FIXTURE DIAGRAM
PARTS LIST
- [A] Mounting Strap
- [B] MountingScrew (Qty. 2)
- [C] Outlet Box (Not Supplied)
- [D] Strap Mounting Screw (Qty. 2)
- [E] Lock Washer (Qty. 2)
- [F] Knob (Qty. 2)
- [G] Canopy
CAUTION – RISK OF SHOCK:
Disconnect Power at the main circuit breaker panel or main fusebox before
starting and during the installation.
WARNING
- This fixture is intended for installation under the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended. Failure to adhere to these codes and instructions may result in serious injury and/or property damage and will void the warranty.
CLEANING
- Always be certain that the electric current is turned off before cleaning.
- Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.
INSTALLATION INSTRUCTIONS
- Find the appropriate threaded holes on the mounting strap[A] that align with the hole distance in the canopy[G]. Assemble mounting screws[B] into threaded holes starting from the outlet box side.
- Attach the mounting strap to the outlet box[C] using the supplied strap mounting screws[D]. The mounting strap can be adjusted to suit the position of the fixture.
- Grounding instructions: (See Illus. a or b).
- On fixtures where the mounting strap is provided with a hole and two raised dimples, wrap ground wire from the outlet box around the green ground screw, and thread it into a hole.
- On fixtures where a cupped washer is provided, attach the ground wire from the outlet box under the cupped washer and green ground screw, and thread into the mounting strap. If a fixture is provided with ground wire, connect the fixture ground wire to the outlet box ground wire with the wire connector after following the above steps. Never connect ground wire to black or white power supply wires
- Make wire connections. Reference the chart below for correct connections and wire accordingly.
Connect Black or Red Supply Wire to: | Connect White Supply Wire to: |
---|---|
Black | White |
*Parallel cord (round & smooth) | *Parallel cord (square & ridged) |
Clear, Brown, Gold or Black without Tracer | Clear, Brown, Gold or Black with |
Tracer
Insulated wire (other than green) with copper conductor| Insulated wire (other
than green) with silver conductor
*Note: When parallel wire (SPT 1 & SPT 2) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (See illus.)|
-
Raise the canopy to the ceiling, carefully passing mounting screws[B] through mounting screw holes in canopy.
NOTE: Be certain wires do not get pinched between the mounting strap and canopy or canopy and ceiling. -
While holding the canopy in place, use lock washers[E] and knobs[F] to secure the canopy[G]. Tighten to secure.
-
Insert recommended bulb(s). (Not supplied).