FRICO PNF30 Heat Fan Panther Instruction Manual
- June 14, 2024
- FRICO
Table of Contents
**FRICO PNF30 Heat Fan Panther Instruction Manual
**
Dimension
Minimum mounting distance
Wall
Ceiling
Floor
-
Detach bracket from the unit
-
Mark and drill holes
-
Mount the bracket on the wall
-
Hang the unit on the bracket
-
Adjust the angle and fix it with the lower screws
-
Tighten all screws.
The fan heater must be supplemented with a FC control system.
Connection
PNF20
PNF2023
PNF30
PNF3023
Item| Type| Voltage| Minimal Cross| Nominal Cross
section
---|---|---|---|---
number section cable for
terminal block
| | [V]| [mm 2 ]| [mm 2 ]
334031| PNF20| 400V3N~| 10| 35
334032| PNF2023| 230V3~| 16| 35
334033| PNF30| 400V3N~| 16| 35
334035| PNF3023| 230V3~| 25| 70
PLR30
Control systems FC Frico control
The fan heater must be supplemented with a FC control system.
FCDF – FC Direct
FCBC05
FCSF – FC Smart
**FCBC05
FCLAP
FCPF – FC Pro
FCBC05
FCLAP
FCTXRF
FCBF – FC Building
FCCF
FCBC10**
FCLAP
Item number | Type | Name | Dimensions |
---|---|---|---|
74688 | FCDF | FC Direct | 89x89x26 mm (FCCF) |
74689 | FCSF | FC Smart | 89x89x26 mm (FCCF) |
74690 | FCPF | FC Pro | 89x89x26 mm (FCCF) |
74691 | FCBF | FC Building | 89x89x26 mm (FCCF) |
Accessories
**FCRTX
FCSC10
**
FCOTX
FCSC10
**FCLAP
FCSC10
**
teem
Dimensions
Type number
74699 | FCLAP | 89x89x26 mm | FCBC05/10/25 | |
---|---|---|---|---|
74718 | FCBC05 | 5 m | FCSC10/25 | |
74719 | FCBC10 | 10 m | ||
74720 | FCBC25 | 25 m | ||
74721 | FCSC10 | 10 m | ||
74722 | FCSC25 | 25 m | ||
74703 | FCTXRF | for FC Smart, FC Pro | 89x89x26 mm | FCTXRF |
FCBC05/10/25
FCSC10/25
**FCTXRF
**
Technical specifications
Panther FC 20 – 30 (IP44) Item| Type| Output| Airflow|
Sound| Sound| ∆t 3| Motor| Voltage|
Amperage| Weight
---|---|---|---|---|---|---|---|---|---|---
number steps power 1
pressure* 2
| | [kW]| [mS/h]| [dB(A)]| [dB(A)]| [°C]| [W]|
[V]| [A]| [kg]
334031| PNF20*| 0/10/20| 2250/2800| 78| 51/62| 27/21| 150| 400V3N~4|
29,5| 28
334032| PNF2023| 0/10/20| 2250/2800| 78| 51/62| 27/21| 150| 230V3~|
50,2| 29
334033| PNF30*| 0/10/20/30| 2250/2800| 78| 51/62| 32/40| 150| 400V3N~4|
43,9| 31
334035| PNF3023| 0/10/20/30| 2250/2800| 78| 51/62| 32/40| 150| 230V3~|
75,3| 33
Ecodesign Regulation (EU) 2015/1188
Type | PNF20 | PNF2023 | PNF30 | PNF3023 |
---|---|---|---|---|
Heat output | ||||
Nominal heat output [kW] | 20 | 20 | 30 | 30 |
Minimum heat output [kW] | 10 | 10 | 10 | 10 |
Maximum continous heat output [kW] | 20 | 20 | 30 | 30 |
Auxiliary electricity consumption | ||||
At nominal heat output [kW] | 0,004 | 0,004 | 0,004 | 0,004 |
At minimum heat output [kW] | 0,004 | 0,004 | 0,004 | 0,004 |
In standby mode [kW] | 0,0005 | 0,0005 | 0,0005 | 0,0005 |
Features | ||||
Fan assisted output | Yes | Yes | Yes | Yes |
Electronic room temperature control plus week timer | Yes | Yes | Yes | Yes |
Room temperature control, with open window detection | Yes | Yes | Yes | Yes |
Distance control option | Yes | Yes | Yes | Yes |
Adaptive start control | Yes | Yes | Yes | Yes |
For translation of the English texts used, see the respective language pages.
Internal wiring diagram Panther FC 20 kW 400V3N
Wiring diagrams for control system in the FC manual.
Internal wiring diagramPanther FC 30 kW 400V3N~
Wiring diagrams for control system in the FC manual.
Internal wiring diagram Panther FC 20-30 kW 230V3~
Wiring diagrams for control system in the FC manual.
-
Features
-
Fan assisted heat output
-
Electronic room temperature control plus
week timer
-
Room temperature control, with open
-
window detection
-
Distance control option
-
Adaptive start control