PCE-HM Series Heating Mantle User Manual

June 3, 2024
PCE

PCE-HM Series Heating Mantle

PCE-HM-Series-Heating-Mantle-product

Safety notes

Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non- observance of the manual are excluded from our liability and not covered by our warranty.

  • The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
  • The instrument may only be used if the environmental conditions (temperature, relative humidity, …) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
  • Do not expose the device to shocks or strong vibrations.
  • The case should only be opened by qualified PCE Instruments personnel.
  • Never use the instrument when your hands are wet.
  • You must not make any technical changes to the device.
  • The device must only be used with accessories from PCE Instruments or equivalent.
  • Before each use, inspect the case for visible damage. If any damage is visible, do not use the device.
  • Do not use the instrument in explosive atmospheres.
  • The measurement range as stated in the specifications must not be exceeded under any circumstances.
  • Wear safety equipment, such as goggles, gloves or breathing masks to protect yourself against splashing liquids and escaping gases.
  • Place the device on a flat, clean, non-slip and fire-proof surface.
  • The set temperature has to be at least 25 °C lower than the flash point of the material to be heated.
  • Make sure that the flask is not filled too far, especially when working with inflammable or corrosive liquids. The liquids might overboil and leak from the flask which might cause damage to the equipment or to persons.
  • Make sure that the flask is dry from the outside.
  • Pathogenic materials should only be heated in closed vessels.
  • Inspect the flasks for visible damage before heating. Do not heat up damaged flasks.
  • Non-observance of the safety notes can cause damage to the device and injuries to the user.

We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of business. If you have any questions please contact PCE Instruments. The contact details can be found at the end of this manual.

Safety symbols

Safety-related instructions the non-observance of which can cause damage to the device or personal injury carry a safety symbol.

Warning: hot surface

  • Non-observance can cause burns.

Specifications

Technical specifications

Model PCE-HM

Capacity (ml)

| ****

1000

| ****

5000

Power supply| 220V, 50/60Hz

110V, 50/60Hz


Temperature range

| ****

0 … 450°C


Power (W)

| ****

350

| ****

800

Operation| Continuous
Operating conditions| Temperature: +5 … +40 °C

Humidity: 0 … 90 % RH

Dimensions| Ø 280 x 220 mm
Weight| approx. 4kg

Delivery contents

  • 1 x heating mantle PCE-HM 1000 or 5000
  • 1 x power cable
  • 1 x instruction manual

Getting started

The web of the heating mantle is lubricated. Before using the device for the first time, you should heat it up without a flask. When doing so, there is the possibility of smoke generation. Wait for the smoke to vanish. The heating mantle is now ready to use.

Operation

To use the heating mantle, follow these steps:

  1. Place the heating mantle on a stable, clean, non-slip and fire-proof surface.
  2. Fill a flask with the liquid to be heated. Make sure that you do not overfill the flask.
  3. Place the flask on the web of the heating mantle.
  4. Turn on the device. The red lamp illuminates.
  5. Turn the rotary switch to the desired position to start the heating process. The green lamp illuminates.
  6. The lamp glows brighter or darker, depending on the set temperature.

ATTENTION: Do not touch the flask or the upper body of the heating mantle when it is in use.

Maintenance

Clean the heating mantle on a regular basis to increase its life span. Depending on the contamination, use isopropyl alcohol, water or water- containing tensides. Before cleaning, make sure that the device is turned off and that the power line is unplugged. Wear proper protective gloves during the cleaning.

Contact

If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.

Disposal

For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose. In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law. For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations. If you have any questions, please contact PCE Instruments.

www.pce-instruments.com

PCE Instruments contact information

Germany

United States of America

China

United Kingdom

Spain

Hong Kong

© PCE Instruments 9

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals