FRICO PNF30 Heat Fan Panther Instruction Manual

June 14, 2024
FRICO

**FRICO PNF30 Heat Fan Panther Instruction Manual

**

Dimension

Minimum mounting distance

Wall
Minimum mounting distance

Ceiling

Floor

  1. Detach bracket from the unit

  2. Mark and drill holes
    Mark and drill holes

  3. Mount the bracket on the wall

  4. Hang the unit on the bracket

  5. Adjust the angle and fix it with the lower screws

  6. Tighten all screws.

The fan heater must be supplemented with a FC control system.

Connection

Connection

PNF20
PNF2023
Instruction Construction

PNF30
PNF3023

Item| Type| Voltage| Minimal Cross| Nominal Cross section
---|---|---|---|---
number                                        section cable       for terminal block
| | [V]| [mm 2 ]| [mm 2 ]
334031| PNF20| 400V3N~| 10| 35
334032| PNF2023| 230V3~| 16| 35
334033| PNF30| 400V3N~| 16| 35
334035| PNF3023| 230V3~| 25| 70

PLR30

Control systems FC Frico control
The fan heater must be supplemented with a FC control system.

FCDF – FC Direct

FCBC05

FCSF – FC Smart

**FCBC05

FCLAP

FCPF – FC Pro

FCBC05

FCLAP

FCTXRF
 
FCBF – FC Building
FCCF

FCBC10**


FCLAP

Item number Type Name Dimensions
74688 FCDF FC Direct 89x89x26 mm (FCCF)
74689 FCSF FC Smart 89x89x26 mm (FCCF)
74690 FCPF FC Pro 89x89x26 mm (FCCF)
74691 FCBF FC Building 89x89x26 mm (FCCF)

Accessories

**FCRTX

FCSC10
**

FCOTX

FCSC10

**FCLAP

FCSC10
**

teem
Dimensions
Type number

74699 FCLAP   89x89x26 mm FCBC05/10/25
74718 FCBC05   5 m FCSC10/25
74719 FCBC10   10 m
74720 FCBC25   25 m
74721 FCSC10   10 m
74722 FCSC25   25 m
74703 FCTXRF for FC Smart, FC Pro 89x89x26 mm FCTXRF

FCBC05/10/25
FCSC10/25


**FCTXRF

**

Technical specifications

Panther FC 20 – 30 (IP44) Item| Type| Output| Airflow| Sound| Sound| ∆t 3| Motor| Voltage| Amperage| Weight
---|---|---|---|---|---|---|---|---|---|---
number                  steps                           power
1 pressure* 2
| |
[kW]| [mS/h]| [dB(A)]| [dB(A)]| [°C]| [W]| [V]| [A]| [kg]
334031|
PNF20*| 0/10/20| 2250/2800| 78| 51/62| 27/21| 150| 400V3N~4| 29,5| 28
334032|
PNF2023| 0/10/20| 2250/2800| 78| 51/62| 27/21| 150| 230V3~| 50,2| 29
334033|
PNF30*| 0/10/20/30| 2250/2800| 78| 51/62| 32/40| 150| 400V3N~4| 43,9| 31
334035| PNF3023| 0/10/20/30| 2250/2800| 78| 51/62| 32/40| 150| 230V3~| 75,3| 33

Ecodesign Regulation (EU) 2015/1188

Type PNF20 PNF2023 PNF30 PNF3023
Heat output
Nominal heat output [kW] 20 20 30 30
Minimum heat output [kW] 10 10 10 10
Maximum continous heat output [kW] 20 20 30 30
Auxiliary electricity consumption
At nominal heat output [kW] 0,004 0,004 0,004 0,004
At minimum heat output [kW] 0,004 0,004 0,004 0,004
In standby mode [kW] 0,0005 0,0005 0,0005 0,0005
Features
Fan assisted output Yes Yes Yes Yes
Electronic room temperature control plus week timer Yes Yes Yes Yes
Room temperature control, with open window detection Yes Yes Yes Yes
Distance control option Yes Yes Yes Yes
Adaptive start control Yes Yes Yes Yes

For translation of the English texts used, see the respective language pages.

Internal wiring diagram Panther FC 20 kW 400V3N
Internal wiring diagram
Wiring diagrams for control system in the FC manual.

Internal wiring diagramPanther FC 30 kW 400V3N~
Internal wiring diagram
Wiring diagrams for control system in the FC manual.

Internal wiring diagram Panther FC 20-30 kW 230V3~
Internal wiring diagram
Wiring diagrams for control system in the FC manual.

  • Features

  • Fan assisted heat output

  • Electronic room temperature control plus
    week timer

  • Room temperature control, with open

  • window detection

  • Distance control option

  • Adaptive start control

Documents / Resources

| FRICO PNF30 Heat Fan Panther [pdf] Instruction Manual
PNF30, PNF30 Heat Fan Panther, Heat Fan Panther, Fan Panther, Panther
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FRICO User Manuals

Related Manuals