IP and PoE+ over Coax Solution
Models Include:
eBridge400PCRM
– Four (4) Channel Receiver
eBridge800PCRM
– Eight (8) Channel Receiver
eBridge1600PCRM
– Sixteen (16) Channel Receiver
Installation Guide
Rev. 072914
Installing Company: ____
Service Rep. Name:
Address: ____
Phone #: __
Overview:
Altronix eBridge400/800/1600PCRM and eBridge100TM/eBridge100ST are CAT5e to
Coax cable Ethernet adapters/Media converters that deliver data and power over
the coax cable in a PoE+ compliant format. The paired set enables fast
100Base-T Full Duplex Ethernet digital communication to be transmitted over
Coax cable. The eBridge400/800/1600PCRM receivers are powered by any UL
Listed, PoE midspan or endspans and pass power over the coax to the
eBridge100TM/eBridge100ST hardened transceivers. This enables the
eBridge400/800/1600PCRM to be used in a managed manner, allowing for remote
camera reset. The eBridge100TM/eBridge100ST, in turn, passes PoE+ compliant
power to a PoE-enabled camera or IP device. These plug-and-play units
facilitate system upgrades from analog to IP cameras/devices utilizing
existing legacy Coax and eliminating the costs and labor associated with
installing new network cabling. In addition, data transmission and power over
the Coax is possible up to 300m in comparison to 100m Ethernet maximum
distance (see Maximum Length of Coax Type vs. Camera Power/PoE Class, pg. 6).
Agency Listings:
- UL 60950-1 Information Technology Equipment.
- CE
European Conformity.
-
C-Tick C-Tick compliant.
Compatible Transceivers: -
eBridge100TM: Hardened transceiver.
-
eBridge100ST: Hardened mini transceiver.
Input:
- Powered by a UL Listed limited power source, PoE midspan or endspan.
Ethernet:
- Connectivity: RJ45, auto-crossover.
- Wire type: 4-pair CAT5e or better-structured cable.
- Distance: up to 100m.
- Speed: 100BaseT, 100Mbps full duplex, auto negotiation.
PoE is compliant with IEEE 802.3af (15W) and PoE+ compliant with IEEE 802.3at
(30W).
Delivered to the camera by eBridge100TM/eBridge100ST.
Power provided by eBridge400/800/1600PCRM to eBridge100TM/eBridge100ST by PoE
protocol.
Coax:
- Distance: up to 300m (see Maximum Length of Coax Type vs. Camera Power/PoE Class, pg. 6) for power delivery of coax.
- Throughput is rated to pass 100Mbps of data at distances up to 300m full duplex. With proper headend equipment, this supports Megapixel, HD720, HD1080.
- Connectivity: BNC, RG-59/U or similar.
LED Indicators:
-
eBridge400/800/1600PCRM:
Blue LED (near BNC) – Coax link connection.
Yellow and Green LED (RJ45) – IP Link status, 100Base-T/active. -
eBridge100TM:
Green – PoE ON (by respective RJ45 jack).
Yellow and Green LED (RJ45) – IP Link status, 100Base-T/active. -
eBridge100ST:
Green – PoE ON (by respective RJ45 jack).
Yellow and Green LED (RJ45) – IP Link status,
10/100Base-T/active.
Blue: Coax Link is active.
Environmental: -
Operating Temperature:
eBridge400/800/1600PCRM:
– 20ºC to 49ºC (– 4ºF to 120.2ºF).
eBridge100TM:
For 15W: – 40ºC to 75ºC (– 40ºF to 167ºF).
For 25W: – 40ºC to 70ºC (– 40ºF to 158ºF).
For 30W: – 40ºC to 49ºC (– 40ºF to 120.2ºF).
eBridge100ST:
For 15W: – 40ºC to 75ºC (– 40ºF to 167ºF).
For 30W: – 40ºC to 60ºC (– 40ºF to 140ºF). -
Storage Temperature:
– 30ºC to 70ºC (– 22ºF to 158ºF). -
Humidity: 20 to 85%, non-condensing.
Applications:
- Retrofit digital IP cameras in an analog CCTV installation.
- Works with Megapixel, HD720, HD1080 and VGA (SD) cameras (see note, pg. 3).
- Extend Network link distance in an industrial environment (see note, pg. 3).
- Upgrade deployed CCTV Coax to a digital network in Retail, Hospitality, Arenas, Casinos, Airports, Schools, Hospitals, Transportation, etc.
Mechanical:
- Dimensions (H x W x D approx.):
eBridge400PCRM:
1.7” x 5.25” x 9.25” (43.8mm x 133.4mm x 235mm).
eBridge800/1600PCRM:
1.625” x 19.125” x 8.5” (42mm x 486mm x 216mm).
eBridge100TM:
1” x 2.5” x 4.375” (25.4mm x 63.5mm x 111.1mm).
eBridge100ST:
2.27” x 2.645” x 1.12” (57.7mm x 67.2mm x 28.4mm).
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA
70/ANSI, and with all local codes and authorities having jurisdiction. Wiring
should be UL Listed and/or Recognized wire suitable for the application.
eBridge400/800/1600PCRM is not intended to be connected to outside plant leads
and should be installed indoors within the protected premises.
The eBridge400/800/1600PCRM and eBridge100TM/eBridge100ST are intended for
indoor use only.
Elevated Operating Ambient – If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient.
Therefore, consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature (Tma) specified by
the manufacturer.
Reduced Air
Flow – Installation of the equipment in a rack should be such that the amount
of airflow required for the safe operation of the equipment is not
compromised.
Do not obstruct any air vents on the unit. It is recommended to leave half
space above and below the unit.
Mechanical
Loading – Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
Caution: Once PoE connection is established between
eBridge400/800/1600PCRM and eBridge100TM or eBridge100ST, disconnecting the
coax from eBridge100TM will not disable the PoE-compliant voltage from
eBridge400/800/1600PCRM. eBridge100TM or eBridge100ST can be reconnected;
however, caution should be taken not to connect the coax wiring from
eBridge400/800/1600PCRM to any non-PoE device.
-
eBridge400/800/1600PCRM Receivers installation:
a. eBridge400PCRM – Affix rubber pads to eBridge400PCRM for shelf installation (Fig. 6, pg. 8).
eBridge800/1600PCRM – Attach mounting brackets to the unit for rack installation (Fig. 4, pg. 8).
Affix rubber pads to eBridge800/1600PCRM for shelf installation (Fig. 6, pg. 8).
The unit should be located in proximity to an ethernet switch/network, NVR or video server.
b. Connect the structured cable from the ethernet midspan or endspan device to the RJ45 jack marked [100BaseT] (Fig. 2, pg. 4).
c. Connect Coax cable to BNC connector marked [Coax] (Fig. 1, pg. 4). -
eBridge100TM Transceiver installation:
a. Secure the unit to the desired mounting surface with a proper fastening device utilizing the case’s mounting hole.
The unit should be mounted in proximity to the camera/device.
b. Connect the structured cable from the IP camera/device to the RJ45 jack marked [100BaseT] (Fig. 2, pg. 4).
c. Connect Coax cable to BNC connector marked [Coax] (Fig. 2, pg. 4). -
eBridge100ST Transceiver installation:
a. Secure the unit to the desired mounting surface with a proper fastening device utilizing the case’s mounting hole (Fig. 2a, pg. 4).
The unit should be mounted in proximity to the camera/device.
b. Connect the structured cable from the IP camera/device to the RJ45 jack marked [PoE Out] (Fig. 2a, pg. 4).
c. Connect Coax from eBridge receiver (eBridge400PCRM, eBridge800PCRM or eBridge1600PCRM) cable to BNC tether cable marked [Coax] (Fig. 2a, pg. 4).
Note: eBridge400/800/1600PCRM is designed to accommodate Megapixel, HD720, HD1080, and VGA (SD) cameras. It is important to note that some high resolution and high frame rate cameras may demand faster headend processing ability, such as a PC graphics card to present a quality image. If the headend processing equipment is insufficient in speed, the image may show pixelation and latency. It is advisable to pretest the system if unsure. Alternatively, frame rate and resolution may be reduced to accommodate system equipment.
Typical Application:
Technical Specifications:
Parameter
|
Description
---|---
Connections| BNC for Coax link. RJ45 for ethernet link.
Input power requirements| UL Listed power-limited midspan or endspan port
connected.
Indicators| eBridge400/800/1600PCRM:
Blue LED (near BNC): Coax link connection.
Yellow and Green LED (RJ45): IP Link status, 100Base-T/active.
eBridge100TM:
Green LED (by respective RJ45 jack): PoE ON.
Yellow and Green LED (RJ45): P Link status, 100Base-T/active.
eBridge100ST:
Green LED (by respective RJ45 jack): PoE ON.
Yellow and Green LED (RJ45): IP Link status, 10/100Base-T/active.
Blue LED: Coax Link is active.
Environmental Conditions| Operating Ambient Temperature (UL60950-1):
eBridge400/800/16
PCRM: – 20ºC to 49ºC (– 4ºF to 120.2ºF).
eBridge100TM:
For 15W: – 40ºC to 75ºC (– 40ºF to 167ºF).
For 25W: – 40ºC to 70ºC (– 40ºF to 158ºF).
For 30W: – 40ºC to 49ºC (– 40ºF to 120.2ºF).
eBridge100ST:
For 15W: – 40ºC to 75ºC (– 40ºF to 167ºF).
For 30W: – 40ºC to 60ºC (– 40ºF to 140ºF).
Relative humidity: 20 to 85%, non-condensing.
Storage Temperature: 30ºC to 70ºC (– 22ºF to 158ºF).
Operating Altitude: – 304.8 to 2,000m.
Regulatory Compliance| UL/cUL Listed for Information Technology Equipment (UL
60950-1). CE European Conformity. C-Tick compliant.
Weights (approx.)| eBridge400PCRM: Product: 1.35 lbs. (0.61 kg) | Shipping:
1.7 lbs. (0.77 kg).
eBridge800PCRM: Product: 5.8 lbs. (2.63 kg) | Shipping: 7.8 lbs. (3.54 kg).
eBridge1600PCRM: Product: 7.2 lbs. (3.27 kg) | Shipping: 9.2 lbs. (4.17 kg).
Maximum Length of Coax Type vs. Camera Power/PoE Class:
Camera Power/ PoE Class
| RG59/U (23AWG)| RG59/U (22AWG)| RG59/U (20AWG)| RG59/U (18AWG)| RG6/U
(18AWG)
---|---|---|---|---|---
Max. Length (meters)
13W/0| 261m| 300m| 300m| 300m| 300m
4W/1| 300m| 300m| 300m| 300m| 300m
6.5W/2| 300m| 300m| 300m| 300m| 300m
13W/3| 261m| 300m| 300m| 300m| 300m
19W| 261m| 300m| 300m| 300m| 300m
25W| 261m| 300m| 300m| 300m| 300m
eBridge400PCRM Enclosure Dimensions (H x W x D approximate): 1.7” x 5.25” x 9.25” (43.8mm x 133.4mm x 235mm)
eBridge800PCRM and eBridge1600PCRM
Enclosure Dimensions (H x W x D approximate): 1.625” x 19.125” x 8.5” (42mm x
486mm x 216mm) eBridge1600PCRM shown. eBridge800PCRM is similar.
Mounting Options:
Rack Mount Installation (eBridge800PCRM and eBridge1600PCRM):
- Remove and discard factory-installed screws from both sides of the rack chassis (Fig. 4a).
- Install mounting brackets (A) on the left and right side of the rack chassis using the four (4) flat head screws (B) (included) (Fig. 4b).
- Place unit into desired EIA 19” rack position and secure it with mounting screws (not included) (Fig. 4c).
Wall Mount Installation (eBridge800PCRM and eBridge1600PCRM):
- Install mounting brackets (A) on the left and right side of the rack chassis using four (4) flat head screws (B) (included) (Fig. 5a).
- Place the unit at the desired location and secure with #6 size screws or larger (not included) (Fig. 5b).
Caution: It is necessary to make sure mounting screws are securely fastened to a beam when installing the unit vertically.
Dotted lines indicate studs behind sheetrock.
Shelf Installation (eBridge400PCRM, eBridge800PCRM and eBridge1600PCRM):
- Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 6).
- Place the unit in the desired location.
Mounting Hardware (Included):
A Two (2) mounting brackets(except eBridge400PCRM)
B Six (6) flat head screws for mounting brackets.(except eBridge400PCRM)
C Four (4) rubber pads. Altronix is not responsible for any typographical