OSCAL PAD18 Tablet PC User Guide

June 15, 2024
OSCAL

OSCAL PAD18 Tablet PC

Product Information

Specifications

  • Product Name: Pad 18 SERIES
  • Language: English
  • Card Slots: SIM/TF Card
  • Ports: Charger/Type-C Port
  • Speaker: Dual Speakers
  • Screen: Front Camera
  • Flashlight: Camera Flashlight
  • Controls: Power Button, Volume+ Button, Volume- Button
  • Microphone: Built-in Microphone
  • Battery: Non-removable Battery
  • SAR: Maximum SAR is 2.0W/kg

Product Usage Instructions

How to Insert the Card

  1. Press the card pin into the side hole to pop out the card tray.
  2. Take out the card slot and place the Nano card or Nano card and TF card with the metal side facing down.
  3. Make sure the bevel angle of the card is aligned with the bevel angle of the card slot and placed in the corresponding card slot.
  4. With the pad facing up, insert the card holder into the pad in the direction of the arrow.

How to Boot

Press and hold the power button for 3-5 seconds to boot the device.

How to Send SMS, MMS

To send an SMS:

  1. Open the SMS app.
  2. Select “New Information”.
  3. Enter a phone number or browse your contacts.
  4. Select “Edit Information” and enter your text.
  5. Send the message.

To send an MMS (video):

  • When writing a text message, you can take a new picture or video.
  • Select or send the picture or video.

Language Switching Settings

  1. Go to the main menu and select “Settings”.
  2. Select “System Setting” and then “Language and Input Method”.
  3. In the “Language and Input Method” menu, select “Language”.
  4. Select the desired language from the available options.
  5. The system will automatically switch to the selected language.

SAR (Specific Absorption Rate)

The maximum electromagnetic radiation absorption ratio (SAR) of this product is 2.0W/kg, in compliance with the national standard GB 21288-2007.

Safety Guidelines

  • The pad should be at least 15 cm away from any medical implant or rhythm adjuster. Avoid putting the device in your coat pocket.
  • Avoid exposing the device and batteries to high temperatures or heat-generating equipment such as sunlight, heaters, microwave ovens, ovens, or water heaters.
  • When charging is complete or not charging, disconnect the charger from the device and unplug it from the power outlet. If the device has a non-removable battery, do not attempt to replace it yourself to avoid damage to the battery or device.
  • Use only approved and compatible power sources to avoid hazards.
  • Do not disassemble or reset the battery, insert other objects, immerse it in water, or subject it to excessive external pressure to prevent battery leakage, short-circuit, and overheating. The company is not responsible for accidents caused by non-standard charging equipment.

FAQ

  • Q: Where can I find the EU declaration of conformity for this product?
    A: The EU declaration of conformity is available at the following internet address: http://www.oscal.hk/ce/.

  • Q: How can I maintain the pad effectively?
    A: To use the pad more safely and effectively, and extend its service life, thoroughly understand the maintenance guidelines provided in the user manual.

OVERVIEW

OSCAL-PAD18-Tablet-PC-fig- \(1\) OSCAL-PAD18-Tablet-
PC-fig- \(2\)

How to insert the card

  • To make sure your pad be able to call, put the SIM card in the following order.
  • Press the card pin into the side hole and then the card tray pops up and pull out it.
  • Take out the card slot and place the Nano card or Nano card and TF card with the metal side facing down. Make sure the bevel angle is aligned with the bevel angle of the card slot and placed in the corresponding card slot
  • With the pad facing up, insert the card holder into the pad in the direction of the arrowOSCAL-PAD18-Tablet-PC-fig- \(5\)

How to boot

  • Non-removable battery
  • Press the power button for 3-5 seconds to boot

How to send SMS, MMS

SMS

  • Open the SMS app
  • Select New Information
  • Enter a phone number or browse your contacts Select Edit Information and enter your text
  • Send

MMS – video

  • When writing a text message
  • Select images, videos or other files you want to add, even  You can take a new picture or video right away.
  • Selecting or sending 

Language switching settings

  • Main menu–settings-system setting– language and input method
  • Language and input method–language–language adding
  • Select the language you need, the system will automatically jump back to the language interface
  • Select the icon after the language bar and drag it to the first one

SAR

  • The maximum electromagnetic radiation absorption ratio (SAR) of this product is ≤2.0W/kg.
  • In line with the requirements of the national standard GB 21288-2007.

Safety- In order to ensure safely using the product, you must strictly abide by the following rules

  • The pad should be at least 15 cm away from any medical implant or rhythm adjuster and never put the device in your coat pocket.
  • Do not expose the device and other batteries together with the high temperatures or heat-generating equipment such as sunlight, heaters, microwave ovens, ovens or water heaters. Overheating of the battery can cause an explosion.
  • When charging is complete or not charging, disconnect the charger from the device and unplug the charger from the power outlet.
  • If the device is equipped with a non-removable battery, do not replace the battery yourself to avoid damaging the battery or device.
  • Use of an unapproved or incompatible power source, hazards.
  • Do not disassemble or reset the battery, insert other objects, immerse in water or other liquids to avoid battery leakage,
  • Do not drop, crush, scratch or puncture the battery to avoid subjecting the battery to excessive external pressure, resulting in internal short-circuit and overheating of the battery.
  • The company does not bear the responsibility for accidents caused by non-standard related charging equipment.
  • Hereby, Shenzhen DOKE Electronic Co., Ltd declares that this radio equipment type is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.oscal.hk/ce/

Maintenance

  • Thoroughly understand the maintenance of this pad to use the pad more safely and effectively, and extend the service life of the pad as much as possible.

  • Please follow the instructions in the manual to open the pad, disassemble the accessories, and do not try other methods.

  • Please avoid falling, knocking or shaking your pad. Rough handling of the pad can cause the screen to rupture, damaging the internal circuit board and the delicate structure.

  • Do not use chemical solvents or detergents to clean your pad. Wipe the pad case with a soft cotton cloth dampened with water or a mild soap.

  • Clean the lens with a clean, dry, soft cloth. (Example: camera lens) and display.

  • If you encounter an abnormal image such as a crash during use, the processing method is as follows: For a pad that cannot remove the battery, please press and hold the
    power button for more than 12 seconds, the pad will be forced to restart (unlock the pad when restarting)

  • It can solve the general bug; for the pad that can remove the battery, please remove the battery, then insert the battery and restart it to solve the bug.

  • When the charger is not in use, please unplug it from the power outlet. Do not connect the battery that has been
    fully charged to the charger for a long time, as overcharging will shorten the battery life.

FCC

Labeling requirements.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Information to the user.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Information to the user.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help. Absorption Rate (SAR) information:

This device meets the government’s requirements for exposure to radio waves. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons regardless of age or health.

FCC RF Exposure Information and Statement
The SAR limit of USA (FCC) is 1.6 W/kg averaged over one gram of tissue. This device was tested for typical body-worn operations with the back of the device kept 0mm from the body. To maintain compliance with FCC RF exposure requirements, use accessories that maintain a appropriate separation distance between the user’s body and the back of the device. The use of belt clips, holsters and similar accessories should not contain metallic components in its assembly. The use of accessories that do not satisfy these requirements may not comply with FCC RF exposure requirements, and should be avoided. Use only the supplied or an approved antenna.

Shenzhen DOKE Electronic Co.,Ltd
Address : 801, Building3, 7th Industrial Zone, Yulv Community, Yutang Road, Guangming District, Shenzhen, China.

IC Warning
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:

  1. This device may not cause interference;
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

The information listed above provides the user with information needed to make him or her aware of a RF exposure, and what to do to assure that this radio operates within the FCC exposure limits of this radio.
The device complies with RF specifications when the device used at 0mm from the body. Third-party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components. Body-worn accessories that do not meet these requirements may not comply with RF exposure requirements and should be avoided. Use only the supplied or an approved antenna.

www.oscal.hk

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals