APRVTIO ALD-50 Combustible Gas Leak Detector

Technical Specifications

  • Product Name: ALD-50 Combustible Gas Leak Detector
  • Detection Principle: Heated diode detection
  • Sensor Life: Longer than traditional leak detectors
  • Detection Accuracy: Higher accuracy
  • Operation: Easy to operate
  • Range of Detection: Wide range of combustible gases

The ALD-50 Combustible Gas Leak Detector is a hand-held leak detector that uses the heated diode detection principle. Compared with the traditional leak detector, its sensor has a longer life, higher detection accuracy, is easier to operate, and can detect a wider range of combustible. The ALD-50 has an ergonomic design and a large LCD screen for easy viewing.

Structure

  1. Flexible probe
  2. Case
  3. Probe tip
  4. USB Port
  5. Buzzer
  6. Battery
  7. Peak
  8. Leak
  9. Sensitivity
  10. Button

Setup

  • Check the device has sufficient battery level.Turn on ( on/off button ) and wait for 30 seconds before testing.
  • Adjust the sensitivity ( sens ).

APRVTIO-ALD-50-Combustible-Gas-Leak-Detector-fig-4

  • Slowly move probe ( approx 3 inch/sec ) at a distance of 0.25 inch near suspected leak area.
  • Detection: when a leak is detected, the screen will show the intensity of the leak and audible tone will change to a siren sound.

APRVTIO-ALD-50-Combustible-Gas-Leak-Detector-fig-5

Key Operation

  • ON/OFF key : press the button for 2 seconds to power on/off.
  • RSET key: Long press the button for 3 seconds to reset the sensitivity benchmark.
  • PEAK key: press the button to record the maximum value of leakage.
  • SENS key: press the button to adjust sensitivity levels. By default, sensitivity is set to medium.
  • MUTE key : press the button to turn on/off the buzzer.

Specifications

  • Sensor principle: heated diode
  • Sensor life : 500 hours
  • Sensitivity: 100ppm(100ppm-1000ppm) / yr
  • Alarm mode : sound and light alarm, LCD display
  • Battery: built-in rechargeable lithium battery 3.7V 3000mAh
  • Working time: continuous 6H
  • Charging: 4 hours
  • Operating environment: -10°C to 52°C/ Relative humidity ( 20% to 85% RH )
  • Storage temperature: – 20°C to 60°C (-4°F to 140°F)
  • Weight: 415g (14.6oz)
  • Size: 201mm86mm 38mm (7.9″ 3.3″ 1.5 “)
  • Certification: CE certification

Notices

  • Do not submerge the product in water or allow water to enter the intake of the probe.
  • Do not expose the product to temperatures exceeding 60°C.
  • Do not leave the product in direct sunlight for long periods of time.
  • Do not dismantle or attempt repairs of the product without authorization.
  • Do not change or replace the included lithium battery.
  • Do not leave for more than 6 months without charging the battery to prevent damage.
  • Do not use on objects with a charge or appliances connected to a power source.
  • Ensure the filter is present and clean before performing a test.
  • Ensure there is enough power before performing a test.
  • Use only the supplied charging cable.
  • Avoid breathing combustible gases. High concentrations of flammable gases are harmful and may cause unconsciousness or death.
  • ln case of any technical problems please contact us.

SCANER