PHILIPS DN029B G2 SmartBright LED Downlight Instruction Manual
- June 4, 2024
- Philips
Table of Contents
PHILIPS DN029B G2 SmartBright LED Downlight
Mounting Instruction
Dimensions (mm)
| A| B| C| 90 – 0 0 I
115 – 1-25
150-165
|
---|---|---|---|---|---
9290025312| 9290025313| | 114| 56| 86.5|
9290025318| 9290025319| 9290025320|
9290025314| 9290025315| | 140| 59| 108|
9290025316| | —- 190| 61| 149|
9290025317| | ·1 225|
63 I 190| 19s-210 I|
Installation
- HCB- Height clearance to building element
- SCB- Side clearance to building element
- MIC- Minimum insulation clearance
- SCI – Side clearance to insulation
RISK OF FIRE- Required clearance from structural members and building elements
- SCB= 50mm
- MIC- 0 mm
- HCB- 50mm
- SC= 0 mm
Dimming compatibility
Designed for dimming with many TRIAC/ELV phase cut control dimmers. A list of common dimmers is provided below. Unli sted dimmers do not imply non- compatibility.
- Signify does not accept liability for incompatibility as a result of changes in dimmer specifications. Please refer to your local Signify agent for further details.
< ·;.·
1
|
“= !:) –
Diginet
| ::-.;,r| Tw, _ ,…::.·.| ‘.”- · .
l:L •
| – =-
“”‘-
|
‘¥1 ·,,—
| .- ,
-;, -cn,!……. ii,,;.
| !’ ,,,, ..- -:,g
:’,..,,. – • ·.,:,,.–,,
---|---|---|---|---|---|---|---|---
MEDM| RL| 2-400W| !Ope s/ dimmer
2| Legrand| Cat 400T| R| 10- 400W| 10pcs / dimmer
3| Clipsal| 32ELEDM| R| 10-300W| 8pcs/ dimmer
4| SAL| SDA450| RC| 10- 450W| 12pc s/ dimmer
5| TRADER| DIMPRX| R| 2- 400W| 10ocs/dimmer
6| Clipsal| 41E300PBUDS2M- VW| RLC| 10 – 300W| 8pcs/dimmer
CCT dip switch
Color temperature can be set by CCT dip switch on the back cover:
- Adjust toggle to select the prefered color temperature. The initial setting is 300OK.
- Install the fitting according to instruction above.
Please note: Remove product from power source before attempting to switch between color temperature.
Inrush current
9290025312
9290025313
|
9290025314
9290025315
|
9290025316
|
9290025317
| 9290025318
9290025319
9290025320
|
---|---|---|---|---|---
| lnom(Run current) (mA)| 38| 45| 50| 82| 40
lpeak (A)| 0.96| 1.26| 1.28| 2.2| 0.8
Tref (ms)| 0.051| 0.038| 0.041| 0.039| 0.12
AC Leakage current (mA)| <0 .7| <0 . 7| <0 .7| <0.7| <0 . 7
MCB (Type B 16A, pcs)| 336| 284| 256| 156| 490
MCB (Type C 16A , pcs)| 336| 284| 256| 156| 490
| | | | | | | |
-
Please read this manual carefully before using the product. Do not switch it on before completing installation.
-
The luminaire shall be installed by a qualified electrician and wired in accordance with the latest IEE electrical regulations or national requirements.
-
The external flex and plug of this luminaire cannot be replaced; if the flex and plug are damaged, the luminaire shall be destroyed.
-
Building insulation abutting or covering luminaires
Building insulation that abuts or covers a recessed luminaire, is part of a recessed luminaire, or is within 100 mm horizontally of a luminaire shall:
a) Maintain its dimensions and structural integrity when exposed to the maximum surface temperature of
the class of luminaire, being 90°C in the case of IC-4(IC-F) luminaires;
b) When intended to be in contact with Ic-4(IC-F) luminaires, withstand a 30s needle flame test carried out in accordance with AS/NZS 60695.II.5 with the flame applied to all surfaces of the sample -
The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.
-
The luminaire complied with AS/NZS 60598. I: 2017; 60598.2.2: 2016.
-
The luminaire must not be used or stored in a corrosive environment where hazardous materials such as sulfur, chlorine, phthalates, etc, are present.
-
WARNING- Risk of overheating or fire if the clearance distances are compromised.
-
For indoor use only.
- Distributed by: Reduction Revolution Pty Ltd | www.reductionrevolution.com.au/LED