tbs electronics PSC2000-3500 High Power True Sinewave Inverters Installation Guide

June 5, 2024
tbs electronics

tbs logo

tbs electronics PSC2000-3500 High Power True Sinewave Inverters

tbs electronics PSC2000-3500 High Power Pure Sine Wave
Inverters

INSTALLATION GUIDE

  •  Please read this document very carefully to avoid product malfunction, shock and/or fire hazards!
  •  This document provides a brief overview of a stand alone product installation. For long term safe and troublefree operation, it is very important to read the enclosed owner’s manual as well!

UNPACKING

The package should contain the following items :

  •  Powersine Combi
  •  Wall bracket
  •  temperature sensor (3m)
  •  Owner’s manual
  • product shows any mechanical
  •  WEEE flyer
  •  7x Mounting screws
  •  Charger warning stickers
  •  Safety flyer
  •  2x M10 crimp terminals

After unpacking, check if the  This Installation guide damage. Never use the product when the enclosure shows any visual damage caused by harsh handling, or when it has been dropped accidentally. Contact your local supplier for further information

MOUNTINGtbs electronics PSC2000-3500 High Power Pure Sine Wave Inverters
1

WIRING DETAILS

tbs electronics PSC2000-3500 High Power Pure Sine Wave
Inverters 2

  • Please consult the following table to determine the correct battery cable size for each model. The given cable sizes are valid for cables installed in free air. Using a smaller cable size or a longer cable may cause the inverter to shutdown under heavy load. Fire and burning hazards are present if the battery cables are insufficiently sized for the expected current. Battery cable lengths longer than 3 meters, are not recommended.tbs electronics PSC2000-3500 High Power Pure Sine Wave Inverters 3

  • The AC input must be protected by a fuse or magnetic circuit breaker (MCB) rated at 30A or less and wiring must be sized accordingly (check local regulations). If the AC input supply is rated at a lower value, the fuse or MCB should be downsized accordingly.

  • An earth leakage circuit breaker with overcurrent protection (RCBO) rated to support the expected load, must be included in series with the AC output. The AC output wiring must be sized accordingly. Please take into account that with the AC Power Boost feature enabled, the Powerline Combi can add roughly 12A to the output during periods of peak power demand. Assuming a maximum transfer switch utilization, the total output current can reach a level of 30A + 12A = 42A. Therefore the maximum RCBO rating is 40A. AC load connection

  • Programmable relay 1 is configured standard as an alarm relay. This means that it will be activated once the Powersine Combi shuts down and jumps to an error mode. Relay 2 will be activated only a few minutes after the AC supply has become available.

  • In case of battery operation, Relay 2 will deactivate immediately. This can be used to switch less critical AC loads (i.e. electric boiler, aircon) on and off that are allowed to be supplied by the mains or generator only. Always include a 16A fuse in series with the
    programmable relay contacts.

  • The required contact specifications for the trigger switches are 5V/5mA. The required contact specifications for the remote switch are 60V/10mA. The maximum wire length between the switch and the Powersine Combi is 30m. The remote switch will only
    operate when the main on/off switch is either in position I or II.

  • The battery temperature sensor must be attached to the main battery. An optional remote control will only operate when the main on/off switch is either in position I or II. In this case the power switch on the remote control panel will be used to turn the
    Powerline Combi on and off.

  • The secondary charger output is limited to approximately 4A and has a slightly lower output voltage compared to the main battery connection. This output is intended to maintain the capacity of a starter battery and is diode isolated from the main connection. A battery fuse of 10A should be installed in this line. A wire size of at least 2.5mm² should be used for this output.

INSTALLATION WARNINGS

  • The schematic on the right shows a typical standalone installation. No guarantees are given on the compliance of any local electrical regulations. Please make sure that the complete installation is made in accordance to all locally applicable electrical regulations. WARNING
  • This Class I product must be earthed! Always connect the PE wire or chassis ground screw between the fans to your central ground (vehicle chassis, grounding system of your boat etc.)
  • This product is equipped with a ground relay that automatically connects the output Neutral to the chassis (PE) in inverter mode (AC transfer switch is open). When AC is present at the input, the ground relay will open just before the AC transfer switch closes. This behaviour enables correct operation of an earth leakage circuit breaker (GFCI/RCD) that is connected to the output.
  • To reduce the risk of explosion, never use this product in locations where there is danger of gas- or dust explosions or where ignition-protected equipment is mandatory. Never install the charger directly on top of the battery or vice-versa.
  • Always connect the negative (-) cable directly on the negative terminal of the battery, or on the “load side” of a current shunt. Always keep positive and negative cables close to each other to minimize electromagnetic fields. Double check for correct polarity, before connecting the battery cables to the battery!
  • Heavy load hazard. Take care when lifting the unit by yourself. The use of two people to lift and mount the unit is preferred. Make sure that the wall can easily support a load of 20 kilos. Use appropriately sized screws. Mount the inverter/charger before connecting any wires or cables.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>