NXP UM11385 Evaluation Board User Manual
- June 4, 2024
- NXP
Table of Contents
NXP UM11385 Evaluation Board
Document information
Information | Content |
---|---|
Keywords | P3A9606JK, Level Shifter, Level Translator, P3A9606JK-EVB evaluation |
board
Abstract| The P3A9606JK is a 2-bit, dual supply translating transceiver with
auto direction sensing that enables bidirectional voltage level translation.
This user manual describes the setup, configuration and operation of the
P3A9606JK- EVB evaluation board.
Revision history
Rev | Date | Description |
---|---|---|
v.1.0 | 20210621 | Initial version |
Important notice
NXP provides the enclosed product(s) under the following conditions:
This evaluation kit is intended for use of ENGINEERING DEVELOPMENT OR
EVALUATION PURPOSES ONLY. It is provided as a sample IC pre-soldered to a
printed circuit board to make it easier to access inputs, outputs, and supply
terminals. This evaluation board may be used with any development system or
other source of I/O signals by simply connecting it to the host MCU or
computer board via off-the-shelf cables. This evaluation board is not a
Reference Design and is not intended to represent a final design
recommendation for any particular application. Final device in an application
will be heavily dependent on proper printed circuit board layout and heat
sinking design as well as attention to supply filtering, transient
suppression, and I/O signal quality. The goods provided may not be complete in
terms of required design, marketing, and or manufacturing related protective
considerations, including product safety measures typically found in the end
product incorporating the goods. Due to the open construction of the product,
it is the user’s responsibility to take any and all appropriate precautions
with regard to electrostatic discharge. In order to minimize risks associated
with the customers applications, adequate design and operating safeguards must
be provided by the customer to minimize inherent or procedural hazards. For
any safety concerns, contact NXP sales and technical support services.
Introduction
The P3A9606JK is a 2-bit, dual supply translating transceiver with auto direction sensing that enables bidirectional voltage level translation. It features two 1-bit input-output ports (An and Bn), one output enable input (OE) and two supply pins (VCC(A) and VCC(B)). VCC(A) can be supplied at any voltage between 0.7 V and 1.98 V and VCC(B) can be supplied at any voltage between 0.7 V and 1.98 V, making the device suitable for translating between any of the low voltage nodes (0.8 V, 1.2 V and 1.8 V). VCC(A) must be ≤ VCC(B) for minimum current consumption. P3A9606JK can be used for both Open Drain as well as push-pull application which allows for level translation applications using SPMI, I2C and SPI protocols (see datasheet application section). This document is intended to help the users to quickly setup, configure and operate the P3A9606JK-EVB evaluation board in the users’ hardware platform.
Finding kit resources and information on the NXP website
NXP Semiconductors provides online resources for this evaluation board and its
supported device(s) on http://www.nxp.com.
The information page for the P3A9606JK-EVB evaluation board is at
https://www.nxp.com/P3A9606JK-EVB.
Collaborate in the NXP community
The NXP community is for sharing ideas and tips, ask and answer technical
questions, and receive input on just about any embedded design topic.
The NXP community is at http://community.nxp.com
Getting to know the hardware
Kit overview
P3A9606JK can be used as a stand-alone level shifter when a CERES is not available for evaluation and testing. The user can manually connect the signals to be shifted to port A1/A0 and B1/B0 of the P3A9606JK. External VCCA/VCCB can be manually selected and connected to the evaluation board. As default, P3A9606JK-EVB evaluation board is configured (with jumper settings) to be mated to a CERES motherboard serial expansion bus as a level shifter on the SPMI bus. If needed, P3A9606JK-EVB evaluation board can be bypassed using jumper settings to remove it from the SPMI bus. The evaluation boards are shipped with a P3A9606JK soldered on as U1; a socket (U2 on the schematic) can be used in place of U1 to allow the user the flexibility of repeatedly replacing P3A9606JK multiple times. U1 and U2 share the same PCB footprint, therefore, U1 must be removed first before U2 as a socket can be installed.
Connectors and jumpers
Please refer to Figure 1 to find the location of connectors and jumpers on the evaluation board.
Default jumper settings (CERES motherboard SPMI bus option)
.As default, the P3A9606JK-EVB evaluation board is configured to be mated to a CERES motherboard serial expansion bus as a level shifter on the SPMI bus as shown in Table 1.
Table 1. Default jumper settings
Header | Jumper on | Comment |
---|---|---|
J8 | 2-3 | Select P3A9606JK port A1 |
J9 | 2-3 | Select P3A9606JK port B1 |
J14 | 2-3 | Select P3A9606JK port A2 |
J15 | 2-3 | Select P3A9606JK port B2 |
J12 | 1-3 | OE is connected to VCCA |
Header | Jumper on | Comment |
--- | --- | --- |
JP2 | Open | VCCA is supplied from external, J20 |
JP1 | Open | VCCB is supplied from external, J22 |
J7 | Open | Not used, CERES motherboard is on port A1 |
J10 | Open | Not used, CERES motherboard is on port B1 |
J13 | Open | Not used, CERES motherboard is on port B1 |
J11 | Open | Not used, CERES motherboard is on port B2 |
Non-CERES motherboard jumper settings
P3A9606JK can be used as a stand-alone level shifter when a CERES is not available for evaluation and testing. The user can manually connect the signals to be shifted to port A1/A2 and B1/B2 of the P3A9606JK through jumpers J7, J13, J10, J11 as shown in Table 2.
Table 2. Non-CERES motherboard jumper settings
Header | Jumper on | Comment |
---|---|---|
J8 | 2-3 | Select P3A9606JK port A1 |
J9 | 2-3 | Select P3A9606JK port B1 |
J14 | 2-3 | Select P3A9606JK port A2 |
J15 | 2-3 | Select P3A9606JK port B2 |
J12 | 1-3 | OE is connected to VCCA |
JP2 | Open | VCCA is supplied from external, J20 |
JP1 | Open | VCCB is supplied from external, J22 |
J7 | 1-2 | Port A1 of signal to be shifted |
J10 | 1-2 | Port B1 of signal to be shifted |
J13 | 1-2 | Port A2 of signal to be shifted |
J11 | 1-2 | Port B2 of signal to be shifted |
P3A9606JK bypass
P3A9606JK can be electrically removed and bypassed from the bus at any time, such as during debugging a level shifting issue. Once bypassed using the jumper settings from Table 3, signal on A1 is directly connected to B1 and signal on A2 is directly connected to
Table 3. Bypass jumper settings
Header | Jumper on | Comment |
---|---|---|
J8 | 1-2 | Select P3A9606JK port A1 |
J9 | 1-2 | Select P3A9606JK port B1 |
J14 | 1-2 | Select P3A9606JK port A2 |
J15 | 1-2 | Select P3A9606JK port B2 |
Test points
There are a number of test points to allow the user to monitor and observe signals coming in and out of P3A9606JK.
Table 4. Test points
Signal | Test point | Alternative test point |
---|---|---|
A1 | J4 | J1 pin 4 |
A2 | J13 | J1 pin 2 |
B1 | J10 | J2 pin 4 |
B2 | J11 | J2 pin 2 |
Errata list
Table 5. Errata list
Date| Errata Description| Impact to evaluation board|
Solution
---|---|---|---
–| None| None| None
Legal information
Definitions
Draft — A draft status on a document indicates that the content is still
under internal review and subject to formal approval, which may result
in modifications or additions. NXP Semiconductors does not give any
representations or warranties as to the accuracy or completeness of
information included in a draft version of a document and shall have no
liability for the consequences of use of such information.
Disclaimers
Limited warranty and liability — Information in this document is believed
to be accurate and reliable. However, NXP Semiconductors does not
give any representations or warranties, expressed or implied, as to the
accuracy or completeness of such information and shall have no liability
for the consequences of use of such information. NXP Semiconductors takes no
responsibility for the content in this document if provided by an information
source outside of NXP Semiconductors. In no event shall NXP Semiconductors be
liable for any indirect, incidental, punitive, special or consequential
damages (including – without limitation – lost profits, lost savings, business
interruption, costs related to the removal or replacement of any products or
rework charges) whether or not such damages are based on tort (including
negligence), warranty, breach of contract or any other legal theory.
Notwithstanding any damages that customer might incur for any reason
whatsoever, NXP Semiconductors’ aggregate and cumulative liability towards
customer for the products described herein shall be limited in accordance with
the Terms and conditions of commercial sale of NXP Semiconductors.
Right to make changes — NXP Semiconductors reserves the right to make
changes to information published in this document, including without
limitation specifications and product descriptions, at any time and without
notice. This document supersedes and replaces all information supplied prior
to the publication hereof.
Suitability for use — NXP Semiconductors products are not designed,
authorized or warranted to be suitable for use in life support, life-critical
or safety-critical systems or equipment, nor in applications where failure or
malfunction of an NXP Semiconductors product can reasonably be expected to
result in personal injury, death or severe property or environmental damage.
NXP Semiconductors and its suppliers accept no liability for inclusion and/or
use of NXP Semiconductors products in such equipment or applications and
therefore such inclusion and/or use is at the customer’s own risk.
Applications — Applications that are described herein for any of these
products are for illustrative purposes only. NXP Semiconductors makes no
representation or warranty that such applications will be suitable for the
specified use without further testing or modification. Customers are
responsible for the design and operation of their applications and products
using NXP Semiconductors products, and NXP Semiconductors accepts no liability
for any assistance with applications or customer product design. It is
customer’s sole responsibility to determine whether the NXP Semiconductors
product is suitable and fit for the customer’s applications and products
planned, as well as for the planned application and use of customer’s third
party customer(s). Customers should provide appropriate design and operating
safeguards to minimize the risks associated with their applications and
products. NXP Semiconductors does not accept any liability related to any
default, damage, costs or problem which is based on any weakness or default in
the customer’s applications or products, or the application or use by
customer’s third party customer(s). Customer is responsible for doing all
necessary testing for the customer’s applications and products using NXP
Semiconductors products in order to avoid a default of the applications and
the products or of the application or use by customer’s third party
customer(s). NXP does not accept any liability in this respect.
Export control — This document as well as the item(s) described herein
may be subject to export control regulations. Export might require a prior
authorization from competent authorities.
Evaluation products — This product is provided on an “as is” and “with
all faults” basis for evaluation purposes only. NXP Semiconductors, its
affiliates and their suppliers expressly disclaim all warranties, whether
express, implied or statutory, including but not limited to the implied
warranties of non-infringement, merchantability and fitness for a particular
purpose. The entire risk as to the quality, or arising out of the use or
performance, of this product remains with customer. In no event shall NXP
Semiconductors, its affiliates or their suppliers be liable to customer for
any special, indirect, consequential, punitive or incidental damages
(including without limitation damages for loss of business, business
interruption, loss of use, loss of data or information, and the like) arising
out the use of or inability to use the product, whether or not based on tort
(including negligence), strict liability, breach of contract, breach of
warranty or any other theory, even if advised of the possibility of such
damages. Notwithstanding any damages that customer might incur for any reason
whatsoever (including without limitation, all damages referenced above and all
direct or general damages), the entire liability of NXP Semiconductors, its
affiliates and their suppliers and customer’s exclusive remedy for all of the
foregoing shall be limited to actual damages incurred by customer based on
reasonable reliance up to the greater of the amount actually paid by customer
for the product or five dollars (US$5.00). The foregoing limitations,
exclusions and disclaimers shall apply to the maximum extent permitted by
applicable law, even if any remedy fails of its essential purpose.
Translations — A non-English (translated) version of a document is for
reference only. The English version shall prevail in case of any discrepancy
between the translated and English versions.
Security — The customer understands that all NXP products may be subject
to unidentified or documented vulnerabilities. Customer is responsible
for the design and operation of its applications and products throughout their
lifecycles to reduce the effect of these vulnerabilities on customer’s
applications and products. Customer’s responsibility also extends to other
open and/or proprietary technologies supported by NXP products for use
in customer’s applications. NXP accepts no liability for any vulnerability.
Customer should regularly check security updates from NXP and follow up
appropriately. Customer shall select products with security features that best
meet rules, regulations, and standards of the intended application and make
the ultimate design decisions regarding its products and is solely responsible
for compliance with all legal, regulatory, and security related requirements
concerning its products, regardless of any information or support that may be
provided by NXP. NXP has a Product Security Incident Response Team (PSIRT)
(reachable at PSIRT@nxp.com) that manages the investigation, reporting, and
solution release to security vulnerabilities of NXP products.
Trademarks
Notice: All referenced brands, product names, service names and
trademarks are the property of their respective owners.
NXP — wordmark and logo are trademarks of NXP B.V.
Tables
- Tab. 1. Default jumper settings………………………………….. 5
- Tab. 2. Non-CERES motherboard jumper settings……. 6
- Tab. 3. Bypass jumper settings………………………………….. 6
Figures
- Fig. 1. Location of connectors and jumpers……………… 5
- Tab. 4. Test points………………………………………………………. 7
- Tab. 5. Errata list………………………………………………………… 7
Please be aware that important notices concerning this document and the product(s) described herein, have been included in section ‘Legal information.
© NXP B.V. 2021. All rights reserved.
- For more information, please visit:http://www.nxp.com
- For sales office addresses, please send an email to:salesaddresses@nxp.com
- Date of release: 21 June 2020
- Document identifier: UM11385
Documents / Resources
| NXP
UM11385 Evaluation
Board
[pdf] User Manual
UM11385 Evaluation Board, UM11385, Evaluation Board, Board
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>