PCE-ITE 50 Electrical Tester User Manual
- June 15, 2024
- PCE
Table of Contents
PCE-ITE 50 Electrical Tester
Product Information
Specifications
- LOOP Resistance L-PE (Hi-Amp) Range (Cl): 0.23-9.99 Ω, 10.0-99.9 Ω, 100-999 Ω
- Resolution: 0.01 Ω, 0.1 Ω, 1 Ω
- Measuring Current: 4.0 A
- Range of the Voltage Used: 195V a.c.-260V a.c. (50,60Hz)
- Power Source: Battery
- Battery Life: 2000m
- CAT Rating: 500mA Fast response
- Protection Classification: BS 88 Fuse
- Protection Rating: IP30
- LCD Screen Type: 320X(RGB)X240 color active matrix
- Pixels: Display 30 seconds (time-delayed)
- Operating Temperature: -10°C to +50°C
- Relative Humidity: 85% max
- Storing Temperature: -20°C to +60°C
- Operating Altitude: Up to 2000m
- Protective Device: Beeper Lock Hold Datalog Bluetooth
- Dimensions: 24.2cm(L) x 10.5cm(W) x 14.5cm(H)
- Weight: 1.56kg
Instrument Overview
Front View
- Starts the selected test. The T key is surrounded by a touch pad. The touch pad measures the potential between the operator and the tester’s PE terminal. If you exceed a 100 V threshold, the D symbol above the touch pad is illuminated.
- Warning lamp
- 320X(RGB)X240 color active matrix display
- Press and hold turns the tester on and off. Short press returns the latest status.
- Function selector switch
- Navigation keys: Enter, Up, Down, Left, Right
- Selects the sub-menus from the Test Mode selected by the rotary switch F1, F2, F3, F4
- Accesses help menus
- No. Annunciator
- Low battery icon. Indicates the battery status.
- Beeper Lock Hold Datalog Bluetooth
- Appears when the instrument is overheated.
- Display 30 seconds (time-delayed)
- Being tested
- Primary display and measurement units
- Primary display and measurement units
- Fault voltage. Measures neutral to earth. Indicates the preset fault voltage limit.
- Arrows above or below the terminal indicator symbol indicate reversed polarity. Check the connection or check the wiring to correct.
Product Usage Instructions
Caution
Do not change functions on the test instrument with the test leads in
place, i.e. changing from a dead test to a test where the supply is required
could damage the instrument.
Declaration of Conformity
This instrument has been tested according to the below regulations:
- EN 61326: Electrical equipment for measurement, control and laboratory use.
- EN 61010-1: Safety requirements for electrical equipment for measurement, control and laboratory use.
Error Codes
Various error conditions are detected by the tester and are indicated with
the icon, Err, and an error number on the primary display. See Table 1 for the
error codes and their respective solutions.
Error Condition | Code | Solution |
---|
Check the installation, in particular, the voltage between N
and PE.| Fault Voltage| Check the voltage between N and PE.
Wait while the tester cools down.| OverTemp| Allow the tester to cool down
before resuming testing.
Switch off all appliances (Loop, RCD measurements) and move the
earth stakes (earth measurement).| Excessive Noise| Turn off all appliances
and adjust the position of the earth
stakes.
Put the stakes deeper into the soil. Tamp down the soil
directly around the stakes. Pour water around the stakes but not at
the earth under test.| Excessive Probe Resistance| Adjust the position of the
stakes and ensure proper soil
contact.
Return the tester to a Service Center.| Self Test Fails| Contact a Service
Center for assistance.
FAQ
Q: Where can I find more information about the product?
A: More information about our products can be found by using our product
search on our website: www.pce-instruments.com.
Q: How do I check the battery status?
A: The battery status is indicated by the low battery icon on the
instrument’s display. For additional information on batteries and power
management, refer to the user manual.
User Manual
Insulation Tester PCE-ITE 50
User manuals in various languages (français, italiano, español, português,
nederlands, türk, polski, ,
) can be found by using our product search on: www.pce-instruments.com
Last change: 27 May 2020 v1.0
© PCE Instruments
····
Mihr&J.i,W&i4#14W&t.-····
1.4-Caution Do not change functions on the test instrument wtththetest leads
in place, i.e. changing from a “dead test”
to a test where the supply is required could damage the instrument.
1.5-Declaration of Conformity This instrument has been tested according to the
below regulations: EN 61326: Electrical equipment for measurement, control and
laboratory use. EN 61010-1: Safety requirements for electrical equipment for
measurement, control and laboratory use
-Part 1: General requirements. BS EN61557: Electrical safety in low voltage distribution systems up to 1000V a.c. and 1500V d.c. Equipment for testing, measuring or monitoring of protective measures. · Part 1 General requirements · Part 2 lnsulation resistance · Part 3 Loop resistance · Part 4 Resistance of earth connection and equipotential bonding · Part 6 Residual current devices (RCDs) in TT and TN systems · Part 7 Phase sequence · Part 10 Combined measuring equipment
1.6-Error Codes Various error conditions are detected by the tester and are
indicated with the icon, ” Err”, and an error
number on the primary display. See Table 1. These error conditions disable
testing and, if necessary, stop a running test. Table 1. Error Codes
Error Condition Code Code Solution
Solution
1 Check the installation, in particular, the voltage
Fault Voltaae
between N and PE.
OverTemp
2 Wait while the tester cools down.
Excessive Noise
3 Switch off all appliances (Loop, RCD measurements)
and move the earth stakes (earth measurement).
Excessive Probe
4 Put the stakes deeper into the soil. Tamp down the
Resistance
soil directly around the stakes. Pour water around
the stakes but not at the earth around under test.
Seif Test Fails
5 Return the tester to a Service Center.
2-Specification LOOP Resistance L- PE (Hi-Amp)
Range (Cl) Resolution(Q) 0.23-9.99 0.01 10.0-99.9 0.1 100-999 1
Accuracy ± (4% of reading+ 4digits)
Measuring Current: 4.0 A Range of the Voltage Used: 195V a.c.-260V a.c. (50,60Hz)
···· -.e@&&h·&IMH4Wiiri’Fih
3-General Specification Power Source
Battery Life CAT Rating Protection Classification Protection Rating LCD Screen
Type Pixels Operating Temp
Relative Humidity Storing Temp Operating Altitude Protective device Dimensions
Weight
8 x 1.5V AA Size Alkaline batteries or 8 x 1.2V AA Size rechargeable Ni-MH
batteries Average of 15hours CAT 11I600V Double lnsulation lp65 3.5″TFT
320×240 0°c- 45°c 95% 10°C~ 30°C: Non-condensing 75% 30°C- 40°C -10°C- 60°C
2000m 500mA Fast response BS 88 Fuse 24.2cm(L) x 10.5cm(W) x 14.5cm(H) 1.56kg
4-lnstrument Overview 4.1-Front View 1-Starts the selected test. The T key is
surrounded by a “tauch pad”. The tauch pad measures the potential
between the operator and the tester’s PE terminal. lf you exceed a 100 V
threshold, the D symbol above the tauch pad is illuminated. 2-Warning lamp
3-320X(RGB)X240 color active matrix 4-Press and hold Turns the tester on and
off. Short Press return the latest status. 5-Function selector switch.
6-Navigation keys: Enter, Up, Down, Left, Right 7-Selects the sub-menus from
the Test Mode selected by the rotary switch F1, F2, F3, F4 8-Accesses help
menus.
, ____
27 3
8
···· -.e@&&h·&IMH4Wiiri’Fih
No. Annunciator 6
Meaning Low battery icon. See
:lndicates the battery status.
:100% :80% :50% :20%
:Low Battery for additional information on batteries and power management.
Beeper Lock Hold Datalog Bluetooth Appears when the instrument is overheated.
Display 30 seconds (time-delayed) Being tested Primary display and measurement
units.
Primary display and measurement units.
Fault voltage. Measures neutral to earth. lndicates the preset falut voltage
limit. Arrows above or below the terminal indicator symbol indicate reversed
polarity. Check the connection or check the wiring to correct.
N-PE Value L-N Value L-PE Value Prospective Earth Fault Curremt. Calculated
from voltage and loop impedance which is measured line to protective earth.
Prospective Short Circuit. Calculated from measured voltage and impedance when
reading line to neutral. Being tested
Hiah Voltaae Warnina Warning
3 Contact
If you have any questions, suggestions or technical problems, please do not
hesitate to contact us. You will find the relevant contact information at the
end of this user manual.
4 Disposal
For the disposal of batteries in the EU, the 2006/66/EC directive of the
European Parliament applies. Due to the contained pollutants, batteries must
not be disposed of as household waste. They must be given to collection points
designed for that purpose. In order to comply with the EU directive 2012/19/EU
we take our devices back. We either re-use them or give them to a recycling
company which disposes of the devices in line with law. For countries outside
the EU, batteries and devices should be disposed of in accordance with your
local waste regulations. If you have any questions, please contact PCE
Instruments.
© PCE Instruments 6
PCE Instruments contact information
Germany
PCE Deutschland GmbH Im Langel 4 D-59872 Meschede Deutschland Tel.: +49 (0)
2903 976 99 0 Fax: +49 (0) 2903 976 99 29 info@pce-
instruments.com
www.pceinstruments.com/deutsch
Germany
PCE Produktions- und Entwicklungsgesellschaft mbH Im Langel 26 D-59872
Meschede Deutschland Tel.: +49 (0) 2903 976 99 471 Fax: +49 (0) 2903 976 99
9971
info@pceinstruments.com
www.pceinstruments.com/deutsch
The Netherlands
PCE Brookhuis B.V. Institutenweg 15 7521 PH Enschede Nederland Telefoon: +31
(0)53 737 01 92 info@pcebenelux.nl www.pce-
instruments.com/dutch
United States of America
PCE Americas Inc. 711 Commerce Way suite 8 Jupiter / Palm Beach 33458 FL USA
Tel: +1 561-320-9162 Fax: +1
561-320-9176 info@pce-
americas.com www.pce-
instruments.com/us
France
PCE Instruments France EURL 23, rue de Strasbourg 67250 Soultz-Sous-Forets
France Téléphone: +33 (0) 972 3537 17 Numéro de fax: +33 (0) 972 3537 18 info
@pce-france.fr
www.pce-instruments.com/french
United Kingdom
PCE Instruments UK Ltd Unit 11 Southpoint Business Park Ensign Way,
Southampton Hampshire United Kingdom, SO31 4RF Tel: +44 (0) 2380 98703 0 Fax:
+44 (0) 2380 98703 9 info@industrial-needs.com www.pce-instruments.com/english
China
PCE (Beijing) Technology Co., Limited 1519 Room, 6 Building Zhong Ang Times
Plaza No. 9 Mentougou Road, Tou Gou District 102300 Beijing, China Tel: +86
(10) 8893 9660
info@pce-instruments.cn www.pce-
instruments.cn
Turkey
PCE Teknik Cihazlari Ltd.ti. Halkali Merkez Mah. Pehlivan Sok. No.6/C 34303
Küçükçekmece – stanbul Türkiye Tel: 0212 471 11 47 Faks: 0212 705 53 93 info
@pce-cihazlari.com.tr www.pce-
instruments.com/turkish
Spain
PCE Ibérica S.L. Calle Mayor, 53 02500 Tobarra (Albacete) España Tel. : +34
967 543 548 Fax: +34 967 543 542 info@pce-iberica.es www.pce-instruments.com/espanol
Italy
PCE Italia s.r.l. Via Pesciatina 878 / B-Interno 6 55010 Loc. Gragnano
Capannori (Lucca) Italia Telefono: +39 0583 975 114 Fax: +39 0583 974 824
info@pce-italia.it
www.pce-instruments.com/italiano
Hong Kong
PCE Instruments HK Ltd. Unit J, 21/F., COS Centre 56 Tsun Yip Street Kwun Tong
Kowloon, Hong Kong Tel: +852-301-84912 jyi@pce-instruments.com www.pce-instruments.cn
© PCE Instruments 7
References
- France.fr : Explore France and its wonders - Explore France
- iberica.es
- instruments.cn - The domain is available for purchase
- Computer Instruments | Home
- Discover Italy: Official Tourism Website - Italia.it
- N.E.E.D.S., (Nutritional Ecological Environmental Delivery System) specializes in providing products, information, and education
- PCE(北京)科技有é™å…¬å¸
- PCE Teknik Cihazlar Paz. Tic. Ltd.Şti. | PCE Instruments
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>