMER function —- TIMER ON
TIMER To automatic switch on the appliance.
When the unit is switch-off, you can set the TIMER ON.
To set the time of automatic switch-on as below:
- Press TIMER button first time to set the switch-on, and will appear on the remote display and flashes.
- Press or to button to set desired Timer-on time. Each time you press the button, the time increases/decreases by half an hour between 0 and 10 hours and by one between 10 and 24 hours.
- Press TIMER button second time to confirm.
- After Timer-on setting, set the needed mode (Cool/ Heat/ Auto/ Fan/ Dry), by press the MODE button. And set the needed fan speed, by press FAN button. And press or to set the needed operation temperature. CANCEL it by press TIMER button.
TIMER function —- TIMER OFF
To automatic switch off the appliance.
TIMER OFF.
TIMER To set the time of automatic switch-off, as below:
When the unit is switch-on, you can set the
- Confirm the appliance is ON.
- Press the TIMER button at first time to set the switch-off. Press or to set the needed timer.
- Press TIMER button at the second time to confirm.
CANCEL it by press TIMER button.
Note: All programming should be operated within 5 seconds, otherwise the setting will be cancelled.
SWING function
-
Press the button SWING to activate the louver,
1.1 Press to activate the horizontal flaps to swing from up to down, the will appear on the remote display.
1.2 Press to active the vertical deflectors to swing from left to right, the will appear on the remote display.
1.3 Do it again to stop the swing movement at the current angle. -
If the vertical deflectors are positioned manually which placed under the flaps, they allow to move the air flow direct to rightward or leftward.
-
Long press or over 3 seconds to select more angles of the airflow direction.
Never position Flaps manually, the delicate mechanism might seriously damaged!
Never put fingers, sticks or other objects into the air inlet or outlet vents.
Such accidental contact with live parts might cause unforeseeable damage or
injury.
TURBO function
TURBO
To activate turbo function, press the TURBO button, and will appear on
the display. Press again to cancel this function. In COOL/ HEAT mode, when you
select TURBO feature, the appliance ****will turn to quick COOL or quick HEAT
mode, and operate the highest fan speed to blow strong airflow.
MUTE function
MUTE
-
Press MUTE button to active this function, and will appears on the remote display.
Do it again to deactivate this function. -
When the MUTE function runs, the remote controller will display the auto fan speed, and the indoor unit will operate at lowest fan speed to be quiet feeling.
-
When press FAN/ TURBO/ SLEEP button, the MUTE function will be cancel. MUTE function can not be activated under dry mode.
SLEEP function
SLEEP
Pre-setting automatic operating program.
Press SLEEP button to activate the SLEEP function, and appears on the display.
Press again to cancel this function.
After 10 hours running in sleep mode, the air conditioner will change to the
previous setting mode.
I FEEL function (Optional)
I FEEL
Press I FEEL button to active the function, the **will appear on the remote
display.
Do it again to deactivate this function.
This function enables the remote control to measure the temperature at its
current location, and send this signal to the air conditioner to optimize the
temperature around you and ensure the comfort.
ECO function
ECO
In this mode the appliance automatically sets the operation to save energy.
Press the ECO button, the appears on the display, and the appliance will run
in ECO mode.
Press again to cancel it.
Note:** The ECO function is available in both COOLING and HEATING modes.
DISPLAY function (Indoor display)
DISPLAY
Switch ON/OFF the LED display on panel.
Press DISPLAY button to switch off the LED display on the panel. Press
again to switch on the LED display.
GEN function (Optional)
- Turn on the indoor unit at first, and long press MUTE button 3 seconds to active, and do it again to deactivate this function.
- Under this function, short press MUTE button to select the General type L3 – L2 – L1 – OF.
- Select OF and wait 2 seconds to exit it.
Reset Wi-Fi
- Method 1: Press button DISPLAY 6 times in 8 seconds.
- Method 2: Press button ECO 6 times in 8 seconds.
- Method 3: Long press MODE and over 3 seconds.
You will hear 2 beeps and CF or AP will show on the indoor display after the operation.
SELF-CLEAN function
(Optional)
To active this function, turn off the indoor unit at first, then press HEALTH
button then you will hear a beep, AC will appear on the indoor LED, and
will appear on the remote display .
- This function helps carry away the accumulated dirt, bacteria, etc from the indoor evaporator.
- This function will run about 30 minutes, and it will return to the pre-setting mode. You can press button to cancel this function during the process.
You will hear 2 beeps when it’s finished or cancelled.
It’s normal if there is some noise during this function process, as plastic
materials expand with heat and contract with cold.
We suggest operating this function at the following ambient conditions to
avoid certain safety protection features.
Indoor unit | Temp < 86° F (30° C) |
---|---|
Outdoor unit | 41° F (5 C) < Temp < 86° F (30 °C) |
It’s suggested to utilize this function every 3 months.
8 °C heating function (Optional)
-
Long press ECO button over 3 seconds to active this function, and o ( 8°C 46°F ) will appear on the remote display.
Do it again to deactivate this function. -
This function will auto start the heating mode when the room temperature is lower than 8°C (46 °F), and it will return to standby if the temperature reaches 9°C (48°F).
-
If the room temperature is higher than 18 °C (64 °F), the appliance will cancel this function automatically.
Gentle Wind function (Optional)
Gentle Wind function (Optional)
-
Turn on the indoor unit, and change to COOL mode, then press GENTLE WIND button or to active this function, will appear on the display.
Do it again to deactivate it. -
This function will auto close the vertical flaps, and give you the comfortable gentle wind feeling.
Health function (Optional)
-
Turn on the indoor unit at first, press HEALTH to active this function, will appear on the display.
Do it again to deactivate it. -
When the HEALTH function is initiated, the UVC Lights(depending on models) will be energized and running.
Fresh Air function
FRESH AIR This function will pump the fresh air from outside to inside
FRESH AIR Continue press button until select your desired Fresh Air fan speed
or deactivate this function as circulation Low-Mid-High-OFF, then loose
button. The following indicator will appear on the display:
Note:
- This function is available when in OFF/Heating Cooling/Fan/Auto mode.
- In OFF mode, the system may run automatically because of the big difference of temperature between indoor and outside.
- If the indoor display shows the Fresh Air indicator and shows CL. You can replace the filter and long press button over 5 seconds to clear the indicator CL. FRESH AIR
TVOC function (Optional)
This function enable to detect some kinds of harmful gases in the room and
display the air quality status.
If the unit is equipped with this function, when the unit is operation, it
will display the following indicator states according to the detected
concentration of different harmful gases.
- The more orange color in the circle, the worse the air quality is (Note:the air quality detection object is TVOC, such as polycyclic aromatic hydrocar-bons, benzene, formaldehyde, trichl oroethylene, etc.).
- All panel display lights including TVOC can be turned off by pressing the DISPLAY button.
- Turning on the Fresh Air function can improve the indoor air quality, but when the outdoor air pollution is serious, it is recommended to turn off the Fresh Air function.
- If the unit is not equipped with TVOC function, it will display 100% blue when the machine is running and the color will not change.
The detection of TVOC is mainly aimed at various volatile organic compounds, such as formaldehyde, benzene, polycyclic aromatic hydrocarbons, etc., close to perfume, toilet water, alcohol, air freshen ers, etc., will also lead to an increase in the detected TVOC concentration.
The TVOC sensor needs to be initialized every time it is powered on, please wait patiently for about 10 minutes.
Depending on the brand or working principle of the testing equipment, TVOC testing results may vary.
OPERATION INSTRUCTIONS
Attempt to use the air conditioner under the temperature beyond the specified range may cause the air conditioner protection device to start and the air conditioner may fail to operate. Therefore, try to use the air conditioner in the following temperature conditions.
MODE Temperature | Heating | Cooling | Dry |
---|---|---|---|
Room temperature | 0°C-27t(32°F-80°F) | 17t-32°C 63°F-90°F) | |
-20°C-24°C | 15°C-50°C(59°F-122 °F) | ||
Outdoor temperature | (-4 °F-75 °F) | (Low temperature cooling: -15°C-50° C(5 |
°F-122° F))
With the power supply connected, restart the air conditioner after shutdown,
or switch it to other mode during operation, and the air conditioner
protection device will start. The compressor will resume operation after 3
minutes.
Characteristics of heating operation (applicable to Heating pump)
Preheating:
When the heating function is enabled, the indoor unit will take 2~5 minutes
for preheating, after that the air conditioner will start heating and blows
warm air.
Defrosting:
During heating, when the outdoor unit frosted, the air conditioner will enable
the automatic defrosting function to improve the heating effect. During
defrosting, the indoor and outdoor fans stop running. The air conditioner will
resume heating automatically after defrosting finish.
INSTRUCTIONS FOR SERVICING(R32)
- Check the information in this manual to find out the dimensions of space needed for proper installation of the device, including the minimum distances allowed compared to adjacent structures.
- Appliance shall be installed, operated and stored in a room with a floor area larger than 4m .
- The installation of pipe-work shall be kept to a minimum.
- The pipe-work shall be protected from physical damage, and shall not be installed in an unventilated space if the space is smaller than 4m .
- The compliance with national gas regulations shall be observed.
- The mechanical connections shall be accessible for maintenance purposes.
- Follow the instructions given in this manual for handling, installing, cleaning, maintaining and disposing of the refrigerant.
- Make sure ventilation openings clear of obstruction.
- Notice: The servicing shall be performed only as recommended by the manufacturer.
- Warning: The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
- Warning: The appliance shall be stored in a room without continuously operating open flames (for example an operating gas appliance) and ignition sources (for example an operating electric heater).
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- It is appropriate that anyone who is called upon to work on a refrigerant circuit should hold a valid and up-to-date certificate from an assessment authority accredited by the industry and recognizing their competence to handle refrigerants, in accordance with the assessment specification recognized in the industrial sector concerned. Service operations should only be carried out in accordance with the recommendations of the equipment manufacturer. Maintenance and repair operations that require the assistance of other qualified persons must be conducted under the supervision of the person competent for the use of flammable refrigerants.
- Every working procedure that affects safety means shall only be carried out by competent persons.
- Warning:
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
- Do not pierce or burn.
- Be aware that refrigerants may not contain an odor. 16. Information on servicing:
- Checks to the area Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
- Work procedure Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapor being present while the work is being performed.
- General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material
- Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe. - Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO 2 fire extinguisher adjacent to the charging area. - No ignition sources No person carrying out work in relation to a refrigeration system which involves exposing any pipe work shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area aroundthe equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. No Smoking signs shall be displayed.
- Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out.
The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere. - Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed.
If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants:
— The charge size is in accordance with the room size within which the refrigerant containing parts are installed;
— The ventilation machinery and outlets are operating adequately and are not obstructed;
— If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
— Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
— Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded. - Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
Initial safety checks shall include:
— That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
— That there no live electrical components and wiring are exposed while charging, recovering or purging the system;
— That there is continuity of earth bonding.
- Repairs to sealed components
- During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
- Particular attention shall be paid to the following to ensure that by
working on electrical components, the casing is not altered in such a way that
the level of protection is affected. This shall include damage to cables,
excessive number of connections, terminals not made to original specification,
damage to seals, incorrect fitting of glands, etc. Ensure that apparatus is
mounted securely. Ensure that seals or sealing materials have not degraded
such that they no longer serve the purpose of preventing the ingress of
flammable atmospheres. Replacement parts shall be in accordance with the
manufacturer’s specifications.
NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them.
-
Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak. -
Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans. -
Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used. -
Leak detection methods
The following leak detection methods are deemed acceptable for systems containing flammable refrigerants.
Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area). Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum) is confirmed. Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/ extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process. -
Removal and evacuation
When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used. However, it is important that best practice is followed since inflammability is a consideration. The following procedure shall be adhered to:
— Remove refrigerant;
— Purge the circuit with inert gas;
— Evacuate;
— Purge again with inert gas;
— Open the circuit by cutting or brazing.
The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be flushed with OFN to render the unit safe. This process may need to be repeated several times.
Compressed air or oxygen shall not be used for this task.
Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipe-work are to take place.
Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available. -
Decommissioning
Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical power is available before the task is commenced.a) Become familiar with the equipment and its operation.
b) Isolate system electrically.
c) Before attempting the procedure, ensure that:
. mechanical handling equipment is available, if required, for handling refrigerant cylinders;
. all personal protective equipment is available and being used correctly;
. the recovery process is supervised at all times by a competent person;
. recovery equipment and cylinders conform to the appropriate standards.
d) Pump down refrigerant system, if possible.
e) If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
f) Make sure that the cylinder is situated on the scales before recovery takes place.
g) Start the recovery machine and operate in accordance with manufacturer’s instructions.
h) Do not overfill cylinders. (No more than 80 % volume liquid charge).
i) Do not exceed the maximum working pressure of the cylinder, even temporarily.
j) When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
k) Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked. -
Labeling
Equipment shall be labeled stating that it has been de-commissioned and emptied of refrigerant.
The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant. -
Recovery
When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely.
When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge are available. All cylinders to be used are designated for the recovered refrigerant and labeled for that refrigerant (i.e. Special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure-relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of all appropriate refrigerants including, when applicable, flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that it is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recover cylinder, and the relevant waste transfer note arranged. Do not mix refrigerants in recovery units and especially not in cylinders.
If compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers.
Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely.
INSTALLATION PRECAUTIONS(R32)
Important Considerations
- The air conditioner must be installed by professional personnel and the Installation manual is used only for the professional installation personnel! The installation specifications should be subject to our after-sale service regulations.
- When filling the combustible refrigerant, any of your rude operations may cause serious injury or injuries to human body and objects.
- A leak test must be done after the installation completed.
- It is a must to do the safety inspection before maintaining or repairing an air conditioner using combustible refrigerant in order to ensure that the fire risk is reduced to minimum.
- It is necessary to operate the machine under a controlled procedure in order to ensure that any risk arising from the combustible gas or vapor during the operation is reduced to minimum.
- Requirements for the total weight of filled refrigerant and the area of a room to be equipped with an air conditioner (are shown as in the following Tables GG.1 and GG.2) The maximum charge and the required minimum floor area m = (4 m ) x LFL , m = (26 m )) x LFL, m = (130 m )x LFL Where LFL is the lower flammable limit in kg/ m ,R32 LFL is 0.038 kg/ m . For the appliances with a charge amount m < M = m : 1 2 The maximum charge in a room shall be in accordance with the following: (5/4) 1/2 m = 2.5 x (LFL) x h x (A) max 0 The required minimum floor area Amin to install an appliance with refrigerant charge M (kg) (5/4) 2 shall be in accordance with following: A = (M/ (2.5 x (LFL) x h )) min 0 Where:
Table GG.1 – Maximum charge (kg)
Category | LFL (kg/m3) | ho(m) | Floor area (m2) |
---|---|---|---|
4 | 7 | 10 | 15 |
R32 | 0.306 | 1 | 1. |
2. | 2. | 3. | 3. |
2. | 3. | 3. | 4. |
Table GG.2 – Minimum room area (m² )
Category | LFL (kg/m3) | ho(m) | Charge amount (M) (kg) Minimum room area (m2) |
---|---|---|---|
R32 | 0.306 | 1.224kg | |
0.6 | 29 | 51 | |
1 | 10 | 19 | |
2. | 3 | 6 | |
2. | 2 | 4 |
Installation Safety Principles
- Site Safety
- Operation Safety
- Installation Safety
Refrigerant Leak Detector
Appropriate Installation Location The left picture is the schematic diagram of a refrigerant leak detector.Please note that:
1. The installation site should be well-ventilated.
2. The sites for installing and maintaining an air conditioner using Refrigerant R32 should be free from open fire or welding, smoking, drying oven or any other heat source higher than 548 which easily produces open fire.
3. When installing an air conditioner, it is necessary to take appropriate anti-static measures such as wear anti-static clothing and/or gloves.
4. It is necessary to choose the site convenient for installation or maintenance wherein the air inlets and outlets of the indoor and outdoor units should be not surrounded by obstacles or close to any heat source or combustible and/or explosive environment.
5. If the indoor unit suffers refrigerant leak during the installation, it is necessary to immediately turn off the valve of the outdoor unit and all the personnel should go out till the refrigerant leaks completely for 15 minutes. If the product is damaged, it is a must to carry such damaged product back to the maintenance station and it is prohibited to weld the refrigerant pipe or conduct other operations on the user’s site.
6. It is necessary to choose the place where the inlet and outlet air of the indoor unit is even.
7. It is necessary to avoid the places where there are other electrical products, power switch plugs and sockets, kitchen cabinet, bed, sofa and other valuables right under the lines on two sides of the indoor unit. Suggested Tools
Tool | Picture | Tool | Picture | Tool | Picture |
---|---|---|---|---|---|
Standard Wrench | Pipe Cutter | Vacuum Pump | |||
Adjustable/ Crescent Wrench | Screw drivers (Phillips & Flat blade) | Safety | |||
Glasses | |||||
Torque Wrench | Manifold and Gauges | Work Gloves | |||
Hex Keys or Allen Wrenches | Level | Refrigerant Scale | |||
Drill & Drill Bits | Flaring tool | Micron Gauge | |||
Hole Saw | Clamp on Amp Meter |
INSTALLATION PRECAUTIONS
Pipe Length and Additional Refrigerant
Inverter Models Capacity (Btu/h) | 9K-12K |
---|---|
Length of pipe with standard charge | 5m/16ft |
Maximum distance between indoor and outdoor unit | 15m/49ft |
Additional refrigerant charge | 15g/m |
Max. diff. in level between indoor and outdoor unit | 10m/32ft |
Type of refrigerant | R32 |
Torque Parameters
PIPE Size| Newton meter[N x m]| Pound-force foot (Ibf-ft)|
Kilogram-force meter (kgf-m)
---|---|---|---
1/4"(φ6.35)| 18 – 20| 24.4 – 27.1| 2.4 – 2.7
3/8"(φ9.52)| 30 – 35| 40.6 – 47.4| 4.1 – 4.8
1/2"(φ12)| 45 – 50| 61.0 – 67.7| 6.2 – 6.9
5/8"(φ15.88)| 60 – 65| 81.3 – 88.1| 8.2 – 8.9
Dedicated Distribution Device and Wire for Air Conditioner
Maximum Operating Current
of Air Conditioner (A)| Minimum Wire Cross-sectional
Area(mm2)| Specification of
Socket or Switch (A)| Fuse Specification (A)
---|---|---|---
8| 0.75| 10| 20
8 and 10| 1.0| 10| 20
10 and 15| 2.| 16| 32
15 and 24| 3.| 25| 32
24 and 28| 4.0| 32| 64
28 and 32| 6.0| 40| 64
Note: This table is only for reference, the installation shall meet the requirements of local laws and regulations.
INDOOR UNIT INSTALLATION
Step1: Select Installation location
1.1 Ensure the installation complies with the installation minimum dimensions
(defined below) and meets the minimum and maximum connecting piping length and
maximum change in elevation as defined in the System Requirements section.
1.2 Air inlet and outlet will be clear of obstructions, ensuring proper
airflow throughout the room.
1.3 Condensate can be easily and safely drained.
1.4 All connections can be easily made to outdoor unit.
1.5 Indoor unit is out of reach of children.
1.6 A mounting wall strong enough to withstand four times the full weight and
vibration of the unit.
1.7 Filter can be easily accessed for cleaning.
1.8 Leave enough free space to allow access for routine maintenance.
1.9 Install at least 10 ft. (3 m) away from the antenna of TV set or radio.
Operation of the air conditioner may interfere with radio or TV reception in
areas where reception is weak. An amplifier may be required for the affected
device.
1.10 Do not install in a laundry room or by a swimming pool due to the
corrosive environment.
1.11 For ETL certification area, Caution: Mount with the lowest moving parts
at least 8 ft. (2.4 m) above floor or grade level.
Minimum Indoor Clearances
Step2: Install Mounting Plate
2.1 Take the mounting plate from the back of indoor unit.
2.2 Ensure to meet the minimum installation dimension requirements as step 1,
according to the size of mounting plate, determine the position and stick the
mounting plate close to the wall.
2.3 Adjust the mounting plate to a horizontal state with a spirit level, then
mark out the screw hole positions on the wall.
2.4 Put down the mounting plate and drill holes in the marked positions with
drill.
2.5 Insert expansion rubber plugs into the holes, then hang the mounting plate
and fix it with screws.
Note:
(I) Make sure the mounting plate is firm enough and flat against the wall
after installation.
(II) This figure shown may be different from the actual object, please take
the latter as the standard.
Step3: Drill Wall Holes
3.1 Three optional piping modes show be determined
Mode1: Left, the Fresh air pipe, the refrigerant piping ,the drainage pipe,
and connecting cables all are through one hole to the outside.
Mode2: Right, the Fresh air pipe, the refrigerant piping ,the drainage pipe,
and connecting cables all are through one hole to the outside
Mode3: Back, the Fresh air pipe, the refrigerant piping ,the drainage pipe,
and connecting cables go through two side-by-side wall holes.
3.2 For Mode3, follow the reference size for mounting plate and hole to
determine location.
For Mode1 and Mode2, Determine the location of wall hole base on the following size.
3.3 Drill the wall hole with 70mm core drill and with small oblique angle
lower than the indoor end about 5mm to 10mm.
3.4 Place the wall sleeve and wall sleeve cover(both are optional parts) to
protect the connection parts.
Caution:
When drill the wall hole, maker sure to avoid wires, plumbing and other
sensitive components.
Step4: Connecting Refrigerant Pipe
4.1 According to the wall hole position, select the appropriate piping mode.
There are three optional piping modes for indoor units as shown in the figure
below:
In Piping Mode 1 or Piping Mode 3, a notch should be made by using scissors to
cut the plastic sheet of piping outlet and cable outlet on the corresponding
side of the indoor unit.
Note: When cutting off the plastic sheet at the outlet, the cut should be
trimmed to smooth.
4.2 Bending the connecting pipes with the port facing up as shown in the figure.
4.3 Take off the plastic cover in the pipe ports and take off the protective
cover on the end of piping connectors.
4.4 Check whether there is any sundry on the port of the connecting pipe and
make ensure the port is clean.
4.5 After align the center, rotate the nut of the connecting pipe to tighten
the nut as tightly as possible by hand.
4.6 Use a torque wrench to tighten it according to the torque values in the
torque requirements table; (Refer to the torque requirements table on section
INSTALLATION PRECAUTIONS)
4.7 Wrap the joint with the insulation pipe.
Step5: Connect Drainage Hose
5.1 Adjust the drainage hose(if applicable)
In some model, both sides of the indoor unit are provided with drainage ports,
you can choose one of them to attache the drainage hose. And plug the unused
drain port with the rubber attached in one of the ports.
5.2 Connect the drainage hose to the drainage port, ensure the joint is firm
and the sealing effect is good.
5.3 Wrap the joint firmly with teflon tape to ensure no leaks.
Note: Make sure there is no twists or dents, and the pipes should be
placed obliquely downward to avoid blockage, to ensure proper drainage.
Step6: Connect Wiring
6.1 Choose the right cables size determined by the maximum operating current
on the nameplate.
(Check the cables size refer to section INSTALLATION PRECAUTIONS)
6.2 Open the front panel of indoor unit.
6.3 Use a screwdriver, open the electric control box cover, to reveal the
terminal block.
6.4 Unscrew the cable clamp.
6.5 Insert one end of the cable into the position of control box from the back
of the right end of the indoor unit.
6.6 Connect the wires to corresponding terminal according to the wiring
diagram on the electric control box cover. And make sure that they are well
connected.
6.7 Screw the cable clamp to fasten the cables.
6.8 Reinstall the electric control box cover and front panel.
6.9 For some models, the power сables and connection cables are pre-installed
on the machine at the factory.
Step7: Connecting Fresh Air Pipe and place the filter
7.1 According to the wall hole position, select the appropriate piping mode.
Mode1: Left, together with refrigerant piping ,the drainage pipe, and
connecting cables.
Mode2: Right, together with refrigerant piping ,the drainage pipe, and
connecting cables.
Mode3: Back, the fresh air pipe is not bundled with other pipes.
7.2 Measure the length of the fresh air pipe assembly.
Connect the fresh air pipe and the-through-wall pipe assembly to form a fresh
air pipe assembly.
For mode 1:Measure the distance between the left bottom corner of the mounting plate and the center of the wall hole, the length of the fresh air pipe assembly is equal to the measured length plus 650mm.
For mode 2:Measure the distance between the left bottom corner of the mounting plate and the center of the wall hole, the length of the fresh air pipe assembly is equal to the measured length.
For mode 3:The length of the fresh air pipe assembly is 310mm and the exposed length of the fresh air pipe is 50mm. Note:The length of the fresh air pipe assembly refers to the fresh air pipe except the hard pipe through the wall, including the fresh air pipe and soft joints.
Step7: Connecting Fresh Air Pipe and place the filter
7.3 Adjusting the length of the fresh air pipe assembly
According to the installation environment, determine to adjust the length of
fresh air pipe assembly.
7.3.1 Shorten the length
Cut the fresh air pipe to the appropriate length, keeping the section with the
through-wall pipe.
If it is nessary to cut the through-wall pipe assembly due to installation needs. first, cut the through-wall pipe assembly to a suitable length. Then cut a piece of new air pipe of a suitable length. Take out the adapter from the accessory bag, and insert the adapter into the through-wall pipe and fix it firmly with glue.Finally, screw the suitable new air pipe into the adapter.
Note:
- The overlapping part of the adapter and the through-wall pipe needs to be pressed flat with tools and cannot be warped;
- The adapter cannot be forced into the through-wall pipe, otherwise it may cause the con- necting part to warp, and the distance between the round pipe end of the adapter and the through-wall pipe is ≥65mm;
7.3.2 Increase the length
Use the extension joint to connect the appropriate length of fresh air pipe to
the fresh air pipe assembly, make sure the interface is in the middle of the
extension joint, and finally wrap the connection position with tape.
Note:The number of bends of the fresh air pipe and the length of the pipe
will affect the amount of fresh air. It is recommended to use the mode 3 and
avoid increasing the length of the fresh air pipe when the installation
conditions allow.
Step7: Connecting Fresh Air Pipe and place the filter
7.4 Screw the fresh air pipe into the fresh air inlet hole at the back of the
indoor unit.
7.5 Open the indoor panel and take out the filter holder, place HEPA filter for fresh air then restore the holder.
Step8: Wrap Piping and Cable
After the refrigerant pipes, connecting wires and drainage hose are all
installed, in order to save space, protect and insulate them, it must be
bundle with insulating tape before passing them through the wall hole.
8.1 Arrange the pipes ,cables and drainage hose well as the following picture.
Mode1
After arrange all pipes and cables, take the Metal strap supporter out of the
accessories of fresh air. Insert into the slot as the picture to fix the
pipes.
Mode2
After arrange all pipes and cables, take the Metal strap supporter out of the
accessories of fresh air.
Insert into the slot as the picture to fix the pipes.
Mode3
Note: Avoid crossing and bending of parts.
8.2 Using the insulating tape wrap the fresh air pipes, the refrigerant pipes,
connecting wires and drainage hose together tightly.
Step9: Mount Indoor Unit
9.1 Slowly pass the refrigerant pipes, connecting wires and drainage hose
wrapped bundle through the wall hole.
92 Hook the top of indoor unit on the mounting plate.
9.3 Apply slight pressure to the left and right sides of the indoor unit, make
sure the indoor unit is hooked firmly.
9.4 Push down the bottom of indoor unit to let the snaps onto the hooks of the
mounting plate, and make sure it is hooked firmly.
Note:
- The distance between the fresh air inlet and the wall should not exceed 350mm;
- During installation, the fresh air pipe assembly can be rotated at an appropriate angle according to the position of the outdoor unit, so that the connecting pipe does not block the fresh air inlet.
- The fresh air pipe should be slightly inclined downward, and there should be no rising section to prevent rainwater from entering the room.
- If it is necessary to bend the fresh air pipe, the minimum radius of the bend of the fresh air pipe should be greater than 60mm, otherwise it may affect the fresh air effect.
- The fresh air inlet should not be placed in the air outlet of the outdoor unit, in a closed space or in a place with bad air.
OUTDOOR UNIT INSTALLATION
Step1: Select Installation Location
Select a site that allows for the following:
1.1 Do not install the outdoor unit near sources of heat, steam or flammable
gas.
1.2 Do not install the unit in too windy or dusty places.
1.3 Do not install the unit where people often pass. Select a place where the
air discharge and operating sound will not disturb the neighbors.
1.4 Avoid installing the unit where it will be exposed to direct sunlight (
other wise use a protection, if necessary, that should not interfere with the
air flow).
1.5 Reserve the spaces as shown in the picture for the air to circulate
freely.
1.6 Install the outdoor unit in a safe and solid place.
1.7 If the outdoor unit is subject to vibration, place rubber blankets onto
the feet of the unit.
Step2: Install Drainage Hose
2.1 This step only for heating pump models.
2.2 Insert the drainage joint to the hole at the bottom of the outdoor unit.
2.3 Connect the drainage hose to the joint and make the connection well
enough.
Step3: Fix Outdoor Unit
3.1 According to the outdoor unit installation dimensions to mark the
installation position for expansion bolts .
3.2 Drill holes and clean the concrete dust and place the bolts .
3.3 If applicable install 4 rubber blankets on the hole before place the
outdoor unit (Optional).
This will reduce vibrations and noise.
3.4 Place the outdoor unit base on the bolts and pre-drilled holes.
3.5 Use wrench to fix the outdoor unit firmly with bolts.
Note:
The outdoor unit can be fixed on a wall-mounting bracket.
Follow the instruction of the wall-mounting bracket to fix the wall-mounting
bracket on the wall, and then fasten the outdoor unit on it and keep it
horizontal.
The wall-mounting bracket must be able to support at least 4 times of the
weight of outdoor unit.
Step4: Install Wiring
4.1 Use a phillips screwdriver to unscrew wiring cover, grasp and press it
down gently to take it down.
4.2 Unscrew the cable clamp and take it down.
4.3 According to the wiring diagram pasted inside the wiring cover, connect
the connecting wires to the corresponding terminals, and ensure all
connections are firmly and securely.
4.4 Reinstall the cable clamp and wiring cover.
Note: When connecting the wires of indoor and outdoor units, the power
should be cut off.
Step5: Connecting Refrigerant Pipe
5.1 Unscrews the valve cover, grasp and press it down gently to take it
down(if the valve cover is applicable).
5.2 Remove the protective caps from the end of valves.
5.3 Take off the plastic cover in the pipe ports and c heck whether there is
any sundry on the port of the connecting pipe and make ensure the port is
clean.
5.4 After align the center, rotate the flare nut of the connecting pipe to
tighten the nut as tightly as possible by hand.
5.5 Use a spanner hold the body of the valve and use a torque wrench to
tighten the flare nut according to the torque values in the torque
requirements table.
(Refer to the torque requirements table on section INSTALLATION PRECAUTIONS)
Step6: Vacuum Pumping
6.1 Use a spanner to take down the protective caps from the service port, low
pressure valve and high pressure valve of the outdoor unit.
6.2 Connect the pressure hose of manifold gauge to the service port on the
outdoor unit low pressure valve.
6.3 Connect the charge hose from the manifold gauge to the vacuum pump.
6.4 Open the low pressure valve of the manifold gauge and close the high
pressure valve.
6.5 Turn on the vacuum pump to vacuum the system.
6.6 The vacuum time should not be less than 15 minutes, or make sure the
compound gauge indicates -0.1 MPa (-76 cmHg)
6.7 Close the low pressure valve of the manifold gauge and turn off the
vacuum.
6.8 Hold the pressure for 5 minutes, make sure that the rebound of compound
gauge pointer does not exceed 0.005 MPa.
6.9 Open the low pressure valve counterclockwise for 1/4 turn with hexagonal
wrench to let a little refrigerant fill in the system, and close the low
pressure valve after 5 seconds and quickly remove the pressure hose.
6.10 Check all indoor and outdoor joints for leakage with soapy water or leak
detector.
6.11 Fully open the low pressure valve and high pressure valve of the outdoor
unit with hexagonal wrench.
6.12 Reinstall the protective caps of the service port, low pressure valve and
high pressure valve of the outdoor unit.
6.13 Reinstall the valve cover.
TEST OPERATION
Inspections Before Test Run
Do the following checks before test run.
Description | Inspection method |
---|
Electrical
safety inspection| •Check whether the power supply voltage complies with
specification.
•Check whether there is any wrong or missing connection between the power
lines, signal line and earth wires.
•Check whether the earth resistance and insulation resistance comply with
requirements.
Installation
safety inspection| •Confirm the direction and smoothness of drainage pipe.
•Confirm that the joint of refrigerant pipe is installed completely.
•Confirm the safety of outdoor unit, mounting plate and indoor unit
installation.
•Confirm that the valves are fully open.
•Confirm that there are no foreign objects or tools left inside the unit.
•Complete installation of indoor unit air inlet grille and panel.
Refrigerant
leakage detection| •The piping joint, the connector of the two valves of the
outdoor unit, the valve spool, the welding port, etc., where leakage may
occur.
•Foam detection method:
Apply soapy water or foam evenly on the parts where leakage may occur, and
observe whether bubbles appear or not, if not, it indicates that the leakage
detection result is safe.
•Leak detector method:
Use a professional leak detector and read the instruction of operation, detect
at the position where leakage may occur.
•The duration of leak detection for each position should last for 3 minutes or
more;
If the test result shows that there is leakage, the nut should be tightened
and tested again until there is no leakage;
After the leak detection is completed, wrap the exposed pipe connector of
indoor unit with thermal insulation material and wrap with insulation tape.
Test Run Instruction
-
Turn on the power supply.
-
Press the ON/OFF button on the remote controller to turn on the air conditioner.
-
Press the Mode button to switch the mode COOL and HEAT.
In each mode set as below:
COOL-Set the lowest temperature
HEAT-Set the highest temperature -
Run about 8 minutes in each mode and check all functions are properly run and respond the
remote controller. Functions check as recommended:
4.1 If the outlet air temperature respond the cool and heat mode
4.2 If the water drains properly from the drainage hose
4.3 If the Louver and deflectors(optional) rotate properly -
Observe the test run state of the air conditioner at least 30 minutes.
-
After the successfully test run, return the normal setting and press ON/OFF button on the remote controller to turn off the unit.
-
Inform the user to read this manual carefully before use, and demonstrate to the user how to use the air conditioner, the necessary knowledge for service and maintenance, and the reminder for storage of accessories.
Note: If the ambient temperature is excess the range refer to section OPERATION INSTRUCTIONS, and it can not run COOL or HEAT mode, lift the front panel and refer to the emergency button operation to run the COOL and HEAT mode.
MAINTENANCE
Warning| When cleaning, you must shut down the machine and cut off the power
supply for more than 5 minutes.
Under no circumstances should the air conditioner be flushed with water.
Volatile liquid (e.g. thinner or gasoline) will damage the air conditioner, so
only use soft dry cloth or wet cloth dipped with neutral detergent to clean
the air conditioner. Pay attention to cleaning the filter screen regularly to
avoid dust covering which will affect the filter screen effect. When the
operating environment is dusty, the cleaning frequency should be increased
appropriately. After removing the filter screen, do not touch the fins of the
indoor unit to avoid scratching.
---|---
Clean the unit| Tip: Wipe frequently to keep air conditioner
clean and good appearance .
Disassembly and assembly
of filter| Grasp the raised handle on the filter by hand, and then pull the
filter out in the direction deviating from the unit, so that the upper edge of
the filter is separated from the unit. The filter can be removed by lifting
the filter upwards. When installing the filter, first insert the lower end of
the filter screen into the corresponding position of the unit, and then
squeeze the upper end of the filter into the corresponding buckling position
of the unit body.
Clean the filter| Tip: When you find accumulated dust in the
filter, please clean the filter in time to
ensure the clean, healthy and efficient operation inside the air conditioner.
Cleaning or replace filter of
Fresh Air| First, Open the panel and take out the filter holder.
Use a dust catcher to clean the filter or replace a new one.
We suggest replace the filter 6 months or when get the reminder indicator CL
on the indoor display.
Service and maintenance| When the air conditioner is not in use for a long
time, do the following work:
Take out the batteries of the remote controller and disconnect the power
supply of the air conditioner.
When starting to use after long-term shutdown:
1. Clean the unit and filter screen;
2. Check whether there are obstacles at the air inlet and outlet of indoor
and outdoor units;
3. Check whether the drain pipe is unobstructed;
Install the batteries of the remote controller and check whether the power is
on.
TROUBLESHOOTING
MALFUNCTION | POSSIBLE CAUSES |
---|---|
The appliance does not operate | Power failure/plug pulled out. |
Damaged indoor/outdoor unit fan motor.
Faulty compressor thermomagnetic circuit breaker.
Faulty protective device or fuses.
Loose connections or plug pulled out.
It sometimes stops operating to protect the appliance.
Voltage higher or lower than the voltage range.
Active TIMER-ON function.
Damaged electronic control board.
Strange odor| Dirty air filter.
Noise of running water| Back flow of liquid in the refrigerant circulation.
A fine mist comes from the air outlet| This occurs when the air in the room
becomes very cold, for example in the COOLING or DEHUMIDIFYING/DRY modes.
A strange noise can be heard| This noise is made by the expansion or
contraction of the front panel due to variations in temperature and does not
indicate a problem.
Insufficient airflow, eitherhot or cold| Unsuitable temperature setting.
Obstructed air conditioner intakes and outlets.
Dirty air filter.
Fan speed set at minimum.
Other sources of heat in the room.
No refrigerant.
The appliance does not respond to commands| Remote control is not close enough
to indoor unit.
The batteries of remote control need to be replaced.
Obstacles between remote control and signal receiver in indoor unit.
The display is off| Active DISPLAY function.
Power failure.
Switch off the air conditioner immediately and cut off the power supply in the
event of:| Strange noises during operation.
Faulty electronic control board.
Faulty fuses or switches.
Spraying water or objects inside the appliance.
Overheated cables or plugs.
Very strong smells coming from the appliance.
ERROR CODE ON THE DISPLAY
In case of error, the display on the indoor unit shown the following error
codes:
Display | Description of the trouble |
---|---|
Indoor room temperature sensor fault | |
Indoor pipe temperature sensor fault | |
Outdoor pipe temperature sensor fault | |
Refrigerant system leakage or fault | |
Malfunction of indoor fan motor | |
Outdoor ambient temperature sensor fault | |
Indoor and outdoor communication fault | |
Outdoor discharge temperature sensor fault | |
Outdoor IPM module fault | |
Outdoor current detect fault | |
Outdoor PCB EEPROM fault | |
Outdoor fan motor fault | |
Outdoor suction temperature sensor fault | |
Filter cleaning reminder |
DISPOSAL GUIDELINE (European)
This appliance contains refrigerant and other potentially hazardous materials.
When disposing of this appliance,the law requires special collection and
treatment. DO NOT dispose of this product as household waste or unsorted
municipal waste.
When disposing of this appliance, you have the following options:
Dispose of the appliance at designated municipal electronic waste collection
facility.
When buying a new appliance, the retailer will take back the old appliance
free of charge.
The manufacturer will also take back the old appliance free of charge.
Sell the appliance to certifid scrap metal dealers.
Disposing of this appliance in the forest or other natural surroundings
endangers your health and is bad for the environment. Hazardous substances may
leak into the ground water and enter the food chain.
DECLARATIONS
NOTICE ABOUT RECYCLING
Your product is designed and manufactured with high quality materials and
components which can be recycled and reused. This symbol means that electrical
and electronic equipment, at their end-of-life, should be disposed of
separately from your household waste. Please dispose of this equipment at your
local community waste collection/ recycling centre. In the European Union
there are separate collection systems for used electrical and electronic
products. Please help us to conserve the environment we live in!
DECLARATION OF CONFORMITY
Herewith, we declare that this product, complies with the requirements of
below directives:
RED Directive: 14 / 53 / Eu
EMC-Directive: 14 / 30 / EU
Low Voltage Directive: 14/ 35 / EU
ErP Directive 09 / 125 / EC
CE Marking: 93 / 68 / EEC
RoHS Directive: 11 / 65 / EU, delegated Directive (EU) 15/863
Detailed declaration of conformity can be found at
www.morris.gr
Imported by
Kalliopi Karyda & Co LP
87A, 17th Novemeber str
. 55535, Pylea, Thessaliniki
Tel. 2310 944944
Fax. 2310 006650 www.morris.gr