H3C 6W105 SecPath F1000-AI-X0 Firewall Series User Guide
- June 4, 2024
- H3C
Table of Contents
- Chassis views
- Tool list
- Installation accessories
- Airflow of the firewall
- Mounting the device on a workbench
- Mounting the device in a rack
- Connecting the grounding cable
- Installing interface modules
- Installing drives
- Installing power supplies
- Connecting power cords
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
H3C 6W105 SecPath F1000-AI-X0 Firewall
| This document is applicable to the F1000-AI-10,F1000-AI-20, F1000-AI-30,
F1000-AI-50, F1000-AI-60, F1000-AI-70, F1000-AI-80, and F1000-AI-90 models.
The installation procedure is similar for the firewalls. This guide installs
an F1000-AI-50.
---|---
Chassis views
F1000-AI-10 front panel.
- Management Ethernet port (1/MGMT)
- Bypass ports
- Combo interfaces
- LEDs
- Console port
- USB port
- Reset button
- 10GBASE-R fiber ports
- 10/100/1000BASE-T copper ports
- Management Ethernet port(0/MGMT)
- Drive slot
F1000-AI-20/F1000-AI-30/F1000-AI-50 front panel.
- Drive slot
- LEDs
- 10/100/1000BASE-T Copper ports
- 1000BASE-X fiber ports
- 10GBASE-R fiber ports
- Console port
- USB port
- Management Ethernet port(0/MGMT)
The F1000-AI-60, F1000-AI-70, F1000-AI-80, and F1000-AI-90 firewalls have similar front panels. The following shows the F1000-AI-90 front panel. For the differences between the firewalls, see the installation guide.
- Drive slot
- Management Ethernet port(1/MGMT)
- 10/100/1000BASE-T Copper ports
- 10GBASE-R fiber ports
- 1000BASE-X fiber ports
- LEDs
- Reset button
- Micro USB port
- USB port
- Console port
- Management Ethernet port(0/MGMT)
Tool list
|
- No installation tools are provided with the device. Prepare them yourself as required.
- Wear an ESD wrist strap before installation, and make sure the wrist strap makes good skin contact and is reliably grounded.
---|---
Installation accessories
Airflow of the firewall
|
- The F1000-AI-10 firewall provides front side-intake and rear side-exhaust airflow for heat dissipation.
- The F1000-AI-20, F1000-AI-30, F1000-AI-50, F1000-AI-60, F1000-AI-70, F1000-AI-80, and
F1000-AI-90 firewalls provide left side-intake and right side-exhaust airflow for heat dissipation. Make sure the air vents of the device are not blocked and the installation site has a good cooling system.
---|---
Airflow through the F1000-AI-10 firewall chassis
Airflow through the F1000-AI-20/F1000-AI-30/F1000-AI-50/F1000-AI 60/F1000-AI-70/ F1000-AI-80/F1000-AI-90 firewall chassis
Mounting the device on a workbench
| Make sure the workbench is stable and reliably grounded. Do not place heavy
objects on the device.
---|---
Attach the rubber feet to the four round holes in the chassis bottom. Place
the device with upside up on the workbench.
Mounting the device in a rack
|
- For adequate heat dissipation, ensure a minimum clearance of 80 mm (3.15 in) around the air inlet and outlet vents of the chassis and a distance of 1U (44.45 mm, or 1.75 in) between the chassis and other devices in the rack.
- To avoid bodily injury and device damage, use a minimum of two people to mount the device in a rack.
---|---
Rack-mounting the F1000-AI-10
-
Install cage nuts
Mark the cage nut installation positions on the rack posts by using a mounting bracket. -
Install the mounting brackets
-
Install the device in the rack
Rack-mounting the F1000-AI-20/F1000-AI-30/F1000-AI-50/F1000-AI 60/F1000-AI-70/ F1000-AI-80/F1000-AI-90 firewall
-
Install cage nuts
Mark the cage nut installation positions on the rack posts by using a mounting bracket. -
Install the mounting brackets and shoulder screws
-
Install the device in the rack
| Attach the rear mounting brackets to the rack with the wide flange inside
or outside the rack based on the distance between the front and rear rack
posts (rack depth).
---|---
Rack depth| Rear mounting brackets installation method
---|---
15.94 in to 22.40 in| With the wide flange inside the rack
9.72 in to 16.18 in| With the wide flange outside the rack
Attaching the rear mounting brackets with the wide flange inside the rack
Attaching the rear mounting brackets with the wide flange outside the rack
Connecting the grounding cable
| Correctly connecting the grounding cable is crucial to lightning protection
and EMI protection. To guarantee the grounding effect, use the grounding cable
provided with the device
---|---
Grounding the device mounted on a workbench
If a grounding strip is available, connect the grounding cable to the
grounding strip.
Grounding the device mounted in a rack
Connect the grounding cable to the grounding screw on the rack.
Installing interface modules
|
- Interface modules are not provided with the device. Prepare them yourself if required.
- Interface modules are not hot swappable.
- The installation method is similar for the interface modules. This section installs an NSQM1GP4FBA interface module.
- Keep the filler panel in the interface module slot if you are not to install an interface module in the slot.
---|---
Compatible slots for the interface modules
The following table describes the compatible slots for the interface modules.
Item | Device model| Slot number| Speed mode| Applicable
interface modules
---|---|---|---
F1000-AI-10| /| /| Not supported
F1000-AI-20/F1000- AI-30/F1000-AI-50| Slot 1 and Slot 2| Low speed|
- NSQM1GT4PFC
- NSQM1GP4FBA
F1000-AI-60| Slot 1| High speed| NS-NIM-TG6A
Slot 2| Low speed|
- NSQM1GT4PFC
- NSQM1GP4FBA
F1000-AI-70/F1000- AI-80/F1000-AI-90| Slot 1 and Slot 3| High speed| NS-NIM-
TG6A
Slot 2 and Slot 4| Low speed|
- NSQM1GT4PFC
- NSQM1GP4FBA
Removing the filler panel
Installing an interface module
Installing drives
|
- Drives are not provided with the device. Prepare them yourself if required.
- For the system to identify the drive, use the drive from H3C.
- The drive is not hot swappable.
- Wear an ESD wrist strap when you install or remove a drive to protect the disk from ESD damage.
- Hold the drive by its two edges. Do not touch the components on the drive. Do not squeeze, rock, or hit the drive.
- Install a filler panel in the empty drive slot to prevent dust and other objects from entering the device.
---|---
Installing a drive for an F1000-AI-10 firewall
Remove the filler panel from the drive slot.
Push the drive slowly into the slot along the guide rails.
Installing a drive for an F1000-AI-20/F1000-AI-30/F1000-AI-50/F1000-AI
60/F1000-AI-70/ F1000-AI-80/F1000-AI-90 firewall
Remove the filler panel from the drive slot.
Push the drive slowly into the slot along the guide rails.
Installing power supplies
|
- Before installing a power module, make sure the power is disconnected and the device is reliably grounded.
- Do not install AC and DC power modules on the same firewall.
- Only the F1000-AI-20,F1000-AI-30,F1000-AI-50,F1000-AI-60,F1000-AI 70,F1000-AI-80,and F1000-AI-90 firewalls support removable power supplies.
- The F1000-AI-20, F1000-AI-30, and F1000-AI-50 firewalls support the PSR150-A1 and PSR150-D1 power supplies. The power supply installation procedure is the same for these firewalls. The F1000-AI-50 firewall is used as an example.
- The F1000-AI-60, F1000-AI-70, F1000-AI-80, and F1000-AI-90 firewalls support the PSR250-12A1, PSR450-12AHD, and PSR450-12D power supplies. The power supply installation procedure is the same for these firewalls. The F1000-AI-90 firewall is used as an example.
---|---
Installing power supplies for an F1000-AI-20/F1000-AI-30/F1000-AI-50
firewall
Remove the filler panel from the target power supply slot.
Install the removed filler panel in the unused power supply slot.
Install an AC power supply
Install a DC power suppl
Installing power supplies for an
F1000-AI-60/F1000-AI-70/F1000-AI-80/F1000-AI-90 firewall
Install an AC power supply
Install a DC power supply
Connecting power cords
|
- Before connecting a power cord, make sure the power is disconnected and the device is reliably grounded.
- Only the F1000-AI-20,F1000-AI-30,F1000-AI-50,F1000-AI-60,F1000-AI-70,F1000-AI-80,and F1000-AI-90 firewalls support AC and DC power supply. The other firewall models support only AC power supply.
---|---
Connecting the power cord for an F1000-AI-10 firewall
Connecting the power cord for an F1000-AI-20/F1000-AI-30/F1000-AI
50/F1000-AI-60/ F1000-AI-70/F1000-AI-80/F1000-AI-90 firewall
Connecting the AC power cord for a PSR150-A1 power supply
Using a power cord retainer clip to secure the power
Using a cable tie to secure the power cord
Connect the DC power cord for a PSR150-D1 power supply
Connecting the AC power cord for a PSR250-12A1 power supply and the high-
voltage DC power cord for a PSR450-12AHD power supply
Connecting the DC power cord for a PSR450-12D power supply
Copyright © 2021 New H3C Technologies Co., Ltd.
The information in this document is subject to change without notice.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>