KOHLER 1529822-2-B Touchless Washout Urinal Instruction Manual

June 15, 2024
Kohler

1529822-2-B Touchless Washout Urinal
Instruction Manual

1529822-2-B Touchless Washout Urinal

Thank You for Choosing KOHLER
Need help? Contact our Customer Care Center.

Tools and MaterialsKOHLER 1529822-2-B Touchless Washout Urinal - Tools
and Materials Plus:

  • Conventional woodworking tools and materials
  •  Hole Cutting Equipment
  •  Appropriate Screws
  •  AA Batteries (4)

Before You Begin

CAUTION: Risk of personal injury. Handle this product with care. Vitreous china can break or chip if the product is handled carelessly.
NOTE: Roughing-in dimensions remain the same when using the optional 3″ outlet spud.
Unpack and inspect the product for damage. Return the product to the carton until installation.
Your product may appear different from the one illustrated. The installation procedure is the same.
Fixture dimensions are nominal and conform to tolerances in ASME Standard A112.19.2/CSA B45.1. ADA compliant when the rim is mounted no higher than 17″ (432 mm) from the finished floor. Follow all local plumbing and building codes. Turn OFF the water supplies.

Prepare the Site

KOHLER 1529822-2-B Touchless Washout Urinal - Prepare the
Site

  • Install a backer board for additional support.
  • Install a 2 NPT waste pipe according to the Specification Sheet.
  • Install a 1/2 NPT water supply inlet according to the Specification Sheet.
  • Install the shut-off valve.

Install the Wall Hangers

KOHLER 1529822-2-B Touchless Washout Urinal - Wall
Hangers

  • Position the top holes of the wall hangers 19-9/16″ (497 mm) above the center of the drain pipe.
  • Position the center of the wall hangers 12″ (305 mm) apart and mark each location for the screws.
  • Secure the wall hangers with appropriate screws (not provided).

Install the UrinalKOHLER 1529822-2-B Touchless Washout Urinal -
Urina CAUTION: Risk of personal injury. Handle this product with care. Vitreous china can break or chip if the product is handled carelessly.
CAUTION: Risk of product damage. Do not overtighten the bolts.
NOTE: Do not caulk the top surface of the urinal. Caulk may prevent the tank cover from seating properly.

  • Remove the collar and gasket from the urinal.
  • Apply thread sealant tape to the threads of the drain pipe.
  • Install the collar to the drain pipe.
  • With the beveled surface of the gasket facing away from the collar, place the gasket onto the collar.
  • Secure the urinal to the collar using the washers and bolts provided.

Install the SensorKOHLER 1529822-2-B Touchless Washout Urinal -
Sensor

  • Disassemble the bezel, clamps, nuts, and washers from the urinal.
  • Place the sensor in the urinal.
  • Place the bezel over the sensor and align the two threaded studs through the holes of the clamps.
  • Secure the clamps to the studs with two nuts and two washers.
  • Tighten the nuts until bezel and clamps hold the sensor securely in the hole.

Install the Valve Assembly

KOHLER 1529822-2-B Touchless Washout Urinal - Valve
Assembly IMPORTANT! When disconnecting the control stop from the valve assembly, the gasket will fall out from the end of the valve assembly. Retain the gasket.

  • Using thread sealant tape, wrap the end of the water supply line.
  • Disconnect the control stop from the valve assembly.
  • Retain the gasket from the valve assembly.
  • Attach the control stop to the water supply line.
  • Reinsert the gasket into the end of the valve assembly.
  • Reconnect the control stop to the valve assembly.

Test the Control UnitKOHLER 1529822-2-B Touchless Washout Urinal -
Control Unit Connect

  • Remove the four screws from the cover of the battery compartment. Set the four screws and cover aside.
  • Install four AA batteries (not provided) into the battery compartment.
  • Reinstall the cover to the battery compartment.
  • Plug the solenoid lead into the control unit lead. Wait 10 minutes before proceeding.

Test

  •  Stand in front of the urinal for at least 10 seconds.
  • Step aside from the urinal. The valve will flush after a slight delay.

Check

  • Check the entire installation for leaks. Repair as needed.
  • If cover locks will not be installed, place the cover on the tank. If cover locks will be installed, proceed to the “Install the Locks” section.

Install the LocksKOHLER 1529822-2-B Touchless Washout Urinal -
Locks CAUTION: Risk of product damage. Do not overtighten the locknut.

  • From the inside of the tank, insert a washer and nut into the hole located on the side of the tank.
  • From the outside of the tank, insert a locknut into the hole and through the nut.
  • Tighten the locknut. Do not overtighten the locknut.
  • Repeat the previous steps for the other side.
  • Attach a hook to each side of the cover as shown.
  • Place the cover on the tank.
  • Insert a locking bolt into each locknut and tighten with the provided locking tool.
  • Lift the cover to verify that the cover is properly locked.
  • Adjust the cover lock components, if necessary.

©2023 Kohler Co.
1529822-2-Bkohler.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals