wiha 12-1000V Voltage Detector Instructions

June 9, 2024
wiha

12-1000V Voltage Detector
Instructions
Operating instructions

12-1000V Voltage Detector

|
---|---

Safety Instructions

Type Volt Detector EX 12-1000 V
Identification **** II3G Ex ic op is IIC T4 Gc
Certificate No. EPS 19 ATEX 1 223 X
Standards EN IEC 60079-0:2018

EN 60079-11:2012
EN 60079-28:2015

Repairs are not permitted!
The following conditions must be observed for use in potentially explosive atmospheres:

  • Before use in potentially explosive atmospheres, check the function and integrity of the housing and whether the correct batteries have been inserted.
  • Operation only on insulated electrical systems / cable
  • Maximum rated voltage U = 400 V AC
  • Operation only with batteries PAIRDEER Type R03 (AAA)
  • Replace batteries only if there is no explosive atmosphere

VoltDetector EX 12-1000 V
This contactless voltage tester is used to test alternating electric fields.
It can detect voltages in insulated cables, e.g. spot cable breaks.

AC > 50 V
DC > 120 V

Above these voltage limits: life-threatening electric shock if touched.

  • The warranty is voided in the event of injury or damage to property caused due to non-compliance with these operating instructions. The manufacturer accepts no  liability for consequential damage.
  • Operational safety is no longer guaranteed if the voltage tester has been modified in any way. Do not disassemble.
  • Test the device on a known voltage source before and after you use it.
  • Certified as per the ATEX standard.

Proper use

Voltage: 12 – 1000 V AC
Frequency: 40- 500 Hz
  • Only trained technical staff may use the voltage tester.
  • The voltage tester must not be used to verify that there is no live current.
  • You may only use a two-pole voltage tester as per EN61243-3 to verify that there is no live current.
  • You must pass on the operating instructions as well if you give voltage tester to a third party.
  1. Operational control
    a Testing tip
    b LED indicator
    c Ready-to-use indicator
    d Power on/off button
    e Flashlight on/off switch
    f End cap
    g Torch

  2. Indication & automatic switch-off

  3. Fitting/replacing the battery
    Battery type: 2x 1.5 V AAA
    Low battery: the ready-to-use indicator
    LED flashes

  4. Preparing the device
    Check the voltage tester is safe and intact on a regular basis (e.g. examine for damage to the housing or deformation).
    Note: All LEDs light up briefly when device is switched on.

  5. Checking the voltage
    Visual and audible testing signal

  6. Indicator (reference only) Field force depends on:
    connected voltage
    Distance from power source

  7. Mute mode

Technical specifications

Protection class IP67
Temperature range -20 °C – +40 °C
Relative humidity < 80% rF
Dimensions (L x W x H) 150 x 28 x 28.5 mm
Safety tested as per EN 61010-1:2010
Weight (without / with battery) 40 g / 50 g

Cleaning

  • Switch off voltage tester before cleaning.
  • Clean voltage tester with a damp cloth – do not use any scouring or solvents.
  • Dry thoroughly before using again.

Disposal

  • Dispose of the voltage tester as per the applicable statutory regulations.
  • You must dispose of empty batteries properly and separately from the product.

| Warning: dangerous voltage, risk of electric shock and impact on the voltage tester’s electric safety.
---|---
| Important Observe the indications in the operating instructions.
| Uninterrupted double or reinforce insulation as per Category II EN 61140.
Protection against electric shock.
**| Complies with European specifications.
| United Kingdom Conformity Assessed
| Canadian Standards Association (NRTL/C)
| Complies with applicable Australian regulations.
| The voltage tester meets WEEE Directive (2012/19/EU).
CAT IV
1000 V| The voltage tester is used to measure the source in low-voltage installations (i.e. electrical measuring devices  and measurements on counters, overcurrent protection devices and load management devices).
**
| II3G Ex ic op is IIC T4 Gc

Wiha Werkzeuge GmbH
Obertalstraße 3–7
78136 Schonach/Germany
Tel. +49 77 22 959-0
Fax +49 77 22 959-160
[email protected]
www.wiha.com

References