SHURE VP88 Stereo Condenser Microphone Instruction Manual

June 14, 2024
Shure

VP88
Stereo Condenser Microphone

Online user guide VP88 stereo condenser microphone.
Version: 2.2 (2022-J)

General Description

The Shure Model VP88 is a stereo microphone equally effective in studio broadcasting applications as in the field for electronic news gathering (ENGL).
This stereo microphone combines two condenser cartridges in a single housing, in a mid-side (M-S) microphone cartridge configuration. One cartridge (Mid) faces forward to capture on-xis sound in a cardioid pattern. The other cartridge (Side) is bi-directional, capturing sound from either side.
Containing three settings for different degrees of stereo image separation, the VP88 contains an internal M-S matrix that can be bypassed if an external matrix is used, or if stereo imaging is done in post-production. External switches  control output mode, stereo imaging, low-frequency roll off settings, and battery on/off.
When the VP88 is set for stereo mode operation (H, M, or L), the left and right signals should remain fully separated and kept at equal levels to maintain a balanced stereo effect.

Features

  • Time-coherent, Mid-Side (M-S) design for optimal stereo imaging
  • Built-in stereo matrix for direct control of the stereo spread; direct M-S outputs provided 40 to 20,000 Hz frequency response
  • Low noise and distortion, wide dynamic range
  • Switch-selectable, low-frequency roll-off (12 dB/octave below 80 Hz) for reduced pickup of ambient noise and stand vibration
  • Phantom power or 6V camera battery with LED power indicator
  • Internal shock mount for reduced stand vibration and handling noise
  • Impact resistant, durable construction
  • Integrated heavy-duty “pop” screen
  • Windscreen, swivel mount adapter, and Y-cable included

Mounting

The VP88 can be mounted on a standard microphone floor stand, fishpole or boom. Make sure the front of the grille faces the sound source and the top of the microphone faces up, so that the resulting stereo image matches the left and  right components of the sound source.

Power

Phantom Power The VP88 can operate on an internal 6V battery or phantom power from any microphone mixer or console providing 9 to 52 Vdc, or by a phantom power supply such as the Shure PS1A. Each balanced audio cable pair (pins 2 and 3: Mid/Left; pins 4 and 5: Side/Right) carries the supply current to the microphone, and the cable shield (pin 1) is the ground return.
The Mid or Side output can be used individually with either phantom or battery power. When operating in the Stereo mode without battery, both Mid/Left and Side/Right outputs must be phantom powered.
Battery Power
If phantom power is not available, move the Battery switch to the Batt On position. The adjacent LED will flash indicating at least five hours of useful battery life, and if no flashing is observed the battery should be replaced. The battery  does not drain when phantom power is applied.
Installing and Replacing the Battery
The VP88 uses a 6V cylindrical battery commonly used in cameras. Average battery life depends on the type of battery: typically 70 hours for silver oxide/lithium and 40 hours for alkaline.

SPEC. AGENCY/MANUFACTURER| SILVER OXIDE| LITHIUM| MANGANESE ALKALINE
---|---|---|---
NEDA| 1406SOP| 500SL| 1414A
IEC| 4SR44| 2CR1/3N| 4LR44
Duracell| PX28| PX28L|
Eveready| 544| L544| A544
Kodak| KS28| |
Panasonic| 4G13| | 4LR44
Radio Shack| | | 26-469
Varta| V28PX| V28PXL| V4304PX

To install or replace the battery, proceed as follows:

  1. Disconnect the microphone cable and unscrew the VP88 lower handle.
  2. Carefully slide the lower handle away from the grille, exposing the battery compartment. If necessary, remove the old battery.
  3. Insert the new battery, observing the polarity marking in the battery compartment.
  4. Slide the lower handle back into position and tighten.

Connections
Use the supplied Y-splitter cable to connect the VP88 to two inputs of a mixer or console. The red connector, marked “M” and  “L”, carries the Mid signal (in MS mode) or left signal (in stereo mode). The green connector, marked “S” and “R”, carries the Side signal (in MS mode) or right signal (in stereo mode). For stereo mode operation, connect the left (L) splitter connector to the Channel 1 input and the right (R) splitter connector to the Channel 2 input of the mixer or  console. Set the Channel 1 pan pot to full left and the Channel 2 pan pot to full right.
Use the Shure C110 Extension Cable (available as an accessory) for extended cable runs between the VP88 and a mixer or console.

Using an Additional Microphone
A second (mono) microphone can be used for interviewing or close miking. Turn its channel pan pot to the center position and set its level independently.
Monitoring
To check the balance for the mono listener, monitor sound in mono mode as well as stereo. Since the side signal is cancelled in mono, the mono output will be equal to the cardioid Mid cartridge signal only, regardless of the side level control setting.
Minimizing Wind and Breath Noise
The integrated pop filter provides reduction of breath and wind sound. Use the removable foam windscreen for high intensity wind and speaking conditions.
Low-Frequency Rolloff
A low-frequency rolloff (12 dB per octave cut below 80 Hz) rolloff reduces pickup of low-frequency noise and vibration. Set the upper control switch on the VP88 to either of the two low-frequency rolloff positions, depending on whether  phantom or battery power is being used.

  SHURE VP88 Stereo Condenser Microphone - Rolloff

Output Mode
The lower control sets the VP88 to either MS Mode, or one of three Stereo modes. (L, M, or H).

Stereo Output Mode

In Stereo Mode, the VP88 uses its internal matrix to mix the Mid and Side signals and provide Left and Right stereo outputs.
The three settings (H, M, and L), determine the strength or width of the stereo effect, as described below. Nominal Left and Right pickup patterns are shown in the following series.
The mono sum (Left + Right) in any Stereo position is always equal to the Mid signal, ensuring mono compatibility.
L (Low): Side level 6.0 dB lower than Mid level. The stereo image spread of the stereo images is small. Use this setting for distant miking, or in situations where the microphone directionality cannot be well controlled, such as hand- held  use. In the L position, the microphone also picks up the least amount of ambient sound from the side, and can be used to reduce high ambient noise or reverberation. The L setting can be useful if the area being miked is already very wide.
However, the degree of stereo effect may be compromised in narrow performing areas.
M (Medium): Side level is 1.9 dB lower than Mid level. The increased side ambience pickup and stereo spread make the M setting ideal for most applications.
H (High): Side level is1.6 dB higher than Mid level. The H position provides the most side ambience pickup and the greatest amount of stereo spread. This setting is only appropriate if a high degree of ambience pickup is acceptable and  the performing area is not excessively wide.
MS Output Mode: In MS mode, the VP88’s internal stereo matrix is bypassed. The signal from the mid cartridge is sent to the red connector on the Y-plitter cable (M) and the side cartridge output is sent to the green connector (S). The  Side on-axis sensitivity (90° from the front axis of the microphone) is 1.6 dB higher than the on-axis sensitivity of the Mid output. The sensitivities of the Mid and Side outputs are equal at 45° off the front axis of the microphone.
The polarity of the left lobe of the Side output matches the polarity of the Mid output.
The right lobe of the Side output is opposite polarity.

|
---|---
|

External Matrixes

When using an external stereo matrix, such as a matrix transformer or active matrix circuitry, set the VP88 to MS mode. The Mid and Side outputs can be processed through a sum-and- ifference matrix to produce Left and Right stereo signals as follows:
Left = Mid + Side
Right = Mid – Side
An 1:1 ratio of Mid to Side produces stereo signals identical to those obtained with Stereo Output switch set to High (H). Results similar to the Medium (M) and Low (L) settings can be obtained by attenuating the side signal before matrixing.

Specifications

Type
Single-point stereo (MS configuration) condenser
Polar Pattern

Mid Cartridge Cardioid
Side Cartridge Bidirectional

Frequency Response
40 to 20,000 Hz
Output Impedance
EIA rated at 150 Ω (100 Ωactual)
Sensitivity
open circuit voltage, @ 1 kHz, MS Mode
-66 dB[1] (0.5 mV)
Maximum SPL

800 Ω load 129 dB
150 Ω load 119 dB

Signal-to-Noise Ratio[3] 70 dB
Dynamic Range
105 dBMaximum SPL, A-weighted
Clipping Level
@ 1 kHz, 1% THD

800 Ω load Mid Cartridge -12 dBV (0.25 V)
Side Cartridge -10 dBV (0.30 V)
150 Ω load Mid Cartridge -25 dBV (0.06 V)
Side Cartridge -19 dBV (0.11 V)

Self Noise
equivalent SPL
24 dBA-weighted, 28 dBtypical
Hum Pickup
-4  dB equivalent SPL in a 1millioersted field (60 XXXXXXXXXXXX )
Operating Temperature Range
-18°C (0°F) to 57°C (135°F)
Storage Temperature Range
-29°C (-20°F) to 74°C (165°F)
Operating Relative Humidity
0 to 90%
Polarity
Positive pressure applied from any direction to the Mid cartridge or from the left to the Side cartridge in the MS mode, or applied from the front in the Stereo mode produces positive voltage on pin 2 relative to pin 3 (Mid/Left) and pin 4  relative to pin 5 (Side/Right).
Housing
Brass and nickel-plated aluminum construction with stainless steel grille. Finished in satin black vinyl enamel
Power Requirements
9–52 V DC[4] phantom power (IEC-61938) , 1.3 mAoutput, 2.6 mAtotal

Battery

Type 6 Vcylindrical
Life 70 hours
Current Drain 2.4 mAtotal

Overvoltage Protection
Maximum External Voltage applied to Pins 2 through 5 with respect to Pin 1: ± 75 Vdc Net Weight
417 g ( 14.7 oz.)
[1] 1 Pa=94 dB SPL
[3]S/N ratio is the difference between 94 dB SPL and equivalent SPL of self noise, A-weighted
[4]All specifications measured with a 48 Vdc phantom power supply. The microphone operates at lower voltages, but with slightly decreased headroom and sensitivity.

Frequency Response and Polar Patterns

SHURE VP88 Stereo Condenser Microphone - Patterns| SHURE VP88 Stereo Condenser Microphone - Patterns 2
---|---
SHURE VP88 Stereo Condenser Microphone - Patterns 3| SHURE VP88 Stereo Condenser Microphone - Patterns
4
SHURE VP88 Stereo Condenser Microphone - Connections

SHURE VP88 Stereo Condenser Microphone - Connections
2

Accessories

Furnished Accessories

Battery 80A463
Zipper Bag 95B2313
Foam Windscreen 49A91
Swivel Stand Adapter 90G4046
0.76 m (30 in) Y-Splitter Cable 95A2300

Optional Accessories

Control Knob 65B1218B

Telescoping Tripod Microphone Floor Stand up to 14 ft (4.3 m) with carrying case| S15A

Certifications

Certifications
Note: Testing is based on the use of supplied and recommended cable types. The use of other than shielded (screened) cable types may degrade EMC performance.
The CE Declaration of Conformity can be obtained from: www.shure.com/europe/compliance Authorized European representative:

Shure Europe GmbH
Headquarters Europe, Middle East & Africa
Department: EMEA Approval
Jakob-Dieffenbacher-Str. 12
75031 Eppingen, Germany
Phone: +49-7262-92 49 0
Fax: +49-7262-92 49 11 4
Email: [email protected]

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Shure User Manuals

Related Manuals