H3C GW-CRPS800 800W redundant power server power supply User Manual
- June 4, 2024
- H3C
Table of Contents
H3C GW-CRPS800 800W redundant power server power supply
Copyright © 2021, New H3C Technologies Co., Ltd. and its licensors
All rights reserved
No part of this manual may be reproduced or transmitted in any form or by any
means without prior written consent of New H3C Technologies Co., Ltd.
Trademarks
Except for the trademarks of New H3C Technologies Co., Ltd., any trademarks that may be mentioned in this document are the property of their respective owners.
Notice
The information in this document is subject to change without notice. All
contents in this document, including statements, information, and
recommendations, are believed to be accurate, but they are presented without
warranty of any kind, express or implied. H3C shall not be liable for
technical or editorial errors or omissions contained herein.
Environmental protection
This product has been designed to comply with the environmental protection requirements. The storage, use, and disposal of this product must meet the applicable national laws and regulations.
About the GW-CRPS800B power supply
IMPORTANT:
- The information in this document might differ from your product if it contains custom configuration options or features.
- The figures in this document are for illustration only.
- The model name of a hardware option in this document might differ slightly from its model name label. A model name label might add a prefix or suffix to the hardware-coded model name. For example, the GW-CRPS800B power supply model represents power supply labels including GW-CRPS800B-M, which has a different suffix.
The GW-CRPS800B is an AC input or high-voltage DC input and DC output power supply. It provides a maximum rated output of 800 W.
OVERVIEW
- LED
- Latch
- Power receptacle
- Handle
Key features
Protection
The power supply provides protection against input overcurrent, input undervoltage, output overvoltage, output overcurrent, output short circuit, and overtemperature conditions.
Redundancy
Multiple power supplies can be connected in parallel to achieve N+1 or N+N redundancy and load balancing.
Hot swapping
You can install or remove a power supply when the device is operating.
Tool-free replacement
You can replace a power supply without using tools.
Technical specifications
Item | Specifications |
---|---|
Model | GW-CRPS800B |
Rated input voltage range | · 100 VAC to 240 VAC @ 800 W |
· 192 VDC to 288 VDC (240 HVDC power source) @ 800 W
Maximum rated input current| · 10 A @ 100 VAC to 240 VAC
· 5 A @ 240 VDC
Maximum rated output power| 800 W
Efficiency at 50 % load| 80 Plus Platinum
Temperature| · Operating: 0°C to 55°C (32°F to 131°F)
· Storage: –40°C to +70°C (–40°F to +158°F)
Operating humidity| 5% to 85%
Maximum altitude| 5000 m (16404.20 ft)
Redundancy| Yes
Cold backup| Yes
LEDs
LED status | Description |
---|---|
Steady green | The power supply is operating correctly. |
Flashing green (1 Hz) | Power is being input correctly but the system is not |
powered on.
Flashing green (0.33 Hz)| The power supply is in standby state and is not
outputting power.
Flashing green (2 Hz)| The power supply is updating its firmware.
Steady amber
| · The power supply is faulty.
· The power supply is not receiving power, but the other power supply is receiving power.
Flashing amber (1 Hz)| An alarm has occurred on the power supply.
Off
| The power supply is not receiving power. Either or both of the following conditions might exist:
· Power cord connection failure.
· Power source shutdown.
Installing and removing the power supply
For information about installing and removing the power supply, see the user guide for the device.