smart peristaltic pump
Quick Start Guide
A1 2022/03/15
S363 AIP Wifi Smart Peristaltic Pump
Kamoer fluid tech (Shanghai) Co., Ltd.
www.kamoer.com
FCC warning
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful interference to radio or television reception, which can be determined by turning the device off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the device and receiver.
- Connect the device into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment
FCC Radiation Exposure Statement The antennas used for this transmitter must
be installed to provide a separation distance of at least 20 cm from all
persons and must not be co-located for operating in conjunction with any other
antenna or transmitter.
Notice
We have considered the safety of the user in the process of design of the instrument. Please read the manual carefully for installing and use of the instrument. Any improper operation may cause damage or danger.
-
Safety
**** The product belongs to Active Products. The Operator should follow the regulation rules to avoid danger.
If you find any visible damage, please do not switch on.
Be sure not to use in humid environment, avoid damage by short circuit.
Temperature changes or mechanical wear may cause the increases in the dispensed volume. -
Defect and anomalous situation
You must stop any operation immediately if the equipment is damaged. The equipment may be damaged when the following situation occurs:
- There is visual damage.
- The product suddenly does not work.
- The product is located in an inappropriate position.
About AIP WIFI
AIP series peristaltic pump is using stepping motor control, commonly used in
low traffic and high precision setting, configure the touch screen 480 x 272,
powerful, easy to operate.
In addition to touch screen control, AIP WIFI also contains a variety of
external control meth including mobile phone App control via WIFI, analog
control (0~5V, 4~20mA), RS485 control CAN control.
Figure 1-1 Exterior look
Definition of button:
- Clockwise rotation button: press the setting pump to rotate clockwise (to be used when the pump stops)
- Counterclockwise rotation: press the button to set the pump to rotate counterclockwise (to be used when the pump stops)
- Quick emptying button: it is used in the pump line calibration interface. After pressing down, the pump runs quickly to empty, and then press down again to stop emptying
- Acceleration button: the pump speed increases after pressing down, and the modified speed can be used continuously (in continuous mode).
- Deceleration button: the pump speed decreases after pressing down, and the modified speed can be used continuously (in continuous mode).
- Start/stop button: in the continuous mode, distribution mode and pump line calibration interface, the button pump starts the task operation, and press the pump again to stop the task operation
Definition of interface:
- Fan: A machine fan used to remove heat from the machine during operation;
- Liquid level sensor interface: used to connect the liquid level sensor expansion component, so that the instrument has the function of liquid level detection;
- Temperature sensor interface: used to plug the temperature sensor expansion component, so that the instrument has the function of temperature detection;
- CAN communication interface: connect RJ45 connector CAN communication line, can remotely control the machine through CAN;
- RS485 communication interface: connect RJ45 connector RS485 communication line, remotely control the machine through RS485;
- Wi-Fi antenna: 2.4G Wi-Fi antennas, which can be controlled by mobile app;
- Integrated switch: switch and power line interface;
- 9. Expansion interface: used to connect with expansion devices, such as foot switch, PC,
PLC and other equipment, two ports can be inserted at will. However, to ensure
availability, please use kamoer’s standard harness. Specific wiring harness
definition reference analog control pin definition.
! ! Note that the use of non-kamoer standard harnesses may result in damage to
the instrument and the damage is not covered by the warranty.
Analog control
Pin definition
This machine contains 0~5V analog control, 4~20mA analog control;
Specific analog control pins are defined as follows:
Pin | Connection name | Parameters are defined |
---|---|---|
1 | Analog quantity control direction (DIR) | High level electricity clockwise, |
low level counterclockwise
2| Analog control common terminal (GND)|
3| Analog quantity control start and stop (Q/T)| Low level starts, high level
stops
4| Foot switch (+)|
5| Foot switch (-)|
6| 0-5V Control (5V-)|
7| 0-5V Control (5V+)| 0-5V corresponds to a rotation speed of 0.1-600rpm
8| 4-20mA Control (mA-)|
9| 4-20mA Control (mA+)| 4-20mA corresponds to a rotation speed of 0.1-600rpm
Download App
-
Scan the QR code and download the app corresponding to the icon below.
| |
---|---|---https://itunes.apple.com/cn/app/kamoerpumps/id1438698523?mt=8
| |
<https://play.google.com/store/apps/details?id=com.kamoer.f4_plus>
View the tutorial
Click the icon on the top left corner of the device list page to enter the device selecinterface, select AIP from the device selection interface, and enter the view interface of AIP umanual and FAQ.
Distribution network status
AIP can be operated and used through mobile phone App. There are two control methods for App to connect to Wi-Fi.
Connection
mode| Description| Advantages| Disadvantages
---|---|---|---
Direct mode (AP)| Factory default mode, you can see the dosing pump Wi-Fi in
the Wi-Fi list of the mobile phone (the name starts with KAMOER, followed by
the 5-digit serial number, the connection password is a12345678), and the user
directly connects to the Wi-Fi control| Simple and stable connection| Only one
pump can be
controlled at a time
Router mode (STA)| Cannot see the dosing pump Wi-Fi in the mobile Wi-Fi list,
the user controls the dosing pump by connecting the wireless router| After the
configuration is
successful, multiple pumps
can be controlled by the router| only support 2.4G router,
5G router is not supported
The screen title bar shows the Wi-Fi connection method and connection status:
Indicates the AP direct connection mode;
Indicates the STA router mode;
Indicates the STA router mode, but the machine is not connected to the router;
Indicates that the machine is waiting for the ration network status in Wi-Fi.
At this time,
the user can configure the machine to connect to the router on the mobile terminal and enter the STA router mode.
485 remote control
AIP includes 485 remote control function. For details, please refer to the AIP
485 remote control protocol.
CAN remote control
The AIP includes the CAN remote control function. For the specific operation
method, please refer to the AIP CAN operation remote protocol.
Technical parameters
Drive | Stepper motor |
---|---|
Power | Input:AC100-240V |
Output:DC36V 4.3A
Weight| 7.6Kg (Include Pump)
Size| L304 x W164 x H244 mm
Temperature| 0℃ to 50℃
Packing list
Ite | Part | Description | Quantity |
---|---|---|---|
1 | AIP peristaltic pump | 1 | |
2 | Power wire | AC250V 10A | 1 |
3 | User manual | English | 1 |
Warranty service
Warranty service is only valid for users who are correctly installed, used and
maintained according to the manual. Any malfunction or damage is not covered
by the warranty. Please keep your purchase voucher properly so that you can
get satisfactory after-sales service in time.
The company will provide free warranty service for any damage caused by
manufacturing processes or components within one year from the date of
purchase. The free repair service provided during the warranty period includes
free repair, free replacement and replacement of faulty spare parts, and
products that cannot be repaired are replaced by the same model. The free
service does not include shipping costs for the product due to repairs
Kamoer Fluid Tech (Shanghai) Co., Ltd.
Addr: Building 4, No.79 Xiangjing Road, Songjiang District, Shanghai
Website:www.kamoer.com
Kamoer is registered trademark of Kamoer Fluid Tech (Shanghai) Co., Ltd. We
reserve the right to improve or alter appearance and technical specifications
without notice.
References
- Peristaltic Pumps, Diaphragm Pumps, Syringe Pumps - Katruer Fluid Technology
- Peristaltic Pumps, Diaphragm Pumps, Syringe Pumps - Katruer Fluid Technology
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>