wiha 90-1.000 V Volt Detector Instruction Manual
- June 14, 2024
- wiha
Table of Contents
wiha 90-1,000 V Volt Detector
Operating instructions
VoltDetector 90-1000 V
This contactless voltage tester is used to test alternating electric fields.
It can detect voltages in insulated cables, e.g. spot cable breaks.
Safety instructions
- AC > 50 V
- DC > 120 V
Above these voltage limits: life-threatening electric shock if touched.
- The warranty is voided in the event of injury or damage to property caused due to non-compliance with these operating instructions. The manufacturer accepts no liability for consequential damage.
- Operational safety is no longer guaranteed if the voltage tester has been modified in any way. Do not disassemble.
- Test the device on a known voltage source before and after you use it.
- Avoid environments containing dust, vapors or flammable gas.
Proper use
- Voltage: 90 – 1000 V AC
- Frequency: 50/60 Hz
- Only trained technical staff may use the voltage tester.
- The voltage tester must not be used to verify that there is no live current.
- You may only use a two-pole voltage tester as per EN 61243-3 to verify that there is no live current.
- You must pass on the operating instructions as well if you give a voltage tester to a third party.
Operational control
- a Test tip
- b LED indicator
- c Ready-to-use indicator
- d Power on/off button
- e End cap
Indication
Fitting/replacing the battery
- Battery type: 2x 1.5 V AAA
Preparing the device
Check the voltage tester is safe and intact on a regular basis (e.g. examine
for damage to the housing or deformation).
Checking the voltage
Visual testing signal
Technical specifications
- Protection class IP67
- Temperature range -20 °C – +40 °C
- Relative humidity < 80% rF
- Dimensions (L x W x H) 150 x 28 x 28.5 mm
- Safety tested as per IEC 61010-1:2010
- Weight (without/with battery) 40 g / 50 g
Cleaning
- Switch off the voltage tester before cleaning.
- Clean voltage tester with a damp cloth
- do not use any scouring agents or solvents.
- Dry thoroughly before using again.
Disposal
- Dispose of the voltage tester as per the applicable statutory regulations.
- You must dispose of empty batteries properly and separately from the product.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>