Thank you for purchasing the WJL-6000. Incorporated with advanced leak detect technology,WJL-6000 is a product with the functions of easy operation, stable function and small appearance. It’s an ideal and economic halogen leak detector.
Structure:
- Sensing tip
- Flexible probe
- Indicator light
- Buzzer
- Power on/off and sensitivity adjusting faucet
- Battery compartment
- Shell
Battery Installation
| Step 1: Open and take the battery rack out of the device.
---|---
| Step 2: Install total 4 x AAA batteries.
| Step 3: Return the battery rack to the device.
Setup
|
---|---
– Power (on/off): Rotate the button. A conti nuous beep tone will
indicate the unit is normally functioning. Check the battery voltage
level by observing the power indicator.| – Power (on/off): short press power
button.
– Wait for 6s to warm up after the unit is switched on. Adjust appropriate
sensitivity or adjust the sensitivity at any time during operation. This
adjustment will not interrupt detection.
|
– Hold the device to the possibly leaking area.| – When a leak refrigerant is
detected, the buzzer will beep in a higher frequency. The light indicator will
flash quickly at the same time.
Specifications
- Operating temperature: 0 °C – 52 °C
- Maximum sensitivity: 6 gr/yr, for all halogenated refrigerants
- Battery life: approx 50 hours of normal use
- Response time: instant
- Work mode: continuous, no limitations
- Fixed probe length: 20 cm
- Dimension: 22.9 x 6.5 x 6.5 mm
- Warm up time: 6 seconds approx
- Power supply: 4 x 1.5V DC AAA # batteries(no included)
FAQ
Why does the Refrigerant Gas Leak Detector beep continuously after it is turned on? Can it be turned off?
After the leak detector is turned on, it will beep slowly and continuously, which proves that it is operating normally and this sound cannot be turned off. When it detects a refrigerant gas leak, it will make a rapid beep.
The detector didn't detect a leak, what should I do?
When a leak can't be found, adjust to the higher sensitivity. Be aware that in windy areas, even a large leak is difficult to be found. In this condition, it is better to shield the potential leak area.
How can I know if the battery voltage is normal?
The forepart light of panel indicates the leak and the battery voltage. Green- Battery voltage is normal, sufficient for proper operation. Red-Battery voltage is approaching the lower thre shold for operation, replace as soon as possible.
How can the detector avoid false alarms?
WJL-6000 has automatic-circuit function. when in the measu ring state, automatic circuit will follow the halogen gas conce ntration changes in the environment and is able to avoid false alarms. Another option toavoid the false alarms is to move the device to open-air environment. Then please restart the device and adjust sensitivity to maximum level.
Notices
- Do not submerge the product in water.
- Do not expose the product to temperatures exceeding 60°C.
- Do not leave the product in direct sunlight for long periods of time.
- Do not dismantle or attempt repairs of the product without authorisation.
- Remove the batteries when not used for extended periods of time.
- Keep the sensing tip clean from dust, moisture and grease.
- If dirty, clean the tip by immersing in mild solvent such as alcohol for several seconds then using compressed air or a towel to dry.
- Do not use solvents such as gasoline, turpentine minerals etc to clean the product.
- Turn the tool off before replacing the sensing tip to avoid mild electric shock.