ASEPT SS6L-1 Stainless Steel Dispensers User Manual
- June 15, 2024
- ASEPT
Table of Contents
The Dispensing Specialist
ASEPT STAINLESS STEEL
DISPENSERS
User Manual
ASEPT Stainless Steel Dispensers
| Model| Part #
---|---|---
Single| SS6L-1| 10151
Double| SS6L-2| 10156
Triple| SS6L-3| 10161
Quadruple| SS6L-4| 10139
Quintuple| SS6L-5| 10291
Single Drop In| SS6L-1DI| 10266
Double Drop In| SS6L-2DI| 10271
Triple Drop In| SS6L-3DI| 10276
Quadruple Drop In| SS6L-4DI| 10281
Quintuple Drop In| SS6L-5DI| 10286
Complete Pump 10185
Designed for use with standard 1½ gallon pouched condiments and toppings.
Pumps attach to 16mm fitments in pouches.
Safety
All components must be cleaned before first use.
According to food and safety regulations, most foods must be stored and/or
served at certain temperatures or they could become hazardous. Check with
local food and safety regulators for specific guidelines. Be aware of the
product you are serving and the temperature the product is required to
maintain.
IMPORTANT Clean, rinse, sanitize, and dry parts at a minimum of every 24 hours. Always comply with local sanitization requirements.
Cleaning
Disassemble all six (6) parts.
Clean with soap and hot water, rinse, sanitize and dry parts according to
local sanitization requirements.
Use supplied brush to scrub inside parts.
All components are dishwasher safe.
Assembly
Mount the nozzle
onto the end of the pump housing.
Bend the outer portion of the nozzle inside out.
Insert into opening. Tab of nozzle faces towards housing. Flip the outer
portion of the nozzle over the end of tube.
Insert dome
into the pump housing.
Ensure the flaps slide into place.
Press the entire dome firmly, including the top portion.
Insert the dome clip
over the dome and pump housing.
Ensure that the tab on bottom of the dome slides into the opening in the dome
clip.
Attach hose to pump housing
Fit the holes in the hose over the pegs on the pump housing.
Attach connector to hose
Fit the bottom holes on hose over the pegs on the connector.
Piercing end of the connector must face away from pump housing.
Connect pump to pouch
Put new pouch on countertop with fitment facing up. Place piercing end of
connector in center of the fitment. Push firmly until pump snaps into place.
Insert pouch and pump
into the dispenser shroud. Hold end of pouch up while guiding the pump into
the slots inside the front of dispenser.
Insert the lid
Hold the lever up while inserting lid tabs into slots in back of dispenser
shroud.
Prime pump
Press lever several times until food is visible in discharge tube.
Drop-In Dispensers
Add Corner Guards:
Hook first tab into slot.
Push firmly on second tab to Snap into place.
Dimensions for Cutout
| Width
(inches)| idth Depth
(inches)
---|---|---
Single| 6 3/8| 8 ½
Double| 11| 8 ½
Triple| 16 3/8| 8 ½
Quadruple| 21 13/16| 8 ½
Quintuple| 27 3/16| 8 ½
Setting the Portion
Remove locking washer
Use a flathead screwdriver to pry off the locking washer from the pin at the
end of the link arms.
Keep locking washer for step 4.
Remove pin
Slide the pin out from the pair of link arms and portion holes.
Select portion setting
Align holes on link arms
with hole for desired portion setting. Slide pin through all.
Secure pin with locking washer.
ASEPT General Warranty
Liability for defects
Should the products, as delivered, within one (1) year from delivery be shown
to be defective due to defaults in material or manufacturing (“Warranty
Period”), the Supplier undertakes, at its own option (i) to make a
replacement delivery, (ii) to repair or rework the products claimed to be
defective or (iii) to accept return of such product and refund such proportion
of the purchase sum received as corresponds to the returned products. The
Supplier assumes no liability for defects as regards to layout and design of
the products, unless expressly stated in the Agreement.
The Customer shall without undue delay notify the Supplier in writing of any
defect which appears. Such notice shall under no circumstances be given later
than two (2) weeks after the expiry of the Warranty Period.
The Supplier is liable only for defect which appear under the conditions of
operation provided for in the Agreement and under proper use of the product.
The Supplier’s liability does not cover defect which are caused by faulty
maintenance, incorrect erection or faulty repair by the Customer, or by
alterations carried out without the Supplier’s consent in writing. Finally,
the Supplier’s liability does not cover normal wear and tear or deterioration.
Except as expressly specified above, the Supplier has no liability for defects
in the products whatsoever and are under no circumstances responsible for any
direct or indirect losses, damages or costs incurred by the Customer,
including consequential damages.
General limitation of liability
Notwithstanding any other limitation of liability mentioned in the Agreement
including these Terms and Conditions, the Supplier’s liability for damages
under the Agreement shall be limited to the insurance compensation that can be
obtained in accordance with the Supplier’s each valid liability insurance.
Consequential losses
There shall be no liability of either party towards the other party for loss
of production, loss of profit, loss of use, loss of contract or for any other
consequential or indirect loss whatsoever.
Tips & Troubleshooting
Prevent leaks:
Ensure that dome is pushed fully into pump housing.
Ensure that you hear a CLICK when attaching pump to pouch.
Pro Tip: Clean water may be used as lubrication when fitting hose onto pegs
Optimize pouch evacuation: Ensure ramp is in place.
Asept International Inc.
900 Oakmont Ln, Suite 207,
Westmont IL 60559, USA
+1 630-441-5656
info.us@asept.com
Asept International AB
Traktorvägen 17, SE-226 60
Lund, Sweden
+46 46 329 700
info@asept.com
www.asept.com
References