tado V3 Wireless Smart Thermostat Starter Kit Instruction Manual
- June 15, 2024
- Tado
Table of Contents
- tado V3 Wireless Smart Thermostat Starter Kit
- Manual for Professional
- Install the Internet Bridge
- Pair the Wireless Temp. Sensor
- Mount tado˚ devices
- Extra information: Wireless Receiver Symbols
- Wire the Wireless Receiver
- Potential Free Relay
- Digital
- Analog
- Pair the Wireless Receiver
- Configuration
- Boiler Configuration ONLY for Viessmann KM-Bus
- Test the system
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
tado V3 Wireless Smart Thermostat Starter Kit
Product Information
- The Wireless Smart Thermostat V3+ is a professional-grade thermostat designed for easy installation and efficient temperature control. This thermostat comes with an Internet Bridge for remote access and control, as well as a Wireless Receiver and Wireless Temperature Sensor for accurate temperature readings.
Specifications
- Model : Wireless Smart Thermostat V3+
- Manual Version: 3.2
- Language Options : English, German, Italian, Spanish, French, Dutch
Manual for Professional
Installers
- For the Starter Kit – Wireless Smart Thermostat V3+ English International
- This manual is meant exclusively for professional installers. It includes generic instructions to install the Wireless Receiver and the Wireless Temperature Sensor.
Manual version 3.2
DIY Installation
If you are not a professional installer, please download the tado˚ app. There
you will find specific installation instructions.
Install the Internet Bridge
- A. Connect the Internet Bridge to the router.
- If no free USB port is available on the router, use the included 5V power adapter.
- B. Press and hold the pairing button until the pairing LED starts blinking.
Pair the Wireless Temp. Sensor
- A. Remove the battery protection strip.
- B. Press the button for 3 sec to start pairing.
- C. Pairing may take up to 2 min.
- D. The static icon below indicates successful pairing.
If pairing fails (E0), make sure the distance between the devices is approximately 3 meters. Pair again by pressing the button for 3 sec.
Mount tado˚ devices
- A. Mount the Wireless Temperature Sensor to the wall using the included screws or the adhesive pads.
- B. Mount the Wireless Receiver to the wall using the included screws.
Extra information: Wireless Receiver Symbols
When tado˚ is requesting heat, the Heat request symbol will either fade in and out or be solid ON. When OFF, tado° is not requesting heat.
Unfold to check
Step 4: Wire the Wireless Receiver Step 5: Pair the Wireless Receiver Step 6:
Configuration
Wire the Wireless Receiver
Caution!
Turn OFF the power before wiring!
- Always use the included strain reliefs and position them on the outer insulation layer of the cable.
Check the boiler manual before
wiring. Identify the control interface and check if it is supported by tado ̊.
The factory default configuration is Relay. If the Wireless Receiver is wired via Relay, step 6 (configuration) can be skipped.
Potential Free Relay
230V Relay
Manufacturer| Control Interface| Config.| Hot Water|
tado˚ terminals|
---|---|---|---|---|---
| | Menu ID| control| COM| NO
Various| Potential Free Relay| R01| | RT| RT
Various| 230V Relay| R01| | L| SL
Digital
Manufacturer| Control interface| Config. Menu ID| Hot Water control| tado˚ terminals
– +
|
---|---|---|---|---|---
Various| Opentherm| D01| | OT(-)| OT(+)|
Vaillant, Glowworm,| Vaillant-e-Bus *, | D07| **| eBUS(-)| eBUS(+)|
Heatline, Saunier Duval,| Vaillant-e-Bus*| D05| | eBUS(-)| eBUS(+)|
AWB, Bulex, Hermann| (with VRC 430/470)| | | |
Junkers, Worcester, e.l.m. leblanc, Bosch| HT-Bus| D17| B|
B|
Buderus, Nefit, Sieger,| EMS-Bus| D31| EMS (1)| EMS (2)|
Bosch| EMS+ Bus| D27| EMS (1)| EMS (2)|
| UBA-Bus| D24| 3| 4|
Chaffoteaux, Ariston| Chaffoteaux Ebus/BridgeNet| D57| T| B|
Elco, Brötje, Atlantic, Chappee, Baxi, BaxiRoca| BS-Bus| D62|
CL-| CL+|
Wolf| Wolf-eBus| D45| eBus(1)| eBus(2)|
Viessmann| KM-Bus***| D37| KM-Bus| KM-Bus|
- *VR33 OpenTherm translation module (in the Netherlands) should be removed.
- Only compatible with one heating circuit. Any existing fit-in controller should be removed. ***Special configuration is needed on the boiler for KM-Bus interface, see table on backpage.
Analog
Manufacturer| Control interface| Config. Menu ID| Hot Water control| tado˚ terminals
A
| ****
–
| ****
+
---|---|---|---|---|---|---
Junkers| Junkers 1-2-4 24V| A01| | 2| 4| 1
Vaillant| Vaillant 7-8-9 24 V| A07| | 7| 9| 8
Wolf| Wolf 1-2-3 24V| A08| | | 0V| 24V
Pair the Wireless Receiver
- A. Put the cover on the device. Tight the housing screw to secure it.
- B. Plug in the power supply cable and turn the power back ON.
- C. Wait 30 sec, then press the button for 3 sec to start pairing.
- D. Solid on indicates successful pairing.
Configuration
Use the Wireless Temperature Sensor to configure the Wireless Receiver interface according to the tables above (Hot Water control & Config. Menu ID).
- A. Press the button for 3 sec and release.
- B. Press the button for 3 sec again and release.
- C. Press the button for 3 sec again and release.
- D. Please wait while the installer menu loads.
- E. Press the button when TS is displayed to continue.
- F. Press the button when HC01 is displayed to confirm.
- G. Based on interface, activate Hot Water control.
- H. Press the button when EK is displayed to continue.
- I. Select the Config Menu ID according to the table.
- J. Save configuration by pressing the button.
Boiler Configuration ONLY for Viessmann KM-Bus
Test the system
- A. Adjust to maximum temperature.
- B. Wait 3 min and check if the heating is ON.
- C. Turn the heating back OFF and check after 3 min.
- D. Your tado° installation is complete.
Need help?
- Find additional Professional Installer Manuals here.
- Find more information on error codes in our Help Center.
- Register on our tado° Professional site for help, tips, and more information.
tado.com/professional-manuals tado.com/support Get expert advice on our tado° installer hotline: +44 20 3893 2159 tado.com/installers
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>